메뉴 건너뛰기




Volumn 3, Issue 4, 2011, Pages 956-968

Interfacial antiwear and physicochemical properties of alkylborate- dithiophosphates

Author keywords

borophosphates; dialkylborate alkyl dialkyldithiophosphates; lubricant additives; SEM EDS; solid state MAS NMR; thermal analyses; Zn BuDTP

Indexed keywords

BOROPHOSPHATES; DIALKYLBORATE-ALKYL-DIALKYLDITHIOPHOSPHATES; LUBRICANT ADDITIVES; SEM/EDS; THERMAL ANALYSES; ZN-BUDTP;

EID: 79960113357     PISSN: 19448244     EISSN: 19448252     Source Type: Journal    
DOI: 10.1021/am101203t     Document Type: Article
Times cited : (47)

References (64)
  • 12
    • 0000707635 scopus 로고    scopus 로고
    • Hsu, S. M. Langmuir 1996, 12, 4482-4485
    • (1996) Langmuir , vol.12 , pp. 4482-4485
    • Hsu, S.M.1
  • 21
  • 22
    • 0017631307 scopus 로고
    • Baldwin, B. A. Wear 1977, 45, 345-353
    • (1977) Wear , vol.45 , pp. 345-353
    • Baldwin, B.A.1
  • 41
    • 81455160878 scopus 로고    scopus 로고
    • The elemental analysis for C and H was performed according to Dumas method using Flash EA 1112 from Thermo Finnigan elemental analyser. About 1 mg of the sample was weighed in tin capsule, sealed and placed in an auto sampler, from which it was dropped into a combustion chamber. As the sample entered the combustion chamber oxygen was injected into the carrier gas (He), which flowed through the combustion tube. The temperature was raised to 1800 °C, which ensured the complete combustion of the sample. Detection was made with a Hot Wire Detector (HWD). The quantification was made using certified external standards and the method of least-squares with the correlation coefficient >0.999.
    • http://www.mikrokemi.se. The elemental analysis for C and H was performed according to Dumas method using Flash EA 1112 from Thermo Finnigan elemental analyser. About 1 mg of the sample was weighed in tin capsule, sealed and placed in an auto sampler, from which it was dropped into a combustion chamber. As the sample entered the combustion chamber oxygen was injected into the carrier gas (He), which flowed through the combustion tube. The temperature was raised to 1800 °C, which ensured the complete combustion of the sample. Detection was made with a Hot Wire Detector (HWD). The quantification was made using certified external standards and the method of least-squares with the correlation coefficient >0.999.
  • 42
    • 81455161385 scopus 로고    scopus 로고
    • 3 (micro wave assisted digestion in closed Teflon vessels). After cooling to room temperature the digest was diluted with MQ water and concentrations of B were determined by ICP-SFMS using a combination of internal standardization and external calibration. Elemental analysis was carried out in the medium resolution range, AZm / m = 4500 (Finnigan MAT, Bremen, Germany). Each measurement was done in triplicate.
    • 3 (micro wave assisted digestion in closed Teflon vessels). After cooling to room temperature the digest was diluted with MQ water and concentrations of B were determined by ICP-SFMS using a combination of internal standardization and external calibration. Elemental analysis was carried out in the medium resolution range, AZm / m = 4500 (Finnigan MAT, Bremen, Germany). Each measurement was done in triplicate.
  • 63
    • 60149107967 scopus 로고    scopus 로고
    • Tse, J. S. Nature 2009, 457, 800-801
    • (2009) Nature , vol.457 , pp. 800-801
    • Tse, J.S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.