메뉴 건너뛰기




Volumn 155, Issue 1, 2011, Pages 214-219

In vitro assessing the risk of drug-induced cardiotoxicity by embryonic stem cell-based biosensor

Author keywords

Cell based biosensor; Drug induced cardiotoxicity; Embryonic stem cell; Light addressable potentiometric sensor

Indexed keywords

ACTION POTENTIALS; AMIODARONE; CARDIOMYOCYTES; CARDIOTOXICITY; CELL CLUSTERS; CELL SHAPES; CELL-BASED BIOSENSOR; DESIRED POSITION; EMBRYONIC STEM CELL; EMBRYONIC STEMS; EXTRACELLULAR POTENTIAL; HIGH-THROUGHPUT; IN-VITRO; LEVOFLOXACIN; LIGHT ADDRESSABLE POTENTIOMETRIC SENSOR; LIGHT ADDRESSABLE POTENTIOMETRIC SENSORS; MECHANICAL BEATING; MOUSE EMBRYONIC STEM CELLS; NOVEL TECHNIQUES; SAFETY PHARMACOLOGY; SPARFLOXACIN; TIME CHARACTERISTICS; VENTRICULAR REPOLARIZATION;

EID: 79956343571     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2010.11.050     Document Type: Article
Times cited : (33)

References (33)
  • 1
    • 27744587040 scopus 로고    scopus 로고
    • Clinical trial design to evaluate the effects of drugs on cardiac repolarization: Current state of the art
    • A.J. Camm Clinical trial design to evaluate the effects of drugs on cardiac repolarization: current state of the art Heart Rhythm. 2 2005 S23 S29
    • (2005) Heart Rhythm. , vol.2
    • Camm, A.J.1
  • 3
    • 33845435347 scopus 로고    scopus 로고
    • Drug-induced long QT and torsade de pointes: Recent advances
    • DOI 10.1097/HCO.0b013e32801129eb, PII 0000157320070100000008
    • P.J. Kannankeril, and D.M. Roden Drug-induced long QT and torsade de pointes: recent advances Curr. Opin. Cardiol. 22 2007 39 43 (Pubitemid 44901054)
    • (2007) Current Opinion in Cardiology , vol.22 , Issue.1 , pp. 39-43
    • Kannankeril, P.J.1    Roden, D.M.2
  • 4
    • 27744540341 scopus 로고    scopus 로고
    • QT prolongation and proarrhythmia by moxifloxacin: Concordance of preclinical models in relation to clinical outcome
    • DOI 10.1038/sj.bjp.0706389, PII 0706389
    • X. Chen, J.D. Cass, J.A. Bradley, C.M. Dahm, Z.Q. Sun, E.M. Kadyszewski, J. Engwall, and J. Zhou QT prolongation and proarrhythmia by moxifloxacin: concordance of preclinical models in relation to clinical outcome Br. J. Pharmacol. 146 2005 792 799 (Pubitemid 41622245)
    • (2005) British Journal of Pharmacology , vol.146 , Issue.6 , pp. 792-799
    • Chen, X.1    Cass, J.D.2    Bradley, J.A.3    Dahm, C.M.4    Sun, Z.5    Kadyszewski, E.6    Engwall, M.J.7    Zhou, J.8
  • 5
    • 0036185306 scopus 로고    scopus 로고
    • The imprecision in heart rate correction may lead to artificial observations of drug induced QT interval changes
    • M. Malik The imprecision in heart rate correction may lead to artificial observations of drug induced QT interval changes Pacing. Clin. Electrophysiol. 25 2002 209 216 (Pubitemid 34214594)
    • (2002) PACE - Pacing and Clinical Electrophysiology , vol.25 , Issue.2 , pp. 209-216
    • Malik, M.1
  • 6
    • 48149086386 scopus 로고    scopus 로고
    • Preclinical assessment of cardiac toxicity
    • R. Kettenhofen, and H. Bohlen Preclinical assessment of cardiac toxicity Drug Discov. Today 13 15-16 2008 702 707
    • (2008) Drug Discov. Today , vol.13 , Issue.1516 , pp. 702-707
    • Kettenhofen, R.1    Bohlen, H.2
  • 7
    • 0042045214 scopus 로고    scopus 로고
    • Whole cell biosensors
    • PII S0925400596019065
    • L. Bousse Whole cell biosensors Sens. Actuat. B Chem. 34 1996 270 275 (Pubitemid 126379872)
    • (1996) Sensors and Actuators, B: Chemical , vol.34 , Issue.1-3 , pp. 270-275
    • Bousse, L.1
  • 11
    • 0029052186 scopus 로고
    • The use of neuronal networks on multielectrode arrays as biosensors
    • G.W. Gross, B.K. Rhoades, H.M. Azzazy, and M.C. Wu The use of neuronal networks on multielectrode arrays as biosensors Biosens. Bioelectron. 10 1995 553 567
    • (1995) Biosens. Bioelectron. , vol.10 , pp. 553-567
    • Gross, G.W.1    Rhoades, B.K.2    Azzazy, H.M.3    Wu, M.C.4
  • 12
    • 0033083227 scopus 로고    scopus 로고
    • The neurochip: A new multielectrode device for stimulating and recording from cultured neurons
    • DOI 10.1016/S0165-0270(98)00156-3, PII S0165027098001563
    • M.P. Maher, J. Pine, J. Wright, and Y.C. Tai The neurochip: a new multielectrode device for stimulating and recording from cultured neurons J. Neurosci. Methods 87 1999 45 56 (Pubitemid 29087085)
    • (1999) Journal of Neuroscience Methods , vol.87 , Issue.1 , pp. 45-56
    • Maher, M.P.1    Pine, J.2    Wright, J.3    Tai, Y.-C.4
  • 13
    • 0035253614 scopus 로고    scopus 로고
    • Cell-transistor hybrid systems and their potential applications
    • DOI 10.1016/S0167-7799(00)01544-4, PII S0167779900015444
    • A. Offenhausser, and W. Knoll Cell-transistor hybrid systems and their potential applications Trends Biotechnol. 19 2001 62 66 (Pubitemid 32112683)
    • (2001) Trends in Biotechnology , vol.19 , Issue.2 , pp. 62-66
    • Offenhausser, A.1    Knoll, W.2
  • 14
    • 0344512707 scopus 로고    scopus 로고
    • Electronic sensors with living cellular components
    • G.T.A. Kovacs Electronic sensors with living cellular components Proc. IEEE 91 2003 915 929
    • (2003) Proc. IEEE , vol.91 , pp. 915-929
    • Kovacs, G.T.A.1
  • 15
    • 10244235353 scopus 로고    scopus 로고
    • QT-screen: High-throughput cardiac safety pharmacology by extracellular electrophysiology on primary cardiac myocytes
    • DOI 10.1089/adt.2004.2.507
    • T. Meyer, C. Leisgen, B. Gonser, and E. Gunther QT-screen: high-throughput cardiac safety pharmacology by extracellular electrophysiology on primary cardiac myocytes Assay Drug. Dev. Technol. 2 2004 507 514 (Pubitemid 39619093)
    • (2004) Assay and Drug Development Technologies , vol.2 , Issue.5 , pp. 507-514
    • Meyer, T.1    Leisgen, C.2    Gonser, B.3    Gunther, E.4
  • 16
    • 4544254897 scopus 로고    scopus 로고
    • Micro-electrode arrays in cardiac safety pharmacology: A novel tool to study QT interval prolongation
    • DOI 10.2165/00002018-200427110-00002
    • T. Meyer, K.H. Boven, E. Gunther, and M. Fejtl Micro-electrode arrays in cardiac safety pharmacology: a novel tool to study QT interval prolongation Drug Saf. 27 2004 763 772 (Pubitemid 39243560)
    • (2004) Drug Safety , vol.27 , Issue.11 , pp. 763-772
    • Meyer, T.1    Boven, K.-H.2    Gunther, E.3    Fejtl, M.4
  • 18
    • 76749151845 scopus 로고    scopus 로고
    • Prediction of drug-induced cardiotoxicity using human embryonic stem cell-derived cardiomyocytes
    • S.R. Braam, L. Tertoolen, A. Stolpe, T. Meyer, R. Passier, and C.L. Mummery Prediction of drug-induced cardiotoxicity using human embryonic stem cell-derived cardiomyocytes Stem Cell Res. 4 2010 107 116
    • (2010) Stem Cell Res. , vol.4 , pp. 107-116
    • Braam, S.R.1    Tertoolen, L.2    Stolpe, A.3    Meyer, T.4    Passier, R.5    Mummery, C.L.6
  • 19
    • 0038444178 scopus 로고    scopus 로고
    • Development of electrical activity in cardiac myocyte aggregates derived from mouse embryonic stem cells
    • K. Banach, M.D. Halbach, P. Hu, J. Hescheler, and U. Egert Development of electrical activity in cardiac myocyte aggregates derived from mouse embryonic stem cells Am. J. Physiol. Heart Circ. Physiol. 284 2003 2114 2123
    • (2003) Am. J. Physiol. Heart Circ. Physiol. , vol.284 , pp. 2114-2123
    • Banach, K.1    Halbach, M.D.2    Hu, P.3    Hescheler, J.4    Egert, U.5
  • 20
    • 0024298341 scopus 로고
    • Light-addressable potentiometric sensor for biochemical systems
    • D.G. Hafeman, J.W. Parce, and H.M. McConnell Light-addressable potentiometric sensor for biochemical systems Science 240 1988 1182 1185
    • (1988) Science , vol.240 , pp. 1182-1185
    • Hafeman, D.G.1    Parce, J.W.2    McConnell, H.M.3
  • 22
  • 23
    • 1342285637 scopus 로고    scopus 로고
    • Extracellular measurements of averaged ionic currents with the light-addressable potentiometric sensor (LAPS)
    • B. Stein, M. George, H.E. Gaub, and W.J. Parak Extracellular measurements of averaged ionic currents with the light-addressable potentiometric sensor (LAPS) Sens. Actuat. B 98 2004 299 304
    • (2004) Sens. Actuat. B , vol.98 , pp. 299-304
    • Stein, B.1    George, M.2    Gaub, H.E.3    Parak, W.J.4
  • 24
    • 33747592131 scopus 로고    scopus 로고
    • Olfactory cell-based biosensor: A first step towards a neurochip of bioelectronic nose
    • DOI 10.1016/j.bios.2006.01.016, PII S0956566306000315
    • Q. Liu, H. Cai, Y. Xu, Y. Li, R. Li, and P. Wang Olfactory cell-based biosensor: a first step towards a neurochip of bioelectronic nose Biosens. Bioelectron. 22 2006 318 322 (Pubitemid 44262491)
    • (2006) Biosensors and Bioelectronics , vol.22 , Issue.2 , pp. 318-322
    • Liu, Q.1    Cai, H.2    Xu, Y.3    Li, Y.4    Li, R.5    Wang, P.6
  • 25
    • 34249038338 scopus 로고    scopus 로고
    • Detection of heavy metal toxicity using cardiac cell-based biosensor
    • DOI 10.1016/j.bios.2007.03.005, PII S0956566307001571, Chem and Biosensing Transistors: from materials to systems
    • Q. Liu, H. Cai, Y. Xu, L. Xiao, M. Yang, and P. Wang Detection of heavy metal toxicity using cardiac cell-based biosensor Biosens. Bioelectron. 22 2007 3224 3229 (Pubitemid 46778825)
    • (2007) Biosensors and Bioelectronics , vol.22 , Issue.12 , pp. 3224-3229
    • Liu, Q.1    Cai, H.2    Xu, Y.3    Xiao, L.4    Yang, M.5    Wang, P.6
  • 26
    • 33845502082 scopus 로고    scopus 로고
    • Embryonic stem cells as a novel cell source of cell-based biosensors
    • DOI 10.1016/j.bios.2006.03.006, PII S0956566306000947
    • Q. Liu, H. Huang, H. Cai, Y. Xu, Y. Li, R. Li, and P. Wang Embryonic stem cells as a novel cell source of cell-based biosensor Biosens. Bioelectron. 22 2007 810 815 (Pubitemid 44914046)
    • (2007) Biosensors and Bioelectronics , vol.22 , Issue.6 , pp. 810-815
    • Liu, Q.1    Huang, H.2    Cai, H.3    Xu, Y.4    Li, Y.5    Li, R.6    Wang, P.7
  • 27
    • 0034833181 scopus 로고    scopus 로고
    • Novel design of multi-light LAPS based on digital compensation of frequency domain
    • DOI 10.1016/S0925-4005(00)00696-1
    • Q. Zhang, P. Wang, J.P. Wolfgang, M. George, and G. Zhang A novel design of multi-light LAPS based on digital compensation of frequency domain Sens. Actuat. B 73 2001 152 156 (Pubitemid 32875120)
    • (2001) Sensors and Actuators, B: Chemical , vol.73 , Issue.2-3 , pp. 152-156
    • Qintao, Z.1    Ping, W.2    Parak, W.J.3    George, M.4    Zhang, G.5
  • 28
    • 58149259969 scopus 로고    scopus 로고
    • A novel design of multifunctional integrated cell-based biosensors for simultaneously detecting cell acidification and extracellular potential
    • H. Yu, H. Cai, W. Zhang, L. Xiao, Q. Liu, and P. Wang A novel design of multifunctional integrated cell-based biosensors for simultaneously detecting cell acidification and extracellular potential Biosens. Bioelectron. 24 2009 1462 1468
    • (2009) Biosens. Bioelectron. , vol.24 , pp. 1462-1468
    • Yu, H.1    Cai, H.2    Zhang, W.3    Xiao, L.4    Liu, Q.5    Wang, P.6
  • 30
    • 33644861943 scopus 로고    scopus 로고
    • Effect of ciprofloxacin and levofloxacin on the QT interval: Is this a significant "clinical" event?
    • A.N. Makaryus, K. Byrns, M.N. Makaryus, U. Natarajan, C. Singer, and B. Goldner Effect of ciprofloxacin and levofloxacin on the QT interval: is this a significant "clinical" event? South Med. J. 99 2006 52 56
    • (2006) South Med. J. , vol.99 , pp. 52-56
    • Makaryus, A.N.1    Byrns, K.2    Makaryus, M.N.3    Natarajan, U.4    Singer, C.5    Goldner, B.6
  • 31
    • 67651112016 scopus 로고    scopus 로고
    • Kinetic cell-based morphological screening: Prediction of mechanism of compound action and off-target effects
    • Y.A. Abassi, B. Xi, W. Zhang, P. Ye, S.L. Kirstein, M.R. Gaylord, S.C. Feinstein, X. Wang, and X. Xu Kinetic cell-based morphological screening: prediction of mechanism of compound action and off-target effects Chem. Biol. 31 2009 712 723
    • (2009) Chem. Biol. , vol.31 , pp. 712-723
    • Abassi, Y.A.1    Xi, B.2    Zhang, W.3    Ye, P.4    Kirstein, S.L.5    Gaylord, M.R.6    Feinstein, S.C.7    Wang, X.8    Xu, X.9
  • 32
    • 33644524405 scopus 로고    scopus 로고
    • Are hERG channel inhibition and QT interval prolongation all there is in drug-induced torsadogenesis? A review of emerging trends
    • P. Hoffmann, and B. Warner Are hERG channel inhibition and QT interval prolongation all there is in drug-induced torsadogenesis? A review of emerging trends J. Pharmacol. Toxicol. Methods 53 2006 87 105
    • (2006) J. Pharmacol. Toxicol. Methods , vol.53 , pp. 87-105
    • Hoffmann, P.1    Warner, B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.