메뉴 건너뛰기




Volumn 33, Issue 6, 2011, Pages 1291-1300

Dual-temporal resolution dynamic contrast-enhanced MRI protocol for blood-brain barrier permeability measurement in enhancing multiple sclerosis lesions

Author keywords

blood brain barrier; DCE MRI; multiple sclerosis

Indexed keywords

GADOBUTROL; GADOLINIUM PENTETATE;

EID: 79958259262     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.22565     Document Type: Article
Times cited : (41)

References (28)
  • 1
    • 0037161235 scopus 로고    scopus 로고
    • MRI in the diagnosis and management of multiple sclerosis
    • Arnold DL, Matthews PM,. MRI in the diagnosis and management of multiple sclerosis. Neurology 2002; 58: S23-31. (Pubitemid 34411850)
    • (2002) Neurology , vol.58 , Issue.8 SUPPL. 5
    • Arnold, D.L.1    Matthews, P.M.2
  • 2
    • 0037161249 scopus 로고    scopus 로고
    • MRI techniques to monitor MS evolution: The present and the future
    • Filippi M, Grossman RI,. MRI techniques to monitor MS evolution: the present and the future. Neurology 2002; 58: 1147-1153. (Pubitemid 34411856)
    • (2002) Neurology , vol.58 , Issue.8 , pp. 1147-1153
    • Filippi, M.1    Grossman, R.I.2
  • 3
    • 0025047826 scopus 로고
    • Quantitation of blood-brain barrier defect by magnetic resonance imaging and gadolinium-DTPA in patients with multiple sclerosis and brain tumors
    • Larsson HBW, Stubgaard M, Frederiksen JL, Jensen M, Henriksen O, Paulson OB,. Quantitation of blood-brain barrier defect by magnetic resonance imaging and gadolinium-DTPA in patients with multiple sclerosis and brain tumors. Magn Reson Med 1990; 16: 117-131. (Pubitemid 20353802)
    • (1990) Magnetic Resonance in Medicine , vol.16 , Issue.1 , pp. 117-131
    • Larsson, H.B.W.1    Stubgaard, M.2    Frederiksen, J.L.3    Jensen, M.4    Henriksen, O.5    Paulson, O.B.6
  • 4
    • 0026011540 scopus 로고
    • Measurement of the blood-brain barrier permeability and leakage space using dynamic MR imaging. 1. Fundamental concepts
    • Tofts PS, Kermode AG,. Measurement of the blood-brain barrier permeability and leakage space using dynamic MR imaging. 1. Fundamental concepts. Magn Reson Med 1991; 17: 357-367.
    • (1991) Magn Reson Med , vol.17 , pp. 357-367
    • Tofts, P.S.1    Kermode, A.G.2
  • 6
    • 20344399898 scopus 로고    scopus 로고
    • Quantitative pharmacokinetic analysis of DCE-MRI data without an arterial input function: A reference region model
    • DOI 10.1016/j.mri.2005.02.013, PII S0730725X05001359
    • Yankeelov TE, Luci JJ, Lepage M, et al. Quantitative pharmacokinetic analysis of DCE-MRI data without an arterial input function: a reference region model. Magn Reson Imaging 2005; 23: 519-529. (Pubitemid 40779238)
    • (2005) Magnetic Resonance Imaging , vol.23 , Issue.4 , pp. 519-529
    • Yankeelov, T.E.1    Luci, J.J.2    Lepage, M.3    Li, R.4    Debusk, L.5    Lin, P.C.6    Price, R.R.7    Gore, J.C.8
  • 7
    • 66149093117 scopus 로고    scopus 로고
    • Comparison of model-based arterial input functions for dynamic contrast-enhanced MRI in tumor bearing rats
    • McGrath DM, Bradley DP, Tessier JL, Lacey T, Taylor CJ, Parker GJ,. Comparison of model-based arterial input functions for dynamic contrast-enhanced MRI in tumor bearing rats. Magn Reson Med 2009; 61: 1173-1184.
    • (2009) Magn Reson Med , vol.61 , pp. 1173-1184
    • McGrath, D.M.1    Bradley, D.P.2    Tessier, J.L.3    Lacey, T.4    Taylor, C.J.5    Parker, G.J.6
  • 9
    • 70449411152 scopus 로고    scopus 로고
    • Measurement of brain perfusion, blood volume, and blood-brain barrier permeability, using dynamic contrast-enhanced T(1)-weighted MRI at 3 Tesla
    • Larsson HB, Courivaud F, Rostrup E, Hansen AE,. Measurement of brain perfusion, blood volume, and blood-brain barrier permeability, using dynamic contrast-enhanced T(1)-weighted MRI at 3 Tesla. Magn Reson Med 2009; 62: 1270-1281.
    • (2009) Magn Reson Med , vol.62 , pp. 1270-1281
    • Larsson, H.B.1    Courivaud, F.2    Rostrup, E.3    Hansen, A.E.4
  • 11
    • 67650035443 scopus 로고    scopus 로고
    • Quantification of cerebral blood flow, cerebral blood volume, and blood-brain-barrier leakage with DCE-MRI
    • Sourbron S, Ingrisch M, Siefert A, Reiser M, Herrmann K,. Quantification of cerebral blood flow, cerebral blood volume, and blood-brain-barrier leakage with DCE-MRI. Magn Reson Med 2009; 62: 205-217.
    • (2009) Magn Reson Med , vol.62 , pp. 205-217
    • Sourbron, S.1    Ingrisch, M.2    Siefert, A.3    Reiser, M.4    Herrmann, K.5
  • 13
    • 67649476210 scopus 로고    scopus 로고
    • Efficacy of treatment of MS with IFNbeta-1b or glatiramer acetate by monthly brain MRI in the BECOME study
    • Cadavid D, Wolansky LJ, Skurnick J, et al. Efficacy of treatment of MS with IFNbeta-1b or glatiramer acetate by monthly brain MRI in the BECOME study. Neurology 2009; 72: 1976-1983.
    • (2009) Neurology , vol.72 , pp. 1976-1983
    • Cadavid, D.1    Wolansky, L.J.2    Skurnick, J.3
  • 14
    • 9044234404 scopus 로고    scopus 로고
    • Comparison of triple dose versus standard dose gadolinium-DTPA for detection of MRI enhancing lesions in patients with MS
    • Filippi M, Yousry T, Campi A, et al. Comparison of triple dose versus standard dose gadolinium-DTPA for detection of MRI enhancing lesions in patients with MS. Neurology 1996; 46: 379-378.
    • (1996) Neurology , vol.46 , pp. 379-378
    • Filippi, M.1    Yousry, T.2    Campi, A.3
  • 18
    • 0037370514 scopus 로고    scopus 로고
    • 2 mapping using gradient recalled acquisition in the steady state
    • DOI 10.1002/mrm.10407
    • Deoni SC, Rutt BK, Peters TM,. Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state. Magn Reson Med 2003; 49: 515-526. (Pubitemid 36262820)
    • (2003) Magnetic Resonance in Medicine , vol.49 , Issue.3 , pp. 515-526
    • Deoni, S.C.L.1    Rutt, B.K.2    Peters, T.M.3
  • 19
    • 0033766487 scopus 로고    scopus 로고
    • Gd-DTPA relaxivity depends on macromolecular content
    • Stanisz GJ, Henkelman RM,. Gd-DTPA relaxivity depends on macromolecular content. Magn Reson Med 2000; 44: 665-667.
    • (2000) Magn Reson Med , vol.44 , pp. 665-667
    • Stanisz, G.J.1    Henkelman, R.M.2
  • 20
    • 27544442176 scopus 로고    scopus 로고
    • Comparison of magnetic properties of MRI contrast media solutions at different magnetic field strengths
    • DOI 10.1097/01.rli.0000184756.66360.d3
    • Rohrer M, Bauer H, Mintorovitch J, Requardt M, Weinmann HJ,. Comparison of magnetic properties of MRI contrast media solutions at different magnetic field strengths. Invest Radiol 2005; 40: 715-724. (Pubitemid 41546838)
    • (2005) Investigative Radiology , vol.40 , Issue.11 , pp. 715-724
    • Rohrer, M.1    Bauer, H.2    Mintorovitch, J.3    Requardt, M.4    Weinmann, H.-J.5
  • 22
    • 0342298515 scopus 로고    scopus 로고
    • Improved 3D quantitative mapping of blood volume and endothelial permeability in brain tumors
    • Li K-L, Zhu XP, Waterton J, Jackson A,. Improved 3D quantitative mapping of blood volume and endothelial permeability in brain tumors. J Magn Reson Imaging 2000; 12: 347-357. (Pubitemid 30612881)
    • (2000) Journal of Magnetic Resonance Imaging , vol.12 , Issue.2 , pp. 347-357
    • Li, K.-L.1    Zhu, X.P.2    Waterton, J.3    Jackson, A.4
  • 23
    • 42449143939 scopus 로고    scopus 로고
    • Uncertainty and bias in contrast concentration measurements using spoiled gradient echo pulse sequences
    • DOI 10.1088/0031-9155/53/9/010, PII S0031915508575142
    • Schabel MC, Parker DL,. Uncertainty and bias in contrast concentration measurements using spoiled gradient echo pulse sequences. Phys Med Biol 2008; 53: 2345-2373. (Pubitemid 351570916)
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.9 , pp. 2345-2373
    • Schabel, M.C.1    Parker, D.L.2
  • 24
    • 0031404162 scopus 로고    scopus 로고
    • Modeling tracer kinetics in dynamic Gd-DTPA MR imaging
    • DOI 10.1002/jmri.1880070113
    • Tofts PS,. Modeling tracer kinetics in dynamic Gd-DTPA MR imaging. J Magn Reson Imaging 1997; 7: 91-101. (Pubitemid 28365643)
    • (1997) Journal of Magnetic Resonance Imaging , vol.7 , Issue.1 , pp. 91-101
    • Tofts, P.S.1
  • 25
    • 4744373442 scopus 로고    scopus 로고
    • Algorithms for calculation of kinetic parameters from T1-weighted dynamic contrast-enhanced magnetic resonance imaging
    • DOI 10.1002/jmri.20161
    • Horsfield MA, Morgan B,. Algorithms for calculation of kinetic parameters from T1-weighted dynamic contrast-enhanced magnetic resonance imaging. J Magn Reson Imaging 2004; 20: 723-729. (Pubitemid 39313750)
    • (2004) Journal of Magnetic Resonance Imaging , vol.20 , Issue.4 , pp. 723-729
    • Horsfield, M.A.1    Morgan, B.2
  • 26
    • 60349087123 scopus 로고    scopus 로고
    • Improved bolus arrival time and arterial input function estimation for tracer kinetic analysis in DCE-MRI
    • Singh A, Rathore RK, Haris M, Verma SK, Husain N, Gupta RK,. Improved bolus arrival time and arterial input function estimation for tracer kinetic analysis in DCE-MRI. J Magn Reson Imaging 2009; 29: 166-176.
    • (2009) J Magn Reson Imaging , vol.29 , pp. 166-176
    • Singh, A.1    Rathore, R.K.2    Haris, M.3    Verma, S.K.4    Husain, N.5    Gupta, R.K.6
  • 27
    • 0037310635 scopus 로고    scopus 로고
    • Measurements of extracellular volume fraction and capillary permeability in tissues using dynamic spin-lattice relaxometry: Studies in rabbit muscles
    • DOI 10.1016/S0730-725X(02)00638-0
    • Vincensini D, Dedieu V, Renou JP, Otal P, Joffre F,. Measurements of extracellular volume fraction and capillary permeability in tissues using dynamic spin-lattice relaxometry: studies in rabbit muscles. Magn Reson Imaging 2003; 21: 85-93. (Pubitemid 36418726)
    • (2003) Magnetic Resonance Imaging , vol.21 , Issue.2 , pp. 85-93
    • Vincensini, D.1    Dedieu, V.2    Renou, J.P.3    Otal, P.4    Joffre, F.5
  • 28
    • 0029930790 scopus 로고    scopus 로고
    • Optimal detection of blood-brain barrier defects with Gd-DTPA MRI - The influences of delayed imaging and optimised repetition time
    • DOI 10.1016/0730-725X(96)00023-9
    • Tofts PS,. Optimal detection of blood-brain barrier defects with Gd-DTPA MRI-the influences of delayed imaging and optimised repetition time. Magn Reson Imaging 1996; 14: 373-380. (Pubitemid 26195072)
    • (1996) Magnetic Resonance Imaging , vol.14 , Issue.4 , pp. 373-380
    • Tofts, P.S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.