메뉴 건너뛰기




Volumn 39, Issue 2, 2011, Pages 72-76

Patient weight-based acquisition protocols to optimize18F-FDG PET/CT image quality

Author keywords

18F FDG; Acquisition protocols; Image quality; Patient weight; PET CT

Indexed keywords

FLUORODEOXYGLUCOSE F 18; LUTETIUM; LUTETIUM OXYORTHOSILICATE; UNCLASSIFIED DRUG;

EID: 79958232400     PISSN: 00914916     EISSN: None     Source Type: Journal    
DOI: 10.2967/jnmt.110.081661     Document Type: Article
Times cited : (37)

References (11)
  • 1
    • 40449093361 scopus 로고    scopus 로고
    • Recommendations on the use of 18F-FDG PET in oncology
    • Fletcher JW, Djulbegovic B, Soares HP, et al. Recommendations on the use of 18F-FDG PET in oncology. J Nucl Med. 2008;49:480-508.
    • (2008) J Nucl Med , vol.49 , pp. 480-508
    • Fletcher, J.W.1    Djulbegovic, B.2    Soares, H.P.3
  • 2
    • 2642561322 scopus 로고    scopus 로고
    • Impact of patient weight and emission scan duration on PET/CT image quality and lesion detectability
    • Halpern BS, Dahlbom M, Quon A, et al. Impact of patient weight and emission scan duration on PET/CT image quality and lesion detectability. J Nucl Med. 2004;45:797-801.
    • (2004) J Nucl Med , vol.45 , pp. 797-801
    • Halpern, B.S.1    Dahlbom, M.2    Quon, A.3
  • 3
    • 19644389147 scopus 로고    scopus 로고
    • Optimizing imaging protocols for overweight and obese patients: a lutetium orthosilicate PET/CT study
    • Halpern BS, Dahlbom M, Auerbach MA, et al. Optimizing imaging protocols for overweight and obese patients: a lutetium orthosilicate PET/CT study. J Nucl Med. 2005;46:603-607.
    • (2005) J Nucl Med , vol.46 , pp. 603-607
    • Halpern, B.S.1    Dahlbom, M.2    Auerbach, M.A.3
  • 4
    • 0346734290 scopus 로고    scopus 로고
    • Optimal dose of 18F-FDG required for whole-body PET using an LSO PET camera
    • Everaert H, Vanhove C, Lahoutte T, et al. Optimal dose of 18F-FDG required for whole-body PET using an LSO PET camera. Eur J Nucl Med Mol Imaging. 2003;30:1615-1619.
    • (2003) Eur J Nucl Med Mol Imaging , vol.30 , pp. 1615-1619
    • Everaert, H.1    Vanhove, C.2    Lahoutte, T.3
  • 6
    • 1642291821 scopus 로고    scopus 로고
    • Positron emission tomography. a review of basic principles, scanner design and performance, and current systems
    • Zanzonico P. Positron emission tomography. a review of basic principles, scanner design and performance, and current systems. Semin Nucl Med. 2004;34:87-111.
    • (2004) Semin Nucl Med , vol.34 , pp. 87-111
    • Zanzonico, P.1
  • 7
    • 41549158607 scopus 로고    scopus 로고
    • Positron emission tomography/computed tomography
    • Townsend DW. Positron emission tomography/computed tomography. Semin Nucl Med. 2008;38:152-166.
    • (2008) Semin Nucl Med , vol.38 , pp. 152-166
    • Townsend, D.W.1
  • 8
    • 33644828174 scopus 로고    scopus 로고
    • Optimizing injected dose in clinical PET by accurately modeling the counting-rate response functions specific to individual patient scans
    • Watson CC, Casey ME, Bendriem B, et al. Optimizing injected dose in clinical PET by accurately modeling the counting-rate response functions specific to individual patient scans. J Nucl Med. 2005;46:1825-1834.
    • (2005) J Nucl Med , vol.46 , pp. 1825-1834
    • Watson, C.C.1    Casey, M.E.2    Bendriem, B.3
  • 9
    • 33644874714 scopus 로고    scopus 로고
    • Performance characteristics obtained for a new 3-dimensional lutetium oxyorthosilicate-based whole-body PET/CT scanner with the national electrical manufacturers association NU 2-2001 standard
    • Brambilla M, Secco C, Dominietto M, Matheoud R, Sacchetti G, Inglese E. Performance characteristics obtained for a new 3-dimensional lutetium oxyorthosilicate-based whole-body PET/CT scanner with the national electrical manufacturers association NU 2-2001 standard. J Nucl Med. 2005;46:2083-2091.
    • (2005) J Nucl Med , vol.46 , pp. 2083-2091
    • Brambilla, M.1    Secco, C.2    Dominietto, M.3    Matheoud, R.4    Sacchetti, G.5    Inglese, E.6
  • 10
    • 66649105798 scopus 로고    scopus 로고
    • Comparison of imaging protocols for 18F-FDG PET/CT in overweight patients: optimizing scan duration versus administered dose
    • Masuda Y, Kondo C, Matsuo Y, Uetani M, Kusakabe K. Comparison of imaging protocols for 18F-FDG PET/CT in overweight patients: optimizing scan duration versus administered dose. J Nucl Med. 2009;50:844-848.
    • (2009) J Nucl Med , vol.50 , pp. 844-848
    • Masuda, Y.1    Kondo, C.2    Matsuo, Y.3    Uetani, M.4    Kusakabe, K.5
  • 11
    • 0037870114 scopus 로고    scopus 로고
    • Impact of body habitus on quantitative and qualitative image quality in whole-body FDG-PET
    • Tatsumi M, Clark PA, Nakamoto Y, Wahl RL. Impact of body habitus on quantitative and qualitative image quality in whole-body FDG-PET. Eur J Nucl Med Mol Imaging. 2003;30:40-45.
    • (2003) Eur J Nucl Med Mol Imaging , vol.30 , pp. 40-45
    • Tatsumi, M.1    Clark, P.A.2    Nakamoto, Y.3    Wahl, R.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.