-
1
-
-
84908219488
-
Statistical methods for assessing agreement between two clinical methods of clinical measurement
-
Bland, J. M. Altman, D. G. (1986) Statistical methods for assessing agreement between two clinical methods of clinical measurement. Lancet 1, 307 310.
-
(1986)
Lancet
, vol.1
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
2
-
-
0036822851
-
Early manifest glaucoma trial group reduction of intraocular pressure and glaucoma progression: Results from the early manifest glaucoma trial
-
Heijl, A., Leske, M. C., Bengtsson, B., Hyman, L., Bengtsson, B. Hussein, M. (2002) Early manifest glaucoma trial group reduction of intraocular pressure and glaucoma progression: results from the early manifest glaucoma trial. Arch. Ophthalmol. 120, 1268 1279.
-
(2002)
Arch. Ophthalmol.
, vol.120
, pp. 1268-1279
-
-
Heijl, A.1
Leske, M.C.2
Bengtsson, B.3
Hyman, L.4
Bengtsson, B.5
Hussein, M.6
-
3
-
-
11344262810
-
Comparison of the Tono-pen and Goldmann tonometer for measuring intraocular pressure in patients with glaucoma
-
Horowitz, G. S., Byles, J., Lee, J. D'Este, C. (2004) Comparison of the Tono-pen and Goldmann tonometer for measuring intraocular pressure in patients with glaucoma. Clin. Experiment. Ophthalmol. 32, 584 589.
-
(2004)
Clin. Experiment. Ophthalmol.
, vol.32
, pp. 584-589
-
-
Horowitz, G.S.1
Byles, J.2
Lee, J.3
D'Este, C.4
-
4
-
-
0035091093
-
New TonoPen XL: Comparison with the Goldmann tonometer
-
Iester, M., Mermoud, A., Achache, F. Roy, S. (2001) New TonoPen XL: comparison with the Goldmann tonometer. Eye 15, 52 58.
-
(2001)
Eye
, vol.15
, pp. 52-58
-
-
Iester, M.1
Mermoud, A.2
Achache, F.3
Roy, S.4
-
5
-
-
0036269833
-
The Ocular Hypertension Treatment Study: A randomized trial determines that topical ocular hypotensive medications delays or prevents onset of POAG
-
Kass, M. A., Heuer, D. K., Higginbotham, E. J., Johnson, C. A., Keltner, J. L., Miller, J. P., Parrish, R. K II., Wilson, M. R. Gordon, M. O. (2002) The Ocular Hypertension Treatment Study: a randomized trial determines that topical ocular hypotensive medications delays or prevents onset of POAG. Arch. Ophthalmol. 120, 701 703.
-
(2002)
Arch. Ophthalmol.
, vol.120
, pp. 701-703
-
-
Kass, M.A.1
Heuer, D.K.2
Higginbotham, E.J.3
Johnson, C.A.4
Keltner, J.L.5
Miller, J.P.6
Parrish, K.7
Wilson, M.R.8
Gordon, M.O.9
-
6
-
-
0034765810
-
Interim clinical outcomes in the Collaborative Initial Glaucoma Treatment Study comparing initial treatment randomized to medications or surgery
-
CIGTS Study Group
-
Lichter, P. R., Musch, D. C., Gillespie, B. W., Guire, K. E., Janz, N. K., Wren, P. A., Mills, R. P. CIGTS Study Group (2001) Interim clinical outcomes in the Collaborative Initial Glaucoma Treatment Study comparing initial treatment randomized to medications or surgery. Ophthalmology 108 : 1943 1953.
-
(2001)
Ophthalmology
, vol.108
, pp. 1943-1953
-
-
Lichter, P.R.1
Musch, D.C.2
Gillespie, B.W.3
Guire, K.E.4
Janz, N.K.5
Wren, P.A.6
Mills, R.P.7
-
7
-
-
70349959348
-
-
Medtronic Solan. (available at. ; last accessed 15 July 2008)
-
Medtronic Solan (2008) Tono-Pen XL Applanation Tonometer-Product Information. (available at: http://www.medtronicophthalmics.com/pdfs/ TonoPenXLProductSheet.pdf ; last accessed 15 July 2008)
-
(2008)
Tono-Pen XL Applanation Tonometer-Product Information
-
-
-
8
-
-
34248162503
-
Comparisons between Pascal dynamic countour tonometry, TonoPen and Goldmann applanation tonometry in patients with glaucoma
-
Salvetat, M. L., Zeppieri, M., Tosoni, C. Brusini, P. (2007) Comparisons between Pascal dynamic countour tonometry, TonoPen and Goldmann applanation tonometry in patients with glaucoma. Acta Ophthalmol. Scand. 85, 272 279.
-
(2007)
Acta Ophthalmol. Scand.
, vol.85
, pp. 272-279
-
-
Salvetat, M.L.1
Zeppieri, M.2
Tosoni, C.3
Brusini, P.4
-
9
-
-
21344456718
-
A comparison of four methods of tonometry: Method agreement and interobserver variability
-
Tonnu, P-A., Ho, T., Sharma, K., White, E., Bunce, C. Garway-Heath, D. (2005) A comparison of four methods of tonometry: method agreement and interobserver variability. Br. J. Ophthalmol. 89, 847 850.
-
(2005)
Br. J. Ophthalmol.
, vol.89
, pp. 847-850
-
-
Tonnu, P.-A.1
Ho, T.2
Sharma, K.3
White, E.4
Bunce, C.5
Garway-Heath, D.6
-
10
-
-
28244471011
-
Three portable tonometers, the TGDc-01, the iCARE and the Tonopen XL, compared with each other and with Goldmann applanation tonometry
-
Van der Jagt, L. H. Jansonius, N. M. (2005) Three portable tonometers, the TGDc-01, the iCARE and the Tonopen XL, compared with each other and with Goldmann applanation tonometry. Ophthalmic Physiol. Opt. 25, 429 435.
-
(2005)
Ophthalmic Physiol. Opt.
, vol.25
, pp. 429-435
-
-
Van Der Jagt, L.H.1
Jansonius, N.M.2
|