메뉴 건너뛰기




Volumn 108, Issue 9, 2011, Pages 2011-2021

Cholesterol biosensors based on oxygen sensing alginate-silica microspheres

Author keywords

Alginate silica; Cholesterol biosensor; Microspheres; PtOEP dye

Indexed keywords

ALGINATE-SILICA; BIOSENSOR RESPONSE; CHOLESTEROL BIOSENSOR; CHOLESTEROL DETERMINATION; CHOLESTEROL OXIDASE; CORONARY HEART DISEASE; ENZYME ENCAPSULATION; FLUORIMETRIC; HYPERCHOLESTEROLEMIA; LAYER BY LAYER SELF ASSEMBLY; MESOPOROUS; METALLOPORPHYRINS; OBSTRUCTIVE JAUNDICE; OXYGEN-SENSING; PRECIPITATION METHODS; PTOEP DYE; REGRESSION COEFFICIENT; SELF-ASSEMBLED; STERN-VOLMER PLOT;

EID: 79960468975     PISSN: 00063592     EISSN: 10970290     Source Type: Journal    
DOI: 10.1002/bit.23143     Document Type: Article
Times cited : (28)

References (31)
  • 1
    • 75149181338 scopus 로고    scopus 로고
    • Highly sensitive amperometric cholesterol biosensor based on Pt-incorporated fullerene-like ZnO nanospheres
    • Ahmad M, Pan C, Gan L, Nawaz Z, Zhu J. 2010. Highly sensitive amperometric cholesterol biosensor based on Pt-incorporated fullerene-like ZnO nanospheres. J Phys Chem C 114: 243-250.
    • (2010) J Phys Chem C , vol.114 , pp. 243-250
    • Ahmad, M.1    Pan, C.2    Gan, L.3    Nawaz, Z.4    Zhu, J.5
  • 2
    • 38749101357 scopus 로고    scopus 로고
    • Recent advances in cholesterol biosensor
    • Arya SK, Datta M, Malhotra BD. 2008. Recent advances in cholesterol biosensor. Biosens Bioelectron 23(7): 1083-1100.
    • (2008) Biosens Bioelectron , vol.23 , Issue.7 , pp. 1083-1100
    • Arya, S.K.1    Datta, M.2    Malhotra, B.D.3
  • 3
    • 33750483280 scopus 로고    scopus 로고
    • Absorption and emission spectroscopic characterization of platinum-octaethyl-porphyrin (PtOEP)
    • Bansal AK, Holzer W, Penzkofer A, Tsuboi T. 2006. Absorption and emission spectroscopic characterization of platinum-octaethyl-porphyrin (PtOEP). Chem Phys 330: 118-129.
    • (2006) Chem Phys , vol.330 , pp. 118-129
    • Bansal, A.K.1    Holzer, W.2    Penzkofer, A.3    Tsuboi, T.4
  • 4
    • 34047140032 scopus 로고    scopus 로고
    • Development of cholesterol biosensor based on immobilized cholesterol esterase and cholesterol oxidase on oxygen electrode for the determination of total cholesterol in food samples
    • Basu AK, Chattopadhyay P, Roychoudhuri U, Chakraborty R. 2007. Development of cholesterol biosensor based on immobilized cholesterol esterase and cholesterol oxidase on oxygen electrode for the determination of total cholesterol in food samples. Bioelectrochemistry 70(2): 375-379.
    • (2007) Bioelectrochemistry , vol.70 , Issue.2 , pp. 375-379
    • Basu, A.K.1    Chattopadhyay, P.2    Roychoudhuri, U.3    Chakraborty, R.4
  • 6
    • 20444490675 scopus 로고    scopus 로고
    • Encapsulation of glucose oxidase and an oxygen-quenched fluorophore in polyelectrolyte-coated calcium alginate microspheres as optical glucose sensor systems
    • Brown JQ, Srivastava R, McShane MJ. 2005. Encapsulation of glucose oxidase and an oxygen-quenched fluorophore in polyelectrolyte-coated calcium alginate microspheres as optical glucose sensor systems. Biosens Bioelectron 21(1): 212-216.
    • (2005) Biosens Bioelectron , vol.21 , Issue.1 , pp. 212-216
    • Brown, J.Q.1    Srivastava, R.2    McShane, M.J.3
  • 7
    • 0347365821 scopus 로고    scopus 로고
    • Immobilization of glucose oxidase in chitosan gel beads
    • Ghanem A, Ghaly A. 2004. Immobilization of glucose oxidase in chitosan gel beads. J Appl Polym Sci 91: 861-866.
    • (2004) J Appl Polym Sci , vol.91 , pp. 861-866
    • Ghanem, A.1    Ghaly, A.2
  • 10
    • 0020060090 scopus 로고
    • Identification of multiple subclasses of plasma low density lipoproteins in normal humans
    • Krauss RM, Burke DJ. 1982. Identification of multiple subclasses of plasma low density lipoproteins in normal humans. J Lipid Res 23(1): 97-104.
    • (1982) J Lipid Res , vol.23 , Issue.1 , pp. 97-104
    • Krauss, R.M.1    Burke, D.J.2
  • 11
    • 0034213780 scopus 로고    scopus 로고
    • Co-immobilization of cholesterol oxidase and horseradish peroxidase in a sol-gel film
    • Kumar A, Malhotraa R, Malhotraa BD, Groverb SK. 2000. Co-immobilization of cholesterol oxidase and horseradish peroxidase in a sol-gel film. Anal Chim Acta 414(1-2): 43-50.
    • (2000) Anal Chim Acta , vol.414 , Issue.1-2 , pp. 43-50
    • Kumar, A.1    Malhotraa, R.2    Malhotraa, B.D.3    Groverb, S.K.4
  • 12
    • 0041529653 scopus 로고    scopus 로고
    • A cholesterol biosensor based on entrapment of cholesterol oxidase in a silicic sol-gel matrix at a Prussian blue modified electrode
    • Li J, Peng T, Peng Y. 2003. A cholesterol biosensor based on entrapment of cholesterol oxidase in a silicic sol-gel matrix at a Prussian blue modified electrode. Electroanalysis 15(12): 1031-1037.
    • (2003) Electroanalysis , vol.15 , Issue.12 , pp. 1031-1037
    • Li, J.1    Peng, T.2    Peng, Y.3
  • 13
    • 50949115269 scopus 로고    scopus 로고
    • Alginate-templated microcapsules carrying heparin via layer-by-layer self-assembly
    • Li J, Liu X, Zhu B, Shao Y, Zhao D, Yang X. 2008. Alginate-templated microcapsules carrying heparin via layer-by-layer self-assembly. IEEE 1420-1423.
    • (2008) IEEE , pp. 1420-1423
    • Li, J.1    Liu, X.2    Zhu, B.3    Shao, Y.4    Zhao, D.5    Yang, X.6
  • 14
    • 0346995404 scopus 로고    scopus 로고
    • Performance of four sources of cholesterol oxidase for serum cholesterol determination by the enzymatic endpoint method
    • Lolekha PH, Srisawasdi P, Jearanaikoon P, Wetprasit N, Sriwanthana B, Kroll MH. 2004. Performance of four sources of cholesterol oxidase for serum cholesterol determination by the enzymatic endpoint method. Clin Chim Acta 339(1-2): 135-145.
    • (2004) Clin Chim Acta , vol.339 , Issue.1-2 , pp. 135-145
    • Lolekha, P.H.1    Srisawasdi, P.2    Jearanaikoon, P.3    Wetprasit, N.4    Sriwanthana, B.5    Kroll, M.H.6
  • 16
    • 0031029284 scopus 로고    scopus 로고
    • Free cholesterol fiber-optic biosensor for serum samples with simplex optimization
    • Marazuelaa MD, Cuestaa B, Moreno-Bondi MC, Quejidob A. 1997. Free cholesterol fiber-optic biosensor for serum samples with simplex optimization. Biosens Bioelectron 12(3): 233-240.
    • (1997) Biosens Bioelectron , vol.12 , Issue.3 , pp. 233-240
    • Marazuelaa, M.D.1    Cuestaa, B.2    Moreno-Bondi, M.C.3    Quejidob, A.4
  • 17
    • 33646185060 scopus 로고    scopus 로고
    • Quantitative analysis of the sensitivity of porous silicon optical biosensors
    • Ouyang H, Striemer CC, Fauchet PM. 2006. Quantitative analysis of the sensitivity of porous silicon optical biosensors. Appl Phys Lett 88: 163108.
    • (2006) Appl Phys Lett , vol.88 , pp. 163108
    • Ouyang, H.1    Striemer, C.C.2    Fauchet, P.M.3
  • 18
    • 0001745377 scopus 로고
    • Phosphorescent complexes of porphyrin ketones: Optical properties and application to oxygen sensing
    • Papkovsky DB, Ponomarev GV, Trettnak W, O'Leary P. 1995. Phosphorescent complexes of porphyrin ketones: Optical properties and application to oxygen sensing. Anal Chem 67(22): 4112-4117.
    • (1995) Anal Chem , vol.67 , Issue.22 , pp. 4112-4117
    • Papkovsky, D.B.1    Ponomarev, G.V.2    Trettnak, W.3    O'Leary, P.4
  • 19
    • 4844221601 scopus 로고    scopus 로고
    • The sol-gel encapsulation of enzymes
    • Pierre AC. 2004. The sol-gel encapsulation of enzymes. Biocat Biotrans 22(3): 145-170.
    • (2004) Biocat Biotrans , vol.22 , Issue.3 , pp. 145-170
    • Pierre, A.C.1
  • 20
    • 0032816038 scopus 로고    scopus 로고
    • Cholesterol oxidase from Streptomyces hygroscopicus and Brevibacterium sterolicum: Effect of surfactants and organic solvents on activity
    • Pollegioni L, Gadda G, Ambrosius D, Ghisla S, Pilone MS. 1999. Cholesterol oxidase from Streptomyces hygroscopicus and Brevibacterium sterolicum: Effect of surfactants and organic solvents on activity. Biotechnol Appl Biochem 30(Pt 1): 27-33.
    • (1999) Biotechnol Appl Biochem , vol.30 , Issue.PART 1 , pp. 27-33
    • Pollegioni, L.1    Gadda, G.2    Ambrosius, D.3    Ghisla, S.4    Pilone, M.S.5
  • 21
    • 0034783792 scopus 로고    scopus 로고
    • Mesoporous and mesostructured materials for optical applications
    • Scott BJ, Wirnsberger G, Stucky GD. 2001. Mesoporous and mesostructured materials for optical applications. Chem Mater 13: 3140-3150.
    • (2001) Chem Mater , vol.13 , pp. 3140-3150
    • Scott, B.J.1    Wirnsberger, G.2    Stucky, G.D.3
  • 22
    • 33845656062 scopus 로고    scopus 로고
    • Immobilization of cholesterol esterase and cholesterol oxidase onto sol-gel films for application to cholesterol biosensor
    • Singhal R, Malhotra BD. 2007. Immobilization of cholesterol esterase and cholesterol oxidase onto sol-gel films for application to cholesterol biosensor. Anal Chim Acta 582(2): 335-343.
    • (2007) Anal Chim Acta , vol.582 , Issue.2 , pp. 335-343
    • Singhal, R.1    Malhotra, B.D.2
  • 23
    • 24144436632 scopus 로고    scopus 로고
    • Stable encapsulation of active enzyme by application of multilayer nanofilm coatings to alginate microspheres
    • Srivastava R, Brown JQ, Zhu H, McShane MJ. 2005. Stable encapsulation of active enzyme by application of multilayer nanofilm coatings to alginate microspheres. Macromol Biosci 5(8): 717-727.
    • (2005) Macromol Biosci , vol.5 , Issue.8 , pp. 717-727
    • Srivastava, R.1    Brown, J.Q.2    Zhu, H.3    McShane, M.J.4
  • 24
    • 33847217294 scopus 로고    scopus 로고
    • Microscale enzymatic optical biosensors using mass transport limiting nanofilms. 1. Fabrication and characterization using glucose as a model analyte
    • Stein EW, Grant PS, Zhu H, McShane MJ. 2007. Microscale enzymatic optical biosensors using mass transport limiting nanofilms. 1. Fabrication and characterization using glucose as a model analyte. Anal Chem 79(4): 1339-1348.
    • (2007) Anal Chem , vol.79 , Issue.4 , pp. 1339-1348
    • Stein, E.W.1    Grant, P.S.2    Zhu, H.3    McShane, M.J.4
  • 25
    • 0017386842 scopus 로고
    • Methods for the in vivo estimation of human cholesterol dynamics
    • Steven H, Quarfordt MD. 1977. Methods for the in vivo estimation of human cholesterol dynamics. Am J Clin Nutr 30: 967-974.
    • (1977) Am J Clin Nutr , vol.30 , pp. 967-974
    • Steven, H.1    Quarfordt, M.D.2
  • 26
    • 0037377014 scopus 로고    scopus 로고
    • Co-immobilization of cholesterol esterase, cholesterol oxidase and peroxidase onto alkylamine glass beads for measurement of total cholesterol in serum
    • Suman S, Pundir CS. 2003. Co-immobilization of cholesterol esterase, cholesterol oxidase and peroxidase onto alkylamine glass beads for measurement of total cholesterol in serum. Curr Appl Phys 3: 129-133.
    • (2003) Curr Appl Phys , vol.3 , pp. 129-133
    • Suman, S.1    Pundir, C.S.2
  • 27
    • 0042977468 scopus 로고    scopus 로고
    • Hydrogel network entrapping cholesterol oxidase and octadecylsilica for optical biosensing in hydrophobic organic or aqueous micelle solvents
    • Wu XJ, Choi MM. 2003. Hydrogel network entrapping cholesterol oxidase and octadecylsilica for optical biosensing in hydrophobic organic or aqueous micelle solvents. Anal Chem 75(16): 4019-4027.
    • (2003) Anal Chem , vol.75 , Issue.16 , pp. 4019-4027
    • Wu, X.J.1    Choi, M.M.2
  • 28
    • 33748747471 scopus 로고    scopus 로고
    • Highly sensitive optical fiber oxygen sensor using Pt(II) complex embedded in sol-gel matrices
    • Yeha T, Chub C, Lo Y. 2006. Highly sensitive optical fiber oxygen sensor using Pt(II) complex embedded in sol-gel matrices. Sens Actuators B Chem 119(2): 701-707.
    • (2006) Sens Actuators B Chem , vol.119 , Issue.2 , pp. 701-707
    • Yeha, T.1    Chub, C.2    Lo, Y.3
  • 29
    • 36849084522 scopus 로고    scopus 로고
    • Enhanced photoluminescence of oxygen sensing films through doping with high dielectric constant particles
    • Zhou Z, Shinar R, Allison AJ, Shinar J. 2007. Enhanced photoluminescence of oxygen sensing films through doping with high dielectric constant particles. Adv Funct Mater 17: 3530-3537.
    • (2007) Adv Funct Mater , vol.17 , pp. 3530-3537
    • Zhou, Z.1    Shinar, R.2    Allison, A.J.3    Shinar, J.4
  • 30
    • 27944454801 scopus 로고    scopus 로고
    • Combined physical and chemical immobilization of glucose oxidase in alginate microspheres improves stability of encapsulation and activity
    • Zhu H, Srivastava R, Brown JQ, McShane MJ. 2005a. Combined physical and chemical immobilization of glucose oxidase in alginate microspheres improves stability of encapsulation and activity. Bioconjug Chem 16(6): 1451-1458.
    • (2005) Bioconjug Chem , vol.16 , Issue.6 , pp. 1451-1458
    • Zhu, H.1    Srivastava, R.2    Brown, J.Q.3    McShane, M.J.4
  • 31
    • 22944475521 scopus 로고    scopus 로고
    • Spontaneous loading of positively charged macromolecules into alginate-templated polyelectrolyte multilayer microcapsules
    • Zhu H, Srivastava R, McShane MJ. 2005b. Spontaneous loading of positively charged macromolecules into alginate-templated polyelectrolyte multilayer microcapsules. Biomacromolecules 6(4): 2221-2228.
    • (2005) Biomacromolecules , vol.6 , Issue.4 , pp. 2221-2228
    • Zhu, H.1    Srivastava, R.2    McShane, M.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.