메뉴 건너뛰기




Volumn 22, Issue 27, 2011, Pages

Lead (II) ion detection in surface water with pM sensitivity using aza-crown-ether-modified silver nanoparticles via dynamic light scattering

Author keywords

[No Author keywords available]

Indexed keywords

COLORIMETRIC METHODS; DETECTION LIMITS; DETECTION SYSTEM; DRINKING WATER; ENVIRONMENTAL QUALITY STANDARDS; ENVIRONMENTAL WATER; HIGH SENSITIVITY; ION DETECTION; LAKE WATER SAMPLES; LEAD IONS; MAXIMUM CONTAMINATION LEVELS; SELECTIVITY AND SENSITIVITY; SILVER NANOPARTICLES; ULTRASENSITIVE; US ENVIRONMENTAL PROTECTION AGENCY;

EID: 79957856386     PISSN: 09574484     EISSN: 13616528     Source Type: Journal    