-
1
-
-
0036250657
-
The public health impact of Alzheimer's disease, 2000-2050: Potential implication of treatment advances
-
DOI 10.1146/annurev.publhealth.23.100901.140525
-
PD Sloane S Zimmerman C Suchindran P Reed L Wang M Boustani, et al. 2002 The public health impact of Alzheimer's disease, 2000-2050: potential implication of treatment advances Annu Rev Public Health 23 213 231 11910061 10.1146/annurev.publhealth.23.100901.140525 (Pubitemid 34508073)
-
(2002)
Annual Review of Public Health
, vol.23
, pp. 213-231
-
-
Sloane, P.D.1
Zimmerman, S.2
Suchindran, C.3
Reed, P.4
Wang, L.5
Boustani, M.6
Sudha, S.7
-
2
-
-
10744232413
-
Imaging Brain Amyloid in Alzheimer's Disease with Pittsburgh Compound-B
-
DOI 10.1002/ana.20009
-
WE Klunk H Engler A Nordberg Y Wang G Blomqvist DP Holt, et al. 2004 Imaging brain amyloid in Alzheimer's disease with Pittsburgh Compound-B Ann Neurol 55 306 319 14991808 10.1002/ana.20009 1:CAS:528:DC%2BD2cXisFKntb8%3D (Pubitemid 38269583)
-
(2004)
Annals of Neurology
, vol.55
, Issue.3
, pp. 306-319
-
-
Klunk, W.E.1
Engler, H.2
Nordberg, A.3
Wang, Y.4
Blomqvist, G.5
Holt, D.P.6
Bergstrom, M.7
Savitcheva, I.8
Huang, G.-F.9
Estrada, S.10
Ausen, B.11
Debnath, M.L.12
Barletta, J.13
Price, J.C.14
Sandell, J.15
Lopresti, B.J.16
Wall, A.17
Koivisto, P.18
Antoni, G.19
Mathis, C.A.20
Langstrom, B.21
more..
-
3
-
-
77953937194
-
In vivo imaging of amyloid deposition in Alzheimer disease using the radioligand 18F-AV-45 (Flobetapir F 18)
-
20501908 10.2967/jnumed.109.069088 1:CAS:528:DC%2BC3cXosl2ksb4%3D
-
DF Wong PB Rosenberg Y Zhou A Kumar V Raymont HT Ravert, et al. 2010 In vivo imaging of amyloid deposition in Alzheimer disease using the radioligand 18F-AV-45 (Flobetapir F 18) J Nucl Med 51 913 920 20501908 10.2967/jnumed.109. 069088 1:CAS:528:DC%2BC3cXosl2ksb4%3D
-
(2010)
J Nucl Med
, vol.51
, pp. 913-920
-
-
Wong, D.F.1
Rosenberg, P.B.2
Zhou, Y.3
Kumar, A.4
Raymont, V.5
Ravert, H.T.6
-
4
-
-
38149081191
-
Imaging of amyloid β in Alzheimer's disease with 18F-BAY94-9172, a novel PET tracer: Proof of mechanism
-
18191617 10.1016/S1474-4422(08)70001-2 1:CAS:528:DC%2BD1cXis1WmsLw%3D
-
CC Rowe U Ackerman W Browne R Mulligan KL Pike G O'Keefe, et al. 2008 Imaging of amyloid β in Alzheimer's disease with 18F-BAY94-9172, a novel PET tracer: proof of mechanism Lancet Neurol. 7 129 135 18191617 10.1016/S1474-4422(08)70001-2 1:CAS:528:DC%2BD1cXis1WmsLw%3D
-
(2008)
Lancet Neurol.
, vol.7
, pp. 129-135
-
-
Rowe, C.C.1
Ackerman, U.2
Browne, W.3
Mulligan, R.4
Pike, K.L.5
O'Keefe, G.6
-
5
-
-
77956384880
-
18F-flutemetamol amyloid imaging in Alzheimer disease and mild cognitive impairment: A phase 2 trial
-
20687209 10.1002/ana.22068
-
R Vandenberghe K Van Laere A Ivanoiu E Salmon C Bastin E Triau, et al. 2010 18F-flutemetamol amyloid imaging in Alzheimer disease and mild cognitive impairment: a phase 2 trial Ann Neurol 68 319 329 20687209 10.1002/ana.22068
-
(2010)
Ann Neurol
, vol.68
, pp. 319-329
-
-
Vandenberghe, R.1
Van Laere, K.2
Ivanoiu, A.3
Salmon, E.4
Bastin, C.5
Triau, E.6
-
6
-
-
34250315240
-
Partial-volume effect in PET tumor imaging
-
DOI 10.2967/jnumed.106.035774
-
M Soret SL Bacharach I Buvat 2007 Partial-volume effect in PET tumor imaging J Nucl Med 48 932 945 17504879 10.2967/jnumed.106.035774 (Pubitemid 46909922)
-
(2007)
Journal of Nuclear Medicine
, vol.48
, Issue.6
, pp. 932-945
-
-
Soret, M.1
Bacharach, S.L.2
Buvat, I.3
-
7
-
-
0032925257
-
Hippocampal and entorhinal cortex atrophy in frontotemporal dementia and Alzheimer's disease
-
G Frisoni M Laakso A Beltramello C Geroldi A Bianchetti H Soininen, et al. 1999 Hippocampal and entorhinal cortex atrophy in frontotemporal dementia and Alzheimer's disease Neurology 52 91 100 9921854 1:STN:280: DyaK1M7hvVyhtQ%3D%3D (Pubitemid 29044405)
-
(1999)
Neurology
, vol.52
, Issue.1
, pp. 91-100
-
-
Frisoni, G.B.1
Laakso, M.P.2
Beltramello, A.3
Geroldi, C.4
Bianchetti, A.5
Soininen, H.6
Trabucchi, M.7
-
8
-
-
0037319171
-
Dynamics of gray matter loss in Alzheimer's disease
-
PM Thompson KM Hayashi G de Zubicaray AL Janke SE Rose J Semple, et al. 2003 Dynamics of gray matter loss in Alzheimer's disease J Neurosci 23 994 1005 12574429 1:CAS:528:DC%2BD3sXhtlOrt7Y%3D (Pubitemid 36206191)
-
(2003)
Journal of Neuroscience
, vol.23
, Issue.3
, pp. 994-1005
-
-
Thompson, P.M.1
Hayashi, K.M.2
De Zubicaray, G.3
Janke, A.L.4
Rose, S.E.5
Semple, J.6
Herman, D.7
Hong, M.S.8
Dittmer, S.S.9
Doddrell, D.M.10
Toga, A.W.11
-
9
-
-
27144515872
-
Brain atrophy rates predict subsequent clinical conversion in normal elderly and amnestic MCI
-
DOI 10.1212/01.wnl.0000180958.22678.91
-
CR Jack MM Shiung SD Weigand PC O'Brien JL Gunter BF Boeve, et al. 2005 Brain atrophy rates predict subsequent clinical conversion in normal elderly and amnestic MCI Neurology 65 1227 1231 16247049 10.1212/01.wnl.0000180958.22678.91 (Pubitemid 41508215)
-
(2005)
Neurology
, vol.65
, Issue.8
, pp. 1227-1231
-
-
Jack Jr., C.R.1
Shiung, M.M.2
Weigand, S.D.3
O'Brien, P.C.4
Gunter, J.L.5
Boeve, B.F.6
Knopman, D.S.7
Smith, G.E.8
Ivnik, R.J.9
Tangalos, E.G.10
Petersen, R.C.11
-
10
-
-
38749098142
-
Deconvolution-based partial volume correction in Raclopride-PET and Monte Carlo comparison to MR-based method
-
18077187 10.1016/j.neuroimage.2007.10.038
-
J Tohka A Reilhac 2008 Deconvolution-based partial volume correction in Raclopride-PET and Monte Carlo comparison to MR-based method Neuroimage 39 1570 1584 18077187 10.1016/j.neuroimage.2007.10.038
-
(2008)
Neuroimage
, vol.39
, pp. 1570-1584
-
-
Tohka, J.1
Reilhac, A.2
-
11
-
-
16544364015
-
Performance characteristics of a newly developed PET/CT scanner using NEMA standards in 2D and 3D modes
-
O Mawlawi DA Podoloff S Kohlmyer JJ Williams CW Stearns RF Culp, et al. 2004 Performance characteristics of a newly developed PET/CT scanner using NEMA standards in 2D and 3D modes J Nucl Med 45 1734 1742 15471842 (Pubitemid 47618484)
-
(2004)
Journal of Nuclear Medicine
, vol.45
, Issue.10
, pp. 1734-1742
-
-
Mawlawi, O.1
Podoloff, D.A.2
Kohlmyer, S.3
Williams, J.J.4
Stearns, C.W.5
Culp, R.F.6
Macapinlac, H.7
-
12
-
-
34250373877
-
Partial-volume correction in PET: Validation of an iterative postreconstruction method with phantom and patient data
-
DOI 10.2967/jnumed.106.035576
-
BK Teo Y Seo SL Bacharach JA Carrasquillo SK Libutti H Shukla, et al. 2007 Partial-volume correction in PET: validation of an iterative postreconstruction method with phantom and patient data J Nucl Med 48 802 810 17475970 (Pubitemid 47604982)
-
(2007)
Journal of Nuclear Medicine
, vol.48
, Issue.5
, pp. 802-810
-
-
Teo, B.-K.1
Seo, Y.2
Bacharach, S.L.3
Carrasquillo, J.A.4
Libutti, S.K.5
Shukla, H.6
Hasegawa, B.H.7
Hawkins, R.A.8
Franc, B.L.9
-
15
-
-
0026700928
-
Measurement of radiotracer concentration in brain gray matter using positron emission tomography: MRI-based correction for partial volume effects
-
1618936 10.1038/jcbfm.1992.81
-
HW Müller-Gärtner JM Links JL Prince RN Bryan E McVeigh JP Leal, et al. 1992 Measurement of radiotracer concentration in brain gray matter using positron emission tomography: MRI-based correction for partial volume effects J Cereb Blood Flow Metab 12 571 583 1618936 10.1038/jcbfm.1992.81
-
(1992)
J Cereb Blood Flow Metab
, vol.12
, pp. 571-583
-
-
Müller-Gärtner, H.W.1
Links, J.M.2
Prince, J.L.3
Bryan, R.N.4
McVeigh, E.5
Leal, J.P.6
-
16
-
-
0031955835
-
Correction for partial volume effects in PET: Principle and validation
-
OG Rousset Y Ma AC Evans 1998 Correction for partial volume effects in PET: principle and validation J Nucl Med 39 904 911 9591599 1:STN:280: DyaK1c3lt1aksQ%3D%3D (Pubitemid 28216748)
-
(1998)
Journal of Nuclear Medicine
, vol.39
, Issue.5
, pp. 904-911
-
-
Rousset, O.G.1
Ma, Y.2
Evans, A.C.3
-
17
-
-
0001050714
-
An iterative technique for the rectification of observed distributions
-
10.1086/111605
-
L Lucy 1974 An iterative technique for the rectification of observed distributions Astron J 79 745 754 10.1086/111605
-
(1974)
Astron J
, vol.79
, pp. 745-754
-
-
Lucy, L.1
-
18
-
-
38749099178
-
A Monte Carlo study of deconvolution algorithms for partial volume correction in quantitative PET
-
IEEE doi: 10.1109/NSSMIC.2006.353719
-
Tohka J, Reilhac A. A Monte Carlo study of deconvolution algorithms for partial volume correction in quantitative PET. Nuclear Science Symposium Conference Record, 2006. IEEE, vol 6, p. 3339-3345. doi: 10.1109/NSSMIC.2006. 353719
-
(2006)
Nuclear Science Symposium Conference Record
, vol.6
, pp. 3339-3345
-
-
Tohka, J.1
Reilhac, A.2
-
19
-
-
33645302410
-
A multiresolution image based approach for correction of partial volume effects in emission tomography
-
16552110 10.1088/0031-9155/51/7/016 1:STN:280:DC%2BD287mtlCltQ%3D%3D
-
N Boussion M Hatt F Lamare Y Bizais A Turzo C Rest, et al. 2006 A multiresolution image based approach for correction of partial volume effects in emission tomography Phys Med Biol 51 1857 1876 16552110 10.1088/0031-9155/51/7/ 016 1:STN:280:DC%2BD287mtlCltQ%3D%3D
-
(2006)
Phys Med Biol
, vol.51
, pp. 1857-1876
-
-
Boussion, N.1
Hatt, M.2
Lamare, F.3
Bizais, Y.4
Turzo, A.5
Rest, C.6
-
20
-
-
67649232077
-
A 3D multi resolution local analysis approach for correction of partial volume effects in emission tomography
-
NSS' 08, IEEE doi: 10.1109/NSSMIC.2008.4774429
-
Le Pogam A, Boussion N, Hatt M, Turkheimer F, Prunier-Aesch C, Guilloteau D, et al. A 3D multi resolution local analysis approach for correction of partial volume effects in emission tomography. Nuclear Science Symposium Conference Record, 2008. NSS' 08, IEEE, p. 5300-5303. doi: 10.1109/NSSMIC.2008. 4774429
-
Nuclear Science Symposium Conference Record, 2008
, pp. 5300-5303
-
-
Le Pogam, A.1
Boussion, N.2
Hatt, M.3
Turkheimer, F.4
Prunier-Aesch, C.5
Guilloteau, D.6
-
21
-
-
56749131806
-
Functional and structural synergy for resolution recovery and partial volume correction in brain PET
-
18852055 10.1016/j.neuroimage.2008.09.012
-
M Shidahara C Tsoumpas A Hammers N Boussion D Visvikis T Suhara, et al. 2009 Functional and structural synergy for resolution recovery and partial volume correction in brain PET Neuroimage 44 340 348 18852055 10.1016/j.neuroimage.2008.09.012
-
(2009)
Neuroimage
, vol.44
, pp. 340-348
-
-
Shidahara, M.1
Tsoumpas, C.2
Hammers, A.3
Boussion, N.4
Visvikis, D.5
Suhara, T.6
-
22
-
-
33750579692
-
Improved quantitation for PET/CT image reconstruction with system modeling and anatomical priors
-
DOI 10.1118/1.2358198
-
AM Alessio PE Kinahan 2006 Improved quantitation for PET/CT image reconstruction with system modeling and anatomical priors Med Phys 33 4095 4103 17153389 10.1118/1.2358198 (Pubitemid 44679591)
-
(2006)
Medical Physics
, vol.33
, Issue.11
, pp. 4095-4103
-
-
Alessio, A.M.1
Kinahan, P.E.2
-
23
-
-
33947500461
-
Using deconvolution to improve PET spatial resolution in OSEM iterative reconstruction
-
G Rizzo I Castiglioni G Russo MG Tana F Dell'Acqua MC Gilardi, et al. 2007 Using deconvolution to improve PET spatial resolution in OSEM iterative reconstruction Method Inform Med 46 231 235 1:STN:280:DC%2BD2s7kslaqug%3D%3D (Pubitemid 46465495)
-
(2007)
Methods of Information in Medicine
, vol.46
, Issue.2
, pp. 231-235
-
-
Rizzo, G.1
Castiglioni, I.2
Russo, G.3
Tana, M.G.4
Dell'Acqua, F.5
Gilardi, M.C.6
Fazio, F.7
Cerutti, S.8
-
24
-
-
42649144446
-
Partial volume effect correction in PET using regularized iterative deconvolution with variance control based on local topology
-
DOI 10.1088/0031-9155/53/10/009, PII S0031915508616772
-
AS Kirov JZ Piao CR Schmidtlein 2008 Partial volume effect correction in PET using regularized iterative deconvolution with variance control based on local topology Phys Med Biol 53 2577 2591 18441414 10.1088/0031-9155/53/10/009 1:STN:280:DC%2BD1c3ovVWntw%3D%3D (Pubitemid 351595083)
-
(2008)
Physics in Medicine and Biology
, vol.53
, Issue.10
, pp. 2577-2591
-
-
Kirov, A.S.1
Piao, J.Z.2
Schmidtlein, C.R.3
-
25
-
-
0002965835
-
Pixel- versus region-based partial volume correction in PET
-
R.E. Carson M.E. Daube-Witherspoon P. Herscovitch (eds). Academic Press San Diego. 10.1016/B978-012161340-2/50012-3
-
Rousset OG, Ma Y, Wong DF, Evans AC. Pixel- versus region-based partial volume correction in PET. In: Carson RE, Daube-Witherspoon ME, Herscovitch P, editors. Quantitative functional brain imaging with positron emission tomography. San Diego: Academic Press; 1998. p. 67-75.
-
(1998)
Quantitative Functional Brain Imaging with Positron Emission Tomography
, pp. 67-75
-
-
Rousset, O.G.1
Ma, Y.2
Wong, D.F.3
Evans, A.C.4
-
26
-
-
1542504654
-
Integrated software for the analysis of brain PET/SPECT studies with partial-volume-effect correction
-
M Quarantelli K Berkouk A Prinster B Landeau C Svarer L Balkay, et al. 2004 Integrated software for the analysis of brain PET/SPECT studies with partial-volume-effect correction J Nucl Med 45 192 201 14960635 (Pubitemid 47618636)
-
(2004)
Journal of Nuclear Medicine
, vol.45
, Issue.2
, pp. 192-201
-
-
Quarantelli, M.1
Berkouk, K.2
Prinster, A.3
Landeau, B.4
Svarer, C.5
Balkay, L.6
Alfano, B.7
Brunetti, A.8
Baron, J.-C.9
Salvatore, M.10
-
27
-
-
0030353814
-
Investigation of partial volume correction methods for brain fdg pet studies
-
PII S0018949996089666
-
J Yang S Huang M Mega K Lin A Toga G Small, et al. 1996 Investigation of partial volume correction methods for brain FDG PET studies IEEE Trans Nucl Sci 43 3322 3327 10.1109/23.552745 (Pubitemid 126771004)
-
(1996)
IEEE Transactions on Nuclear Science
, vol.43
, Issue.6 PART 2
, pp. 3322-3327
-
-
Yang, J.1
Huang, S.C.2
Mega, M.3
Lin, K.P.4
-
28
-
-
77956191442
-
An improved method for voxel-based partial volume correction in PET and SPECT
-
10.1016/j.neuroimage.2006.04.072
-
K Erlandsson AT Wong R van Heertum JJ Mann RV Parsey 2006 An improved method for voxel-based partial volume correction in PET and SPECT Neuroimage 31 T84 10.1016/j.neuroimage.2006.04.072
-
(2006)
Neuroimage
, vol.31
, pp. 84
-
-
Erlandsson, K.1
Wong, A.T.2
Van Heertum, R.3
Mann, J.J.4
Parsey, R.V.5
-
29
-
-
18244406829
-
Whole brain segmentation: Automated labeling of neuroanatomical structures in the human brain
-
DOI 10.1016/S0896-6273(02)00569-X
-
B Fischl DH Salat E Busa M Albert M Dieterich C Haselgrove, et al. 2002 Whole brain segmentation: automated labeling of neuroanatomical structures in the human brain Neuron 33 341 355 11832223 10.1016/S0896-6273(02)00569-X 1:CAS:528:DC%2BD38XjtlWnsbg%3D (Pubitemid 34162530)
-
(2002)
Neuron
, vol.33
, Issue.3
, pp. 341-355
-
-
Fischl, B.1
Salat, D.H.2
Busa, E.3
Albert, M.4
Dieterich, M.5
Haselgrove, C.6
Van Der Kouwe, A.7
Killiany, R.8
Kennedy, D.9
Klaveness, S.10
Montillo, A.11
Makris, N.12
Rosen, B.13
Dale, A.M.14
-
30
-
-
9144254529
-
Automatically Parcellating the Human Cerebral Cortex
-
DOI 10.1093/cercor/bhg087
-
B Fischl A van der Kouwe C Destrieux E Halgren F Ségonne DH Salat, et al. 2004 Automatically parcellating the human cerebral cortex Cereb Cortex 14 11 22 14654453 10.1093/cercor/bhg087 (Pubitemid 38018050)
-
(2004)
Cerebral Cortex
, vol.14
, Issue.1
, pp. 11-22
-
-
Fischl, B.1
Van Der Kouwe, A.2
Destrieux, C.3
Halgren, E.4
Segonne, F.5
Salat, D.H.6
Busa, E.7
Seidman, L.J.8
Goldstein, J.9
Kennedy, D.10
Caviness, V.11
Makris, N.12
Rosen, B.13
Dale, A.M.14
-
31
-
-
0029013727
-
Staging of Alzheimer's disease-related neurofibrillary changes
-
7566337 10.1016/0197-4580(95)00021-6 1:STN:280:DyaK28%2FjsVynsg%3D%3D
-
H Braak E Braak 1995 Staging of Alzheimer's disease-related neurofibrillary changes Neurobiol Aging 16 271 278 7566337 10.1016/0197-4580(95) 00021-6 1:STN:280:DyaK28%2FjsVynsg%3D%3D
-
(1995)
Neurobiol Aging
, vol.16
, pp. 271-278
-
-
Braak, H.1
Braak, E.2
-
32
-
-
0035152169
-
Reconstructing a 3D structure from serial histological sections
-
DOI 10.1016/S0262-8856(00)00052-4
-
S Ourselin A Roche G Subsol X Pennec N Ayache 2001 Reconstructing a 3D structure from serial histological sections Image Vision Comput 19 25 31 10.1016/S0262-8856(00)00052-4 (Pubitemid 32033991)
-
(2001)
Image and Vision Computing
, vol.19
, Issue.1-2
, pp. 25-31
-
-
Ourselin, S.1
Roche, A.2
Subsol, G.3
Pennec, X.4
Ayache, N.5
-
33
-
-
58149295369
-
Regional analysis of FDG and PIB-PET images in normal aging, mild cognitive impairment, and Alzheimer's disease
-
18566819 10.1007/s00259-008-0833-y
-
Y Li JO Rinne L Mosconi E Pirraglia H Rusinek S DeSanti, et al. 2008 Regional analysis of FDG and PIB-PET images in normal aging, mild cognitive impairment, and Alzheimer's disease Eur J Nucl Med Mol Imaging 35 2169 2181 18566819 10.1007/s00259-008-0833-y
-
(2008)
Eur J Nucl Med Mol Imaging
, vol.35
, pp. 2169-2181
-
-
Li, Y.1
Rinne, J.O.2
Mosconi, L.3
Pirraglia, E.4
Rusinek, H.5
Desanti, S.6
-
34
-
-
67349149423
-
Incorporation of wavelet-based denoising in iterative deconvolution for partial volume correction in whole-body PET imaging
-
19224209 10.1007/s00259-009-1065-5 1:STN:280:DC%2BD1MzpsVWmtw%3D%3D
-
N Boussion C Cheze Le Rest M Hatt D Visvikis 2009 Incorporation of wavelet-based denoising in iterative deconvolution for partial volume correction in whole-body PET imaging Eur J Nucl Med Mol Imaging 36 1064 1075 19224209 10.1007/s00259-009-1065-5 1:STN:280:DC%2BD1MzpsVWmtw%3D%3D
-
(2009)
Eur J Nucl Med Mol Imaging
, vol.36
, pp. 1064-1075
-
-
Boussion, N.1
Cheze Le Rest, C.2
Hatt, M.3
Visvikis, D.4
-
35
-
-
66549122755
-
Differential FDDNP PET patterns in nondemented middle-aged and older adults
-
19390297 10.1097/JGP.0b013e318198750b
-
LM Ercoli P Siddarth V Kepe KJ Miller SC Huang GM Cole, et al. 2009 Differential FDDNP PET patterns in nondemented middle-aged and older adults Am J Geriatr Psychiatry 17 397 406 19390297 10.1097/JGP.0b013e318198750b
-
(2009)
Am J Geriatr Psychiatry
, vol.17
, pp. 397-406
-
-
Ercoli, L.M.1
Siddarth, P.2
Kepe, V.3
Miller, K.J.4
Huang, S.C.5
Cole, G.M.6
-
36
-
-
77955707891
-
Voxel-based analysis of Alzheimer's disease PET imaging using a triplet of radiotracers: PIB, FDDNP, and FDG
-
20385246 10.1016/j.neuroimage.2010.04.013
-
J Shin SY Lee SJ Kim SH Kim SJ Cho YB Kim 2010 Voxel-based analysis of Alzheimer's disease PET imaging using a triplet of radiotracers: PIB, FDDNP, and FDG Neuroimage 52 488 496 20385246 10.1016/j.neuroimage.2010.04.013
-
(2010)
Neuroimage
, vol.52
, pp. 488-496
-
-
Shin, J.1
Lee, S.Y.2
Kim, S.J.3
Kim, S.H.4
Cho, S.J.5
Kim, Y.B.6
-
37
-
-
0036898673
-
Correction of partial-volume effect for PET striatal imaging: Fast implementation and study of robustness
-
V Frouin C Comtat A Reilhac MC Gregoire 2002 Correction of partial-volume effect for PET striatal imaging: fast implementation and study of robustness J Nucl Med 43 1715 1726 12468524 (Pubitemid 35424999)
-
(2002)
Journal of Nuclear Medicine
, vol.43
, Issue.12
, pp. 1715-1726
-
-
Frouin, V.1
Comtat, C.2
Reilhac, A.3
Gregoire, M.-C.4
|