메뉴 건너뛰기




Volumn 12, Issue 3, 1997, Pages 233-240

Free cholesterol fiber-optic biosensor for serum samples with simplex optimization

Author keywords

biosensor; cholesterol; optical fiber; oxygen optode; sensor; simplex

Indexed keywords

CATALYSTS; CHOLESTEROL; ENZYMES; FIBER OPTIC SENSORS; LUMINESCENCE; OPTIMIZATION; OXIDATION; RUTHENIUM COMPOUNDS; SILICONES;

EID: 0031029284     PISSN: 09565663     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0956-5663(97)85341-9     Document Type: Article
Times cited : (59)

References (31)
  • 2
    • 0001130105 scopus 로고
    • 2 reaction using peroxidase immobilized on new synthetic membranes
    • 2 reaction using peroxidase immobilized on new synthetic membranes. Anal. Lett., 30(2), 317-326.
    • (1987) Anal. Lett. , vol.30 , Issue.2 , pp. 317-326
    • Blum, L.J.1    Plaza, J.M.2    Coulet, P.R.3
  • 3
    • 0000870146 scopus 로고
    • Enzymatic flow injection analysis in nonaqueous media
    • Braco, L., Darós, J.A. & de la Guardia, M. (1992). Enzymatic flow injection analysis in nonaqueous media. Anal. Chem., 64, 129-133.
    • (1992) Anal. Chem. , vol.64 , pp. 129-133
    • Braco, L.1    Darós, J.A.2    De La Guardia, M.3
  • 4
    • 0027440964 scopus 로고
    • A carrageenan hydrogel stabilized colloidal gold multi-enzyme biosensor electrode utilizing immobilized horseradish peroxidase and cholesterol oxidase/cholesterol esterase to detect cholesterol in serum and whole blood
    • Crumbliss, A.L., Stonehuerner, J.G., Henkens, R.W., Zhao, J. & O'Daly, J.P. (1993). A carrageenan hydrogel stabilized colloidal gold multi-enzyme biosensor electrode utilizing immobilized horseradish peroxidase and cholesterol oxidase/cholesterol esterase to detect cholesterol in serum and whole blood. Biosensors & Bioelectronics, 8, 331-337.
    • (1993) Biosensors & Bioelectronics , vol.8 , pp. 331-337
    • Crumbliss, A.L.1    Stonehuerner, J.G.2    Henkens, R.W.3    Zhao, J.4    O'Daly, J.P.5
  • 5
    • 0000485722 scopus 로고
    • Simplex optimization of variables in analytical chemistry
    • Deming, S.N. & Morgan, S.L. (1973). Simplex optimization of variables in analytical chemistry. Anal. Chem., 45, 278A.
    • (1973) Anal. Chem. , vol.45
    • Deming, S.N.1    Morgan, S.L.2
  • 6
    • 0027211962 scopus 로고
    • Cholesterol sensor based on electrodeposition of catalytic palladium particles
    • Dong, S., Deng, Q. & Cheng, G. (1993). Cholesterol sensor based on electrodeposition of catalytic palladium particles. Anal. Chim. Acta, 279, 235-240.
    • (1993) Anal. Chim. Acta , vol.279 , pp. 235-240
    • Dong, S.1    Deng, Q.2    Cheng, G.3
  • 7
    • 0023232393 scopus 로고
    • Determination of total cholesterol in serum by flow injection analysis with immobilized enzymes
    • Fernández-Romero, J.M., Luque de Castro, M.D. & Valcárcel, M. (1987). Determination of total cholesterol in serum by flow injection analysis with immobilized enzymes. Clin. Chim. Acta, 167, 97-104.
    • (1987) Clin. Chim. Acta , vol.167 , pp. 97-104
    • Fernández-Romero, J.M.1    Luque De Castro, M.D.2    Valcárcel, M.3
  • 8
    • 84951400121 scopus 로고
    • An organic phase enzyme electrode for cholesterol
    • Hall, G.F. & Turner, P.F. (1991). An organic phase enzyme electrode for cholesterol. Anal. Lett., 24(8), 1375-1388.
    • (1991) Anal. Lett. , vol.24 , Issue.8 , pp. 1375-1388
    • Hall, G.F.1    Turner, P.F.2
  • 9
    • 0016774082 scopus 로고
    • Differential pulse polarographic determination of some carcinogenic nitrosamines
    • Hasebe, K. & Osteryoung, J. (1975). Differential pulse polarographic determination of some carcinogenic nitrosamines. Anal. Chem., 47(14), 2412-2417.
    • (1975) Anal. Chem. , vol.47 , Issue.14 , pp. 2412-2417
    • Hasebe, K.1    Osteryoung, J.2
  • 10
    • 0016619518 scopus 로고
    • Fluorometric enzymatic determination of total cholesterol in serum
    • Huang, H., Kuan, J.W. & Guilbault, G.G. (1975). Fluorometric enzymatic determination of total cholesterol in serum. Clin. Chem., 21(11), 1605-1608.
    • (1975) Clin. Chem. , vol.21 , Issue.11 , pp. 1605-1608
    • Huang, H.1    Kuan, J.W.2    Guilbault, G.G.3
  • 11
    • 0000832469 scopus 로고
    • Amperometric determination of total cholesterol in serum with use of immobilized cholesterol esterase and cholesterol oxidase
    • Karube, Y., Hara, K., Matsuoka, H. & Suzuki, S. (1982). Amperometric determination of total cholesterol in serum with use of immobilized cholesterol esterase and cholesterol oxidase. Anal. Chim. Acta, 139, 127-132.
    • (1982) Anal. Chim. Acta , vol.139 , pp. 127-132
    • Karube, Y.1    Hara, K.2    Matsuoka, H.3    Suzuki, S.4
  • 12
    • 0028205050 scopus 로고
    • Flow-injection analysis for total cholesterol with photometric detection
    • Krug, A., Göbel, R. & Kellner, R. (1994). Flow-injection analysis for total cholesterol with photometric detection. Anal. Chim. Acta, 287, 59-64.
    • (1994) Anal. Chim. Acta , vol.287 , pp. 59-64
    • Krug, A.1    Göbel, R.2    Kellner, R.3
  • 13
    • 0026503647 scopus 로고
    • Enzyme-based fiber-optic device for the determination of total and free cholesterol
    • Krug, A., Suleiman, A.A. & Guilbault, G.G. (1992). Enzyme-based fiber-optic device for the determination of total and free cholesterol. Anal. Chim. Acta, 256, 263-268.
    • (1992) Anal. Chim. Acta, 256 , pp. 263-268
    • Krug, A.1    Suleiman, A.A.2    Guilbault, G.G.3
  • 14
    • 0028313712 scopus 로고
    • Fabrication and characterization of a screen-printed, disposable, amperometric cholesterol biosensor
    • Markas, A., Gilmartin, T. & Hart, J.P. (1994). Fabrication and characterization of a screen-printed, disposable, amperometric cholesterol biosensor. Analyst, 119, 2331-2336.
    • (1994) Analyst , vol.119 , pp. 2331-2336
    • Markas, A.1    Gilmartin, T.2    Hart, J.P.3
  • 15
    • 0000114760 scopus 로고
    • Determination of cholesterol by flow injection analysis with immobilized cholesterol oxidase
    • Masoom, M. & Townshend, A. (1985). Determination of cholesterol by flow injection analysis with immobilized cholesterol oxidase. Anal. Chim. Acta, 174, 293-297.
    • (1985) Anal. Chim. Acta , vol.174 , pp. 293-297
    • Masoom, M.1    Townshend, A.2
  • 16
    • 0026519294 scopus 로고
    • Temperature enhanced chemiluminescence for determination of cholesterol
    • Mike, J.H. & Cleland, J.J. (1992). Temperature enhanced chemiluminescence for determination of cholesterol. Anal. Chim. Acta, 259, 73-78.
    • (1992) Anal. Chim. Acta , vol.259 , pp. 73-78
    • Mike, J.H.1    Cleland, J.J.2
  • 18
    • 33847805632 scopus 로고
    • Simplex optimization of analytical methods
    • Morgan, S.L. & Deming, S.N. (1974). Simplex optimization of analytical methods. Anal. Chem., 46, 1170.
    • (1974) Anal. Chem. , vol.46 , pp. 1170
    • Morgan, S.L.1    Deming, S.N.2
  • 19
    • 0027918227 scopus 로고
    • Determination of cholesterol and cholesterol ester with novel enzyme microsensors
    • Motonaka, J. & Faulkner, L.R. (1993). Determination of cholesterol and cholesterol ester with novel enzyme microsensors. Anal. Chem., 65, 3258-3261.
    • (1993) Anal. Chem. , vol.65 , pp. 3258-3261
    • Motonaka, J.1    Faulkner, L.R.2
  • 20
    • 0017226945 scopus 로고
    • Polarographic method for rapid microdetermination of cholesterol with cholesterol esterase and cholesterol oxidase
    • Noma, A. & Nakayama, K. (1976). Polarographic method for rapid microdetermination of cholesterol with cholesterol esterase and cholesterol oxidase. Clin. Chem., 22(3), 336-340.
    • (1976) Clin. Chem. , vol.22 , Issue.3 , pp. 336-340
    • Noma, A.1    Nakayama, K.2
  • 21
    • 84989457257 scopus 로고
    • New binuclear hetrocyclic ligands sharing an α-diimine moiety and their ruthenium(II) trischelates
    • Orellana, G., Alvarez-Ibarra, C. & Quiroga, M.L. (1988). New binuclear hetrocyclic ligands sharing an α-diimine moiety and their ruthenium(II) trischelates. Bull. Soc. Chim. Belg., 97, 731-741.
    • (1988) Bull. Soc. Chim. Belg. , vol.97 , pp. 731-741
    • Orellana, G.1    Alvarez-Ibarra, C.2    Quiroga, M.L.3
  • 22
    • 84959981533 scopus 로고
    • Enzymatic assay by flow injection analysis with detection by chemiluminescence: Determination of glucose, creatinine, free cholesterol and lactic acid using an integrated FIA microconduit
    • Petersson, B.A., Hansen, E.H. & Ruzicka, J. (1986). Enzymatic assay by flow injection analysis with detection by chemiluminescence: determination of glucose, creatinine, free cholesterol and lactic acid using an integrated FIA microconduit. Anal. Lett., 19(5&6), 649-665.
    • (1986) Anal. Lett. , vol.19 , Issue.5-6 , pp. 649-665
    • Petersson, B.A.1    Hansen, E.H.2    Ruzicka, J.3
  • 23
    • 21344498135 scopus 로고
    • Application of the simplex method for optimization of the analytical methods
    • Rózycki, C. (1993). Application of the simplex method for optimization of the analytical methods. Chem. Anal., 38, 381-398.
    • (1993) Chem. Anal. , vol.38 , pp. 381-398
    • Rózycki, C.1
  • 24
    • 0002333727 scopus 로고
    • Determination of cholesterol with a laboratory-built chemiluminescence system
    • Taniguchi, A., Hayashi, Y. & Yuki, H. (1986). Determination of cholesterol with a laboratory-built chemiluminescence system. Anal. Chim. Acta, 188, 95-100.
    • (1986) Anal. Chim. Acta , vol.188 , pp. 95-100
    • Taniguchi, A.1    Hayashi, Y.2    Yuki, H.3
  • 26
    • 0024098914 scopus 로고
    • Fiber optic glucose biosensor with an oxygen optrode as the transducer
    • Trettnak, W., Leiner, M.J.P. & Wolfbeis, O.S. (1988). Fiber optic glucose biosensor with an oxygen optrode as the transducer. Analyst, 113, 1519-1523.
    • (1988) Analyst , vol.113 , pp. 1519-1523
    • Trettnak, W.1    Leiner, M.J.P.2    Wolfbeis, O.S.3
  • 27
    • 84987532044 scopus 로고
    • Cholesterol biosensors prepared by electropolymerization of pyrrole
    • Trettnak, W., Lionti, I. & Mascini, M. (1993). Cholesterol biosensors prepared by electropolymerization of pyrrole. Electroanalysis, 5, 753-763.
    • (1993) Electroanalysis , vol.5 , pp. 753-763
    • Trettnak, W.1    Lionti, I.2    Mascini, M.3
  • 28
    • 0025186556 scopus 로고
    • A fiberoptic cholesterol biosensor with an oxygen optrode as the transducer
    • Trettnak, W. & Wolfbeis, O.S. (1990). A fiberoptic cholesterol biosensor with an oxygen optrode as the transducer. Anal. Biochem., 184, 124-127.
    • (1990) Anal. Biochem. , vol.184 , pp. 124-127
    • Trettnak, W.1    Wolfbeis, O.S.2
  • 29
    • 0000241670 scopus 로고
    • Enzymatic reactor/room-temperature phosphorescence sensor system for cholesterol determination in organic solvents
    • Valencia-González, M.J. & Diaz-Garcia, M.E. (1994). Enzymatic reactor/room-temperature phosphorescence sensor system for cholesterol determination in organic solvents. Anal. Chem., 66, 2726-2731.
    • (1994) Anal. Chem. , vol.66 , pp. 2726-2731
    • Valencia-González, M.J.1    Diaz-Garcia, M.E.2
  • 30
    • 0028114035 scopus 로고
    • Amperometric flow-injection determination of glucose, urate and cholesterol in blood serum by using some immobilized enzyme reactors and a poly(1,2-diaminobenzene)-coated platinum electrode
    • Yao, T., Satomura, M. & Nakahara, T. (1994). Amperometric flow-injection determination of glucose, urate and cholesterol in blood serum by using some immobilized enzyme reactors and a poly(1,2-diaminobenzene)-coated platinum electrode. Anal. Chim. Acta, 296, 271-276.
    • (1994) Anal. Chim. Acta , vol.296 , pp. 271-276
    • Yao, T.1    Satomura, M.2    Nakahara, T.3
  • 31
    • 0000224717 scopus 로고
    • Some observations on cholesterol measurements in the clinical laboratory
    • Zak, B. & Artiss, J.D. (1990). Some observations on cholesterol measurements in the clinical laboratory. Microchem. J., 41, 251-270.
    • (1990) Microchem. J. , vol.41 , pp. 251-270
    • Zak, B.1    Artiss, J.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.