메뉴 건너뛰기




Volumn 55, Issue 1, 2011, Pages 21-43

Quantitative imaging of 124I with PET/CT in pretherapy lesion dosimetry: Effects impairing image quantification and their corrections

Author keywords

Dosimetry; Image quantification; Iodine 124; Positron emission tomography; Radionuclide therapy

Indexed keywords

3 (IODOBENZYL)GUANIDINE I 124; FLUORINE 18; IODINE 123; IODINE 124; IODINE 131; SODIUM IODIDE I 124; SODIUM IODIDE I 131; UNCLASSIFIED DRUG;

EID: 79957511354     PISSN: 18244785     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (40)

References (99)
  • 1
    • 47749129217 scopus 로고    scopus 로고
    • State of the Art in Nuclear Medicine Dose Assessment
    • DOI 10.1053/j.semnuclmed.2008.05.005, PII S0001299808000731
    • Stabin MG, Brill AB. State of the art in nuclear medicine dose assessment. Semin Nucl Med 2008;38:308-20. (Pubitemid 352033563)
    • (2008) Seminars in Nuclear Medicine , vol.38 , Issue.5 , pp. 308-320
    • Stabin, M.G.1    Brill, A.B.2
  • 2
    • 46449110510 scopus 로고    scopus 로고
    • Update: The case for patient-specific dosimetry in radionuclide therapy
    • DOI 10.1089/cbr.2007.0445
    • Stabin MG. The case for patient-specific dosimetry in radionuclide therapy. Cancer Biother Radiopharm 2008;23:273-84. (Pubitemid 351931455)
    • (2008) Cancer Biotherapy and Radiopharmaceuticals , vol.23 , Issue.3 , pp. 273-284
    • Stabin, M.G.1
  • 3
    • 21344440300 scopus 로고    scopus 로고
    • Patient dosimetry in radionuclide therapy: The whys and the wherefores
    • DOI 10.1097/01.mnm.0000167910.76718.ad
    • Thierens HM, Monsieurs MA, Bacher K. Patient dosimetry in radionuclide therapy: the whys and the wherefores. Nucl Med Commun 2005;26:593-9. (Pubitemid 40910863)
    • (2005) Nuclear Medicine Communications , vol.26 , Issue.7 , pp. 593-599
    • Thierens, H.M.1    Monsieurs, M.A.2    Bacher, K.3
  • 7
    • 69549118507 scopus 로고    scopus 로고
    • SPECT imaging of high energy isotopes and isotopes with high energy contaminants with rotating slat collimators
    • Van Holen R, Staelens S, Vandenberghe S. SPECT imaging of high energy isotopes and isotopes with high energy contaminants with rotating slat collimators. Med Phys 2009;36:4257-67.
    • (2009) Med Phys , vol.36 , pp. 4257-4267
    • Van Holen, R.1    Staelens, S.2    Vandenberghe, S.3
  • 8
    • 53649107436 scopus 로고    scopus 로고
    • Hepatic absorbed radiation dosimetry during I-131 metaiodobenzylguanidine (MIBG) therapy for refractory neuroblastoma
    • Koral KF, Huberty JP, Frame B, Matthay KK, Maris JM, Regan D et al. Hepatic absorbed radiation dosimetry during I-131 metaiodobenzylguanidine (MIBG) therapy for refractory neuroblastoma. Eur J Nucl Med Mol Imaging 2008;35:2105-12.
    • (2008) Eur J Nucl Med Mol Imaging , vol.35 , pp. 2105-2112
    • Koral, K.F.1    Huberty, J.P.2    Frame, B.3    Matthay, K.K.4    Maris, J.M.5    Regan, D.6
  • 10
    • 0029745562 scopus 로고    scopus 로고
    • Imaging technologies for radionuclide dosimetry
    • DOI 10.1088/0031-9155/41/10/002
    • Ott RJ. Imaging technologies for radionuclide dosimetry. Phys Med Biol 1996;41:1885-94. (Pubitemid 26333628)
    • (1996) Physics in Medicine and Biology , vol.41 , Issue.10 , pp. 1885-1894
    • Ott, R.J.1
  • 12
    • 48149100934 scopus 로고    scopus 로고
    • Planar and SPECT imaging in the era of PET and PET-CT: Can it survive the test of time?
    • Alavi A, Basu S. Planar and SPECT imaging in the era of PET and PET-CT: can it survive the test of time? Eur J Nucl Med Mol Imaging 2008;35:1554-9.
    • (2008) Eur J Nucl Med Mol Imaging , vol.35 , pp. 1554-1559
    • Alavi, A.1    Basu, S.2
  • 14
    • 66149106325 scopus 로고    scopus 로고
    • Standards for PET image acquisition and quantitative data analysis
    • Boellaard R. Standards for PET image acquisition and quantitative data analysis. J Nucl Med 2009;50:11S-20S.
    • (2009) J Nucl Med , vol.50
    • Boellaard, R.1
  • 17
    • 36149026049 scopus 로고
    • Radioactive isotopes of iodine
    • Livingood JJ, Seaborg GT. Radioactive isotopes of iodine. Phys Rev 1938;54:775-82.
    • (1938) Phys Rev , vol.54 , pp. 775-782
    • Livingood, J.J.1    Seaborg, G.T.2
  • 18
    • 84965017797 scopus 로고
    • The choice of a radioactive isotope for treatment of carcinoma of the thyroid
    • Phillips AF. The choice of a radioactive isotope for treatment of carcinoma of the thyroid. Brit J Radiol 1957;30:247-53.
    • (1957) Brit J Radiol , vol.30 , pp. 247-253
    • Phillips, A.F.1
  • 19
    • 36149052640 scopus 로고
    • Theoretical comparison of iodine-124 and iodine-131 thyroid dosimetry
    • Matthews CM, Tucker BA. Theoretical comparison of iodine-124 and iodine-131 thyroid dosimetry. Phys Med Biol 1961;5:245-53.
    • (1961) Phys Med Biol , vol.5 , pp. 245-253
    • Matthews, C.M.1    Tucker, B.A.2
  • 21
    • 73649171373 scopus 로고
    • Comparison of iodine 124 and iodine 131 for thyroid ablation
    • Goolden AW, Fowler JF, Matthews CM. Comparison of iodine 124 and iodine 131 for thyroid ablation. Br J Radiol 1963;36:346-9.
    • (1963) Br J Radiol , vol.36 , pp. 346-349
    • Goolden, A.W.1    Fowler, J.F.2    Matthews, C.M.3
  • 22
    • 70449716892 scopus 로고    scopus 로고
    • Patient specific treatment planning for systemically administered radiopharmaceuticals using PET/CT and Monte Carlo simulation
    • Grudzinski JJ, Yoriyaz H, Deluca PM Jr, Weichert JP. Patient specific treatment planning for systemically administered radiopharmaceuticals using PET/CT and Monte Carlo simulation. Appl Radiat Isot 2010;68:59-65.
    • (2010) Appl Radiat Isot , vol.68 , pp. 59-65
    • Grudzinski, J.J.1    Yoriyaz, H.2    Deluca Jr., P.M.3    Weichert, J.P.4
  • 24
  • 25
    • 0023127437 scopus 로고
    • Measurement of radiation dose to the thyroid using positron emission tomography
    • Ott RJ, Batty V, Webb BS, Flower MA, Leach MO, Clack R et al. Measurement of radiation dose to the thyroid using positron emission tomography. Br J Radiol 1987;60:245-51. (Pubitemid 17029102)
    • (1987) British Journal of Radiology , vol.60 , Issue.711 , pp. 245-251
    • Ott, R.J.1    Batty, V.2    Webb, S.3
  • 27
    • 0024427384 scopus 로고
    • Radiation dose assessment in radioiodine therapy. 2. Practical implementation using quantitative scanning and PET, with initial results on thyroid carcinoma
    • Flower MA, Schlesinger T, Hinton PJ, Adam I, Masoomi AM, Elbelli MA et al. Radiation dose assessment in radioiodine therapy. 2. Practical implementation using quantitative scanning and PET, with initial results on thyroid carcinoma. Radiother Oncol 1989;15:345-57.
    • (1989) Radiother Oncol , vol.15 , pp. 345-357
    • Flower, M.A.1    Schlesinger, T.2    Hinton, P.J.3    Adam, I.4    Masoomi, A.M.5    Elbelli, M.A.6
  • 29
    • 0027421029 scopus 로고
    • Radiation dose assessment in radioiodine therapy. Dose-response relationships in differentiated thyroid carcinoma using quantitative scanning and PET
    • O'Connell ME, Flower MA, Hinton PJ, Harmer CL, McCready VR. Radiation dose assessment in radioiodine therapy. Dose-response relationships in differentiated thyroid carcinoma using quantitative scanning and PET. Radiother Oncol 1993;28:16-26.
    • (1993) Radiother Oncol , vol.28 , pp. 16-26
    • O'Connell, M.E.1    Flower, M.A.2    Hinton, P.J.3    Harmer, C.L.4    McCready, V.R.5
  • 31
    • 0025910754 scopus 로고
    • Quantitative imaging of I-124 using positron emission tomography with applications to radioimmunodiagnosis and radioimmunotherapy
    • Pentlow KS, Graham MC, Lambrecht RM, Cheung NK, Larson SM. Quantitative imaging of I-124 using positron emission tomography with applications to radioimmunodiagnosis and radioimmunotherapy. Med Phys 1991;18:357-66.
    • (1991) Med Phys , vol.18 , pp. 357-366
    • Pentlow, K.S.1    Graham, M.C.2    Lambrecht, R.M.3    Cheung, N.K.4    Larson, S.M.5
  • 33
    • 0026592062 scopus 로고
    • PET scanning of iodine-124-3F9 as an approach to tumour dosimetry during treatment planning for radioimmunotherapy in a child with neuroblastoma
    • Larson SM, Pentlow KS, Volkow ND, Wolf AP, Finn RD, Lambrecht RM et al. PET scanning of iodine-124-3F9 as an approach to tumour dosimetry during treatment planning for radioimmunotherapy in a child with neuroblastoma. J Nucl Med 1992;33:2020-3.
    • (1992) J Nucl Med , vol.33 , pp. 2020-2023
    • Larson, S.M.1    Pentlow, K.S.2    Volkow, N.D.3    Wolf, A.P.4    Finn, R.D.5    Lambrecht, R.M.6
  • 39
    • 4544236386 scopus 로고    scopus 로고
    • Patient-specific dosimetry for I-131 thyroid cancer therapy using I-124 PET and 3-dimensional-internal dosimetry (3D-ID) software
    • Sgouros G, Kolbert KS, Sheikh A, Pentlow KS, Mun EF, Barth A et al. Patient-specific dosimetry for I-131 thyroid cancer therapy using I-124 PET and 3-dimensional-internal dosimetry (3D-ID) software. J Nucl Med 2004;45:1366-7.
    • (2004) J Nucl Med , vol.45 , pp. 1366-1367
    • Sgouros, G.1    Kolbert, K.S.2    Sheikh, A.3    Pentlow, K.S.4    Mun, E.F.5    Barth, A.6
  • 40
    • 77950576566 scopus 로고    scopus 로고
    • Experimental investigation of factors affecting the absolute recovery coefficients in iodine-124 PET lesion imaging
    • Jentzen W. Experimental investigation of factors affecting the absolute recovery coefficients in iodine-124 PET lesion imaging. Phys Med Biol 2010;55:2365-98.
    • (2010) Phys Med Biol , vol.55 , pp. 2365-2398
    • Jentzen, W.1
  • 41
    • 77953027037 scopus 로고    scopus 로고
    • Radiochemical determination of nuclear data for theory and applications
    • Qaim SM. Radiochemical determination of nuclear data for theory and applications. J Radioanal Nucl Chem 2010;284:489-505.
    • (2010) J Radioanal Nucl Chem , vol.284 , pp. 489-505
    • Qaim, S.M.1
  • 47
    • 33646708965 scopus 로고    scopus 로고
    • Three-dimensional positron emission tomography imaging with 124I and 86Y
    • DOI 10.1097/01.mnm.0000199476.46525.2c, PII 0000623120060300000006
    • 86Y. Nucl Med Commun 2006;27:237-45. (Pubitemid 44391811)
    • (2006) Nuclear Medicine Communications , vol.27 , Issue.3 , pp. 237-245
    • Vandenberghe, S.1
  • 51
    • 67649158603 scopus 로고    scopus 로고
    • Correction technique for cascade gammas in 1-124 imaging on a fully-3D, time-of-flight PET Scanner
    • Surti S, Scheuermann R, Karp JS. Correction technique for cascade gammas in 1-124 imaging on a fully-3D, time-of-flight PET Scanner. IEEE Trans Nucl Sci 2009;56:653-60.
    • (2009) IEEE Trans Nucl Sci , vol.56 , pp. 653-660
    • Surti, S.1    Scheuermann, R.2    Karp, J.S.3
  • 52
    • 0003815030 scopus 로고
    • New York, NY: McGraw-Hill
    • Evans RD. The Atomic Nucleus. New York, NY: McGraw-Hill; 1972. p. 628.
    • (1972) The Atomic Nucleus , pp. 628
    • Evans, R.D.1
  • 53
    • 0002239816 scopus 로고    scopus 로고
    • Quantitative imaging of yttrium-86 with PET: The occurrence and correction of anomalous apparent activity in high density regions
    • Pentlow KS, Finn RD, Larson SM, Erdi YE, Beattie BJ, Humm JL. Quantitative imaging of yttrium-86 with PET: the occurrence and correction of anomalous apparent activity in high density regions. Clin Positron Imaging 2000;3:85-90.
    • (2000) Clin Positron Imaging , vol.3 , pp. 85-90
    • Pentlow, K.S.1    Finn, R.D.2    Larson, S.M.3    Erdi, Y.E.4    Beattie, B.J.5    Humm, J.L.6
  • 56
    • 0141743727 scopus 로고    scopus 로고
    • Quantitative imaging of bromine-76 and yttrium-86 with PET: A method for the removal of spurious activity introduced by cascade gamma rays
    • DOI 10.1118/1.1595599
    • Beattie BJ, Finn RD, Rowland DJ, Pentlow KS. Quantitative imaging of bromine-76 and yttrium-86 with PET: a method for the removal of spurious activity introduced by cascade gamma rays. Med Phys 2003;30:2410-23. (Pubitemid 37129747)
    • (2003) Medical Physics , vol.30 , Issue.9 , pp. 2410-2423
    • Beattie, B.J.1    Finn, R.D.2    Rowland, D.J.3    Pentlow, K.S.4
  • 64
    • 0034244929 scopus 로고    scopus 로고
    • New, faster, image-based scatter correction for 3D PET
    • Watson CC. New, faster, image-based scatter correction for 3D PET. IEEE Trans Nucl Sci 2000;47:1587-94.
    • (2000) IEEE Trans Nucl Sci , vol.47 , pp. 1587-1594
    • Watson, C.C.1
  • 65
    • 3242772275 scopus 로고    scopus 로고
    • Optimization of a fully 3D single scatter simulation algorithm for 3D PET
    • DOI 10.1088/0031-9155/49/12/008, PII S0031915504707988
    • Accorsi R, Adam LE, Werner ME, Karp JS. Optimization of a fully 3D single scatter simulation algorithm for 3D PET. Phys Med Biol 2004;49:2577-98. (Pubitemid 38967946)
    • (2004) Physics in Medicine and Biology , vol.49 , Issue.12 , pp. 2577-2598
    • Accorsi, R.1    Adam, L.-E.2    Werner, M.E.3    Karp, J.S.4
  • 67
    • 79957463097 scopus 로고    scopus 로고
    • A correction for cascade coincidences in 3D utilizing the delayed coincidence sinogram
    • Beattie BJ, Pentlow KS. A correction for cascade coincidences in 3D utilizing the delayed coincidence sinogram. J Nucl Med 2004;45:411P.
    • (2004) J Nucl Med , vol.45 , pp. 411
    • Beattie, B.J.1    Pentlow, K.S.2
  • 69
    • 0027302774 scopus 로고
    • Development of a method to measure kinetics of radiolabelled monoclonal antibody in human tumour with applications to microdosimetry: Positron emission tomography studies of iodine-124 labelled 3F8 monoclonal antibody in glioma
    • Daghighian F, Pentlow KS, Larson SM, Graham MC, DiResta GR, Yeh SD et al. Development of a method to measure kinetics of radiolabelled monoclonal antibody in human tumour with applications to microdosimetry: positron emission tomography studies of iodine-124 labelled 3F8 monoclonal antibody in glioma. Eur J Nucl Med 1993;20:402-9. (Pubitemid 23204615)
    • (1993) European Journal of Nuclear Medicine , vol.20 , Issue.5 , pp. 402-409
    • Daghighian, F.1    Pentlow, K.S.2    Larson, S.M.3    Graham, M.C.4    DiResta, G.R.5    Yeh, S.D.J.6    Macapinlac, H.7    Finn, R.D.8    Arbit, E.9    Cheung, N.-K.V.10
  • 73
    • 70350704832 scopus 로고    scopus 로고
    • 124I PET-based 3D-RD dosimetry for a pediatric thyroid cancer patient: Real-time treatment planning and methodologic comparison
    • 124I PET-based 3D-RD dosimetry for a pediatric thyroid cancer patient: real-time treatment planning and methodologic comparison. J Nucl Med 2009;50:844-7.
    • (2009) J Nucl Med , vol.50 , pp. 844-847
    • Hobbs, R.F.1    Wahl, R.L.2    Lodge, M.A.3    Javadi, M.S.4    Cho, S.Y.5    Chien, D.T.6
  • 75
    • 58149226255 scopus 로고    scopus 로고
    • Partial volume correction strategies in PET
    • Rousset O, Rahmim A, Alavi A, Zaidi H. Partial volume correction strategies in PET. PET Clin 2007;2:235-49.
    • (2007) PET Clin , vol.2 , pp. 235-249
    • Rousset, O.1    Rahmim, A.2    Alavi, A.3    Zaidi, H.4
  • 76
    • 34250315240 scopus 로고    scopus 로고
    • Partial-volume effect in PET tumor imaging
    • DOI 10.2967/jnumed.106.035774
    • Soret M, Bacharach SL, Buvat I. Partial-volume effect in PET tumour imaging. J Nucl Med 2007;48:932-45. (Pubitemid 46909922)
    • (2007) Journal of Nuclear Medicine , vol.48 , Issue.6 , pp. 932-945
    • Soret, M.1    Bacharach, S.L.2    Buvat, I.3
  • 77
    • 77958456514 scopus 로고    scopus 로고
    • PET-guided delineation of radiation therapy treatment volumes: A survey of image segmentation techniques
    • Zaidi H, El Naqa I. PET-guided delineation of radiation therapy treatment volumes: a survey of image segmentation techniques. Eur J Nucl Med Mol Imaging 2010;37:2165-87.
    • (2010) Eur J Nucl Med Mol Imaging , vol.37 , pp. 2165-2187
    • Zaidi, H.1    El Naqa, I.2
  • 81
    • 0033972633 scopus 로고    scopus 로고
    • Re-evaluation of absorbed fractions for photons and electrons in spheres of various sizes
    • Stabin MG, Konijnenberg MW. Re-evaluation of absorbed fractions for photons and electrons in spheres of various sizes. J Nucl Med 2000;41:149-60. (Pubitemid 30046697)
    • (2000) Journal of Nuclear Medicine , vol.41 , Issue.1 , pp. 149-160
    • Stabin, M.G.1    Konijnenberg, M.W.2
  • 83
    • 0018367149 scopus 로고
    • Quantitation in positron emission tomography: 1. Effect of object size
    • Hoffman EJ, Huang SC, Phelps ME. Quantitation in positron emission tomography: 1. Effect of object size. J Comput Assist Tomogr 1979;3:299-308.
    • (1979) J Comput Assist Tomogr , vol.3 , pp. 299-308
    • Hoffman, E.J.1    Huang, S.C.2    Phelps, M.E.3
  • 84
    • 0019357118 scopus 로고
    • Quantitation in positron emission computed tomography: 5. Physical-anatomical effects
    • Mazziotta JC, Phelps ME, Plummer D, Kuhl DE. Quantitation in positron emission computed tomography: 5. Physical-anatomical effects. J Comput Assist Tomogr 1981;5:734-43.
    • (1981) J Comput Assist Tomogr , vol.5 , pp. 734-743
    • Mazziotta, J.C.1    Phelps, M.E.2    Plummer, D.3    Kuhl, D.E.4
  • 85
    • 0021261066 scopus 로고
    • Analysis of emission tomographic scan data: Limitations imposed by resolution and background
    • Kessler RM, Ellis JT, Eden M. Analysis of emission tomographic scan data: limitations imposed by resolution and background. J Comput Assist Tomogr 1984;8:514-22. (Pubitemid 14122897)
    • (1984) Journal of Computer Assisted Tomography , vol.8 , Issue.3 , pp. 514-522
    • Kessler, R.M.1    Ellis Jr., J.R.2    Eden, M.3
  • 86
    • 0030000352 scopus 로고    scopus 로고
    • Single-photon emission tomographic quantification in spherical objects: Effects of object size and background
    • Zito F, Gilardi MC, Magnani P, Fazio F. Single-photon emission tomographic quantification in spherical objects: effects of object size and background. Eur J Nucl Med 1996;23:263-71.
    • (1996) Eur J Nucl Med , vol.23 , pp. 263-271
    • Zito, F.1    Gilardi, M.C.2    Magnani, P.3    Fazio, F.4
  • 87
    • 0034922457 scopus 로고    scopus 로고
    • Monte Carlo evaluation of object shape effects in iodine-131 SPET tumor activity quantification
    • DOI 10.1007/s002590100551
    • Dewaraja YK, Ljungberg M, Koral KF. Monte Carlo evaluation of object shape effects in iodine-131 SPET tumour activity quantification. Eur J Nucl Med 2001;28:900-6. (Pubitemid 32662553)
    • (2001) European Journal of Nuclear Medicine , vol.28 , Issue.7 , pp. 900-906
    • Dewaraja, Y.K.1    Ljungberg, M.2    Koral, K.F.3
  • 91
    • 0026173784 scopus 로고
    • Quantitation of the human basal ganglia with positron emission tomography: A phantom study of the effect of contrast and axial positioning
    • DOI 10.1109/42.79480
    • Bendriem B, Dewey SL, Schlyer DJ, Wolf AP, Volkow ND. Quantitation of the human basal ganglia with positron emission tomography: a phantom study of the effect of contrast and axial positioning. IEEE Trans Med Imaging 1991;10:216-22. (Pubitemid 21645546)
    • (1991) IEEE Transactions on Medical Imaging , vol.10 , Issue.2 , pp. 216-222
    • Bendriem, B.1    Dewey, S.L.2    Schlyer, D.J.3    Wolf, A.P.4    Volkow, N.D.5
  • 93
    • 22544455324 scopus 로고    scopus 로고
    • Effect of motion on tracer activity determination in CT attenuation corrected PET images: A lung phantom study
    • DOI 10.1118/1.1943809
    • Pevsner A, Nehmeh SA, Humm JL, Mageras GS, Erdi YE. Effect of motion on tracer activity determination in CT attenuation corrected PET images: a lung phantom study. Med Phys 2005;32:2358-62. (Pubitemid 41023196)
    • (2005) Medical Physics , vol.32 , Issue.7 , pp. 2358-2362
    • Pevsner, A.1    Nehmeh, S.A.2    Humm, J.L.3    Mageras, G.S.4    Erdi, Y.E.5
  • 94
    • 77951821429 scopus 로고    scopus 로고
    • PET imaging for the quantification of biologically heterogeneous tumours: Measuring the effect of relative position on image-based quantification of dose-painting targets
    • McCall KC, Barbee DL, Kissick MW, Jeraj R. PET imaging for the quantification of biologically heterogeneous tumours: measuring the effect of relative position on image-based quantification of dose-painting targets. Phys Med Biol 2010;55:2789-806.
    • (2010) Phys Med Biol , vol.55 , pp. 2789-2806
    • McCall, K.C.1    Barbee, D.L.2    Kissick, M.W.3    Jeraj, R.4
  • 95
    • 0019992105 scopus 로고
    • Quantitation in positron emission computed tomography: 6. Effect of nonuniform resolution
    • Hoffman EJ, Huang SC, Plummer D, Phelps ME. Quantitation in positron emission computed tomography: 6. Effect of nonuniform resolution. J Comput Assist Tomogr 1982;6:987-99.
    • (1982) J Comput Assist Tomogr , vol.6 , pp. 987-999
    • Hoffman, E.J.1    Huang, S.C.2    Plummer, D.3    Phelps, M.E.4
  • 96
    • 77950576211 scopus 로고    scopus 로고
    • Pre-therapeutic iodine-124 PET(/CT) dosimetry confirms low average absorbed doses per administered iodine-131 activity to the salivary glands in radioiodine therapy of differentiated thyroid cancer
    • Jentzen W, Hobbs RF, Stahl A, Knust J, Sgouros G, Bockisch A. Pre-therapeutic iodine-124 PET(/CT) dosimetry confirms low average absorbed doses per administered iodine-131 activity to the salivary glands in radioiodine therapy of differentiated thyroid cancer. Eur J Nucl Med Mol Imaging 2010;37:884-95.
    • (2010) Eur J Nucl Med Mol Imaging , vol.37 , pp. 884-895
    • Jentzen, W.1    Hobbs, R.F.2    Stahl, A.3    Knust, J.4    Sgouros, G.5    Bockisch, A.6
  • 97
    • 79957450349 scopus 로고    scopus 로고
    • Prätherapeutische Blutdosimetrie bei der Radiojodtherapie des differenzierten Schilddrüsenkarzinoms: Ist eine genaue Blutdosimetrie allein auf der Grundlage der Ganzkörper-Messung möglich?
    • Ruhlmann M, Bockisch A, Jentzen W. Prätherapeutische Blutdosimetrie bei der Radiojodtherapie des differenzierten Schilddrüsenkarzinoms: Ist eine genaue Blutdosimetrie allein auf der Grundlage der Ganzkörper-Messung möglich? 49. Jahrestagung der Deutschen Gesellschaft für Nuklearmedizin in Bregenz, 13.-16. April 2011.
    • 49. Jahrestagung der Deutschen Gesellschaft für Nuklearmedizin in Bregenz, 13.-16. April 2011
    • Ruhlmann, M.1    Bockisch, A.2    Jentzen, W.3
  • 98
    • 12744275403 scopus 로고    scopus 로고
    • Imaging of tracer amounts of I-124 in the presence of therapeutic amounts of I-131 with a standard PET scanner
    • Pentlow KS, Mawlawi O, Daghighian F, Finn RD, Humm JL, Larson SM. Imaging of tracer amounts of I-124 in the presence of therapeutic amounts of I-131 with a standard PET scanner. J Nucl Med 1998;39:51P.
    • (1998) J Nucl Med , vol.39 , pp. 51
    • Pentlow, K.S.1    Mawlawi, O.2    Daghighian, F.3    Finn, R.D.4    Humm, J.L.5    Larson, S.M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.