Volumn 26, Issue 10, 2011, Pages 1234-1242

Alleviating fatigue and failure of NiTi endodontic files by a coating containing inorganic fullerene-like WS2 nanoparticles

Author keywords

Coating; Fatigue; Tribology

Indexed keywords

CARDIOVASCULAR STENTS; COBALT COATING; DENTAL APPLICATIONS; DYNAMIC X-RAY DIFFRACTION; ENDODONTIC FILES; MEDICAL DEVICES; NICKEL TITANIUM; ROOT CANAL TREATMENT; SHAPE-MEMORY; STRAIN RECOVERY; SUPERELASTICITY;

EID: 79959424693     PISSN: 08842914     EISSN: None     Source Type: Journal    
DOI: 10.1557/jmr.2011.52     Document Type: Article
Times cited : (30)

References (40)
  • 1
    • 41549097188 scopus 로고    scopus 로고
    • Critical overview of Nitinol surfaces and their modifications for medical applications
    • S. Shabalovskaya, J. Anderegg, and J. Van Humbeeck: Critical overview of Nitinol surfaces and their modifications for medical applications. Acta Biomater. 4, 447 (2008).
    • (2008) Acta Biomater , vol.4 , pp. 447
    • Shabalovskaya, S.1    Anderegg, J.2    Van Humbeeck, J.3
  • 2
    • 0038716209 scopus 로고    scopus 로고
    • Medical applications of shape memory alloys
    • L.G. Machado and M.A. Savi: Medical applications of shape memory alloys. Braz. J. Med. Biol. Res. 36, 683 (2003).
    • (2003) Braz. J. Med. Biol. Res. , vol.36 , pp. 683
    • Machado, L.G.1    Savi, M.A.2
  • 3
    • 0039171080 scopus 로고    scopus 로고
    • An overview of Nitinol medical applications
    • T. Duerig, A. Pelton, and D. Stockel: An overview of Nitinol medical applications. Mater. Sci Eng., A 273, 149 (1999).
    • (1999) Mater. Sci Eng., A , vol.273 , pp. 149
    • Duerig, T.1    Pelton, A.2    Stockel, D.3
  • 4
    • 0034231421 scopus 로고    scopus 로고
    • An overview of nickel-titanium alloys used in dentistry
    • S.A. Thompson: An overview of nickel-titanium alloys used in dentistry. Int. Endod. J. 33, 297 (2000).
    • (2000) Int. Endod. J. , vol.33 , pp. 297
    • Thompson, S.A.1
  • 5
    • 0024052338 scopus 로고
    • An initial investigation of the bending and torsional properties of Nitinol root-canal files
    • H. Walia, W.A. Brantley, and H. Gerstein: An initial investigation of the bending and torsional properties of Nitinol root-canal files. J. Endod. 14, 346 (1988).
    • (1988) J. Endod. , vol.14 , pp. 346
    • Walia, H.1    Brantley, W.A.2    Gerstein, H.3
  • 6
    • 4143097917 scopus 로고    scopus 로고
    • Current challenges and concepts in the preparation of root canal systems: A review
    • O.A. Peters: Current challenges and concepts in the preparation of root canal systems: A review. J. Endod. 30, 559 (2004).
    • (2004) J. Endod. , vol.30 , pp. 559
    • Peters, O.A.1
  • 7
    • 13844313866 scopus 로고    scopus 로고
    • Physical metallurgy of Ti-Ni-based shape memory alloys
    • K. Otsuka and X. Ren: Physical metallurgy of Ti-Ni-based shape memory alloys. Prog. Mater. Sci. 50, 511 (2005).
    • (2005) Prog. Mater. Sci. , vol.50 , pp. 511
    • Otsuka, K.1    Ren, X.2
  • 8
    • 0030622331 scopus 로고    scopus 로고
    • Shaping ability of ProFile.04 taper series 29 rotary nickel-titanium instruments in simulated root canals. 1
    • S.A. Thompson and P.M.H. Dummer: Shaping ability of ProFile.04 Taper Series 29 rotary nickel-titanium instruments in simulated root canals. 1. Int. Endod. J. 30, 1 (1997).
    • (1997) Int. Endod. J. , vol.30 , pp. 1
    • Thompson, S.A.1    Dummer, P.M.H.2
  • 9
    • 33750468996 scopus 로고    scopus 로고
    • In vitro fatigue-crack growth and fracture toughness behavior of thin-walled superelastic Nitinol tube for endovascular stents: A basis for defining the effect of crack-like defects
    • S.W. Robertson and R.O. Ritchie: In vitro fatigue-crack growth and fracture toughness behavior of thin-walled superelastic Nitinol tube for endovascular stents: A basis for defining the effect of crack-like defects. Biomaterials 28, 700 (2007).
    • (2007) Biomaterials , vol.28 , pp. 700
    • Robertson, S.W.1    Ritchie, R.O.2
  • 11
    • 0027682519 scopus 로고
    • Mechanism of the A(S) temperature increase by pre-deformation in thermoelastic alloys
    • M. Piao, K. Otsuka, S. Miyazaki, and H. Horikawa: Mechanism of the A(S) temperature increase by pre-deformation in thermoelastic alloys. Mater. Trans., JIM 34, 919 (1993).
    • (1993) Mater. Trans., JIM , vol.34 , pp. 919
    • Piao, M.1    Otsuka, K.2    Miyazaki, S.3    Horikawa, H.4
  • 12
    • 0037048566 scopus 로고    scopus 로고
    • 3-precipitation during aging of NiTi shape memory alloys and its influence on martensitic phase transformations
    • 3- precipitation during aging of NiTi shape memory alloys and its influence on martensitic phase transformations. Acta Mater. 50, 4255 (2002).
    • (2002) Acta Mater. , vol.50 , pp. 4255
    • Khalil-Allafi, J.1    Dlouhy, A.2    Eggeler, G.3
  • 13
    • 0035221977 scopus 로고    scopus 로고
    • Influence of rotational speed, torque and operator's proficiency on ProFile failures
    • G.M. Yared, F.E.B. Dagher, and P. Machtou: Influence of rotational speed, torque and operator's proficiency on ProFile failures. Int. Endod. J. 34, 47 (2001).
    • (2001) Int. Endod. J. , vol.34 , pp. 47
    • Yared, G.M.1    Dagher, F.E.B.2    Machtou, P.3
  • 14
    • 33750008122 scopus 로고    scopus 로고
    • Rotary NiTi instrument fracture and its consequences
    • P. Parashos and H.H. Messer: Rotary NiTi instrument fracture and its consequences. J. Endod. 32, 1031 (2006).
    • (2006) J. Endod. , vol.32 , pp. 1031
    • Parashos, P.1    Messer, H.H.2
  • 15
    • 0034157104 scopus 로고    scopus 로고
    • Torque during canal instrumentation using rotary nickel-titanium files
    • B. Sattapan, J.E.A. Palamara, and H.H. Messer: Torque during canal instrumentation using rotary nickel-titanium files. J. Endod. 26, 156 (2000).
    • (2000) J. Endod. , vol.26 , pp. 156
    • Sattapan, B.1    Palamara, J.E.A.2    Messer, H.H.3
  • 16
    • 0035432084 scopus 로고    scopus 로고
    • Influence of structure on nickel-titanium endodontic instruments failure
    • G. Kuhn, B. Tavernier, and L. Jordan: Influence of structure on nickel-titanium endodontic instruments failure. J. Endod. 27, 516 (2001).
    • (2001) J. Endod. , vol.27 , pp. 516
    • Kuhn, G.1    Tavernier, B.2    Jordan, L.3
  • 17
    • 69849087549 scopus 로고    scopus 로고
    • Effect of mechanical cycling on the stress-strain response of a martensitic Nitinol shape memory alloy
    • N. Nayan, V. Buravalla, and U. Ramamurty: Effect of mechanical cycling on the stress-strain response of a martensitic Nitinol shape memory alloy. Mater. Sci. Eng., A 525, 60 (2009).
    • (2009) Mater. Sci. Eng., A , vol.525 , pp. 60
    • Nayan, N.1    Buravalla, V.2    Ramamurty, U.3
  • 18
    • 0038146983 scopus 로고    scopus 로고
    • ProTaper rotary root canal preparation: Assessment of torque and force in relation to canal anatomy
    • O.A. Peters, C.I. Peters, K. Schonenberger, and F. Barbakow: ProTaper rotary root canal preparation: Assessment of torque and force in relation to canal anatomy. Int. Endod. J. 36, 93 (2003).
    • (2003) Int. Endod. J. , vol.36 , pp. 93
    • Peters, O.A.1    Peters, C.I.2    Schonenberger, K.3    Barbakow, F.4
  • 20
    • 34548524624 scopus 로고    scopus 로고
    • Fracture resistance of electropolished rotary nickel-titanium endodontic instruments
    • M.E. Anderson, J.W.H. Price, and P. Parashos: Fracture resistance of electropolished rotary nickel-titanium endodontic instruments. J. Endod. 33, 1212 (2007).
    • (2007) J. Endod. , vol.33 , pp. 1212
    • Anderson, M.E.1    Price, J.W.H.2    Parashos, P.3
  • 21
    • 0036394462 scopus 로고    scopus 로고
    • Structural and mechanical characterisation of boron and nitrogen implanted NiTi shape memory alloy
    • H. Pelletier, D. Muller, P. Mille, and J.J. Grob: Structural and mechanical characterisation of boron and nitrogen implanted NiTi shape memory alloy. Surf. Coat. Tech. 158, 309 (2002).
    • (2002) Surf. Coat. Tech. , vol.158 , pp. 309
    • Pelletier, H.1    Muller, D.2    Mille, P.3    Grob, J.J.4
  • 23
    • 19644393686 scopus 로고    scopus 로고
    • 2) inorganic nanotubes and fullerene-like nanoparticles for solid lubrication and for structural nanocomposites
    • 2) inorganic nanotubes and fullerene-like nanoparticles for solid lubrication and for structural nanocomposites. J. Mater. Chem. 15, 1782 (2005).
    • (2005) J. Mater. Chem. , vol.15 , pp. 1782
    • Rapoport, L.1    Fleischer, N.2    Tenne, R.3
  • 25
    • 73349083715 scopus 로고    scopus 로고
    • Inorganic fullerene-like tungsten disulfide nanocoating for friction reduction of nickel-titanium alloys
    • G.R. Samorodnitzky-Naveh, M. Redlich, L. Rapoport, Y. Feldman, and R. Tenne: Inorganic fullerene-like tungsten disulfide nanocoating for friction reduction of nickel-titanium alloys. Nanomedicine 4, 943 (2009).
    • (2009) Nanomedicine , vol.4 , pp. 943
    • Samorodnitzky-Naveh, G.R.1    Redlich, M.2    Rapoport, L.3    Feldman, Y.4    Tenne, R.5
  • 29
    • 79959465123 scopus 로고    scopus 로고
    • 2). Acute oral toxicity, acute toxic class method in the rat
    • Harlan Biotech, Israel
    • 2). Acute oral toxicity, acute toxic class method in the rat. Final report. Batch No. HP6, Harlan Biotech, Israel (2005).
    • (2005) Final report. Batch No. HP6
    • Tsabari, H.1
  • 30
    • 59449097055 scopus 로고    scopus 로고
    • Project No. 052052, BSL Disservice, Germany
    • 2 nanospheres. Project No. 052052, BSL Disservice, Germany (2005).
    • (2005) 2 nanospheres
    • Haist, I.1
  • 31
    • 79951865498 scopus 로고    scopus 로고
    • Biocompatible inorganic fullerene-like molybdenum disulfide nanoparticles produced by pulsed laser ablation in water
    • H. Wu, R. Yang, B. Song, Q. Han, J. Li, Y. Zhang, Y. Fang, R. Tenne, and C. Wang: Biocompatible inorganic fullerene-like molybdenum disulfide nanoparticles produced by pulsed laser ablation in water. ACS Nano. 5, 1276 (2011).
    • (2011) ACS Nano. , vol.5 , pp. 1276
    • Wu, H.1    Yang, R.2    Song, B.3    Han, Q.4    Li, J.5    Zhang, Y.6    Fang, Y.7    Tenne, R.8    Wang, C.9
  • 32
    • 0028466723 scopus 로고
    • Electrodeposition of cobalt-chromium alloy from trivalent chromium solutions
    • H. Dasarathy, C. Riley, and H.D. Coble: Electrodeposition of cobalt-chromium alloy from trivalent chromium solutions. J. Electrochem. Soc. 141, 1773 (1994).
    • (1994) J. Electrochem. Soc. , vol.141 , pp. 1773
    • Dasarathy, H.1    Riley, C.2    Coble, H.D.3
  • 33
    • 42749096667 scopus 로고    scopus 로고
    • On the mechanism of biocompatibility
    • D.F. Williams: On the mechanism of biocompatibility. Biomaterials 29, 2941 (2008).
    • (2008) Biomaterials , vol.29 , pp. 2941
    • Williams, D.F.1
  • 34
    • 27644531935 scopus 로고    scopus 로고
    • Physical and mechanical characterization and the influence of cyclic loading on the behaviour of nickel-titanium wires employed in the manufacture of rotary endodontic instruments
    • M.G.A. Bahia, R.C. Martins, B.M. Gonzalez, and V.T.L. Buono: Physical and mechanical characterization and the influence of cyclic loading on the behaviour of nickel-titanium wires employed in the manufacture of rotary endodontic instruments. Int. Endod. J. 38, 795 (2005).
    • (2005) Int. Endod. J. , vol.38 , pp. 795
    • Bahia, M.G.A.1    Martins, R.C.2    Gonzalez, B.M.3    Buono, V.T.L.4
  • 35
    • 0040315106 scopus 로고    scopus 로고
    • The concern of elasticity in stress-induced martensitic transformation in NiTi
    • Y.O. Liu and H. Yang: The concern of elasticity in stress-induced martensitic transformation in NiTi. Mater. Sci. Eng., A 260, 240 (1999).
    • (1999) Mater. Sci. Eng., A , vol.260 , pp. 240
    • Liu, Y.O.1    Yang, H.2
  • 36
    • 33750458351 scopus 로고    scopus 로고
    • Deformation-induced martensite stabilisation in [100] single-crystalline Ni-Ti
    • Y.N. Liu, G. Tan, and S. Miyazaki: Deformation-induced martensite stabilisation in [100] single-crystalline Ni-Ti. Mater. Sci. Eng., A 438, 612 (2006).
    • (2006) Mater. Sci. Eng., A , vol.438 , pp. 612
    • Liu, Y.N.1    Tan, G.2    Miyazaki, S.3
  • 37
    • 0033897753 scopus 로고    scopus 로고
    • Effect of deformation by stress-induced martensitic transformation on the transformation behaviour of NiTi
    • Y.N. Liu and G.S. Tan: Effect of deformation by stress-induced martensitic transformation on the transformation behaviour of NiTi. Intermetallics 8, 67 (2000).
    • (2000) Intermetallics , vol.8 , pp. 67
    • Liu, Y.N.1    Tan, G.S.2
  • 38
    • 33644645409 scopus 로고    scopus 로고
    • Failure mechanism of ProTaper Ni-Ti rotary instruments during clinical use: Fractographic analysis
    • A.P. Spanaki-Voreadi, N.P. Kerezoudis, and S. Zinelis: Failure mechanism of ProTaper Ni-Ti rotary instruments during clinical use: Fractographic analysis. Int. Endod. J. 39, 171 (2006).
    • (2006) Int. Endod. J. , vol.39 , pp. 171
    • Spanaki-Voreadi, A.P.1    Kerezoudis, N.P.2    Zinelis, S.3
  • 39
    • 12344257590 scopus 로고    scopus 로고
    • SEM observations of nickel-titanium rotary endodontic instruments that fractured during clinical use
    • S.B. Alapati, W.A. Brantley, T.A. Svec, J.M. Powers, J.M. Nusstein, and G.S. Daehn: SEM observations of nickel-titanium rotary endodontic instruments that fractured during clinical use. J. Endod. 31, 40 (2005).
    • (2005) J. Endod. , vol.31 , pp. 40
    • Alapati, S.B.1    Brantley, W.A.2    Svec, T.A.3    Powers, J.M.4    Nusstein, J.M.5    Daehn, G.S.6
  • 40
    • 2442503674 scopus 로고    scopus 로고
    • Stress-induced transformation behavior of a polycrystalline NiTi shape memory alloy: Micro and macromechanical investigations via in situ optical microscopy
    • L.C. Brinson, I. Schmidt, and R. Lammering: Stress-induced transformation behavior of a polycrystalline NiTi shape memory alloy: Micro and macromechanical investigations via in situ optical microscopy. J. Mech. Phys. Solids. 52, 1549 (2004).
    • (2004) J. Mech. Phys. Solids. , vol.52 , pp. 1549
    • Brinson, L.C.1    Schmidt, I.2    Lammering, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.