메뉴 건너뛰기




Volumn 16, Issue 3, 2011, Pages 242-247

Brain magnetic resonance image segmentation using novel improvement for expectation maximizing

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ARTICLE; BRAIN REGION; CLUSTER ANALYSIS; COMPUTER PROGRAM; CONTROLLED STUDY; FUZZY SYSTEM; IMAGE ANALYSIS; IMAGE PROCESSING; IMAGE QUALITY; INTERMETHOD COMPARISON; INTERNET; LEARNING ALGORITHM; MATHEMATICAL COMPUTING; MATHEMATICAL MODEL; MAXIMUM LIKELIHOOD METHOD; NEUROIMAGING; NUCLEAR MAGNETIC RESONANCE IMAGING; PROBABILITY;

EID: 79959339854     PISSN: 13196138     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (12)

References (26)
  • 1
    • 79952365254 scopus 로고    scopus 로고
    • Edge-preserving clustering algorithms and their application for MRI image segmentation
    • Ao SI, Castillo O, Douglas C, Feng DD, Lee JA, editors, 2010 March 17-19; Hong Kong. Hong Kong: IAENG
    • Balafar MA, Ramli AR, Mashohor S. Edge-preserving Clustering Algorithms and Their Application for MRI Image Segmentation. In: Ao SI, Castillo O, Douglas C, Feng DD, Lee JA, editors. Proceedings of the International MultiConference of Engineers and Computer Scientists IMECS 2010; 2010 March 17-19; Hong Kong. Hong Kong: IAENG; 2010. p. 17- 19.
    • (2010) Proceedings of the International MultiConference of Engineers and Computer Scientists IMECS 2010 , pp. 17-19
    • Balafar, M.A.1    Ramli, A.R.2    Mashohor, S.3
  • 5
    • 34548709815 scopus 로고    scopus 로고
    • X-ray image segmentation using active contour model with global constraints
    • 2007 June 4; Honolulu. Honolulu (HI): IEEE
    • Jiang Y, Meng J, Babyn P. X-ray image segmentation using active contour model with global constraints. Proceedings of CIISP 2007; 2007 June 4; Honolulu. Honolulu (HI): IEEE; 2007. p. 240-45.
    • (2007) Proceedings of CIISP 2007 , pp. 240-245
    • Jiang, Y.1    Meng, J.2    Babyn, P.3
  • 8
    • 77952621669 scopus 로고    scopus 로고
    • Compare different spatial based Fuzzy C-Mean (FCM) extensions for MRI Image Segmentation
    • 2010 April 19. Singapore. Singapore: IEEE
    • Balafar MA, Ramli AR, Mashohor S. Compare different spatial based Fuzzy C-Mean (FCM) extensions for MRI Image Segmentation. Proceedings of the ICCAE 2010; 2010 April 19. Singapore. Singapore: IEEE; 2010. p. 609-611.
    • (2010) Proceedings of the ICCAE 2010 , pp. 609-611
    • Balafar, M.A.1    Ramli, A.R.2    Mashohor, S.3
  • 11
  • 12
    • 77954335322 scopus 로고    scopus 로고
    • MR image segmentation using wavelet analysis techniques [CDROM]
    • Su HR, Liou M, Cheng PE, Aston JAD, Chuang CH. MR image segmentation using wavelet analysis techniques [CDROM]. Neuroimage 2005; 26 (Suppl 1).
    • (2005) Neuroimage , vol.26 , Issue.SUPPL. 1
    • Su, H.R.1    Liou, M.2    Cheng, P.E.3    Aston, J.A.D.4    Chuang, C.H.5
  • 13
    • 44149104064 scopus 로고    scopus 로고
    • Generalized fuzzy clustering for segmentation of multi-spectral magnetic resonance images
    • He R, Datta S, Sajja BR, Narayana PA. Generalized fuzzy clustering for segmentation of multi-spectral magnetic resonance images. Comput Med Imaging Graph 2008; 32: 353-366.
    • (2008) Comput Med Imaging Graph , vol.32 , pp. 353-366
    • He, R.1    Datta, S.2    Sajja, B.R.3    Narayana, P.A.4
  • 19
    • 0034745001 scopus 로고    scopus 로고
    • Segmentation of brain MR images through a hidden Markov random field model and the expectation-maximization algorithm
    • Zhang Y, Brady M, Smith S. Segmentation of brain MR images through a hidden Markov random field model and the expectation-maximization algorithm. IEEE Trans Med Imaging 2001; 20: 45-57.
    • (2001) IEEE Trans Med Imaging , vol.20 , pp. 45-57
    • Zhang, Y.1    Brady, M.2    Smith, S.3
  • 20
    • 70350134183 scopus 로고    scopus 로고
    • A vectorial image soft segmentation method based on neighborhood weighted Gaussian mixture model
    • Tanga H, Dillensegerb JL, Baoa XD, Luoa LM. A vectorial image soft segmentation method based on neighborhood weighted Gaussian mixture model. Comput Med Imaging Graph 2009; 33: 644-650.
    • (2009) Comput Med Imaging Graph , vol.33 , pp. 644-650
    • Tanga, H.1    Dillensegerb, J.L.2    Baoa, X.D.3    Luoa, L.M.4
  • 21
    • 59449092337 scopus 로고    scopus 로고
    • A nonlocal maximum likelihood estimation method for Rician noise reduction in MR images
    • He L, Greenshields IR. A nonlocal maximum likelihood estimation method for Rician noise reduction in MR images. IEEE Trans Med Imaging 2009; 28: 165-172.
    • (2009) IEEE Trans Med Imaging , vol.28 , pp. 165-172
    • He, L.1    Greenshields, I.R.2
  • 23
    • 79959357090 scopus 로고    scopus 로고
    • MGH CMA, National Institute of Science: Harvard Medical School, [updated 2009 January 15; Cited 2010 October 1]: Available from URL
    • MGH CMA. IBSR: The Internet Brain Segmentation Repository [Internet]. National Institute of Science: Harvard Medical School; 1997 [updated 2009 January 15; Cited 2010 October 1]: Available from URL: http://www.cma.mgh.harvard.edu/ibsr.
    • (1997) IBSR: The Internet Brain Segmentation Repository [Internet]
  • 24
    • 60149092888 scopus 로고    scopus 로고
    • Bayesian mixture models of variable dimension for image segmentation
    • Ferreira da Silva AR. Bayesian mixture models of variable dimension for image segmentation. Computer Methods Programs Biomed 2009; 94: 1-14.
    • (2009) Computer Methods Programs Biomed , vol.94 , pp. 1-14
    • da Silva, A.R.F.1
  • 25
    • 33750512945 scopus 로고    scopus 로고
    • Fast and robust fuzzy c-means clustering algorithms incorporating local information for image segmentation
    • Cai W, Chen S, Zhang D. Fast and robust fuzzy c-means clustering algorithms incorporating local information for image segmentation. Pattern Recognition 2007; 40: 825-838.
    • (2007) Pattern Recognition , vol.40 , pp. 825-838
    • Cai, W.1    Chen, S.2    Zhang, D.3
  • 26
    • 33847774807 scopus 로고    scopus 로고
    • A review of methods for correction of intensity in homogeneity in MRI
    • Vovk U, Pernus F, Likar B. A review of methods for correction of intensity in homogeneity in MRI. IEEE Tran Med Imaging 2007; 26: 405-421.
    • (2007) IEEE Tran Med Imaging , vol.26 , pp. 405-421
    • Vovk, U.1    Pernus, F.2    Likar, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.