Volumn 88, Issue 7, 2011, Pages 843-849

Comparison between tonopachy and other tonometric and pachymetric devices

Author keywords

central corneal thickness; Goldmann applanation tonometer; intraocular pressure; Pentacam; Tonopachy; ultrasound pachymetry

Indexed keywords

CENTRAL CORNEAL THICKNESS; GOLDMANN APPLANATION TONOMETER; INTRA OCULAR PRESSURE; PENTACAM; TONOPACHY; ULTRASOUND PACHYMETRY;

EID: 79960355414     PISSN: 10405488     EISSN: None     Source Type: Journal    
DOI: 10.1097/OPX.0b013e31821896f1     Document Type: Article
Times cited : (17)

References (30)
  • 1
    • 36448970833 scopus 로고    scopus 로고
    • Central corneal thickness measurements in unoperated eyes and eyes after PRK for myopia using Pentacam, Orbscan II, and ultrasonic pachymetry
    • Kim SW, Byun YJ, Kim EK, Kim TI. Central corneal thickness measurements in unoperated eyes and eyes after PRK for myopia using Pentacam, Orbscan II, and ultrasonic pachymetry. J Refract Surg 2007;23:888-94.
    • (2007) J Refract Surg , vol.23 , pp. 888-894
    • Kim, S.W.1    Byun, Y.J.2    Kim, E.K.3    Kim, T.I.4
  • 3
    • 27744519845 scopus 로고    scopus 로고
    • Clinical comparison of contour and applanation tonometry and their relationship to pachymetry
    • DOI 10.1001/archopht.123.11.1532
    • Kniestedt C, Lin S, Choe J, Bostrom A, Nee M, Stamper RL. Clinical comparison of contour and applanation tonometry and their relationship to pachymetry. Arch Ophthalmol 2005;123:1532-7. (Pubitemid 41626689)
    • (2005) Archives of Ophthalmology , vol.123 , Issue.11 , pp. 1532-1537
    • Kniestedt, C.1    Lin, S.2    Choe, J.3    Bostrom, A.4    Nee, M.5    Stamper, R.L.6
  • 5
    • 0036822851 scopus 로고    scopus 로고
    • Reduction of intraocular pressure and glaucoma progression: Results from the Early Manifest Glaucoma Trial
    • Heijl A, Leske MC, Bengtsson B, Hyman L, Hussein M. Reduction of intraocular pressure and glaucoma progression: Results from the Early Manifest Glaucoma Trial. Arch Ophthalmol 2002;120: 1268-79. (Pubitemid 36105431)
    • (2002) Archives of Ophthalmology , vol.120 , Issue.10 , pp. 1268-1279
    • Heijl, A.1    Leske, M.C.2    Bengtsson, B.3    Hyman, L.4    Bengtsson, B.5    Hussein, M.6
  • 6
    • 79960376438 scopus 로고    scopus 로고
    • TM NT-530P Brochure. Gamagori, Japan: Nidek
    • TM NT-530P Brochure. Gamagori, Japan: Nidek; 2009.
  • 7
    • 34247239221 scopus 로고    scopus 로고
    • Recent advances in ophthalmic anterior segment imaging: A new era for ophthalmic diagnosis?
    • DOI 10.1136/bjo.2006.103408
    • Konstantopoulos A, Hossain P, Anderson DF. Recent advances in ophthalmic anterior segment imaging: A new era for ophthalmic diagnosis? Br J Ophthalmol 2007;91:551-7. (Pubitemid 46623694)
    • (2007) British Journal of Ophthalmology , vol.91 , Issue.4 , pp. 551-557
    • Konstantopoulos, A.1    Hossain, P.2    Anderson, D.F.3
  • 8
    • 34250698061 scopus 로고    scopus 로고
    • Measuring the cornea: The latest developments in corneal topography
    • DOI 10.1097/ICU.0b013e3281ca7121, PII 0005573520070700000010
    • Swartz T, Marten L, Wang M. Measuring the cornea: The latest developments in corneal topography. Curr Opin Ophthalmol 2007;18: 325-33. (Pubitemid 46955300)
    • (2007) Current Opinion in Ophthalmology , vol.18 , Issue.4 , pp. 325-333
    • Swartz, T.1    Marten, L.2    Wang, M.3
  • 11
    • 4444279897 scopus 로고    scopus 로고
    • Clinical significance of central corneal thickness in the management of glaucoma
    • DOI 10.1001/archopht.122.9.1270
    • Shih CY, Graff Zivin JS, Trokel SL, Tsai JC. Clinical significance of central corneal thickness in the management of glaucoma. Arch Ophthalmol 2004;122:1270-5. (Pubitemid 39180846)
    • (2004) Archives of Ophthalmology , vol.122 , Issue.9 , pp. 1270-1275
    • Shih, C.Y.1    Zivin, J.S.G.2    Trokel, S.L.3    Tsai, J.C.4
  • 13
    • 33646906826 scopus 로고    scopus 로고
    • Comparison of central corneal thickness measurements by rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit corneal topography
    • DOI 10.1016/j.ophtha.2006.01.063, PII S0161642006002806
    • Amano S, Honda N, Amano Y, Yamagami S, Miyai T, Samejima T, Ogata M, Miyata K. Comparison of central corneal thickness measurements by rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit corneal topography. Ophthalmology 2006;113: 937-41. (Pubitemid 43795239)
    • (2006) Ophthalmology , vol.113 , Issue.6 , pp. 937-941
    • Amano, S.1    Honda, N.2    Amano, Y.3    Yamagami, S.4    Miyai, T.5    Samejima, T.6    Ogata, M.7    Miyata, K.8
  • 14
    • 27144479245 scopus 로고    scopus 로고
    • Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry
    • DOI 10.1016/j.jcrs.2005.03.058, PII S088633500500430X
    • Barkana Y, Gerber Y, Elbaz U, Schwartz S, Ken-Dror G, Avni I, Zadok D. Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry. J Cataract Refract Surg 2005;31:1729-35. (Pubitemid 41503429)
    • (2005) Journal of Cataract and Refractive Surgery , vol.31 , Issue.9 , pp. 1729-1735
    • Barkana, Y.1    Gerber, Y.2    Elbaz, U.3    Schwartz, S.4    Ken-Dror, G.5    Avni, I.6    Zadok, D.7
  • 15
    • 33847257295 scopus 로고    scopus 로고
    • Comparison of Pentacam Scheimpflug camera with ultrasound pachymetry and noncontact specular microscopy in measuring central corneal thickness
    • DOI 10.1080/02713680601115010, PII 771355642
    • Fujioka M, Nakamura M, Tatsumi Y, Kusuhara A, Maeda H, Negi A. Comparison of Pentacam Scheimpflug camera with ultrasound pachymetry and noncontact specular microscopy in measuring central corneal thickness. Curr Eye Res 2007;32:89-94. (Pubitemid 46328423)
    • (2007) Current Eye Research , vol.32 , Issue.2 , pp. 89-94
    • Fujioka, M.1    Nakamura, M.2    Tatsumi, Y.3    Kusuhara, A.4    Maeda, H.5    Negi, A.6
  • 16
    • 33646143320 scopus 로고    scopus 로고
    • Corneal pachymetry mapping with highspeed optical coherence tomography
    • Li Y, Shekhar R, Huang D. Corneal pachymetry mapping with highspeed optical coherence tomography. Ophthalmology 2006;113: 792-9.
    • (2006) Ophthalmology , vol.113 , pp. 792-799
    • Li, Y.1    Shekhar, R.2    Huang, D.3
  • 17
    • 66149149508 scopus 로고    scopus 로고
    • Repeatability of corneal thickness measured using an Oculus Pentacam
    • Miranda MA, Radhakrishnan H, O'Donnell C. Repeatability of corneal thickness measured using an Oculus Pentacam. Optom Vis Sci 2009;86:266-72.
    • (2009) Optom Vis Sci , vol.86 , pp. 266-272
    • Miranda, M.A.1    Radhakrishnan, H.2    O'Donnell, C.3
  • 18
    • 28044436542 scopus 로고    scopus 로고
    • Agreement and repeatability of central thickness measurement in normal corneas using ultrasound pachymetry and the OCULUS Pentacam
    • DOI 10.1097/01.ico.0000157422.01146.e9
    • O'Donnell C, Maldonado-Codina C. Agreement and repeatability of central thickness measurement in normal corneas using ultrasound pachymetry and the OCULUS Pentacam. Cornea 2005;24:920-4. (Pubitemid 41688522)
    • (2005) Cornea , vol.24 , Issue.8 , pp. 920-924
    • O'Donnell, C.1    Maldonado-Codina, C.2
  • 19
    • 67249126267 scopus 로고    scopus 로고
    • Central and peripheral corneal thickness measured with optical coherence tomography, Scheimpflug imaging, and ultrasound pachymetry in normal, keratoconus-suspect, and post-laser in situ keratomileusis eyes
    • Prospero Ponce CM, Rocha KM, Smith SD, Krueger RR. Central and peripheral corneal thickness measured with optical coherence tomography, Scheimpflug imaging, and ultrasound pachymetry in normal, keratoconus-suspect, and post-laser in situ keratomileusis eyes. J Cataract Refract Surg 2009;35:1055-62.
    • (2009) J Cataract Refract Surg , vol.35 , pp. 1055-1062
    • Prospero Ponce, C.M.1    Rocha, K.M.2    Smith, S.D.3    Krueger, R.R.4
  • 20
    • 0942301213 scopus 로고    scopus 로고
    • Intraobserver and interobserver reproducibility in the evaluation of ultrasonic pachymetry measurements of central corneal thickness
    • DOI 10.1136/bjo.2003.023416
    • Miglior S, Albe E, Guareschi M, Mandelli G, Gomarasca S, Orzalesi N. Intraobserver and interobserver reproducibility in the evaluation of ultrasonic pachymetry measurements of central corneal thickness. Br J Ophthalmol 2004;88:174-7. (Pubitemid 38142079)
    • (2004) British Journal of Ophthalmology , vol.88 , Issue.2 , pp. 174-177
    • Miglior, S.1    Albe, E.2    Guareschi, M.3    Mandelli, G.4    Gomarasca, S.5    Orzalesi, N.6
  • 21
    • 35348960981 scopus 로고    scopus 로고
    • Reproducibility and repeatability of central corneal thickness measurement in keratoconus using the rotating Scheimpflug camera and ultrasound pachymetry
    • de Sanctis U, Missolungi A, Mutani B, Richiardi L, Grignolo FM. Reproducibility and repeatability of central corneal thickness measurement in keratoconus using the rotating Scheimpflug camera and ultrasound pachymetry. Am J Ophthalmol 2007;144:712-8.
    • (2007) Am J Ophthalmol , vol.144 , pp. 712-718
    • De Sanctis, U.1    Missolungi, A.2    Mutani, B.3    Richiardi, L.4    Grignolo, F.M.5
  • 22
    • 0033708908 scopus 로고    scopus 로고
    • Central corneal thickness of normal tension glaucoma patients in Japan
    • Wu LL, Suzuki Y, Ideta R, Araie M. Central corneal thickness of normal tension glaucoma patients in Japan. Jpn J Ophthalmol 2000; 44:643-7.
    • (2000) Jpn J Ophthalmol , vol.44 , pp. 643-647
    • Wu, L.L.1    Suzuki, Y.2    Ideta, R.3    Araie, M.4
  • 24
    • 0015975729 scopus 로고
    • A noncontact applanation tonometer. Description and clinical evaluation
    • Forbes M, Pico G Jr, Grolman B. A noncontact applanation tonometer. Description and clinical evaluation. Arch Ophthalmol 1974;91: 134-40.
    • (1974) Arch Ophthalmol , vol.91 , pp. 134-140
    • Forbes, M.1    Pico Jr., G.2    Grolman, B.3
  • 25
    • 0031003564 scopus 로고    scopus 로고
    • A comparison of intraocular pressure measurements with the XPERT noncontact tonometer and Goldmann applanation tonometry
    • Popovich KS, Shields MB. A comparison of intraocular pressure measurements with the XPERT noncontact tonometer and Goldmann applanation tonometry. J Glaucoma 1997;6:44-6. (Pubitemid 27136310)
    • (1997) Journal of Glaucoma , vol.6 , Issue.1 , pp. 44-46
    • Popovich, K.S.1    Shields, M.B.2
  • 26
    • 0018903467 scopus 로고
    • The non-contact tonometer. Its value and limitations
    • DOI 10.1016/0039-6257(80)90042-9
    • Shields MB. The non-contact tonometer. Its value and limitations. Surv Ophthalmol 1980;24:211-9. (Pubitemid 10161236)
    • (1980) Survey of Ophthalmology , vol.24 , Issue.4 , pp. 211-219
    • Shields, M.B.1
  • 27
    • 60349122575 scopus 로고    scopus 로고
    • A comparison of the Goldmann applanation and noncontact (Keeler Pulsair EasyEye) tonometers and the effect of central corneal thickness in indigenous African eyes
    • Babalola OE, Kehinde AV, Iloegbunam AC, Akinbinu T, Moghalu C, Onuoha I. A comparison of the Goldmann applanation and noncontact (Keeler Pulsair EasyEye) tonometers and the effect of central corneal thickness in indigenous African eyes. Ophthalmic Physiol Opt 2009;29:182-8.
    • (2009) Ophthalmic Physiol Opt , vol.29 , pp. 182-188
    • Babalola, O.E.1    Kehinde, A.V.2    Iloegbunam, A.C.3    Akinbinu, T.4    Moghalu, C.5    Onuoha, I.6
  • 29
    • 70349961737 scopus 로고    scopus 로고
    • Goldmann tonometry versus the Tono-Pen XL for intraocular pressure measurement: An evaluation of the potential impact on clinical decision making in glaucoma
    • Carrim ZI, Lavy TE. Goldmann tonometry versus the Tono-Pen XL for intraocular pressure measurement: An evaluation of the potential impact on clinical decision making in glaucoma. Ophthalmic Physiol Opt 2009;29:648-51.
    • (2009) Ophthalmic Physiol Opt , vol.29 , pp. 648-651
    • Carrim, Z.I.1    Lavy, T.E.2
  • 30
    • 67749127538 scopus 로고    scopus 로고
    • Comparisons of intraocular pressure measurements: Goldmann applanation tonometry, noncontact tonometry, Tono-Pen tonometry, and dynamic contour tonometry
    • Hsu SY, Sheu MM, Hsu AH, Wu KY, Yeh JI, Tien JN, Tsai RK. Comparisons of intraocular pressure measurements: Goldmann applanation tonometry, noncontact tonometry, Tono-Pen tonometry, and dynamic contour tonometry. Eye (Lond) 2009;23:1582-8.
    • (2009) Eye (Lond) , vol.23 , pp. 1582-1588
    • Hsu, S.Y.1    Sheu, M.M.2    Hsu, A.H.3    Wu, K.Y.4    Yeh, J.I.5    Tien, J.N.6    Tsai, R.K.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.