메뉴 건너뛰기




Volumn 22, Issue 3, 2007, Pages 423-430

Comparison of image quality of different iodine isotopes (I-123, I-124, and I-131)

Author keywords

Image quality; Iodine isotopes; Monte Carlo

Indexed keywords

IODINE 123; IODINE 124; IODINE 131; RADIOISOTOPE;

EID: 34447523801     PISSN: 10849785     EISSN: None     Source Type: Journal    
DOI: 10.1089/cbr.2006.323     Document Type: Conference Paper
Times cited : (55)

References (13)
  • 1
    • 0033623357 scopus 로고    scopus 로고
    • 131I tumor quantification in radioimmunotherapy using SPECT imaging with an ultra-high-energy collimator
    • 131I tumor quantification in radioimmunotherapy using SPECT imaging with an ultra-high-energy collimator. J Nucl Med 2000;41:1760.
    • (2000) J Nucl Med , vol.41 , pp. 1760
    • Dewaraja, Y.K.1    Ljungberg, M.2    Koral, K.F.3
  • 4
    • 34447562535 scopus 로고    scopus 로고
    • Significant septal penetration effects caused by impurities in cyclotron-produced thallium-201
    • Staelens S, de Wit T, Lemahieu I, et al. Significant septal penetration effects caused by impurities in cyclotron-produced thallium-201. J Nucl Med 2006;47:381.
    • (2006) J Nucl Med , vol.47 , pp. 381
    • Staelens, S.1    de Wit, T.2    Lemahieu, I.3
  • 5
    • 33645686359 scopus 로고    scopus 로고
    • Modeling of high-energy contamination in SPECT imaging using Monte Carlo simulation
    • Cot A, Jane E, Sempau J, et al. Modeling of high-energy contamination in SPECT imaging using Monte Carlo simulation. IEEE Transactions on Nuclear Science. 2006;53(11):198.
    • (2006) IEEE Transactions on Nuclear Science , vol.53 , Issue.11 , pp. 198
    • Cot, A.1    Jane, E.2    Sempau, J.3
  • 6
    • 0141447446 scopus 로고    scopus 로고
    • Monte Carlo simulations of a scintillation camera using GATE: Validation and application modelling
    • Staelens S, Strul D, Santin G, et al. Monte Carlo simulations of a scintillation camera using GATE: Validation and application modelling. Phys Med Biol 2003; 48(18):3021.
    • (2003) Phys Med Biol , vol.48 , Issue.18 , pp. 3021
    • Staelens, S.1    Strul, D.2    Santin, G.3
  • 7
    • 3242717954 scopus 로고    scopus 로고
    • Imaging characteristics of a 3-dimensional gso whole-body pet camera
    • Surti S, Karp JS. Imaging characteristics of a 3-dimensional gso whole-body pet camera. J Nucl Med 2004; 45(6):1040.
    • (2004) J Nucl Med , vol.45 , Issue.6 , pp. 1040
    • Surti, S.1    Karp, J.S.2
  • 8
    • 5744251917 scopus 로고    scopus 로고
    • GATE: A simulation toolkit for PET and SPECT
    • Jan S, Santin G, Strul D, et al. GATE: A simulation toolkit for PET and SPECT. Phys Med Biol 2004; 49(19):4543.
    • (2004) Phys Med Biol , vol.49 , Issue.19 , pp. 4543
    • Jan, S.1    Santin, G.2    Strul, D.3
  • 9
    • 33645284910 scopus 로고    scopus 로고
    • Validation of a Monte Carlo simulation of the Philips Allegro/GEMINI PET systems using GATE
    • Lamare F, Turzo A, Bizais Y, et al. Validation of a Monte Carlo simulation of the Philips Allegro/GEMINI PET systems using GATE. Phys Med Biol 2006;51(4): 943
    • (2006) Phys Med Biol , vol.51 , Issue.4 , pp. 943
    • Lamare, F.1    Turzo, A.2    Bizais, Y.3
  • 10
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction for emission tomography
    • Shepp LA, and Vardi Y. Maximum likelihood reconstruction for emission tomography. TMI 1982;1(2): 113.
    • (1982) TMI , vol.1 , Issue.2 , pp. 113
    • Shepp, L.A.1    Vardi, Y.2
  • 11
    • 0021327145 scopus 로고
    • EM reconstruction algorithms for emission and transmission tomography
    • Lange K, Carson R. EM reconstruction algorithms for emission and transmission tomography. J Comput Assist Tomogr 1984;8(2):306.
    • (1984) J Comput Assist Tomogr , vol.8 , Issue.2 , pp. 306
    • Lange, K.1    Carson, R.2
  • 12
    • 0026221904 scopus 로고
    • A practical method for position-dependent scatter correction in single-photon emission CT
    • Ogawa K, Harata Y, Ichihara T, et al. A practical method for position-dependent scatter correction in single-photon emission CT. IEEE Trans Med Imag 1991; 10(3):408.
    • (1991) IEEE Trans Med Imag , vol.10 , Issue.3 , pp. 408
    • Ogawa, K.1    Harata, Y.2    Ichihara, T.3
  • 13
    • 4544236386 scopus 로고    scopus 로고
    • 124I PET and 3-dimensional-internal dosimetry (3D-ID) software
    • 124I PET and 3-dimensional-internal dosimetry (3D-ID) software. J Nucl Med 2004; 45:1366.
    • (2004) J Nucl Med , vol.45 , pp. 1366
    • Sgouros, G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.