메뉴 건너뛰기




Volumn 155, Issue 1, 2011, Pages 145-153

A polymer lab chip sensor with microfabricated planar silver electrode for continuous and on-site heavy metal measurement

Author keywords

Lead (Pb(II)); On site measurement; Reusable polymer lab chip sensor; Silver electrode; Square wave anodic stripping voltammetry (SWASV)

Indexed keywords

BISMUTH ELECTRODE; CONCENTRATION RANGES; CORRELATION COEFFICIENT; DEPOSITION TIME; DYNAMIC RANGE; ENVIRONMENTAL MONITORING; HEAVY METAL POLLUTANTS; LIMIT OF DETECTION; MICROFABRICATED; MICROFLUIDIC CHANNEL; MICROVOLUMES; ON-SITE MEASUREMENT; PEAK POTENTIALS; QUASI-REFERENCE ELECTRODES; RELATIVE STANDARD DEVIATIONS; REUSABLE POLYMER LAB CHIP SENSOR; SAMPLE VOLUME; SENSOR CHIPS; SILVER ELECTRODE; SOIL PORE WATERS; SQUARE WAVE ANODIC STRIPPING VOLTAMMETRY; STANDARD DEVIATION; STANDARD SOLUTIONS; THREE ORDERS OF MAGNITUDE; WORKING ELECTRODE;

EID: 79956374127     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2010.11.039     Document Type: Article
Times cited : (61)

References (34)
  • 1
    • 16644396509 scopus 로고    scopus 로고
    • The removal of heavy metals in urban runoff by sorption on mulch
    • A. Jang, Y.W. Seo, and P.L. Bishop The removal of heavy metals in urban runoff by sorption on mulch Environ. Pollut. 133 2005 117 128
    • (2005) Environ. Pollut. , vol.133 , pp. 117-128
    • Jang, A.1    Seo, Y.W.2    Bishop, P.L.3
  • 2
    • 33751199335 scopus 로고    scopus 로고
    • Development and characterisation of disposable gold electrodes, and their use for lead (II) analysis
    • M.F.M. Noh, and I.E. Tothill Development and characterisation of disposable gold electrodes, and their use for lead (II) analysis Anal. Bioanal. Chem. 386 2006 2095 2106
    • (2006) Anal. Bioanal. Chem. , vol.386 , pp. 2095-2106
    • Noh, M.F.M.1    Tothill, I.E.2
  • 3
    • 49549109856 scopus 로고    scopus 로고
    • Environmentally friendly disposable sensors with microfabricated on-chip planar bismuth electrode for in situ heavy metal ions measurement
    • Z. Zou, A. Jang, E. MacKnight, P-M. Wu, J. Do, P.L. Bishop, and C.H. Ahn Environmentally friendly disposable sensors with microfabricated on-chip planar bismuth electrode for in situ heavy metal ions measurement Sens. Actuat. B Chem. 134 2008 18 24
    • (2008) Sens. Actuat. B Chem. , vol.134 , pp. 18-24
    • Zou, Z.1    Jang, A.2    MacKnight, E.3    Wu, P.-M.4    Do, J.5    Bishop, P.L.6    Ahn, C.H.7
  • 4
    • 0032724101 scopus 로고    scopus 로고
    • Stripping voltammetry for the determination of trace metal speciation and in-situ measurements of trace metal distributions in marine waters
    • DOI 10.1016/S0003-2670(99)00619-4, PII S0003267099006194
    • E.P. Achterberg, and C. Braungardt Stripping voltammetry for the determination of trace metal speciation and in-situ measurements of trace metal distributions in marine waters Anal. Chim. Acta 400 1999 381 397 (Pubitemid 29535408)
    • (1999) Analytica Chimica Acta , vol.400 , Issue.1-3 , pp. 381-397
    • Achterberg, E.P.1    Braungardt, C.2
  • 7
    • 0035838484 scopus 로고    scopus 로고
    • Voltammetric studies of lead at calixarene modified screen-printed carbon electrodes and its trace determination in water by stripping voltammetry
    • DOI 10.1016/S0925-4005(01)00778-X, PII S092540050100778X
    • K.C. Honeychurch, J.P. Hart, D.C. Cowell, and D.W.M. Arrigan Voltammetric studies of lead at calixarene modified screen-printed carbon electrodes and its trace determination in water by stripping voltammetry Sens. Actuat. B Chem. 77 2001 642 652 (Pubitemid 32605638)
    • (2001) Sensors and Actuators, B: Chemical , vol.77 , Issue.3 , pp. 642-652
    • Honeychurch, K.C.1    Hart, J.P.2    Cowell, D.C.3    Arrigan, D.W.M.4
  • 8
    • 33745727654 scopus 로고    scopus 로고
    • Determination of nanomolar concentrations of cadmium by anodic-stripping voltammetry at a carbon paste electrode modified with zirconium phosphated amorphous silica
    • E. Shams, and R. Torabi Determination of nanomolar concentrations of cadmium by anodic-stripping voltammetry at a carbon paste electrode modified with zirconium phosphated amorphous silica Sens. Actuat. B Chem. 117 2006 86 92
    • (2006) Sens. Actuat. B Chem. , vol.117 , pp. 86-92
    • Shams, E.1    Torabi, R.2
  • 9
    • 0033554759 scopus 로고    scopus 로고
    • Multi-element heavy metal ion sensors for aqueous solutions
    • DOI 10.1016/S0925-4005(99)00256-7
    • S.B. Saban, and R.B. Darling Multi-element heavy metal ion sensors for aqueous solutions Sens. Actuat. B Chem. 61 1999 128 137 (Pubitemid 30526198)
    • (1999) Sensors and Actuators, B: Chemical , vol.61 , Issue.1 , pp. 128-137
    • Saban, S.B.1    Darling, R.B.2
  • 10
    • 27744475743 scopus 로고    scopus 로고
    • Enhancement of the sensitivity of electrochemical stripping analysis by evaporative concentration using a super-hydrophobic surface
    • DOI 10.1016/j.stam.2005.06.017, PII S1468699605001191, 21st Century COE Program, University of Tsukuba Promotion of Interdisciplinary Materials Science for Novel Functions
    • I. Yanagimachi, N. Nashida, K. Iwasa, and H. Suzuki Detection of heavy-metal ions based on evaporative concentration using a super-hydrophobic surface Sci. Technol. Adv. Mater. 6 2005 671 677 (Pubitemid 41635770)
    • (2005) Science and Technology of Advanced Materials , vol.6 , Issue.6 , pp. 671-677
    • Yanagimachi, I.1    Nashida, N.2    Iwasa, K.3    Suzuki, H.4
  • 11
    • 33244469462 scopus 로고    scopus 로고
    • Gold-based screen-printed sensor for detection of trace lead
    • DOI 10.1016/j.snb.2005.05.028, PII S0925400505005502
    • S. Laschi, I. Palchetti, and M. Mascini Gold-based screen-printed sensor for detection of trace lead Sens. Actuat. B Chem. 114 2006 460 465 (Pubitemid 43276214)
    • (2006) Sensors and Actuators, B: Chemical , vol.114 , Issue.1 , pp. 460-465
    • Laschi, S.1    Palchetti, I.2    Mascini, M.3
  • 13
    • 0035885301 scopus 로고    scopus 로고
    • Screen-printed anodic stripping voltammetric sensor containing HgO for heavy metal analysis
    • DOI 10.1016/S0003-2670(01)01219-3, PII S0003267001012193
    • J.Y. Choi, K. Seo, S.R. Cho, J.R. Oh, S.H. Kahng, and J. Park Screen-printed anodic stripping voltammetric sensor containing HgO for heavy metal analysis Anal. Chim. Acta 443 2001 241 247 (Pubitemid 32786862)
    • (2001) Analytica Chimica Acta , vol.443 , Issue.2 , pp. 241-247
    • Choi, J.-Y.1    Seo, K.2    Cho, S.-R.3    Oh, J.-R.4    Kahng, S.-H.5    Park, J.6
  • 15
    • 7244228073 scopus 로고    scopus 로고
    • Gold and silver micro-wire electrodes for trace analysis metals
    • G. Billon, and C.M.G. van den Berg Gold and silver micro-wire electrodes for trace analysis metals Electroanalysis 16 2004 1583 1591
    • (2004) Electroanalysis , vol.16 , pp. 1583-1591
    • Billon, G.1    Van Den Berg, C.M.G.2
  • 16
    • 0034661524 scopus 로고    scopus 로고
    • Bismuth-coated carbon electrodes for anodic stripping voltammetry
    • DOI 10.1021/ac000108x
    • J. Wang, J. Lu, S.B. Hocevar, and P.A.M. Farias Bismuth-coated carbon electrodes for anodic stripping voltammetry Anal. Chem. 72 2000 3218 3222 (Pubitemid 30482494)
    • (2000) Analytical Chemistry , vol.72 , Issue.14 , pp. 3218-3222
    • Wang, J.1    Lu, J.2    Hocevar, S.B.3    Farias, P.A.M.4    Ogorevc, B.5
  • 17
    • 0242413850 scopus 로고    scopus 로고
    • A study of bismuth-film electrodes for the detection of trace metals by anodic stripping voltammetry and their application to the determination of Pb and Zn in tapwater and human hair
    • G. Kefala, A. Economou, A. Voulgaropoulos, and M. Sofoniou A study of bismuth-film electrodes for the detection of trace metals by anodic stripping voltammetry and their application to the determination of Pb and Zn in tapwater and human hair Talanta 61 2003 603 610
    • (2003) Talanta , vol.61 , pp. 603-610
    • Kefala, G.1    Economou, A.2    Voulgaropoulos, A.3    Sofoniou, M.4
  • 18
    • 3342995196 scopus 로고    scopus 로고
    • A study of pencil-lead bismuth-film electrodes for the determination of trace metals by anodic stripping voltammetry
    • DOI 10.1016/j.aca.2004.05.008, PII S0003267004005884
    • D. Demetriades, A. Economou, and A. Voulgaropoulos A study of pencil-lead bismuth-film electrodes for the determination of trace metals by anodic stripping voltammetry Anal. Chim. Acta 519 2004 167 172 (Pubitemid 38993662)
    • (2004) Analytica Chimica Acta , vol.519 , Issue.2 , pp. 167-172
    • Demetriades, D.1    Economou, A.2    Voulgaropoulos, A.3
  • 19
    • 16244395486 scopus 로고    scopus 로고
    • Bismuth-film electrodes: Recent developments and potentialities for electroanalysis
    • DOI 10.1016/j.trac.2004.11.006
    • A. Economou Bismuth-film electrodes: recent developments and potentialities for electroanalysis Trends Anal. Chem. 24 2005 334 340 (Pubitemid 40461033)
    • (2005) TrAC - Trends in Analytical Chemistry , vol.24 , Issue.4 , pp. 334-340
    • Economou, A.1
  • 21
    • 34548536321 scopus 로고    scopus 로고
    • Anodic stripping voltammetry at a new type of disposable bismuth-plated carbon paste mini-electrodes
    • DOI 10.1016/j.aca.2007.07.067, PII S0003267007012548
    • L. Baldrianova, I. Svancara, and S. Sotiropoulos Anodic stripping voltammetry at a new type of disposable bismuth-plated carbon paste mini-electrodes Anal. Chim. Acta 599 2007 249 255 (Pubitemid 47384676)
    • (2007) Analytica Chimica Acta , vol.599 , Issue.2 , pp. 249-255
    • Baldrianova, L.1    Svancara, I.2    Sotiropoulos, S.3
  • 22
    • 13944253200 scopus 로고    scopus 로고
    • Determination of trace metals by underpotential deposition-stripping voltammetry at solid electrodes
    • DOI 10.1016/j.trac.2004.11.014, PII S0165993605000087
    • G. Herzog, and D.W.M. Arrigan Determination of trace metals by underpotential deposition-stripping voltammetry at solid electrodes Trends Anal. Chem. 24 2005 208 217 (Pubitemid 40270860)
    • (2005) TrAC - Trends in Analytical Chemistry , vol.24 , Issue.3 SPEC. ISS. , pp. 208-217
    • Herzog, G.1    Arrigan, D.W.M.2
  • 23
    • 23644454053 scopus 로고    scopus 로고
    • Analysis at bismuth electrodes: A review
    • J. Wang, and Stripping Analysis at bismuth electrodes: a review Electroanalysis 17 2005 1341 1346
    • (2005) Electroanalysis , vol.17 , pp. 1341-1346
    • Wang, J.1    Stripping2
  • 25
    • 0033067383 scopus 로고    scopus 로고
    • Determination of sub-nanomolar concentrations of lead by anodic-stripping voltammetry at the silver electrode
    • DOI 10.1016/S0003-2670(98)00663-1, PII S0003267098006631
    • E. Kirowa-Eisner, M. Brand, and D. Tzur Determination of sub-nanomolar concentrations of lead by anodic-stripping voltammetry at the silver electrode Anal. Chim. Acta 385 1999 325 335 (Pubitemid 29131558)
    • (1999) Analytica Chimica Acta , vol.385 , Issue.1-3 , pp. 325-335
    • Kirowa-Eisner, E.1    Brand, M.2    Tzur, D.3
  • 26
    • 0037156304 scopus 로고    scopus 로고
    • Determination of nanomolar concentrations of lead and cadmium by anodic-stripping voltammetry at the silver electrode
    • DOI 10.1016/S0003-2670(02)00016-8, PII S0003267002000168
    • Y. Bonfil, and E. Kirowa-Eisner Determination of nanomolar concentrations of lead and cadmium by anodic-stripping voltammetry at the silver electrode Anal. Chim. Acta 457 2002 285 296 (Pubitemid 34266938)
    • (2002) Analytica Chimica Acta , vol.457 , Issue.2 , pp. 285-296
    • Bonfil, Y.1    Kirowa-Eisner, E.2
  • 27
    • 0037194233 scopus 로고    scopus 로고
    • Characteristics of subtractive anodic stripping voltammetry of Pb and Cd at silver and gold electrodes
    • DOI 10.1016/S0003-2670(02)00489-0, PII S0003267002004890
    • Y. Bonfil, M. Brand, and E. Kirowa-Eisner Characteristics of subtractive anodic stripping voltammetry of Pb and Cd at silver and gold electrodes Anal. Chim. Acta 464 2002 99 114 (Pubitemid 34756545)
    • (2002) Analytica Chimica Acta , vol.464 , Issue.1 , pp. 99-114
    • Bonfil, Y.1    Brand, M.2    Kirowa-Eisner, E.3
  • 28
    • 37549059507 scopus 로고    scopus 로고
    • The renovated silver ring electrode
    • DOI 10.1016/j.elecom.2007.10.024, PII S1388248107004171
    • B. Bas The renovated silver ring electrode Electrochem. Commun. 10 2008 156 160 (Pubitemid 50015636)
    • (2008) Electrochemistry Communications , vol.10 , Issue.1 , pp. 156-160
    • Bas, B.1
  • 29
    • 72149121573 scopus 로고    scopus 로고
    • Novel renovated silver ring electrode for anodic stripping analysis of Pb(II) and Cd(II) traces in water samples without removal of oxygen and surfactants
    • B. Bas, M. Jakubowska, M. Jez, and F. Ciepiela Novel renovated silver ring electrode for anodic stripping analysis of Pb(II) and Cd(II) traces in water samples without removal of oxygen and surfactants J. Electroanal. Chem. 638 2010 3 8
    • (2010) J. Electroanal. Chem. , vol.638 , pp. 3-8
    • Bas, B.1    Jakubowska, M.2    Jez, M.3    Ciepiela, F.4
  • 30
    • 0025207507 scopus 로고
    • Miniaturized total chemical analysis systems. A novel concept for chemical sensing
    • A. Manz, N. Graber, and H.M. Widmer Miniaturized total chemical analysis systems: a novel concept for chemical sensing Sens. Actuat. B: Chem. 1 1990 244 248 (Pubitemid 20699475)
    • (1990) Sensors and Actuators, B: Chemical , vol.B1 , Issue.1-6 , pp. 244-248
    • Manz, A.1    Graber, N.2    Widmer, H.M.3
  • 31
    • 34247565074 scopus 로고    scopus 로고
    • Microfluidic system with electrochemical and optical detection
    • DOI 10.1016/j.mee.2007.01.248, PII S0167931707002626, Proceedings of the 32nd International Conference on Micro- and Nano-Engineering
    • I. Grabowska, M. Sajnoga, M. Juchniewicz, M. Chudy, A. Dybko, and Z. Brzozka Microfluidic system with electrochemical and optical detection Microelectron. Eng. 84 2007 1741 1743 (Pubitemid 46678470)
    • (2007) Microelectronic Engineering , vol.84 , Issue.5-8 , pp. 1741-1743
    • Grabowska, I.1    Sajnoga, M.2    Juchniewicz, M.3    Chudy, M.4    Dybko, A.5    Brzozka, Z.6
  • 32
    • 2342660255 scopus 로고    scopus 로고
    • Disposable smart lab on a chip for point-of-care clinical diagnostics
    • DOI 10.1109/JPROC.2003.820548, Biomedical Applications for Mems and Microfluidics
    • C.H. Ahn, J.W. Choi, G. Beaucage, J.H. Nevin, J.B. Lee, A. Puntambekar, and J.Y. Lee Disposable smart lab on a chip for point-of-care clinical diagnostics Proc. IEEE 92 2004 154 173 (Pubitemid 40890777)
    • (2004) Proceedings of the IEEE , vol.92 , Issue.1 , pp. 154-173
    • Ahn, C.H.1    Choi, J.-W.2    Beaucage, G.3    Nevin, J.H.4    Lee, J.-B.5    Puntambekar, A.6    Lee, J.Y.7
  • 33
    • 85008060994 scopus 로고    scopus 로고
    • An on-site heavy metal analyzer with polymer lab-on-a-chips for continuous sampling and monitoring
    • Z. Zou, A. Jang, E.T. MacKnight, P-M. Wu, J. Do, J.S. Shim, P.L. Bishop, and C.H. Ahn An on-site heavy metal analyzer with polymer lab-on-a-chips for continuous sampling and monitoring IEEE Sens. J. 9 2009 586 594
    • (2009) IEEE Sens. J. , vol.9 , pp. 586-594
    • Zou, Z.1    Jang, A.2    MacKnight, E.T.3    Wu, P.-M.4    Do, J.5    Shim, J.S.6    Bishop, P.L.7    Ahn, C.H.8
  • 34
    • 70349920767 scopus 로고    scopus 로고
    • A rapid prototyping method for polymer microfluidics with fixed aspect ratio and 3D tapered channels
    • A.W. Browne, M.J. Rust, W. Jung, S.H. Lee, and C.H. Ahn A rapid prototyping method for polymer microfluidics with fixed aspect ratio and 3D tapered channels Lab. Chip 9 2009 2941 2946
    • (2009) Lab. Chip , vol.9 , pp. 2941-2946
    • Browne, A.W.1    Rust, M.J.2    Jung, W.3    Lee, S.H.4    Ahn, C.H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.