메뉴 건너뛰기




Volumn 58, Issue 6, 2011, Pages 1846-1854

Wireless implantable electronic platform for chronic fluorescent-based biosensors

Author keywords

Biotelemetry; calcium sensing; chronic implants; fluorescence resonant energy transfer (FRET); fluorescence based biosensor; glucose monitoring; implantable devices

Indexed keywords

CHRONIC IMPLANTS; FLUORESCENCE RESONANT ENERGY TRANSFER (FRET); FLUORESCENCE-BASED BIOSENSOR; GLUCOSE MONITORING; IMPLANTABLE DEVICES;

EID: 79956358660     PISSN: 00189294     EISSN: 15582531     Source Type: Journal    
DOI: 10.1109/TBME.2011.2123098     Document Type: Article
Times cited : (38)

References (30)
  • 1
    • 68949178835 scopus 로고    scopus 로고
    • Securing wireless implantable devices for healthcare: Ideas and challenges
    • Jul.
    • K. Malasri and L. Wang, "Securing wireless implantable devices for healthcare: Ideas and challenges," IEEE Commun. Mag., vol. 47, no. 7, pp. 74-80, Jul. 2009.
    • (2009) IEEE Commun. Mag. , vol.47 , Issue.7 , pp. 74-80
    • Malasri, K.1    Wang, L.2
  • 2
    • 66249135995 scopus 로고    scopus 로고
    • Wireless contact lens sensor for intraocular pressure monitoring: Assessment on enucleated pig eyes
    • M. Leonardi, E. M. Pitchon, A. Bertsch, P. Renaud, and A. Mermoud, "Wireless contact lens sensor for intraocular pressure monitoring: Assessment on enucleated pig eyes," Acta Ophthalmologica, vol. 87, no. 4, pp. 433-437, 2009.
    • (2009) Acta Ophthalmologica , vol.87 , Issue.4 , pp. 433-437
    • Leonardi, M.1    Pitchon, E.M.2    Bertsch, A.3    Renaud, P.4    Mermoud, A.5
  • 3
    • 77952576025 scopus 로고    scopus 로고
    • Fully wireless implantable cardiovascular pressure monitor integrated with a medical stent
    • Jun.
    • E. Y. Chow, A. L. Chlebowski, S. Chakraborty, W. J. Chappell, and P. P. Irazoqui, "Fully wireless implantable cardiovascular pressure monitor integrated with a medical stent," IEEE Trans. Bio.-Med. Eng., vol. 57, no. 6, pp. 1487-1496, Jun. 2010.
    • (2010) IEEE Trans. Bio.-Med. Eng. , vol.57 , Issue.6 , pp. 1487-1496
    • Chow, E.Y.1    Chlebowski, A.L.2    Chakraborty, S.3    Chappell, W.J.4    Irazoqui, P.P.5
  • 8
    • 18044393862 scopus 로고    scopus 로고
    • Evanescent wave fluorescence biosensors
    • DOI 10.1016/j.bios.2004.10.026, 20th Anniversary of Biosendors and Bioelectronics
    • C. R. Taitt, G. P. Anderson, and F. S. Ligler, "Evanescent wave fluorescence biosensors," Biosens. Bioelectron., vol. 20, no. 12, pp. 2470-2487, 2005. (Pubitemid 40602184)
    • (2005) Biosensors and Bioelectronics , vol.20 , Issue.12 , pp. 2470-2487
    • Taitt, C.R.1    Anderson, G.P.2    Ligler, F.S.3
  • 9
    • 63749111006 scopus 로고    scopus 로고
    • Micro-and nanobiosensors\state of the art and trends
    • G. A. Urban, "Micro-and nanobiosensors\state of the art and trends," Meas. Sci. Technol., vol. 20, no. 1, p. 012001, 2009.
    • (2009) Meas. Sci. Technol. , vol.20 , Issue.1 , pp. 012001
    • Urban, G.A.1
  • 10
    • 2342466734 scopus 로고    scopus 로고
    • Global prevalence of diabetes
    • May
    • S. Wild, G. Roglic, A. Green, R. Sicree, and H. King, "Global prevalence of diabetes," Diabetes Care, vol. 27, no. 5, pp. 1047-1053, May 2004.
    • (2004) Diabetes Care , vol.27 , Issue.5 , pp. 1047-1053
    • Wild, S.1    Roglic, G.2    Green, A.3    Sicree, R.4    King, H.5
  • 11
    • 13244255587 scopus 로고    scopus 로고
    • Towards a miniature implantable in vivo telemetry monitoring system dynamically configurable as a potentiostat or galvanostat for two- and three-electrode biosensors
    • DOI 10.1109/TIM.2004.839757
    • R. D. Beach, R. W. Conlan, M. C. Godwin, and F. Moussy, "Towards a miniature implantable in vivo telemetry monitoring system dynamically configurable as a potentiostat or galvanostat for two-and three-electrode biosensors," IEEE Trans. Instrum. Meas., vol. 54, no. 1, pp. 61-72, Feb. 2005. (Pubitemid 40181637)
    • (2005) IEEE Transactions on Instrumentation and Measurement , vol.54 , Issue.1 , pp. 61-72
    • Beach, R.D.1    Conlan, R.W.2    Godwin, M.C.3    Moussy, F.4
  • 12
    • 77955091787 scopus 로고    scopus 로고
    • A wireless-implantable microsystem for continuous blood glucose monitoring
    • Jun.
    • M. M. Ahmadi and G. A. Jullien, "A wireless-implantable microsystem for continuous blood glucose monitoring," IEEE Trans. Biomed. Circ. Sys., vol. 3, no. 3, pp. 169-180, Jun. 2009.
    • (2009) IEEE Trans. Biomed. Circ. Sys. , vol.3 , Issue.3 , pp. 169-180
    • Ahmadi, M.M.1    Jullien, G.A.2
  • 14
    • 18044373272 scopus 로고    scopus 로고
    • Fluorescence-based glucose sensors
    • DOI 10.1016/j.bios.2004.10.002, 20th Anniversary of Biosendors and Bioelectronics
    • J. C. Pickup, F. Hussain, N. D. Evans, O. J. Rolinski, and D. J. Birch, "Fluorescence-based glucose sensors," Biosens. Bioelectron., vol. 20, no. 12, pp. 2555-2565, 2005. (Pubitemid 40602188)
    • (2005) Biosensors and Bioelectronics , vol.20 , Issue.12 , pp. 2555-2565
    • Pickup, J.C.1    Hussain, F.2    Evans, N.D.3    Rolinski, O.J.4    Birch, D.J.S.5
  • 15
    • 53849112654 scopus 로고    scopus 로고
    • A new nanobiosensor for glucose with high sensitivity and selectivity in serum based on fluorescence resonance energy transfer (FRET) between CdTe quantum dots and Au nanoparticles
    • B. Tang, L. Cao, K. Xu, L. Zhuo, J. Ge, Q. Li, and L. Yu, "A new nanobiosensor for glucose with high sensitivity and selectivity in serum based on fluorescence resonance energy transfer (FRET) between CdTe quantum dots and Au nanoparticles," Chem.\Eur. J., vol. 14, no. 12, pp. 3637-3644, 2008.
    • (2008) Chem.\Eur. J. , vol.14 , Issue.12 , pp. 3637-3644
    • Tang, B.1    Cao, L.2    Xu, K.3    Zhuo, L.4    Ge, J.5    Li, Q.6    Yu, L.7
  • 16
    • 36049012688 scopus 로고    scopus 로고
    • Fluorescence-based sensing of glucose using engineered glucose/galactose-binding protein: A comparison of fluorescence resonance energy transfer and environmentally sensitive dye labelling strategies
    • DOI 10.1016/j.bbrc.2007.10.129, PII S0006291X07023091
    • F. Khan, L. Gnudi, and J. C. Pickup, "Fluorescence-based sensing of glucose using engineered glucose/galactose-binding protein: A comparison of fluorescence resonance energy transfer and environmentally sensitive dye labelling strategies," Biochem. Biophys. Res. Commun., vol. 365, no. 1, pp. 102-106, 2008. (Pubitemid 350102458)
    • (2008) Biochemical and Biophysical Research Communications , vol.365 , Issue.1 , pp. 102-106
    • Khan, F.1    Gnudi, L.2    Pickup, J.C.3
  • 18
    • 33748423435 scopus 로고    scopus 로고
    • In vivo performance evaluation of a transdermal near-infrared fluorescence resonance energy transfer affinity sensor for continuous glucose monitoring
    • DOI 10.1089/dia.2006.8.296
    • R. Ballerstadt, C. Evans, A. Gowda, and R. McNichols, "In vivo performance evaluation of a transdermal near-infrared fluorescence resonance energy transfer affinity sensor for continuous glucose monitoring," Diabetes Technol. Therapeut., vol. 8, no. 3, pp. 296-311, 2006. (Pubitemid 46100524)
    • (2006) Diabetes Technology and Therapeutics , vol.8 , Issue.3 , pp. 296-311
    • Ballerstadt, R.1    Evans, C.2    Gowda, A.3    McNichols, R.4
  • 19
    • 78149256521 scopus 로고    scopus 로고
    • Injectable hydrogel microbeads for fluorescence-based in vivo continuous glucose monitoring
    • H. Shibata, Y. J. Heo, T. Okitsu, Y. Matsunaga, T. Kawanishi, and S. Takeuchi, "Injectable hydrogel microbeads for fluorescence-based in vivo continuous glucose monitoring," Proc. Nat. Acad. Sci. USA, vol. 107, no. 42, pp. 17 894-17 898, 2010.
    • (2010) Proc. Nat. Acad. Sci. USA , vol.107 , Issue.42 , pp. 17894-17898
    • Shibata, H.1    Heo, Y.J.2    Okitsu, T.3    Matsunaga, Y.4    Kawanishi, T.5    Takeuchi, S.6
  • 20
    • 77956812222 scopus 로고    scopus 로고
    • Glucose response of dissolved-core alginate microspheres: Towards a continuous glucose biosensor
    • A. Chaudhary, M. McShane, and R. Srivastava, "Glucose response of dissolved-core alginate microspheres: Towards a continuous glucose biosensor," Analyst, vol. 135, no. 10, pp. 2620-2628, 2010.
    • (2010) Analyst , vol.135 , Issue.10 , pp. 2620-2628
    • Chaudhary, A.1    McShane, M.2    Srivastava, R.3
  • 22
    • 84981779372 scopus 로고
    • Zwischenmolekulare Energiewanderung und Fluoreszenz
    • T. Förster, "Zwischenmolekulare Energiewanderung und Fluoreszenz," Annalen der Physik, vol. 437, no. 1-2, pp. 55-75, 1948.
    • (1948) Annalen der Physik , vol.437 , Issue.1-2 , pp. 55-75
    • Förster, T.1
  • 23
    • 0343375204 scopus 로고    scopus 로고
    • Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz)
    • ICNIRP Guidelines Apr.
    • ICNIRP Guidelines, "Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz)," Health Phys., vol. 74, pp. 494-522, Apr. 1998
    • (1998) Health Phys. , vol.74 , pp. 494-522
  • 25
    • 38849152825 scopus 로고    scopus 로고
    • An implantable ZigBee ready telemetric platform for in vivo monitoring of physiological parameters
    • DOI 10.1016/j.sna.2007.04.035, PII S0924424707003159
    • P. Valdastri, S. Rossi, A. Menciassi, V. Lionetti, F. Bernini, F. Recchia, and P. Dario, "An implantable zigbee ready telemetric platform for in vivo monitoring of physiological parameters," Sens. Actuat., A: Phys., vol. 142, no. 1, pp. 369-378, 2008. (Pubitemid 351199581)
    • (2008) Sensors and Actuators, A: Physical , vol.142 , Issue.1 , pp. 369-378
    • Valdastri, P.1    Rossi, S.2    Menciassi, A.3    Lionetti, V.4    Bernini, F.5    Recchia, F.A.6    Dario, P.7
  • 26
    • 44349105367 scopus 로고    scopus 로고
    • Transmission power requirements for novel ZigBee implants in the gastrointestinal tract
    • DOI 10.1109/TBME.2008.919117, 10
    • P. Valdastri, A. Menciassi, and P. Dario, "Transmission power requirements for novel zigbee implants in the gastrointestinal tract," IEEE Trans. Biomed. Eng., vol. 55, no. 6, pp. 1705-1710, Jun. 2008. (Pubitemid 351728021)
    • (2008) IEEE Transactions on Biomedical Engineering , vol.55 , Issue.6 , pp. 1705-1710
    • Valdastri, P.1    Menciassi, A.2    Dario, P.3
  • 27
    • 79956366139 scopus 로고    scopus 로고
    • ZigBee Alliance [Online] Available
    • ZigBee Alliance. (2009).The ZigBee alliance website [Online]. Available: http://www.zigbee.org
    • (2009) The ZigBee Alliance Website
  • 29
    • 0242501562 scopus 로고    scopus 로고
    • Genetic engineering of an allosterically based glucose indicator protein for continuous glucose monitoring by fluorescence resonance energy transfer
    • DOI 10.1021/ac034022q
    • K. Ye and J. S. Schultz, "Genetic engineering of an allosterically based glucose indicator protein for continuous glucose monitoring by fluorescence resonance energy transfer," Anal. Chem., vol. 75, pp. 3451-3459, 2003. (Pubitemid 36871235)
    • (2003) Analytical Chemistry , vol.75 , Issue.14 , pp. 3451-3459
    • Ye, K.1    Schultz, J.S.2
  • 30
    • 70349331596 scopus 로고    scopus 로고
    • Genetically encoded biosensors based on engineered fluorescent proteins
    • W. Frommer, M. Davidson, and R. Campbell, "Genetically encoded biosensors based on engineered fluorescent proteins," Chem. Soc. Rev., vol. 38, pp. 2833-2841, 2009.
    • (2009) Chem. Soc. Rev. , vol.38 , pp. 2833-2841
    • Frommer, W.1    Davidson, M.2    Campbell, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.