메뉴 건너뛰기




Volumn 196, Issue 6, 2011, Pages 1324-1331

Hepatocellular carcinoma in patients weighing 70 kg or less: Initial trial of compact-bolus dynamic CT with low-dose contrast material at 80 kVp

Author keywords

Contrast material; Hepatic dynamic CT; Hepatocellular carcinoma; Low tube voltage; MDCT

Indexed keywords

IOPAMIDOL;

EID: 79960489253     PISSN: 0361803X     EISSN: 15463141     Source Type: Journal    
DOI: 10.2214/AJR.10.4545     Document Type: Article
Times cited : (40)

References (34)
  • 1
    • 0842348097 scopus 로고    scopus 로고
    • Risk of cancer from diagnostic X-rays: Estimates for the UK and 14 other countries
    • DOI 10.1016/S0140-6736(04)15433-0
    • Berrington de González A, Darby S. Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countries. Lancet 2004; 363:345-351 (Pubitemid 38169539)
    • (2004) Lancet , vol.363 , Issue.9406 , pp. 345-351
    • De Gonzalez, A.B.1    Darby, S.2
  • 2
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography - An increasing source of radiation exposure
    • DOI 10.1056/NEJMra072149
    • Brenner DJ, Hall EJ. Computed tomography: an increasing source of radiation exposure. N Engl J Med 2007; 357:2277-2284 (Pubitemid 350190758)
    • (2007) New England Journal of Medicine , vol.357 , Issue.22 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 3
    • 0028070216 scopus 로고
    • Understanding and optimizing use of contrast material for CT of the liver
    • Baron RL. Understanding and optimizing use of contrast material for CT of the liver. AJR 1994; 163:323-331 (Pubitemid 24242512)
    • (1994) American Journal of Roentgenology , vol.163 , Issue.2 , pp. 323-331
    • Baron, R.L.1
  • 4
    • 0029740035 scopus 로고    scopus 로고
    • Multiple-phase helical CT of the liver for detecting small hepatomas in patients with liver cirrhosis: Contrast-injection protocol and optimal timing
    • Mitsuzaki K, Yamashita Y, Ogata I, Nishiharu T, Urata J, Takahashi M. Multiple-phase helical CT of the liver for detecting small hepatomas in patients with liver cirrhosis: contrast-injection 80 kVp protocol and optimal timing. AJR 1996; 167:753-757 (Pubitemid 26279730)
    • (1996) American Journal of Roentgenology , vol.167 , Issue.3 , pp. 753-757
    • Mitsuzaki, K.1    Yamashita, Y.2    Ogata, I.3    Nishiharu, T.4    Urata, J.5    Takahashi, M.6
  • 7
    • 0036942651 scopus 로고    scopus 로고
    • Dose reduction opportunities for CT scanners
    • DOI 10.1007/s00247-002-0678-7
    • Toth TL. Dose reduction opportunities for CT scanners. Pediatr Radiol 2002; 32:261-267 (Pubitemid 36075696)
    • (2002) Pediatric Radiology , vol.32 , Issue.4 , pp. 261-267
    • Toth, T.L.1
  • 8
    • 33645082011 scopus 로고    scopus 로고
    • Improvement of low-contrast detectability in low-dose hepatic multidetector computed tomography using a novel adaptive filter: Evaluation with a computer-simulated liver including tumors
    • DOI 10.1097/01.rli.0000188026.20172.5d, PII 0000442420060100000001
    • Funama Y, Awai K, Miyazaki O, et al. Improvement of low-contrast detectability in low-dose hepatic multidetector computed tomography using a novel adaptive filter: evaluation with a computer-simulated liver including tumors. Invest Radiol 2006; 41:1-7 (Pubitemid 44378272)
    • (2006) Investigative Radiology , vol.41 , Issue.1 , pp. 1-7
    • Funama, Y.1    Awai, K.2    Miyazaki, O.3    Nakayama, Y.4    Goto, T.5    Omi, Y.6    Shimonobo, T.7    Liu, D.8    Yamashita, Y.9    Hori, S.10
  • 9
    • 27744559376 scopus 로고    scopus 로고
    • Radiation dose reduction without degradation of low-contrast detectability at abdominal multisection CT with a low-tube voltage technique: Phantom study
    • DOI 10.1148/radiol.2373041643
    • Funama Y, Awai K, Nakayama Y, et al. Radiation dose reduction without degradation of low-contrast detectability at abdominal multisection CT with a low-tube voltage technique: phantom study. Radiology 2005; 237:905-910 (Pubitemid 41636380)
    • (2005) Radiology , vol.237 , Issue.3 , pp. 905-910
    • Funama, Y.1    Awai, K.2    Nakayama, Y.3    Kakei, K.4    Nagasue, N.5    Shimamura, M.6    Sato, N.7    Sultana, S.8    Morishita, S.9    Yamashita, Y.10
  • 10
    • 4143148392 scopus 로고    scopus 로고
    • Detection and characterization of lesions on low-radiation-dose abdominal CT images postprocessed with noise reduction filters
    • DOI 10.1148/radiol.2323031563
    • Kalrai MK, Maher MM, Blake MA, et al. Detection and characterization of lesions on low-radiation-dose abdominal CT images postprocessed with noise reduction filters. Radiology 2004; 232: 791-797 (Pubitemid 39100265)
    • (2004) Radiology , vol.232 , Issue.3 , pp. 791-797
    • Kalra, M.K.1    Maher, M.M.2    Blake, M.A.3    Lucey, B.C.4    Karau, K.5    Toth, T.L.6    Avinash, G.7    Halpern, E.F.8    Saini, S.9
  • 11
    • 4644221703 scopus 로고    scopus 로고
    • Sixteen-detector row CT of abdomen and pelvis: Study for optimization of z-axis modulation technique performed in 153 patients
    • DOI 10.1148/radiol.2331031505
    • Kalra MK, Maher MM, Kamath RS, et al. Sixteen-detector row CT of abdomen and pelvis: study for optimization of Z-axis modulation technique performed in 153 patients. Radiology 2004; 233:241-249 (Pubitemid 39280980)
    • (2004) Radiology , vol.233 , Issue.1 , pp. 241-249
    • Kalra, M.K.1    Maher, M.M.2    Kamath, R.S.3    Horiuchi, T.4    Toth, T.L.5    Halpern, E.F.6    Saini, S.7
  • 13
    • 13244297711 scopus 로고    scopus 로고
    • Techniques and applications of automatic tube current modulation for CT
    • Kalra MK, Maher MM, Toth TL, et al. Techniques and applications of automatic tube current modulation for CT. Radiology 2004; 233:649-657
    • (2004) Radiology , vol.233 , pp. 649-657
    • Kalra, M.K.1    Maher, M.M.2    Toth, T.L.3
  • 16
    • 69949109658 scopus 로고    scopus 로고
    • Low-dose MDCT urography: Feasibility study of low-tube-voltage technique and adaptive noise reduction filter
    • [web]W220-W229
    • Yanaga Y, Awai K, Funama Y, et al. Low-dose MDCT urography: feasibility study of low-tube-voltage technique and adaptive noise reduction filter. AJR 2009; 193:868; [web]W220-W229
    • (2009) AJR , vol.193 , pp. 868
    • Yanaga, Y.1    Awai, K.2    Funama, Y.3
  • 17
    • 0346218104 scopus 로고    scopus 로고
    • Effect of Contrast Material Injection Duration and Rate on Aortic Peak Time and Peak Enhancement at Dynamic CT Involving Injection Protocol with Dose Tailored to Patient Weight
    • DOI 10.1148/radiol.2301021008
    • Awai K, Hiraishi K, Hori S. Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight. Radiology 2004; 230:142-150 (Pubitemid 37549795)
    • (2004) Radiology , vol.230 , Issue.1 , pp. 142-150
    • Awai, K.1    Hiraishi, K.2    Hori, S.3
  • 22
    • 21244473081 scopus 로고    scopus 로고
    • A framework for optimising the radiographic technique in digital X-ray imaging
    • DOI 10.1093/rpd/nch562
    • Samei E, Dobbins JT 3rd, Lo JY, Tornai MP. A framework for optimising the radiographic technique in digital X-ray imaging. Radiat Prot Dosimetry 2005; 114:220-229 (Pubitemid 40883685)
    • (2005) Radiation Protection Dosimetry , vol.114 , Issue.1-3 , pp. 220-229
    • Samei, E.1    Dobbins III, J.T.2    Lo, J.Y.3    Tornai, M.P.4
  • 23
    • 0024459172 scopus 로고
    • Reproducibility of histomorphologic diagnoses with special reference to the kappa statistic
    • Svanholm H, Starklint H, Gundersen HJ, Fabricius J, Barlebo H, Olsen S. Reproducibility of histomorphologic diagnoses with special reference to the kappa statistic. APMIS 1989; 97:689-698 (Pubitemid 19217684)
    • (1989) APMIS , vol.97 , Issue.8 , pp. 689-698
    • Svanholm, H.1    Starklint, H.2    Gundersen, H.J.G.3    Fabricius, J.4    Barlebo, H.5    Olsen, S.6
  • 25
    • 66149188637 scopus 로고    scopus 로고
    • Contrast-induced nephropathy and long-term adverse events: Cause and effect?
    • Solomon RJ, Mehran R, Natarajan MK, et al. Contrast-induced nephropathy and long-term adverse events: cause and effect? Clin J Am Soc Nephrol 2009; 4:1162-1169
    • (2009) Clin J Am Soc Nephrol , vol.4 , pp. 1162-1169
    • Solomon, R.J.1    Mehran, R.2    Natarajan, M.K.3
  • 27
    • 0036831529 scopus 로고    scopus 로고
    • AAPM/RSNA physics tutorial for residents: Topics in CT - Radiation dose in CT
    • McNitt-Gray MF. AAPM/RSNA physics tutorial for residents: topics in CT - radiation dose in CT. RadioGraphics 2002; 22:1541-1553
    • (2002) RadioGraphics , vol.22 , pp. 1541-1553
    • McNitt-Gray, M.F.1
  • 31
    • 69949096664 scopus 로고    scopus 로고
    • Iterative reconstruction technique for reducing body radiation dose at CT: Feasibility study
    • Hara AK, Paden RG, Silva AC, Kujak JL, Lawder HJ, Pavlicek W. Iterative reconstruction technique for reducing body radiation dose at CT: feasibility study. AJR 2009; 193:764-771
    • (2009) AJR , vol.193 , pp. 764-771
    • Hara, A.K.1    Paden, R.G.2    Silva, A.C.3    Kujak, J.L.4    Lawder, H.J.5    Pavlicek, W.6
  • 34
    • 0031932016 scopus 로고    scopus 로고
    • Frequency and effects of extravasation of ionic and nonionic CT contrast media during rapid bolus injection
    • Federle MP, Chang PJ, Confer S, Ozgun B. Frequency and effects of extravasation of ionic and nonionic CT contrast media during rapid bolus injection. Radiology 1998; 206:637-640 (Pubitemid 28128508)
    • (1998) Radiology , vol.206 , Issue.3 , pp. 637-640
    • Federle, M.P.1    Chang, P.J.2    Confer, S.3    Ozgun, B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.