Volumn 180, Issue 4, 2008, Pages 310-317

Computer-assisted navigation system for interventional CT-guided procedures: Results of phantom and clinical studies;Computergestütztes navigationssystem für CT-gesteuerte interventionen: Ergebnisse am phantom und im klinischen einsatz

Author keywords

Biopsy; CT; CT guided intervention; Interventional procedures; Navigation system

Indexed keywords

ACCURACY; ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER PROGRAM; CONTROLLED STUDY; EYE TRACKING; HUMAN; HUMAN TISSUE; MAJOR CLINICAL STUDY; NEEDLE BIOPSY; PHANTOM; PRIORITY JOURNAL; ARTIFACT; BONE; COMPUTER ASSISTED SURGERY; DRUG EFFECT; EQUIPMENT DESIGN; ESOPHAGUS; IMAGE QUALITY; INSTRUMENTATION; LIVER; LOCAL ANESTHESIA; LUNG; NEOPLASM; PANCREAS; PATHOLOGY; REVIEW; SENSITIVITY AND SPECIFICITY; SPINAL ROOT; SPINE;

EID: 44849122287     PISSN: 14389029     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2008-1027139     Document Type: Article
Times cited : (34)

References (30)
  • 2
    • 34447634666 scopus 로고    scopus 로고
    • Computertomografisch gesteuerte Interventionen bei Kindern
    • Honnef D, Wildberger JE, Schubert H et al. Computertomografisch gesteuerte Interventionen bei Kindern. Fortschr Röntgenstr 2007; 179: 605-612
    • (2007) Fortschr Röntgenstr , vol.179 , pp. 605-612
    • Honnef, D.1    Wildberger, J.E.2    Schubert, H.3
  • 3
    • 18844416409 scopus 로고    scopus 로고
    • New suction guide needle designed to reduce the incidence of biopsy-related pneumothorax: Experimental evaluation in canine model
    • Morello Jr FA, Wright KC, Lembo TM. New suction guide needle designed to reduce the incidence of biopsy-related pneumothorax: experimental evaluation in canine model. Radiology 2005; 235: 1045-1049
    • (2005) Radiology , vol.235 , pp. 1045-1049
    • Morello Jr, F.A.1    Wright, K.C.2    Lembo, T.M.3
  • 4
    • 34248676817 scopus 로고    scopus 로고
    • CT-gesteuerte perkutane Gastrostomie: Technischer Erfolg, Früh- und Spä tkomplikationen.
    • Gottschalk A, Strotzer M, Feuerbach S et al. CT-gesteuerte perkutane Gastrostomie: Technischer Erfolg, Früh- und Spä tkomplikationen. Fortschr Röntgenstr 2007; 179: 387-395
    • (2007) Fortschr Röntgenstr , vol.179 , pp. 387-395
    • Gottschalk, A.1    Strotzer, M.2    Feuerbach, S.3
  • 5
    • 24744462730 scopus 로고    scopus 로고
    • MRT-gesteuerte Stanzbiopsie der Schulter: Möglichkeiten und Erfahrungen an einem vertikal offenen 0,5-T-System.
    • Thomas M, Schulz T, Schmidt F et al. MRT-gesteuerte Stanzbiopsie der Schulter: Möglichkeiten und Erfahrungen an einem vertikal offenen 0,5-T-System. Fortschr Röntgenstr 2005; 177: 1276-1283
    • (2005) Fortschr Röntgenstr , vol.177 , pp. 1276-1283
    • Thomas, M.1    Schulz, T.2    Schmidt, F.3
  • 6
    • 35148822696 scopus 로고    scopus 로고
    • MR-gesteuerte Schmerztherapie: Prinzipien und klinische Applikationen.
    • Fritz J, Pereira PL. MR-gesteuerte Schmerztherapie: Prinzipien und klinische Applikationen. Fortschr Röntgenstr 2007; 179: 914-924
    • (2007) Fortschr Röntgenstr , vol.179 , pp. 914-924
    • Fritz, J.1    Pereira, P.L.2
  • 7
    • 5444243831 scopus 로고    scopus 로고
    • Oblique approach of computed tomography guided needle biopsy using multiplanar reconstruction image by multidetector-row CT in lung cancer
    • Kimura T, Naka N, Minato Y et al. Oblique approach of computed tomography guided needle biopsy using multiplanar reconstruction image by multidetector-row CT in lung cancer. Europ Radiol 2004; 52: 206-211
    • (2004) Europ Radiol , vol.52 , pp. 206-211
    • Kimura, T.1    Naka, N.2    Minato, Y.3
  • 8
    • 0021925326 scopus 로고
    • A light-guidance system to be used for CT-guided biopsy
    • Frederick PR, Brown TH, Miller MH et al. A light-guidance system to be used for CT-guided biopsy. Radiology 1985; 154: 535-536
    • (1985) Radiology , vol.154 , pp. 535-536
    • Frederick, P.R.1    Brown, T.H.2    Miller, M.H.3
  • 9
    • 0025887030 scopus 로고    scopus 로고
    • Reuther G. A device for CT-guided needle punctures: technical note. Cardiovasc Intervent Radiology 1991; 14: 191-194
    • Reuther G. A device for CT-guided needle punctures: technical note. Cardiovasc Intervent Radiology 1991; 14: 191-194
  • 10
    • 0028303033 scopus 로고
    • A compact laser beam guidance system for interventional CT
    • Gangi A, Kastler B, Arhan JM et al. A compact laser beam guidance system for interventional CT. J Comput Assist Tomogr 1994; 18: 326-328
    • (1994) J Comput Assist Tomogr , vol.18 , pp. 326-328
    • Gangi, A.1    Kastler, B.2    Arhan, J.M.3
  • 11
    • 0028959064 scopus 로고
    • Laser guidance system for CT-guided punctures
    • Miaux Y, Guermazi A, Gossot D et al. Laser guidance system for CT-guided punctures. Radiology 1995; 194: 282-284
    • (1995) Radiology , vol.194 , pp. 282-284
    • Miaux, Y.1    Guermazi, A.2    Gossot, D.3
  • 12
    • 0342617551 scopus 로고    scopus 로고
    • CT-gesteuerte Intervention mittels Lasermarkierungs- und Zielhilfe.
    • Klöppel R, Wike W, Weiße T et al. CT-gesteuerte Intervention mittels Lasermarkierungs- und Zielhilfe. Fortschr Röntgenstr 1997; 167: 194-197
    • (1997) Fortschr Röntgenstr , vol.167 , pp. 194-197
    • Klöppel, R.1    Wike, W.2    Weiße, T.3
  • 13
    • 0032434805 scopus 로고    scopus 로고
    • Accuracy of CT biopsy; laser guidance versus conventional freehand techniques
    • Pereles FS, Baker M, Baldwin R et al. Accuracy of CT biopsy; laser guidance versus conventional freehand techniques. Academic Radiology 1998; 5: 766-770
    • (1998) Academic Radiology , vol.5 , pp. 766-770
    • Pereles, F.S.1    Baker, M.2    Baldwin, R.3
  • 14
    • 0032610649 scopus 로고    scopus 로고
    • Value of a laser guidance system for CT interventions: A phantom study
    • Jacobi V, Thalhammer A, Kirchner J. Value of a laser guidance system for CT interventions: a phantom study. Europ Radiol 1999; 9: 137-140
    • (1999) Europ Radiol , vol.9 , pp. 137-140
    • Jacobi, V.1    Thalhammer, A.2    Kirchner, J.3
  • 15
    • 0034203652 scopus 로고    scopus 로고
    • Accuracy testing of a new stereotactic CT-guided brian biopsy device in the dog
    • Moissonnier P, Bordeau W, Delisle F et al. Accuracy testing of a new stereotactic CT-guided brian biopsy device in the dog. Res Vet Sci 2000; 68: 243-247
    • (2000) Res Vet Sci , vol.68 , pp. 243-247
    • Moissonnier, P.1    Bordeau, W.2    Delisle, F.3
  • 16
    • 0025887030 scopus 로고    scopus 로고
    • A device for CT-guided needle punctures: Technical note
    • Reuther G. A device for CT-guided needle punctures: technical note. Cardiovasc Intervent Radiol 1991; 14: 191-194
    • (1991) Cardiovasc Intervent Radiol , vol.14 , pp. 191-194
    • Reuther, G.1
  • 17
    • 0031943101 scopus 로고    scopus 로고
    • Potentials of a new laser guidance system for percutaneous musculoskeletal procedures
    • Pereles FS, Ozgur HT, Lund PJ et al. Potentials of a new laser guidance system for percutaneous musculoskeletal procedures. Skeletal Radiol 1998; 27: 18-21
    • (1998) Skeletal Radiol , vol.27 , pp. 18-21
    • Pereles, F.S.1    Ozgur, H.T.2    Lund, P.J.3
  • 18
    • 0033924543 scopus 로고    scopus 로고
    • Erste Erfahrungen mit einem neuen optischen Zielsystem (SimpliCT) für CT-gesteuerte Punktionen.
    • Krombach GA, Schmitz-Rode T, Braband K et al. Erste Erfahrungen mit einem neuen optischen Zielsystem (SimpliCT) für CT-gesteuerte Punktionen. Fortschr Röntgenstr 2000; 172: 557-560
    • (2000) Fortschr Röntgenstr , vol.172 , pp. 557-560
    • Krombach, G.A.1    Schmitz-Rode, T.2    Braband, K.3
  • 19
    • 0034891288 scopus 로고    scopus 로고
    • Evaluation eines elektromagnetischen virtuellen Zielsystems (CT-Guide) für die Durchführung von CT-Interventionen.
    • Holzknecht N, Helmberger T, Schoepf UJ et al. Evaluation eines elektromagnetischen virtuellen Zielsystems (CT-Guide) für die Durchführung von CT-Interventionen. Fortschr Röntgenstr 2001; 173: 612-618
    • (2001) Fortschr Röntgenstr , vol.173 , pp. 612-618
    • Holzknecht, N.1    Helmberger, T.2    Schoepf, U.J.3
  • 20
    • 27744558712 scopus 로고    scopus 로고
    • Accuracy of biopsy needle navigation using the Medarpa system-computed tomography reality super-imposed on the site of intervention
    • Khan MF, Dogan S, Maataoui A et al. Accuracy of biopsy needle navigation using the Medarpa system-computed tomography reality super-imposed on the site of intervention. Eur Radiol 2005; 15: 2366-2374
    • (2005) Eur Radiol , vol.15 , pp. 2366-2374
    • Khan, M.F.1    Dogan, S.2    Maataoui, A.3
  • 21
    • 0032796748 scopus 로고    scopus 로고
    • Circular spirit level guidance system for CT- and MR-guided punctures
    • Bücker A, Schmitz-Rode T, Wein B et al. Circular spirit level guidance system for CT- and MR-guided punctures. Comput Assist Tomogr 1999; 23: 552-554
    • (1999) Comput Assist Tomogr , vol.23 , pp. 552-554
    • Bücker, A.1    Schmitz-Rode, T.2    Wein, B.3
  • 22
    • 0034037576 scopus 로고    scopus 로고
    • CT-gesteuerte Biopsien, Drainagen und perkutane Gastrostomien: Vergleich der Punktionssteuerung mit und ohne CT-Fluoroskopie.
    • Spies V, Butz B, Altjohann C et al. CT-gesteuerte Biopsien, Drainagen und perkutane Gastrostomien: Vergleich der Punktionssteuerung mit und ohne CT-Fluoroskopie. Fortschf Röntgenstr 2000; 172: 374-380
    • (2000) Fortschf Röntgenstr , vol.172 , pp. 374-380
    • Spies, V.1    Butz, B.2    Altjohann, C.3
  • 23
    • 0033277577 scopus 로고    scopus 로고
    • Personel exposure rates during simulated biopsies with a real-time CT scanner
    • Mellenberg DE, Sato Y, Thompson BH et al. Personel exposure rates during simulated biopsies with a real-time CT scanner. Acad Radiol 1999; 6: 687-690
    • (1999) Acad Radiol , vol.6 , pp. 687-690
    • Mellenberg, D.E.1    Sato, Y.2    Thompson, B.H.3
  • 24
    • 2542450780 scopus 로고    scopus 로고
    • Repositioning accuracy of a commercially available thermoplastic mask system
    • Fuss M, Salter BJ, Cheek D et al. Repositioning accuracy of a commercially available thermoplastic mask system. Radiother Oncol 2004; 71: 339-345
    • (2004) Radiother Oncol , vol.71 , pp. 339-345
    • Fuss, M.1    Salter, B.J.2    Cheek, D.3
  • 25
    • 0842285322 scopus 로고    scopus 로고
    • Reproducibility of patient positioning for fractionated extracranial stereotactic radiothetapy using a double-vacuum technique
    • Nevinny-Stickel M, Sweeney RA, Bale RJ et al. Reproducibility of patient positioning for fractionated extracranial stereotactic radiothetapy using a double-vacuum technique. Strahlenther Onkol 2004; 180: 117-122
    • (2004) Strahlenther Onkol , vol.180 , pp. 117-122
    • Nevinny-Stickel, M.1    Sweeney, R.A.2    Bale, R.J.3
  • 27
    • 26944452839 scopus 로고    scopus 로고
    • Möglicher Nutzen und Auswirkung einer Lipiodolmarkierung auf die Histologie beim hepatozellulären Karzinom.
    • Gerhards A, Mildenberger P, Herber S et al. Möglicher Nutzen und Auswirkung einer Lipiodolmarkierung auf die Histologie beim hepatozellulären Karzinom. Fortschr Röntgenstr 2005; 177: 1380-1386
    • (2005) Fortschr Röntgenstr , vol.177 , pp. 1380-1386
    • Gerhards, A.1    Mildenberger, P.2    Herber, S.3
  • 28
    • 34247605352 scopus 로고    scopus 로고
    • CT-guided intervention with low tadiation dose: Feasibility and experience
    • Lucey BC, Varghese JC, Hochberg A et al. CT-guided intervention with low tadiation dose: feasibility and experience. Am J Roentgenol 2007; 188: 1187-1194
    • (2007) Am J Roentgenol , vol.188 , pp. 1187-1194
    • Lucey, B.C.1    Varghese, J.C.2    Hochberg, A.3
  • 29
    • 0034037576 scopus 로고    scopus 로고
    • CT-gesteuette Biopsien, Drainagen und perkutane Gastrostomien: Vergleich der Punktionssteuerung mit und ohne CT-Fluoroskopie.
    • Spies V, Butz B, Altjohann C et al. CT-gesteuette Biopsien, Drainagen und perkutane Gastrostomien: Vergleich der Punktionssteuerung mit und ohne CT-Fluoroskopie. Fortscht Röntgenstr 2000; 172: 374-380
    • (2000) Fortscht Röntgenstr , vol.172 , pp. 374-380
    • Spies, V.1    Butz, B.2    Altjohann, C.3
  • 30
    • 33845421472 scopus 로고    scopus 로고
    • Reproducible Simulation of Respiratory Motion in Porcine Lung Explants
    • Biederer J, Plathow C, Schoebinger M et al. Reproducible Simulation of Respiratory Motion in Porcine Lung Explants. Fortschr Röntgenstr 2006; 178: 1067-1072
    • (2006) Fortschr Röntgenstr , vol.178 , pp. 1067-1072
    • Biederer, J.1    Plathow, C.2    Schoebinger, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.