메뉴 건너뛰기




Volumn 157, Issue 1, 2011, Pages 265-274

An LDA based sensor selection approach used in breath analysis system

Author keywords

Breath analysis; Disease recognition; Linear discriminant analysis; Sensor selection

Indexed keywords

BREATH ANALYSIS; GENERAL APPLICATIONS; LINEAR COMBINATIONS; LINEAR DISCRIMINANT ANALYSIS; OPTIMAL CONFIGURATIONS; PROCESSING TIME; RECOGNITION ACCURACY; SENSOR SELECTION; SEQUENTIAL FORWARD SELECTION; WEIGHT VECTOR;

EID: 79959677422     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2011.03.061     Document Type: Article
Times cited : (15)

References (38)
  • 3
    • 4143053648 scopus 로고    scopus 로고
    • Diagnostic potential of breath analysis - Focus on volatile organic compounds
    • DOI 10.1016/j.cccn.2004.04.023, PII S0009898104002256
    • W. Miekisch, J. Schubert, and G. Noeldge-Schomburg Diagnostic potential of breath analysis-focus on volatile organic compounds Clinica Chimica Acta 347 2004 25 39 (Pubitemid 39099603)
    • (2004) Clinica Chimica Acta , vol.347 , Issue.1-2 , pp. 25-39
    • Miekisch, W.1    Schubert, J.K.2    Noeldge-Schomburg, G.F.E.3
  • 6
    • 12344256993 scopus 로고    scopus 로고
    • Breath analysis: Trends in techniques and clinical applications
    • DOI 10.1016/j.microc.2004.10.008, PII S0026265X04001973, XI Italian Hungarian Symposium on Spectrochemistry
    • F. Di Francesco, R. Fuoco, M. Trivella, and A. Ceccarini Breath analysis: trends in techniques and clinical applications Microchemical Journal 79 2005 405 410 (Pubitemid 40126348)
    • (2005) Microchemical Journal , vol.79 , Issue.1-2 , pp. 405-410
    • Di Francesco, F.1    Fuoco, R.2    Trivella, M.G.3    Ceccarini, A.4
  • 7
    • 84883604225 scopus 로고    scopus 로고
    • Exhaled breath analysis: The new frontier in medical testing
    • R. Dweik, and A. Amann Exhaled breath analysis: the new frontier in medical testing Journal of Breath Research 2 2008 030301
    • (2008) Journal of Breath Research , vol.2 , pp. 030301
    • Dweik, R.1    Amann, A.2
  • 13
    • 19744377703 scopus 로고    scopus 로고
    • Analysis of diabetic patient's breath with conducting polymer sensor array
    • DOI 10.1016/j.snb.2005.01.040, PII S0925400505001309
    • J. Yu, H. Byun, M. So, and J. Huh Analysis of diabetic patient's breath with conducting polymer sensor array Sensors and Actuators B: Chemical 108 2005 305 308 (Pubitemid 40743705)
    • (2005) Sensors and Actuators, B: Chemical , vol.108 , Issue.SPEC. ISS. , pp. 305-308
    • Yu, J.-B.1    Byun, H.-G.2    So, M.-S.3    Huh, J.-S.4
  • 14
    • 77953915540 scopus 로고    scopus 로고
    • Real time electronic nose based pathogen detection for respiratory intensive care patients
    • C. Shih, Y. Lin, K. Lee, P. Chien, and P. Drake Real time electronic nose based pathogen detection for respiratory intensive care patients Sensors and Actuators B: Chemical 2010 153 157
    • (2010) Sensors and Actuators B: Chemical , pp. 153-157
    • Shih, C.1    Lin, Y.2    Lee, K.3    Chien, P.4    Drake, P.5
  • 19
    • 0036227810 scopus 로고    scopus 로고
    • Breath biomarkers for detection of human liver diseases: Preliminary study
    • DOI 10.1080/13547500110118184
    • S. Sehnert, L. Jiang, J. Burdick, and T. Risby Breath biomarkers for detection of human liver diseases: preliminary study Biomarkers 7 2002 174 187 (Pubitemid 34413866)
    • (2002) Biomarkers , vol.7 , Issue.2 , pp. 174-187
    • Sehnert, S.S.1    Jiang, L.2    Burdick, J.F.3    Risby, T.H.4
  • 20
    • 0030744990 scopus 로고    scopus 로고
    • Quantitative analysis of ammonia on the breath of patients in end-stage renal failure
    • S. Davies, P. Spanel, and D. Smith Quantitative analysis of ammonia on the breath of patients in end-stage renal failure Kidney International 52 1997 223 228 (Pubitemid 27321835)
    • (1997) Kidney International , vol.52 , Issue.1 , pp. 223-228
    • Davies, S.1    Spanel, P.2    Smith, D.3
  • 23
    • 0031752135 scopus 로고    scopus 로고
    • Increased levels of exhaled carbon monoxide in bronchiectasis: A new marker of oxidative stress
    • I. Horvath, S. Loukides, T. Wodehouse, S. Kharitonov, P. Cole, and P. Barnes Increased levels of exhaled carbon monoxide in bronchiectasis: a new marker of oxidative stress British Medical Journal 53 1998 867 870 (Pubitemid 28459544)
    • (1998) Thorax , vol.53 , Issue.10 , pp. 867-870
    • Horvath, I.1    Loukides, S.2    Wodehouse, T.3    Kharitonov, S.A.4    Cole, P.J.5    Barnes, P.J.6
  • 27
    • 16644388588 scopus 로고    scopus 로고
    • Enhancing electronic nose performance by sensor selection using a new integer-based genetic algorithm approach
    • DOI 10.1016/j.snb.2004.05.043, PII S0925400504004071
    • J. Gardner, P. Boilot, and E. Hines Enhancing electronic nose performance by sensor selection using a new integer-based genetic algorithm approach Sensors and Actuators B: Chemical 106 2005 114 121 (Pubitemid 40480232)
    • (2005) Sensors and Actuators, B: Chemical , vol.106 , Issue.1 SPEC. ISS. , pp. 114-121
    • Gardner, J.W.1    Boilot, P.2    Hines, E.L.3
  • 36
    • 0242624674 scopus 로고    scopus 로고
    • A novel method for Fisher discriminant analysis
    • DOI 10.1016/S0031-3203(03)00232-2
    • Y. Xu, J. Yang, and Z. Jin A novel method for Fisher discriminant analysis Pattern Recognition 37 2004 381 384 (Pubitemid 37425419)
    • (2004) Pattern Recognition , vol.37 , Issue.2 , pp. 381-384
    • Xu, Y.1    Yang, J.-Y.2    Jin, Z.3
  • 38
    • 2142650125 scopus 로고    scopus 로고
    • A reformative kernel Fisher discriminant analysis
    • DOI 10.1016/j.patcog.2003.10.006, PII S0031320303003984
    • Y. Xu, J. Yang, and J. Yang A reformative kernel Fisher discriminant analysis Pattern Recognition 37 2004 1299 1302 (Pubitemid 38549827)
    • (2004) Pattern Recognition , vol.37 , Issue.6 , pp. 1299-1302
    • Xu, Y.1    Yang, J.-y.2    Yang, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.