메뉴 건너뛰기




Volumn 339, Issue 1-2, 2004, Pages 135-145

Performance of four sources of cholesterol oxidase for serum cholesterol determination by the enzymatic endpoint method

Author keywords

Brevibacterium; Cellulomonas; Enzymatic endpoint method; Pseudomonas fluorescens; Serum cholesterol; Streptomyces

Indexed keywords

BACTERIAL ENZYME; BILIRUBIN; CHOLESTEROL; CHOLESTEROL OXIDASE; REAGENT;

EID: 0346995404     PISSN: 00098981     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.cccn.2003.10.005     Document Type: Article
Times cited : (18)

References (17)
  • 2
    • 0015719916 scopus 로고
    • Preparation and properties of cholesterol oxidase from Nocardia sp. and its application to the enzymic assay of total cholesterol in serum
    • Richmond U. Preparation and properties of cholesterol oxidase from Nocardia sp. and its application to the enzymic assay of total cholesterol in serum. Clin. Chem. 19:1973;1350-1356.
    • (1973) Clin. Chem. , vol.19 , pp. 1350-1356
    • Richmond, U.1
  • 3
    • 0018747681 scopus 로고
    • Enzymatic assay of total cholesterol involving chemical or enzymic hydrolysis - A comparison of methods
    • Deacon A.C., Dawson J.G. Enzymatic assay of total cholesterol involving chemical or enzymic hydrolysis - a comparison of methods. Clin. Chem. 25:1979;976-984.
    • (1979) Clin. Chem. , vol.25 , pp. 976-984
    • Deacon, A.C.1    Dawson, J.G.2
  • 4
    • 0029951137 scopus 로고    scopus 로고
    • Optimization studies of components in enzymatic cholesterol reagents containing cholesterol oxidase from Nocardia erythropolis, Streptomyces sp, or Pseudomonas fluorescens
    • Lolekha P.H., Teerajetkul Y. Optimization studies of components in enzymatic cholesterol reagents containing cholesterol oxidase from Nocardia erythropolis, Streptomyces sp, or Pseudomonas fluorescens. J. Clin. Lab. Anal. 10:1996;167-176.
    • (1996) J. Clin. Lab. Anal. , vol.10 , pp. 167-176
    • Lolekha, P.H.1    Teerajetkul, Y.2
  • 5
    • 0017107420 scopus 로고
    • Comparative studies on cholesterol oxidase from different sources
    • Noma A., Nakayama K. Comparative studies on cholesterol oxidase from different sources. Clin. Chim. Acta. 73:1976;487-496.
    • (1976) Clin. Chim. Acta , vol.73 , pp. 487-496
    • Noma, A.1    Nakayama, K.2
  • 6
    • 0028939982 scopus 로고
    • Direct measurement of high-density lipoprotein cholesterol in serum with polyethyleen glycol-modified enzymes and sulfated-cyclodextrin
    • Sugiuchi H., Uji Y., Okabe H., Irie T., Uekama K., Kayahara N.et al. Direct measurement of high-density lipoprotein cholesterol in serum with polyethyleen glycol-modified enzymes and sulfated-cyclodextrin. Clin. Chem. 41:1995;717-723.
    • (1995) Clin. Chem. , vol.41 , pp. 717-723
    • Sugiuchi, H.1    Uji, Y.2    Okabe, H.3    Irie, T.4    Uekama, K.5    Kayahara, N.6
  • 7
    • 0022556123 scopus 로고
    • Enzymatic methods for quantification of lipoprotein lipids
    • Warnick G.R. Enzymatic methods for quantification of lipoprotein lipids. Methods Enzymol. 129:1986;101-123.
    • (1986) Methods Enzymol. , vol.129 , pp. 101-123
    • Warnick, G.R.1
  • 8
    • 0026492937 scopus 로고
    • Streptomyces: A superior sources of cholesterol oxidase used in serum cholesterol assay
    • Lolekha P.H., Jantaveesirirat Y. Streptomyces: a superior sources of cholesterol oxidase used in serum cholesterol assay. J. Clin. Lab. Anal. 6:1992;705-709.
    • (1992) J. Clin. Lab. Anal. , vol.6 , pp. 705-709
    • Lolekha, P.H.1    Jantaveesirirat, Y.2
  • 9
    • 85030932445 scopus 로고    scopus 로고
    • Cholesterol reagent product No. 1.07114 E. Merck, 64271 Darmstadt, Germany.
    • Cholesterol, Merck Mega. Cholesterol reagent product No. 1.07114 E. Merck, 64271 Darmstadt, Germany.
  • 10
    • 85030928376 scopus 로고    scopus 로고
    • Part No. 9.71007.9221 Merck KgaA D-64271 Darmstadt, Germany.
    • Instruction Manual, Merck MEGA, 4th ed. Part No. 9.71007.9221 Merck KgaA D-64271 Darmstadt, Germany.
    • Merck MEGA, 4th Ed.
  • 11
    • 84878355568 scopus 로고    scopus 로고
    • Evaluation of the linearity of quantitative measurement procedures: A statistical approach
    • Wayne, PA: NCCLS
    • National Committee for Clinical Laboratory Standards Evaluation of the linearity of quantitative measurement procedures: a statistical approach. Approved Guideline. Document EP6-A. 2003;NCCLS, Wayne, PA.
    • (2003) Approved Guideline. Document EP6-A
  • 12
    • 79960137797 scopus 로고
    • National Institutes of Health Recommendations for improving cholesterol measurement: A report from the Laboratory Standardization Panel of the National Cholesterol Education Program
    • Bethesda, MD: National Institutes of Health
    • National Institutes of Health Recommendations for improving cholesterol measurement: a report from the Laboratory Standardization Panel of the National Cholesterol Education Program. NIH Publication. vol. 90-2964:1990;National Institutes of Health, Bethesda, MD.
    • (1990) NIH Publication , vol.2964
  • 13
    • 0027960559 scopus 로고
    • Interference with clinical laboratory analyses
    • Kroll M.H., Elin R.S. Interference with clinical laboratory analyses. Clin. Chem. 40:1994;1995-2005.
    • (1994) Clin. Chem. , vol.40 , pp. 1995-2005
    • Kroll, M.H.1    Elin, R.S.2
  • 14
    • 85030925814 scopus 로고    scopus 로고
    • Third report of the Expert Panel on detection, evaluation, and treatment of high blood cholestrerol in adults
    • Bethesda, MD: National Institutes of Health
    • National Institutes of Health Third report of the Expert Panel on detection, evaluation, and treatment of high blood cholestrerol in adults. NIH Publication. vol. 01-3670:2001;National Institutes of Health, Bethesda, MD.
    • (2001) NIH Publication , vol.1
    • Institutes Of Health, N.1
  • 15
    • 0033798463 scopus 로고    scopus 로고
    • The haemolytic, Icteric and lipemic sample recommendation regarding their recognition and prevention of clinically relevant interferences
    • Guder W.G., Fonseca-Wollheim F.D., Wuppertal W.H., Schmitt Y.M., Gorlitz G.T., Wisser H., Zawta B. The haemolytic, Icteric and lipemic sample recommendation regarding their recognition and prevention of clinically relevant interferences. J. Lab. Med. 24:2000;357-364.
    • (2000) J. Lab. Med. , vol.24 , pp. 357-364
    • Guder, W.G.1    Fonseca-Wollheim, F.D.2    Wuppertal, W.H.3    Schmitt, Y.M.4    Gorlitz, G.T.5    Wisser, H.6    Zawta, B.7
  • 16
    • 0017355434 scopus 로고
    • Interfernce with the enzyme measurement of cholesterol in serum by use of five reagent kits
    • Pesce M.A., Bodourian S.H. Interfernce with the enzyme measurement of cholesterol in serum by use of five reagent kits. Clin. Chem. 23:1977;751-760.
    • (1977) Clin. Chem. , vol.23 , pp. 751-760
    • Pesce, M.A.1    Bodourian, S.H.2
  • 17
    • 0041292015 scopus 로고    scopus 로고
    • Labsystem Oy. Pulttitie 9-11, 00810 Helsinki 81, Finland.
    • Operation Manual, Labsystem Oy. Pulttitie 9-11, 00810 Helsinki 81, Finland.
    • Operation Manual


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.