메뉴 건너뛰기




Volumn 41, Issue 1, 2006, Pages 1-7

Improvement of low-contrast detectability in low-dose hepatic multidetector computed tomography using a novel adaptive filter: Evaluation with a computer-simulated liver including tumors

Author keywords

Adaptive noise reduction filter; Hepatic MDCT; Low contrast detectability; Low dose

Indexed keywords

ARTICLE; COMPUTER SIMULATION; CONTRAST ENHANCEMENT; CONTRAST RADIOGRAPHY; EVALUATION; HUMAN; IMAGE ANALYSIS; IMAGE QUALITY; IMAGE RECONSTRUCTION; LIVER TUMOR; MULTIDETECTOR COMPUTED TOMOGRAPHY; NOISE REDUCTION; PHANTOM; PRIORITY JOURNAL; RADIATION DOSE; RECEIVER OPERATING CHARACTERISTIC; AGED; ANALYSIS OF VARIANCE; COMPUTER ASSISTED DIAGNOSIS; COMPUTER ASSISTED TOMOGRAPHY; FEMALE; LIVER CELL CARCINOMA; MALE; METHODOLOGY; MIDDLE AGED; NONPARAMETRIC TEST; RADIOGRAPHY; ROC CURVE;

EID: 33645082011     PISSN: 00209996     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.rli.0000188026.20172.5d     Document Type: Article
Times cited : (47)

References (26)
  • 1
    • 18844403150 scopus 로고    scopus 로고
    • Multi-detector row CT systems and image-reconstruction techniques
    • Flohr TG, Schaller S, Stierstorfer K, et al. Multi-detector row CT systems and image-reconstruction techniques. Radiology. 2005;235:756-773.
    • (2005) Radiology , vol.235 , pp. 756-773
    • Flohr, T.G.1    Schaller, S.2    Stierstorfer, K.3
  • 2
    • 7044271152 scopus 로고    scopus 로고
    • Multi-detector row CT: Principles and practice for abdominal applications
    • Saini S. Multi-detector row CT: principles and practice for abdominal applications. Radiology. 2004;233:323-327.
    • (2004) Radiology , vol.233 , pp. 323-327
    • Saini, S.1
  • 3
    • 22844451841 scopus 로고    scopus 로고
    • Effect of acquisition technique on radiation dose and image quality in multidetector row computed tomography coronary angiography with submillimeter collimation
    • Gerber TC, Stratmann BP, Kuzo RS, et al. Effect of acquisition technique on radiation dose and image quality in multidetector row computed tomography coronary angiography with submillimeter collimation. Invest Radiol. 2005;40:556-563.
    • (2005) Invest Radiol , vol.40 , pp. 556-563
    • Gerber, T.C.1    Stratmann, B.P.2    Kuzo, R.S.3
  • 4
    • 0029970126 scopus 로고    scopus 로고
    • Small hepatocellular carcinoma in patients with chronic liver damage: Prospective comparison of detection with dynamic MR imaging and helical CT of the whole liver
    • Yamashita Y, Mitsuzaki K, Yi T, et al. Small hepatocellular carcinoma in patients with chronic liver damage: prospective comparison of detection with dynamic MR imaging and helical CT of the whole liver. Radiology. 1996;200:79-84.
    • (1996) Radiology , vol.200 , pp. 79-84
    • Yamashita, Y.1    Mitsuzaki, K.2    Yi, T.3
  • 5
    • 0036131183 scopus 로고    scopus 로고
    • Small hypervascular hepatocellular carcinoma revealed by double arterial phase CT performed with single breath-hold scanning and automatic bolus tracking
    • Kim T, Murakami T, Hori M, et al. Small hypervascular hepatocellular carcinoma revealed by double arterial phase CT performed with single breath-hold scanning and automatic bolus tracking. AJR Am J Roentgenol. 2002;178:899-904.
    • (2002) AJR Am J Roentgenol , vol.178 , pp. 899-904
    • Kim, T.1    Murakami, T.2    Hori, M.3
  • 6
  • 7
    • 0035117540 scopus 로고    scopus 로고
    • Hypervascular hepatocellular carcinoma: Detection with double arterial phase multi-detector row helical CT
    • Murakami T, Kim T, Takamura M, et al. Hypervascular hepatocellular carcinoma: detection with double arterial phase multi-detector row helical CT. Radiology. 2001;218:763-767.
    • (2001) Radiology , vol.218 , pp. 763-767
    • Murakami, T.1    Kim, T.2    Takamura, M.3
  • 8
    • 0142209430 scopus 로고    scopus 로고
    • Helical CT for nephrolithiasis and ureterolithiasis: Comparison of conventional and reduced radiation-dose techniques
    • Heneghan JP, McGuire KA, Leder RA, et al. Helical CT for nephrolithiasis and ureterolithiasis: comparison of conventional and reduced radiation-dose techniques. Radiology. 2003;229:575-580.
    • (2003) Radiology , vol.229 , pp. 575-580
    • Heneghan, J.P.1    McGuire, K.A.2    Leder, R.A.3
  • 9
    • 0034066174 scopus 로고    scopus 로고
    • Low-dose nonenhanced helical CT of renal colic: Assessment of ureteric stone detection and measurement of effective dose equivalent
    • Liu W, Esler SJ, Kenny BJ, et al. Low-dose nonenhanced helical CT of renal colic: assessment of ureteric stone detection and measurement of effective dose equivalent. Radiology. 2000;215:51-54.
    • (2000) Radiology , vol.215 , pp. 51-54
    • Liu, W.1    Esler, S.J.2    Kenny, B.J.3
  • 10
    • 0036236361 scopus 로고    scopus 로고
    • Detection of low-contrast objects: Experimental comparison of single- and multi-detector row CT with a phantom
    • Verdun FR, Denys A, Valley JF, et al. Detection of low-contrast objects: experimental comparison of single- and multi-detector row CT with a phantom. Radiology. 2002;223:426-431.
    • (2002) Radiology , vol.223 , pp. 426-431
    • Verdun, F.R.1    Denys, A.2    Valley, J.F.3
  • 11
    • 0038287683 scopus 로고    scopus 로고
    • Optimization of eight-element multi-detector row helical CT technology for evaluation of the abdomen
    • Gupta AK, Nelson RC, Johnson GA, et al. Optimization of eight-element multi-detector row helical CT technology for evaluation of the abdomen. Radiology. 2003;227:739-745.
    • (2003) Radiology , vol.227 , pp. 739-745
    • Gupta, A.K.1    Nelson, R.C.2    Johnson, G.A.3
  • 12
    • 84888854597 scopus 로고    scopus 로고
    • A computer-simulated liver phantom (virtual liver phantom) for multidetector CT evaluation
    • In press
    • Funama Y, Awai K, Miyazaki O, et al. A computer-simulated liver phantom (virtual liver phantom) for multidetector CT evaluation. Eur Radiol. In press.
    • Eur Radiol
    • Funama, Y.1    Awai, K.2    Miyazaki, O.3
  • 13
    • 0141518516 scopus 로고    scopus 로고
    • Receiver operating characteristic curves and their use in radiology
    • Obuchowski NA. Receiver operating characteristic curves and their use in radiology. Radiology. 2003;229:3-8.
    • (2003) Radiology , vol.229 , pp. 3-8
    • Obuchowski, N.A.1
  • 14
    • 0141618366 scopus 로고    scopus 로고
    • Diagnostic performance of liquid crystal and cathode-ray-tube monitors in brain computed tomography
    • Partan G, Mayrhofer R, Urban M, et al. Diagnostic performance of liquid crystal and cathode-ray-tube monitors in brain computed tomography. Eur Radiol. 2003;13:2397-2401.
    • (2003) Eur Radiol , vol.13 , pp. 2397-2401
    • Partan, G.1    Mayrhofer, R.2    Urban, M.3
  • 15
    • 0032812523 scopus 로고    scopus 로고
    • A computer simulation of wavelet noise reduction in computed tomography
    • Harpen MD. A computer simulation of wavelet noise reduction in computed tomography. Med Phys. 1999;26:1600-1606.
    • (1999) Med Phys , vol.26 , pp. 1600-1606
    • Harpen, M.D.1
  • 16
    • 0036839121 scopus 로고    scopus 로고
    • Clinical comparison of standard-dose and 50% reduced-dose abdominal CT: Effect on image quality
    • Kalra MK, Prasad S, Saini S, et al. Clinical comparison of standard-dose and 50% reduced-dose abdominal CT: effect on image quality. AJR Am J Roentgenol. 2002;179:1101-1106.
    • (2002) AJR Am J Roentgenol , vol.179 , pp. 1101-1106
    • Kalra, M.K.1    Prasad, S.2    Saini, S.3
  • 17
    • 0036838456 scopus 로고    scopus 로고
    • Computer-simulated radiation dose reduction for abdominal multidetector CT of pediatric patients
    • Frush DP, Slack CC, Hollingsworth CL, et al. Computer-simulated radiation dose reduction for abdominal multidetector CT of pediatric patients. AJR Am J Roentgenol. 2002;179:1107-1113.
    • (2002) AJR Am J Roentgenol , vol.179 , pp. 1107-1113
    • Frush, D.P.1    Slack, C.C.2    Hollingsworth, C.L.3
  • 18
    • 0031739421 scopus 로고    scopus 로고
    • Helical CT reconstruction with longitudinal filtration
    • Hu H, Shen Y. Helical CT reconstruction with longitudinal filtration. Med Phys. 1998;25:2130-2138.
    • (1998) Med Phys , vol.25 , pp. 2130-2138
    • Hu, H.1    Shen, Y.2
  • 20
    • 6344277475 scopus 로고    scopus 로고
    • Improvement of image quality of multislice spiral CT scans of the head and neck region using a raw data-based multidimensional adaptive filtering (MAF) technique
    • Baum U, Anders K, Steinbichler G, et al. Improvement of image quality of multislice spiral CT scans of the head and neck region using a raw data-based multidimensional adaptive filtering (MAF) technique. Eur Radiol. 2004;14:1873-1881.
    • (2004) Eur Radiol , vol.14 , pp. 1873-1881
    • Baum, U.1    Anders, K.2    Steinbichler, G.3
  • 21
    • 0037600583 scopus 로고    scopus 로고
    • Low-dose CT of the abdomen: Evaluation of image improvement with use of noise reduction filters pilot study
    • Kalra MK, Maher MM, Sahani DV, et al. Low-dose CT of the abdomen: evaluation of image improvement with use of noise reduction filters pilot study. Radiology. 2003;228:251-256.
    • (2003) Radiology , vol.228 , pp. 251-256
    • Kalra, M.K.1    Maher, M.M.2    Sahani, D.V.3
  • 22
  • 23
    • 0035052748 scopus 로고    scopus 로고
    • Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice, and cone-beam CT
    • Kachelriess M, Watzke O, Kalender WA. Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice, and cone-beam CT. Med Phys. 2001;28:475-490.
    • (2001) Med Phys , vol.28 , pp. 475-490
    • Kachelriess, M.1    Watzke, O.2    Kalender, W.A.3
  • 24
    • 0037372750 scopus 로고    scopus 로고
    • Multi-detector row CT: Radiation dose characteristics
    • Hamberg LM, Rhea JT, Hunter GJ, et al. Multi-detector row CT: radiation dose characteristics. Radiology. 2003;226:762-772.
    • (2003) Radiology , vol.226 , pp. 762-772
    • Hamberg, L.M.1    Rhea, J.T.2    Hunter, G.J.3
  • 25
    • 0037342616 scopus 로고    scopus 로고
    • Influence of phantom diameter, kVp and scan mode upon computed tomography dose index
    • Nickoloff EL, Dutta AK, Lu ZF. Influence of phantom diameter, kVp and scan mode upon computed tomography dose index. Med Phys. 2003;30:395-402.
    • (2003) Med Phys , vol.30 , pp. 395-402
    • Nickoloff, E.L.1    Dutta, A.K.2    Lu, Z.F.3
  • 26
    • 1642389455 scopus 로고    scopus 로고
    • Low-kilovoltage multi-detector row chest CT in adults: Feasibility and effect on image quality and iodine dose
    • Sigal-Cinqualbre AB, Hennequin R, Abada HT, et al. Low-kilovoltage multi-detector row chest CT in adults: feasibility and effect on image quality and iodine dose. Radiology. 2004;231:169-174.
    • (2004) Radiology , vol.231 , pp. 169-174
    • Sigal-Cinqualbre, A.B.1    Hennequin, R.2    Abada, H.T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.