메뉴 건너뛰기




Volumn 4, Issue 7, 2011, Pages 1033-1045

Tradeoffs amongst fatigue, wear, and oxidation resistance of cross-linked ultra-high molecular weight polyethylene

Author keywords

Fatigue; Microstructure; Oxidation; Polyethylene (UHMWPE); Wear

Indexed keywords

ANNEALED MATERIALS; FATIGUE CRACK PROPAGATION RESISTANCE; FATIGUE PERFORMANCE; OXIDATIVE STABILITY; RADIATION DOSE; TOTAL JOINT REPLACEMENT; ULTRA-HIGH; WEAR PERFORMANCE;

EID: 79960557217     PISSN: 17516161     EISSN: 18780180     Source Type: Journal    
DOI: 10.1016/j.jmbbm.2011.03.012     Document Type: Article
Times cited : (117)

References (49)
  • 1
    • 0141447819 scopus 로고    scopus 로고
    • The effects of degree of crosslinking on the fatigue crack initiation and propagation resistance of orthopedic-grade polyethylene
    • Baker D.A., Bellare A., Pruitt L. The effects of degree of crosslinking on the fatigue crack initiation and propagation resistance of orthopedic-grade polyethylene. J. Biomed. Mater. Res. A 2003, 66(1):146-154.
    • (2003) J. Biomed. Mater. Res. A , vol.66 , Issue.1 , pp. 146-154
    • Baker, D.A.1    Bellare, A.2    Pruitt, L.3
  • 2
    • 0033990310 scopus 로고    scopus 로고
    • Compression and tension fatigue resistance of medical grade ultra high molecular weight polyethylene: the effect of morphology, sterilization, aging and temperature
    • Baker D.A., Hastings R.S., Pruitt L. Compression and tension fatigue resistance of medical grade ultra high molecular weight polyethylene: the effect of morphology, sterilization, aging and temperature. Polymer 2000, 41(2):795-808.
    • (2000) Polymer , vol.41 , Issue.2 , pp. 795-808
    • Baker, D.A.1    Hastings, R.S.2    Pruitt, L.3
  • 3
    • 0023007566 scopus 로고
    • The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement
    • Bartel D.L., Bicknell V.L., Wright T.M. The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement. J. Bone Joint Surg. Am. 1986, 68(7):1041-1051.
    • (1986) J. Bone Joint Surg. Am. , vol.68 , Issue.7 , pp. 1041-1051
    • Bartel, D.L.1    Bicknell, V.L.2    Wright, T.M.3
  • 5
    • 67650783914 scopus 로고    scopus 로고
    • Tensile and tribological properties of high-crystallinity radiation crosslinked UHMWPE
    • Bistolfi A., Turell M.B., Lee Y.L., Bellare A. Tensile and tribological properties of high-crystallinity radiation crosslinked UHMWPE. J. Biomed. Mater. Res. B Appl. Biomater. 2009, 90(1):137-144.
    • (2009) J. Biomed. Mater. Res. B Appl. Biomater. , vol.90 , Issue.1 , pp. 137-144
    • Bistolfi, A.1    Turell, M.B.2    Lee, Y.L.3    Bellare, A.4
  • 12
    • 52449106712 scopus 로고    scopus 로고
    • How have new sterilization techniques and new forms of polyethylene influenced wear in total joint replacement?
    • Crowninshield R.D., Muratoglu O.K. How have new sterilization techniques and new forms of polyethylene influenced wear in total joint replacement?. J. Am. Acad. Orthop. Surg. 2008, 16(Suppl. 1):S80-S85.
    • (2008) J. Am. Acad. Orthop. Surg. , vol.16 , Issue.SUPPL. 1
    • Crowninshield, R.D.1    Muratoglu, O.K.2
  • 16
    • 0034110406 scopus 로고    scopus 로고
    • Degradation of mechanical behavior in UHMWPE after natural and accelerated aging
    • Edidin A.A., Jewett C.W., Kalinowski A., Kwarteng K., Kurtz S.M. Degradation of mechanical behavior in UHMWPE after natural and accelerated aging. Biomaterials 2000, 21(14):1451-1460.
    • (2000) Biomaterials , vol.21 , Issue.14 , pp. 1451-1460
    • Edidin, A.A.1    Jewett, C.W.2    Kalinowski, A.3    Kwarteng, K.4    Kurtz, S.M.5
  • 17
    • 0032773847 scopus 로고    scopus 로고
    • Plasticity-induced damage layer is a precursor to wear in radiation-cross-linked UHMWPE acetabular components for total hip replacement. Ultra-high-molecular-weight polyethylene
    • Edidin A.A., Pruitt L., Jewett C.W., Crane D.J., Roberts D., Kurtz S.M. Plasticity-induced damage layer is a precursor to wear in radiation-cross-linked UHMWPE acetabular components for total hip replacement. Ultra-high-molecular-weight polyethylene. J. Arthroplasty 1999, 14(5):616-627.
    • (1999) J. Arthroplasty , vol.14 , Issue.5 , pp. 616-627
    • Edidin, A.A.1    Pruitt, L.2    Jewett, C.W.3    Crane, D.J.4    Roberts, D.5    Kurtz, S.M.6
  • 18
    • 0028446277 scopus 로고
    • The effect of sliding velocity on the friction and wear of UHMWPE for use in total artificial joints
    • Fisher J., Dowson D., Hamdzah H., Lee H.L. The effect of sliding velocity on the friction and wear of UHMWPE for use in total artificial joints. Wear 1994, 175(1-2):219-225.
    • (1994) Wear , vol.175 , Issue.1-2 , pp. 219-225
    • Fisher, J.1    Dowson, D.2    Hamdzah, H.3    Lee, H.L.4
  • 19
    • 6344294149 scopus 로고    scopus 로고
    • Structure and order in lamellar phases determined by small-angle scattering
    • Fruhwirth T., Fritz G., Freiberger N., Glatter O. Structure and order in lamellar phases determined by small-angle scattering. J. Appl. Crystallogr. 2004, 37:703-710.
    • (2004) J. Appl. Crystallogr. , vol.37 , pp. 703-710
    • Fruhwirth, T.1    Fritz, G.2    Freiberger, N.3    Glatter, O.4
  • 21
    • 79960558297 scopus 로고    scopus 로고
    • Effect of vitamin E on fatigue of irradiated UHMWPE. In: 53rd Annual Meeting of the Orthopaedic Research Society. San Diego, CA.
    • Furmanski, J., Atwood, S.A., Feest, E., Tang, J., Hoang, M., Pruitt, L., 2007. Effect of vitamin E on fatigue of irradiated UHMWPE. In: 53rd Annual Meeting of the Orthopaedic Research Society. San Diego, CA.
    • (2007)
    • Furmanski, J.1    Atwood, S.A.2    Feest, E.3    Tang, J.4    Hoang, M.5    Pruitt, L.6
  • 22
    • 34249077387 scopus 로고    scopus 로고
    • Peak stress intensity dictates fatigue crack propagation in UHMWPE
    • Furmanski J., Pruitt L.A. Peak stress intensity dictates fatigue crack propagation in UHMWPE. Polymer 2007, 48(12):3512-3519.
    • (2007) Polymer , vol.48 , Issue.12 , pp. 3512-3519
    • Furmanski, J.1    Pruitt, L.A.2
  • 23
    • 28444433471 scopus 로고    scopus 로고
    • Fatigue crack propagation resistance of virgin and highly crosslinked, thermally treated ultra-high molecular weight polyethylene
    • Gencur S.J., Rimnac C.M., Kurtz S.M. Fatigue crack propagation resistance of virgin and highly crosslinked, thermally treated ultra-high molecular weight polyethylene. Biomaterials 2006, 27(8):1550-1557.
    • (2006) Biomaterials , vol.27 , Issue.8 , pp. 1550-1557
    • Gencur, S.J.1    Rimnac, C.M.2    Kurtz, S.M.3
  • 25
    • 0035180971 scopus 로고    scopus 로고
    • Wear and periprosthetic osteolysis: the problem
    • Harris W.H. Wear and periprosthetic osteolysis: the problem. Clin. Orthop. Relat. Res. 2001, (393):66-70.
    • (2001) Clin. Orthop. Relat. Res. , Issue.393 , pp. 66-70
    • Harris, W.H.1
  • 26
    • 0026202775 scopus 로고
    • Combined chemical and mechanical effects on free radicals in UHMWPE joints during implantation
    • Jahan M.S., Wang C., Schwartz G., Davidson J.A. Combined chemical and mechanical effects on free radicals in UHMWPE joints during implantation. J. Biomed. Mater. Res. 1991, 25(8):1005-1017.
    • (1991) J. Biomed. Mater. Res. , vol.25 , Issue.8 , pp. 1005-1017
    • Jahan, M.S.1    Wang, C.2    Schwartz, G.3    Davidson, J.A.4
  • 27
    • 0032798148 scopus 로고    scopus 로고
    • Tribological properties and microstructure evolution of ultra-high molecular weight polyethylene
    • Klapperich C., Komvopoulos K., Pruitt L. Tribological properties and microstructure evolution of ultra-high molecular weight polyethylene. J. Tribol. 1999, 121(2):394-402.
    • (1999) J. Tribol. , vol.121 , Issue.2 , pp. 394-402
    • Klapperich, C.1    Komvopoulos, K.2    Pruitt, L.3
  • 30
    • 79960560170 scopus 로고    scopus 로고
    • Java applets for power and sample size.
    • Lenth, R.V., 2006-2009. Java applets for power and sample size.
    • (2006)
    • Lenth, R.V.1
  • 31
    • 0032927112 scopus 로고    scopus 로고
    • Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements
    • McKellop H., Shen F.W., Lu B., Campbell P., Salovey R. Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements. J. Orthop. Res. 1999, 17(2):157-167.
    • (1999) J. Orthop. Res. , vol.17 , Issue.2 , pp. 157-167
    • McKellop, H.1    Shen, F.W.2    Lu, B.3    Campbell, P.4    Salovey, R.5
  • 33
    • 67650822628 scopus 로고    scopus 로고
    • Evaluation of sequentially crosslinked ultra-high molecular weight polyethylene
    • Morrison M.L., Jani S. Evaluation of sequentially crosslinked ultra-high molecular weight polyethylene. J. Biomed. Mater. Res. B Appl. Biomater. 2009, 90(1):87-100.
    • (2009) J. Biomed. Mater. Res. B Appl. Biomater. , vol.90 , Issue.1 , pp. 87-100
    • Morrison, M.L.1    Jani, S.2
  • 34
    • 0035117295 scopus 로고    scopus 로고
    • A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul award
    • Muratoglu O.K., Bragdon C.R., O'Connor D.O., Jasty M., Harris W.H. A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul award. J. Arthroplasty 2001, 16(2):149-160.
    • (2001) J. Arthroplasty , vol.16 , Issue.2 , pp. 149-160
    • Muratoglu, O.K.1    Bragdon, C.R.2    O'Connor, D.O.3    Jasty, M.4    Harris, W.H.5
  • 35
    • 0033178826 scopus 로고    scopus 로고
    • Unified wear model for highly crosslinked ultra-high molecular weight polyethylenes (UHMWPE)
    • Muratoglu O.K., Bragdon C.R., O'Connor D.O., Jasty M., Harris W.H., Gul R., McGarry F. Unified wear model for highly crosslinked ultra-high molecular weight polyethylenes (UHMWPE). Biomaterials 1999, 20(16):1463-1470.
    • (1999) Biomaterials , vol.20 , Issue.16 , pp. 1463-1470
    • Muratoglu, O.K.1    Bragdon, C.R.2    O'Connor, D.O.3    Jasty, M.4    Harris, W.H.5    Gul, R.6    McGarry, F.7
  • 36
    • 0017504738 scopus 로고
    • Molecular-conformations in polyethylene after recrystallization or annealing at high-pressures
    • Olley R., Bassett D. Molecular-conformations in polyethylene after recrystallization or annealing at high-pressures. J. Polym. Sci. Ser. B 1977, 15(6):1011-1027.
    • (1977) J. Polym. Sci. Ser. B , vol.15 , Issue.6 , pp. 1011-1027
    • Olley, R.1    Bassett, D.2
  • 37
    • 79960558919 scopus 로고    scopus 로고
    • Multi-axial tribo-system: rolling, sliding and rotation of UHMWPE in total joint replacements. University of California at Berkeley. Berkeley, CA.
    • Patten, E.W., 2008. Multi-axial tribo-system: rolling, sliding and rotation of UHMWPE in total joint replacements. University of California at Berkeley. Berkeley, CA.
    • (2008)
    • Patten, E.W.1
  • 38
    • 0031954475 scopus 로고    scopus 로고
    • Factors affecting near-threshold fatigue crack propagation behavior of orthopedic grade ultra high molecular weight polyethylene
    • Pruitt L., Bailey L. Factors affecting near-threshold fatigue crack propagation behavior of orthopedic grade ultra high molecular weight polyethylene. Polymer 1998, 39(8-9):1545-1553.
    • (1998) Polymer , vol.39 , Issue.8-9 , pp. 1545-1553
    • Pruitt, L.1    Bailey, L.2
  • 39
    • 27644448756 scopus 로고    scopus 로고
    • Effect of cross-linking on the microstructure and mechanical properties of ultra-high molecular weight polyethylene
    • Ries M.D., Pruitt L. Effect of cross-linking on the microstructure and mechanical properties of ultra-high molecular weight polyethylene. Clin. Orthop. Relat. Res. 2005, 440:149-156.
    • (2005) Clin. Orthop. Relat. Res. , vol.440 , pp. 149-156
    • Ries, M.D.1    Pruitt, L.2
  • 40
    • 0004505631 scopus 로고
    • Elastic compliances and stress-intensity factors for side-grooved compact specimens
    • Shih C.F., Lorenzi H.G., Andrews W.R. Elastic compliances and stress-intensity factors for side-grooved compact specimens. Int. J. Fract. 1977, 13(4):544-548.
    • (1977) Int. J. Fract. , vol.13 , Issue.4 , pp. 544-548
    • Shih, C.F.1    Lorenzi, H.G.2    Andrews, W.R.3
  • 41
    • 28744453385 scopus 로고    scopus 로고
    • The combined effects of crosslinking and high crystallinity on the microstructural and mechanical properties of ultra high molecular weight polyethylene
    • Simis K.S., Bistolfi A., Bellare A., Pruitt L.A. The combined effects of crosslinking and high crystallinity on the microstructural and mechanical properties of ultra high molecular weight polyethylene. Biomaterials 2006, 27(9):1688-1694.
    • (2006) Biomaterials , vol.27 , Issue.9 , pp. 1688-1694
    • Simis, K.S.1    Bistolfi, A.2    Bellare, A.3    Pruitt, L.A.4
  • 43
    • 1542268875 scopus 로고    scopus 로고
    • A study of the nanostructure and tensile properties of ultra-high molecular weight polyethylene
    • Turell M.B., Bellare A. A study of the nanostructure and tensile properties of ultra-high molecular weight polyethylene. Biomaterials 2004, 25(17):3389-3398.
    • (2004) Biomaterials , vol.25 , Issue.17 , pp. 3389-3398
    • Turell, M.B.1    Bellare, A.2
  • 44
    • 34548034477 scopus 로고    scopus 로고
    • Rolling sliding wear of UHMWPE for knee bearing applications
    • Van Citters D.W., Kennedy F.E., Collier J.P. Rolling sliding wear of UHMWPE for knee bearing applications. Wear 2007, 263(7-12):1087-1094.
    • (2007) Wear , vol.263 , Issue.7-12 , pp. 1087-1094
    • Van Citters, D.W.1    Kennedy, F.E.2    Collier, J.P.3
  • 45
    • 34548443418 scopus 로고    scopus 로고
    • Structural and chemical changes in ultra-high-molecular-weight polyethylene due to gamma radiation-induced crosslinking and annealing in air
    • Viano A.M., Spence K.E., Shanks M.A., Scott M.A., Redfearn R.D., Carlson C.W., Holm T.A., Ray A.K. Structural and chemical changes in ultra-high-molecular-weight polyethylene due to gamma radiation-induced crosslinking and annealing in air. Biomed. Mater. Eng. 2007, 17(5):257-268.
    • (2007) Biomed. Mater. Eng. , vol.17 , Issue.5 , pp. 257-268
    • Viano, A.M.1    Spence, K.E.2    Shanks, M.A.3    Scott, M.A.4    Redfearn, R.D.5    Carlson, C.W.6    Holm, T.A.7    Ray, A.K.8
  • 46
    • 0035280295 scopus 로고    scopus 로고
    • A unified theory of wear for ultra-high molecular weight polyethylene in multi-directional sliding
    • Wang A. A unified theory of wear for ultra-high molecular weight polyethylene in multi-directional sliding. Wear 2001, 248(1-2):38-47.
    • (2001) Wear , vol.248 , Issue.1-2 , pp. 38-47
    • Wang, A.1
  • 47
    • 0029255360 scopus 로고
    • Wear mechanisms of UHMWPE in total joint replacements
    • Wang A., Sun D.C., Stark C., Dumbleton J.H. Wear mechanisms of UHMWPE in total joint replacements. Wear 1995, 181-183(1):241-249.
    • (1995) Wear , Issue.1 , pp. 241-249
    • Wang, A.1    Sun, D.C.2    Stark, C.3    Dumbleton, J.H.4
  • 49
    • 18644372774 scopus 로고    scopus 로고
    • Wear mechanisms of untreated and gamma irradiated ultra-high molecular weight polyethylene for total joint replacements
    • Zhou J., Komvopoulos K. Wear mechanisms of untreated and gamma irradiated ultra-high molecular weight polyethylene for total joint replacements. J. Tribol. 2005, 127(2):273-279.
    • (2005) J. Tribol. , vol.127 , Issue.2 , pp. 273-279
    • Zhou, J.1    Komvopoulos, K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.