-
1
-
-
0031436849
-
Bioimpedance spectroscopy technique: Intra-, extracellular, and total body water
-
DOI 10.1097/00005768-199712000-00017
-
Armstrong L E, Kenefick R W, Castellani J W, Riebe D, Kavouras S A, Kuznicki J T and Maresh C M 1997 Bioimpedance spectroscopy technique: intra-, extracellular, and total body water Med. Sci. Sports Exerc. 29 1657-63 (Pubitemid 28012145)
-
(1997)
Medicine and Science in Sports and Exercise
, vol.29
, Issue.12
, pp. 1657-1663
-
-
Armstrong, L.E.1
Kenefick, R.W.2
Castellani, J.W.3
Riebe, D.4
Kavouras, S.A.5
Kuznicki, J.T.6
Maresh, C.M.7
-
2
-
-
0027964816
-
Assessment of refill and hypovolaemia by continuous surveillance of blood volume and extracellular fluid volume
-
Bogaard H J, de Vries J P and de Vries P M 1994 Assessment of refill and hypovolaemia by continuous surveillance of blood volume and extracellular fluid volume Nephrol. Dial. Transplant. 9 1283-7 (Pubitemid 24283655)
-
(1994)
Nephrology Dialysis Transplantation
, vol.9
, Issue.9
, pp. 1283-1287
-
-
Bogaard, H.J.1
De Vries, J.P.P.M.2
De Vries, P.M.J.M.3
-
3
-
-
78650663879
-
The effect of vascular access modality on changes in fluid content in the arms as determined by multifrequency bioimpedance
-
Booth J, Pinney J and Davenport A 2011 The effect of vascular access modality on changes in fluid content in the arms as determined by multifrequency bioimpedance Nephrol. Dial. Transplant. 26 227-31
-
(2011)
Nephrol. Dial. Transplant.
, vol.26
, pp. 227-231
-
-
Booth, J.1
Pinney, J.2
Davenport, A.3
-
4
-
-
0030482455
-
Segmental body composition assessed by bioelectrical impedance analysis and DEXA in humans
-
Bracco D, Thiebaud D, Chiolero R L, Landry M, Burckhardt P and Schutz Y 1996 Segmental body composition assessed by bioelectrical impedance analysis and DEXA in humans J. Appl. Physiol. 81 2580-7 (Pubitemid 27043375)
-
(1996)
Journal of Applied Physiology
, vol.81
, Issue.6
, pp. 2580-2587
-
-
Bracco, D.1
Thiebaud, D.2
Chiolero, R.L.3
Landry, M.4
Burckhardt, P.5
Schutz, Y.6
-
5
-
-
0036113534
-
A new technique for establishing dry weight in hemodialysis patients via whole body bioimpedance
-
DOI 10.1046/j.1523-1755.2002.00377.x
-
Chamney P W, Kramer M, Rode C, Kleinekofort W and Wizemann V 2002 A new technique for establishing dry weight in hemodialysis patients via whole body bioimpedance Kidney Int. 61 2250-8 (Pubitemid 34539343)
-
(2002)
Kidney International
, vol.61
, Issue.6
, pp. 2250-2258
-
-
Chamney, P.W.1
Kramer, M.2
Rode, C.3
Kleinekofort, W.4
Wizemann, V.5
-
6
-
-
33846092266
-
A whole-body model to distinguish excess fluid from the hydration of major body tissues
-
Chamney P W, Wabel P, Moissl U M, Muller M J, Bosy-Westphal A, Korth O and Fuller N J 2007 A whole-body model to distinguish excess fluid from the hydration of major body tissues Am. J. Clin. Nutr. 85 80-9 (Pubitemid 46067619)
-
(2007)
American Journal of Clinical Nutrition
, vol.85
, Issue.1
, pp. 80-89
-
-
Chamney, P.W.1
Wabel, P.2
Moissl, U.M.3
Muller, M.J.4
Bosy-Westphal, A.5
Korth, O.6
Fuller, N.J.7
-
7
-
-
0031779420
-
'Dry weight' in dialysis: The history of a concept
-
Charra B 1998 'Dry weight' in dialysis: the history of a concept Nephrol. Dial. Transplant. 13 1882-5
-
(1998)
Nephrol. Dial. Transplant.
, vol.13
, pp. 1883-1885
-
-
Charra, B.1
-
8
-
-
0345258409
-
Volume control, blood pressure and cardiovascular function. Lessons from hemodialysis treatment
-
Charra B and Chazot C 2003 Volume control, blood pressure and cardiovascular function. Lessons from hemodialysis treatment Nephron Physiol. 93 94-101
-
(2003)
Nephron Physiol.
, vol.93
, pp. 94-101
-
-
Charra, B.1
Chazot, C.2
-
9
-
-
0036377061
-
Adjusting dry weight by extracellular volume and body composition in hemodialysis patients
-
Chen Y C, Chen H H, Yeh J C and Chen S Y 2002 Adjusting dry weight by extracellular volume and body composition in hemodialysis patients Nephron 92 91-6
-
(2002)
Nephron
, vol.92
, pp. 91-96
-
-
Chen, Y.C.1
Chen, H.H.2
Yeh, J.C.3
Chen, S.Y.4
-
10
-
-
0034806393
-
Role of bioimpedance spectroscopy in assessment of body water compartments in hemodialysis patients
-
Cox-Reijven P L, Kooman J P, Soeters P B, Van Der Sande F M and Leunissen K M 2001 Role of bioimpedance spectroscopy in assessment of body water compartments in hemodialysis patients Am. J. Kidney Dis. 38 832-8
-
(2001)
Am. J. Kidney Dis.
, vol.38
, pp. 832-838
-
-
Cox-Reijven, P.L.1
Kooman, J.P.2
Soeters, P.B.3
Van Der Sande, F.M.4
Leunissen, K.M.5
-
11
-
-
74049133996
-
Comparison of fluid status in patients treated by different modalities of peritoneal dialysis using multi-frequency bioimpedance
-
Davenport A and Willicombe M 2009 Comparison of fluid status in patients treated by different modalities of peritoneal dialysis using multi-frequency bioimpedance Int. J. Artif. Organs 32 779-86
-
(2009)
Int. J. Artif. Organs
, vol.32
, pp. 779-786
-
-
Davenport, A.1
Willicombe, M.2
-
12
-
-
0030922764
-
Predicting body cell mass with bioimpedance by using theoretical methods: A technological review
-
De Lorenzo A, Andreoli A, Matthie J and Withers P 1997 Predicting body cell mass with bioimpedance by using theoretical methods: a technological review J. Appl. Physiol. 82 1542-58 (Pubitemid 27203864)
-
(1997)
Journal of Applied Physiology
, vol.82
, Issue.5
, pp. 1542-1558
-
-
De Lorenzo, A.1
Andreoli, A.2
Matthie, J.3
Withers, P.4
-
13
-
-
0027520322
-
The adjustment of post dialytic dry weight based on non-invasive measurement of extracellular fluid and blood volumes
-
De Vries J P, Bogaard H J, Kouw P M, Oe L P, Stevens P and De Vries P M 1993 The adjustment of post dialytic dry weight based on non-invasive measurement of extracellular fluid and blood volumes ASAIO J. 39 M368-72
-
(1993)
ASAIO J.
, vol.39
-
-
De Vries, J.P.1
Bogaard, H.J.2
Kouw, P.M.3
Oe, L.P.4
Stevens, P.5
De Vries, P.M.6
-
14
-
-
0033898354
-
Bioimpedance and inferior vena cava diameter for assessment of dialysis dry weight
-
DOI 10.1007/s004670000298
-
Dietel T, Filler G, Grenda R and Wolfish N 2000 Bioimpedance and inferior vena cava diameter for assessment of dialysis dry weight Pediatr. Nephrol. 14 903-7 (Pubitemid 30621297)
-
(2000)
Pediatric Nephrology
, vol.14
, Issue.10-11
, pp. 903-907
-
-
Dietel, T.1
Filler, G.2
Grenda, R.3
Wolfish, N.4
-
16
-
-
1642382811
-
Methods of assessment of volume status and intercompartmental fluid shifts in hemodialysis patients: Implications in clinical practice
-
Ishibe S and Peixoto A J 2004 Methods of assessment of volume status and intercompartmental fluid shifts in hemodialysis patients: implications in clinical practice Semin. Dial. 17 37-43 (Pubitemid 38376690)
-
(2004)
Seminars in Dialysis
, vol.17
, Issue.1
, pp. 37-43
-
-
Ishibe, S.1
Peixoto, A.J.2
-
18
-
-
77955719794
-
Plasma volume, albumin, and fluid status in peritoneal dialysis patients
-
John B, Tan B K, Dainty S, Spanel P, Smith D and Davies S J 2010 Plasma volume, albumin, and fluid status in peritoneal dialysis patients Clin. J. Am. Soc. Nephrol. 5 1463-70
-
(2010)
Clin. J. Am. Soc. Nephrol.
, vol.5
, pp. 1463-1470
-
-
John, B.1
Tan, B.K.2
Dainty, S.3
Spanel, P.4
Smith, D.5
Davies, S.J.6
-
19
-
-
0029943697
-
Multifrequency bioimpedance in assessment of dry weight in haemodialysis
-
20-3
-
Katzarski K, Charra B, Laurent G, Lopot F, Divino-Filho J C, Nisell J and Bergstrom J 1996 Multifrequency bioimpedance in assessment of dry weight in haemodialysis Nephrol. Dial. Transplant. 11 (Suppl. 2) 20-3
-
(1996)
Nephrol. Dial. Transplant.
, vol.11
, pp. 2
-
-
Katzarski, K.1
Charra, B.2
Laurent, G.3
Lopot, F.4
Divino-Filho, J.C.5
Nisell, J.6
Bergstrom, J.7
-
20
-
-
0026556747
-
Assessment of post-dialysis dry weight: An application of the conductivity measurement method
-
Kouw P M, Olthof C G, ter Wee P M, Oe L P, Donker A J, Schneider H and de Vries P M 1992 Assessment of post-dialysis dry weight: an application of the conductivity measurement method Kidney Int. 41 440-4
-
(1992)
Kidney Int.
, vol.41
, pp. 440-444
-
-
Kouw, P.M.1
Olthof, C.G.2
Ter Wee, P.M.3
Oe, L.P.4
Donker, A.J.5
Schneider, H.6
De Vries, P.M.7
-
21
-
-
27444432435
-
Bioimpedance, dry weight and blood pressure control: New methods and consequences
-
Kuhlmann M K, Zhu F, Seibert E and Levin N W 2005 Bioimpedance, dry weight and blood pressure control: new methods and consequences Curr. Opin. Nephrol. Hypertens. 14 543-9 (Pubitemid 41531845)
-
(2005)
Current Opinion in Nephrology and Hypertension
, vol.14
, Issue.6
, pp. 543-549
-
-
Kuhlmann, M.K.1
Zhu, F.2
Seibert, E.3
Levin, N.W.4
-
22
-
-
0029783015
-
Use of bioelectrical impedance analysis measurements in the clinical management of patients undergoing dialysis
-
Kushner R F, de Vries P M and Gudivaka R 1996 Use of bioelectrical impedance analysis measurements in the clinical management of patients undergoing dialysis Am. J. Clin. Nutr. 64 503S-9S (Pubitemid 26320120)
-
(1996)
American Journal of Clinical Nutrition
, vol.64
, Issue.3 SUPPL.
-
-
Kushner, R.F.1
De Vries, P.M.J.M.2
Gudivaka, R.3
-
23
-
-
0025310801
-
Validation of bioelectrical-impedance analysis as a measurement of change in body composition in obesity
-
Kushner R F, Kunigk A, Alspaugh M, Andronis P T, Leitch C A and Schoeller D A 1990 Validation of bioelectrical-impedance analysis as a measurement of change in body composition in obesity Am. J. Clin. Nutr. 52 219-23
-
(1990)
Am. J. Clin. Nutr.
, vol.52
, pp. 219-223
-
-
Kushner, R.F.1
Kunigk, A.2
Alspaugh, M.3
Andronis, P.T.4
Leitch, C.A.5
Schoeller, D.A.6
-
24
-
-
0025313228
-
Assessment of dry body-weight in haemodialysis patients by the biochemical marker cGMP
-
Lauster F, Gerzer R, Weil J, Fulle H J and Schiffl H 1990 Assessment of dry body-weight in haemodialysis patients by the biochemical marker cGMP Nephrol. Dial. Transplant. 5 356-61 (Pubitemid 20218389)
-
(1990)
Nephrology Dialysis Transplantation
, vol.5
, Issue.5
, pp. 356-361
-
-
Lauster, F.1
Gerzer, R.2
Weil, J.3
Fulle, H.-J.4
Schiffl, H.5
-
25
-
-
0029999717
-
Preventing haemodynamic instability in patients at risk for intra-dialytic hypotension
-
11-5
-
Leunissen K M, Kooman J P, van Kuijk W, Van Der Sande F, Luik A J and van Hooff J P 1996 Preventing haemodynamic instability in patients at risk for intra-dialytic hypotension Nephrol. Dial. Transplant. 11 (Suppl. 2) 11-5
-
(1996)
Nephrol. Dial. Transplant.
, vol.11
, pp. 2
-
-
Leunissen, K.M.1
Kooman, J.P.2
Van Kuijk, W.3
Van Der Sande, F.4
Luik, A.J.5
Van Hooff, J.P.6
-
26
-
-
0036698579
-
Age-related extracellular to total body water volume ratio (Ecv/TBW)-can it be used for "dry weight" determination in dialysis patients? Application of multifrequency bioimpedance measurement
-
Lopot F, Nejedly B, Novotna H, Mackova M and Sulkova S 2002 Age-related extracellular to total body water volume ratio (Ecv/TBW)-can it be used for "dry weight" determination in dialysis patients? Application of multifrequency bioimpedance measurement Int. J. Artif. Organs 25 762-9
-
(2002)
Int. J. Artif. Organs
, vol.25
, pp. 762-769
-
-
Lopot, F.1
Nejedly, B.2
Novotna, H.3
MacKova, M.4
Sulkova, S.5
-
27
-
-
0030015067
-
Vena cava diameter measurement for estimation of dry weight in haemodialysis patients
-
24-7
-
Mandelbaum A and Ritz E 1996 Vena cava diameter measurement for estimation of dry weight in haemodialysis patients Nephrol. Dial. Transplant. 11 (Suppl. 2) 24-7
-
(1996)
Nephrol. Dial. Transplant.
, vol.11
, pp. 2
-
-
Mandelbaum, A.1
Ritz, E.2
-
28
-
-
33746557390
-
Body fluid volume determination via body composition spectroscopy in health and disease
-
DOI 10.1088/0967-3334/27/9/012, PII S0967333406222561, 012
-
Moissl U M, et al. 2006 Body fluid volume determination via body composition spectroscopy in health and disease Physiol. Meas. 27 921-33 (Pubitemid 44131442)
-
(2006)
Physiological Measurement
, vol.27
, Issue.9
, pp. 921-933
-
-
Moissl, U.M.1
Wabel, P.2
Chamney, P.W.3
Bosaeus, I.4
Levin, N.W.5
Bosy-Westphal, A.6
Korth, O.7
Muller, M.J.8
Ellegard, L.9
Malmros, V.10
Kaitwatcharachai, C.11
Kuhlmann, M.K.12
Zhu, F.13
Fuller, N.J.14
-
29
-
-
0036973532
-
Combined opto-electronic perometry and bioimpedance to measure objectively the effectiveness of a new treatment intervention for chronic secondary leg lymphedema
-
Moseley A, Piller N and Carati C 2002 Combined opto-electronic perometry and bioimpedance to measure objectively the effectiveness of a new treatment intervention for chronic secondary leg lymphedema Lymphology 35 136-43 (Pubitemid 36169318)
-
(2002)
Lymphology
, vol.35
, Issue.4
, pp. 136-143
-
-
Moseley, A.1
Piller, N.2
Carati, C.3
-
30
-
-
0031970239
-
Identification of operational clues to dry weight prescription in hemodialysis using bioimpedance vector analysis
-
DOI 10.1111/j.1523-1755.1998.00843.x
-
Piccoli A 1998 Identification of operational clues to dry weight prescription in hemodialysis using bioimpedance vector analysis. The Italian Hemodialysis-Bioelectrical Impedance Analysis (HD-BIA) Study Group Kidney Int. 53 1036-43 (Pubitemid 28155681)
-
(1998)
Kidney International
, vol.53
, Issue.4
, pp. 1036-1043
-
-
Piccoli, A.1
-
31
-
-
11144298220
-
Equivalence of information from single versus multiple frequency bioimpedance vector analysis in hemodialysis
-
DOI 10.1111/j.1523-1755.2005.00083.x
-
Piccoli A, Pastori G, Guizzo M, Rebeschini M, Naso A and Cascone C 2005 Equivalence of information from single versus multiple frequency bioimpedance vector analysis in hemodialysis Kidney Int. 67 301-13 (Pubitemid 40021874)
-
(2005)
Kidney International
, vol.67
, Issue.1
, pp. 301-313
-
-
Piccoli, A.1
Pastori, G.2
Guizzo, M.3
Rebeschini, M.4
Naso, A.5
Cascone, C.6
-
32
-
-
0036087958
-
New bioimpedance model accurately predicts lower limb muscle volume: Validation by magnetic resonance imaging
-
Salinari S, Bertuzzi A, Mingrone G, Capristo E, Pietrobelli A, Campioni P, Greco A V and Heymsfield S B 2002 New bioimpedance model accurately predicts lower limb muscle volume: validation by magnetic resonance imaging Am. J. Physiol. Endocrinol. Metab. 282 E960-6
-
(2002)
Am. J. Physiol. Endocrinol. Metab.
, vol.282
-
-
Salinari, S.1
Bertuzzi, A.2
Mingrone, G.3
Capristo, E.4
Pietrobelli, A.5
Campioni, P.6
Greco, A.V.7
Heymsfield, S.B.8
-
33
-
-
0035162645
-
Preserving central blood volume: Changes in body fluid compartments during hemodialysis
-
Shulman T, Heidenheim A P, Kianfar C, Shulman S M and Lindsay R M 2001 Preserving central blood volume: changes in body fluid compartments during hemodialysis ASAIO J. 47 615-8 (Pubitemid 33064152)
-
(2001)
ASAIO Journal
, vol.47
, Issue.6
, pp. 615-618
-
-
Shulman, T.1
Heidenheim, A.P.2
Kianfar, C.3
Shulman, S.M.4
Lindsay, R.M.5
-
34
-
-
0033972819
-
Bioimpedance resistance ratios for the evaluation of dry weight in hemodialysis
-
Spiegel D M, Bashir K and Fisch B 2000 Bioimpedance resistance ratios for the evaluation of dry weight in hemodialysis Clin. Nephrol. 53 108-14 (Pubitemid 30082244)
-
(2000)
Clinical Nephrology
, vol.53
, Issue.2
, pp. 108-114
-
-
Spiegel, D.M.1
Bashir, K.2
Fisch, B.3
-
35
-
-
0034824205
-
Measurement of body fat using leg to leg bioimpedance
-
DOI 10.1136/adc.85.3.263
-
Sung R Y, Lau P, Yu C W, Lam P K and Nelson E A 2001 Measurement of body fat using leg to leg bioimpedance Arch. Dis. Child. 85 263-7 (Pubitemid 32822393)
-
(2001)
Archives of Disease in Childhood
, vol.85
, Issue.3
, pp. 263-267
-
-
Sung, R.Y.T.1
Lau, P.2
Yu, C.W.3
Lam, P.K.W.4
Nelson, E.A.S.5
-
36
-
-
78549290317
-
The relationship between chronic volume overload and elevated blood pressure in hemodialysis patients: Use of bioimpedance provides a different perspective from echocardiography and biomarker methodologies
-
Voroneanu L, Cusai C, Hogas S, Ardeleanu S, Onofriescu M, Nistor I, Prisada O, Sascau R, Goldsmith D and Covic A 2010 The relationship between chronic volume overload and elevated blood pressure in hemodialysis patients: use of bioimpedance provides a different perspective from echocardiography and biomarker methodologies Int. Urol. Nephrol. 42 789-97
-
(2010)
Int. Urol. Nephrol.
, vol.42
, pp. 789-797
-
-
Voroneanu, L.1
Cusai, C.2
Hogas, S.3
Ardeleanu, S.4
Onofriescu, M.5
Nistor, I.6
Prisada, O.7
Sascau, R.8
Goldsmith, D.9
Covic, A.10
-
37
-
-
29144444667
-
Relationship between filtration coefficients of microvasculature and levels of atrial natriuretic peptide or echocardiographic measurements
-
DOI 10.1159/000088214
-
Yashiro M, Watanabe H, Tomita M, Yamadori N and Muso E 2005 Relationship between filtration coefficients of microvasculature and levels of atrial natriuretic peptide or echocardiographic measurements Blood Purif. 23 431-9 (Pubitemid 41816070)
-
(2005)
Blood Purification
, vol.23
, Issue.6
, pp. 431-439
-
-
Yashiro, M.1
Watanabe, H.2
Tomita, M.3
Yamadori, N.4
Muso, E.5
-
38
-
-
45749103314
-
A method for the estimation of hydration state during hemodialysis using a calf bioimpedance technique
-
Zhu F, Kuhlmann M K, Kotanko P, Seibert E, Leonard E F and Levin N W 2008a A method for the estimation of hydration state during hemodialysis using a calf bioimpedance technique Physiol. Meas. 29 S503-16
-
(2008)
Physiol. Meas.
, vol.29
-
-
Zhu, F.1
Kuhlmann, M.K.2
Kotanko, P.3
Seibert, E.4
Leonard, E.F.5
Levin, N.W.6
-
39
-
-
23044488899
-
Body composition modeling in the calf using an equivalent circuit model of multi-frequency bioimpedance analysis
-
Zhu F, Leonard E F and Levin N W 2005 Body composition modeling in the calf using an equivalent circuit model of multi-frequency bioimpedance analysis Physiol. Meas. 26 S133-43
-
(2005)
Physiol. Meas.
, vol.26
-
-
Zhu, F.1
Leonard, E.F.2
Levin, N.W.3
-
40
-
-
45749119581
-
Extracellular fluid redistribution during hemodialysis: Bioimpedance measurement and model
-
Zhu F, Leonard E F and Levin N W 2008b Extracellular fluid redistribution during hemodialysis: bioimpedance measurement and model Physiol. Meas. 29 S491-501
-
(2008)
Physiol. Meas.
, vol.29
-
-
Zhu, F.1
Leonard, E.F.2
Levin, N.W.3
-
41
-
-
0037256790
-
Methods and reproducibility of measurement of resistivity in the calf using regional bioimpedance analysis
-
DOI 10.1159/000067855
-
Zhu F, Sarkar S, Kaitwatcharachai C, Greenwood R, Ronco C and Levin N W 2003 Methods and reproducibility of measurement of resistivity in the calf using regional bioimpedance analysis Blood Purif. 21 131-6 (Pubitemid 36173360)
-
(2003)
Blood Purification
, vol.21
, Issue.1
, pp. 131-136
-
-
Zhu, F.1
Sarkar, S.2
Kaitwatcharachai, C.3
Greenwood, R.4
Ronco, C.5
Levin, N.W.6
-
42
-
-
0032807622
-
Sum of segmental bioimpedance analysis during ultrafiltration and hemodialysis reduces sensitivity to changes in body position
-
DOI 10.1046/j.1523-1755.1999.00588.x
-
Zhu F, Schneditz D and Levin N W 1999 Sum of segmental bioimpedance analysis during ultrafiltration and hemodialysis reduces sensitivity to changes in body position Kidney Int. 56 692-9 (Pubitemid 29353169)
-
(1999)
Kidney International
, vol.56
, Issue.2
, pp. 692-699
-
-
Zhu, F.1
Schneditz, D.2
Levin, N.W.3
-
43
-
-
0032170001
-
Validation of changes in extracellular volume measured during hemodialysis using a segmental bioimpedance technique
-
Zhu F, Schneditz D, Wang E, Martin K, Morris A T and Levin N W 1998 Validation of changes in extracellular volume measured during hemodialysis using a segmental bioimpedance technique ASAIO J. 44 M541-5
-
(1998)
ASAIO J.
, vol.44
-
-
Zhu, F.1
Schneditz, D.2
Wang, E.3
Martin, K.4
Morris, A.T.5
Levin, N.W.6
-
44
-
-
0035038272
-
Dry weight in hemodialysis: Volemic control
-
Zucchelli P and Santoro A 2001 Dry weight in hemodialysis: volemic control Semin. Nephrol. 21 286-90 (Pubitemid 32390924)
-
(2001)
Seminars in Nephrology
, vol.21
, Issue.3
, pp. 286-290
-
-
Zucchelli, P.1
Santoro, A.2
|