-
1
-
-
8644233352
-
Why are total knee replacements revised? Analysis of early revision in a community knee implant registry
-
DOI 10.1097/01.blo.0000147136.98303.9d
-
Gioe TJ, Killeen KK, Grimm K, Mehle S, Scheltema K, Why are total knee replacement revised? - Analysis of early revision in a community knee implant registry, Clin Orthop Relat Res 428:100-106, 2004. (Pubitemid 39506159)
-
(2004)
Clinical Orthopaedics and Related Research
, Issue.428
, pp. 100-106
-
-
Gioe, T.J.1
Killeen, K.K.2
Grimm, K.3
Mehle, S.4
Scheltema, K.5
-
2
-
-
33744772878
-
Socioeconomic issues and demographics of total knee arthroplasty revision
-
DOI 10.1097/01.blo.0000214416.91216.77, PII 0000308620060500000006
-
Saleh KJ, Santos ER, Ghomrawi HM, Parvizi J, Mulhall KJ, Socioeconomic issues and demographics of total knee arthroplasty revision, Clin Orthop Relat Res 446:15-21, 2006. (Pubitemid 44318257)
-
(2006)
Clinical Orthopaedics and Related Research
, Issue.446
, pp. 15-21
-
-
Saleh, K.J.1
Santos, E.R.2
Ghomrawi, H.M.3
Parvizi, J.4
Mulhall, K.J.5
-
3
-
-
0030987956
-
Fatigue failure of cancellous bone: A possible cause of implant migration and loosening
-
Taylor M, Tanner KE, Fatigue failure of cancellous bone: a possible cause of implant migration and loosening, J Bone Joint Surg (Br) 79(2):181-182, 1997.
-
(1997)
J Bone Joint Surg
, vol.79
, Issue.2
, pp. 181-182
-
-
Taylor, M.1
Tanner, K.E.2
-
4
-
-
0020616894
-
Localized bone resorption in the femur in mechanical failure of cemented total hip arthroplasties
-
Carlsson AS, Gentz CF, Linder L, Localized bone resorption in the femur in mechanical failure of cemented total hip arthroplasties, Acta Orthop Scand 54(3):396-402, 1983. (Pubitemid 13053489)
-
(1983)
Acta Orthopaedica Scandinavica
, vol.54
, Issue.3
, pp. 396-402
-
-
Carlsson, A.S.1
Gentz, C.F.2
Linder, L.3
-
5
-
-
0035145732
-
Changes in bone density after cemented total knee arthroplasty: Influence of stem design
-
DOI 10.1054/arth.2001.16486
-
Lonner JH, Klotz M, Levitz C, Lotke PA, Changes in bone density after cemented total knee arthroplasty - influence of stem design, J Arthroplasty 16(1):107-111, 2001. (Pubitemid 32097237)
-
(2001)
Journal of Arthroplasty
, vol.16
, Issue.1
, pp. 107-111
-
-
Lonner, J.H.1
Klotz, M.2
Levitz, C.3
Lotke, P.A.4
-
6
-
-
33744722046
-
Impaction grafting for bone defects in revision total knee arthroplasty
-
DOI 10.1097/01.blo.0000214414.06464.00, PII 0000308620060500000018
-
Lotke PA, Carolan GF, Puri N, Impaction grafting for bone defects in revision total knee arthroplasty, Clin Orthop Relat Res 446:99-103, 2006. (Pubitemid 44318269)
-
(2006)
Clinical Orthopaedics and Related Research
, Issue.446
, pp. 99-103
-
-
Lotke, P.A.1
Carolan, G.F.2
Puri, N.3
-
7
-
-
33744765817
-
Management of bone loss: Structural grafts in revision total knee arthroplasty
-
DOI 10.1097/01.blo.0000214426.52206.2c, PII 0000308620060500000019
-
Backstein D, Safir O, Gross A, Management of bone loss - structural grafts in revision total knee arthroplasty, Clin Orthop Relat Res 446:104-112, 2006. (Pubitemid 44318270)
-
(2006)
Clinical Orthopaedics and Related Research
, Issue.446
, pp. 104-112
-
-
Backstein, D.1
Safir, O.2
Gross, A.3
-
8
-
-
0022498343
-
The influence of tibial component intramedullary stems and implant-cortex contact on the strain distribution of the proximal tibia following total knee arthroplasty: An in vitro study
-
Bourne RB, Finlay JB, The influence of tibial component intramedullary stems and implant-cortex contact on the strain distribution of the proximal tibia following total knee arthroplasty, Clin Orthop Relat Res 208:95-99, 1986. (Pubitemid 16049776)
-
(1986)
Clinical Orthopaedics and Related Research
, vol.208
, pp. 95-99
-
-
Bourne, R.B.1
Finlay, J.B.2
-
9
-
-
0034878493
-
The effect of stem modularity and mode of fixation on tibial component stability in revision total knee arthroplasty
-
DOI 10.1054/arth.2001.25507
-
Jazrawi LM, Bai B, Kummer FJ, Hiebert R, Stuchin SA, The effect of stem modularity and mode of fixation on tibial component stability in revision total knee arthroplasty, J Arthroplasty 16(6):759-767, 2001. (Pubitemid 32803643)
-
(2001)
Journal of Arthroplasty
, vol.16
, Issue.6
, pp. 759-767
-
-
Jazrawi, L.M.1
Bai, B.2
Kummer, F.J.3
Hiebert, R.4
Stuchin, S.A.5
-
10
-
-
0026480316
-
The effect of central stem and stem length on micromovement of the tibial tray
-
Yoshii I, Whiteside LA, Milliano MT, White SE, The effect of central stem and stem length on micromovement of the tibial tray, J Arthroplasty 7(Suppl):433-438, 1992.
-
(1992)
J Arthroplasty
, vol.7
, Issue.SUPPL.
, pp. 433-438
-
-
Yoshii, I.1
Whiteside, L.A.2
Milliano, M.T.3
White, S.E.4
-
11
-
-
0026582767
-
Early migration of prosthesis related to long-term survivorship - Comparison of tibial components in knee replacement
-
Grewal R, Rimmer MG, Freeman MAR, Early migration of prosthesis related to long-term survivorship - comparison of tibial components in knee replacement, J Bone Joint Surg (Br) 74(2):239-242, 1992.
-
(1992)
J Bone Joint Surg
, vol.74
, Issue.2
, pp. 239-242
-
-
Grewal, R.1
Rimmer, M.G.2
Freeman, M.A.R.3
-
12
-
-
0029056371
-
Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses
-
Ryd L, Albrektsson BEJ, Carlsson L, Dansgard F, Herberts P, Lindstrand A, Regner L, Toksvig-Larsen S, Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses, J Bone Joint Surg (Br) 77(3):377-383, 1995.
-
(1995)
J Bone Joint Surg
, vol.77
, Issue.3
, pp. 377-383
-
-
Ryd, L.1
Albrektsson, B.E.J.2
Carlsson, L.3
Dansgard, F.4
Herberts, P.5
Lindstrand, A.6
Regner, L.7
Toksvig-Larsen, S.8
-
13
-
-
0019644475
-
Analysis of model variables and fixation post length effects on stresses around a prosthesis in the proximal tibia
-
Askew MJ, Lewis JL, Analysis of model variables and fixation post length effects on stresses around a prosthesis in the proximal tibia, J Biomech Eng 103:239-245, 1981. (Pubitemid 12174212)
-
(1981)
Journal of Biomechanical Engineering
, vol.103
, Issue.4
, pp. 239-245
-
-
Askew, M.J.1
Lewis, J.L.2
-
14
-
-
0020614940
-
An analysis of tibial component design in total knee arthroplasty
-
Murase K, Crowninshield RD, Pedersen DR, Chang TS, An analysis of tibial component design in total knee arthroplasty, J Biomech 16(1):13-22, 1983. (Pubitemid 13125810)
-
(1983)
Journal of Biomechanics
, vol.16
, Issue.1
, pp. 13-22
-
-
Murase, K.1
Crowninshield, R.D.2
Pedersen, D.R.3
Chang, T.S.4
-
15
-
-
0022456873
-
Epiphyseal-based designs for tibial plateau components - I. Stress analysis in the frontal plane
-
Vasu R, Carter DR, Schurman DJ, Beaupré GS, Epiphyseal-based designs for tibial plateau components - I. Stress analysis in the frontal plane, J Biomech 19(8):647-662, 1986.
-
(1986)
J Biomech
, vol.19
, Issue.8
, pp. 647-662
-
-
Vasu, R.1
Carter, D.R.2
Schurman, D.J.3
Beaupré, G.S.4
-
16
-
-
0021952259
-
Stemmed revision arthroplasty for aseptic loosening of total knee replacement
-
Bertin KC, Freeman MAR, Samuelson KM, Ratcliffe SS, Todd RC, Stemmed revision arthroplasty for aseptic loosening of total knee replacement, J Bone Joint Surg (Br) 67(2):242-248, 1985. (Pubitemid 15109878)
-
(1985)
Journal of Bone and Joint Surgery - Series B
, vol.67
, Issue.2
, pp. 242-248
-
-
Bertin, K.C.1
Freeman, M.A.R.2
Samuelson, K.M.3
-
18
-
-
12144263432
-
A parametric analysis of fixation post shape in tibial knee prostheses
-
DOI 10.1016/j.medengphy.2004.09.010, PII S135045330400181X
-
Au AG, Liggins AB, Raso VJ, Amirfazli A, A parametric analysis of fixation post shape in tibial knee prostheses, Med Eng Phys 27:123-134, 2005. (Pubitemid 40103510)
-
(2005)
Medical Engineering and Physics
, vol.27
, Issue.2
, pp. 123-134
-
-
Au, A.G.1
Liggins, A.B.2
Raso, V.J.3
Amirfazli, A.4
-
19
-
-
38149146205
-
Comparison of tibial fixations in total knee arthroplasty: An evaluation of stress distribution and interface micromotions
-
Rakotomanana RL, Leyvraz PF, Curnier A, Meister JJ, Livio JJ, Comparison of tibial fixations in total knee arthroplasty: an evaluation of stress distribution and interface micromotions, Knee 1:91-99, 1994.
-
(1994)
Knee
, vol.1
, pp. 91-99
-
-
Rakotomanana, R.L.1
Leyvraz, P.F.2
Curnier, A.3
Meister, J.J.4
Livio, J.J.5
-
20
-
-
0034071904
-
The fixation of the cemented femoral component - Effects of stem stiffness, cement thickness and roughness of the cement-bone surface
-
Ramaniraka NA, Rakotomanana LR, Leyvraz PF, The fixation of the cemented femoral component - effects of stem stiffness, cement thickness and roughness of the cement-bone surface, J Bone Joint Surg (Br) 82(2):297-303, 2000.
-
(2000)
J Bone Joint Surg
, vol.82
, Issue.2
, pp. 297-303
-
-
Ramaniraka, N.A.1
Rakotomanana, L.R.2
Leyvraz, P.F.3
-
21
-
-
31544450001
-
Fatigue of the cement/bone interface: The surface texture of bone and loosening
-
DOI 10.1002/jbm.b.30364
-
Arola D, Stoffel KA, Yang DT, Fatigue of the cement/bone interface: the surface texture of bone and loosening, J Biomed Mater Res B Appl Biomater 76:287-297, 2006. (Pubitemid 43165386)
-
(2006)
Journal of Biomedical Materials Research - Part B Applied Biomaterials
, vol.76
, Issue.2
, pp. 287-297
-
-
Arola, D.1
Stoffel, K.A.2
Yang, D.T.3
-
22
-
-
46449101580
-
Experimental microme-chanics of the cement-bone interface
-
Mann KA, Miller MA, Cleary RJ, Janssen D, Verdonschot N, Experimental microme-chanics of the cement-bone interface, J Orthop Res 26:872-879, 2008.
-
(2008)
J Orthop Res
, vol.26
, pp. 872-879
-
-
Mann, K.A.1
Miller, M.A.2
Cleary, R.J.3
Janssen, D.4
Verdonschot, N.5
-
23
-
-
0032053031
-
Finite element analysis of the implanted proximal tibia: A relationship between the initial cancellous bone stresses and implant migration
-
DOI 10.1016/S0021-9290(98)00022-0, PII S0021929098000220
-
Taylor M, Tanner KE, Freeman MAR, Finite element analysis of the implanted proximal tibia: a relationship between the initial cancellous bone stresses and implant migration, J Biomech 31:303-310, 1998. (Pubitemid 28322904)
-
(1998)
Journal of Biomechanics
, vol.31
, Issue.4
, pp. 303-310
-
-
Taylor, M.1
Tanner, K.E.2
Freeman, M.A.R.3
-
24
-
-
2942711408
-
A combined RSA and FE study of the implanted proximal tibia: Correlation of the post-operative mechanical environment with implant migration
-
DOI 10.1016/j.jbiomech.2003.12.004, PII S0021929003004639
-
Perillo-Marcone A, Ryd L, Johnsson K, Taylor M, A combined RSA and FE study of the implanted proximal tibia: correlation of the post-operative mechanical environment with implant migration, J Biomech 37:1205-1213, 2004. (Pubitemid 38798375)
-
(2004)
Journal of Biomechanics
, vol.37
, Issue.8
, pp. 1205-1213
-
-
Perillo-Marcone, A.1
Ryd, L.2
Johnsson, K.3
Taylor, M.4
-
25
-
-
0016801068
-
The elastic and ultimate properties of compact bone tissue
-
Reilly DT, Burstein AH, The elastic and ultimate properties of compact bone tissue, J Biomech 8(6):393-405, 1975.
-
(1975)
J Biomech
, vol.8
, Issue.6
, pp. 393-405
-
-
Reilly, D.T.1
Burstein, A.H.2
-
26
-
-
0021078583
-
The mechanical properties of human tibial trabecular bone as a function of metaphyseal location
-
DOI 10.1016/0021-9290(83)90097-0
-
Goldstein SA, Wilson DL, Sonstegard DA, Matthews LS, The mechanical properties of human tibial trabecular bone as a function of metaphyseal location, J Biomech 16(12):965-969, 1983. (Pubitemid 14151720)
-
(1983)
Journal of Biomechanics
, vol.16
, Issue.12
, pp. 965-969
-
-
Goldstein, S.A.1
Wilson, D.L.2
Sonstegard, D.A.3
Matthews, L.S.4
-
27
-
-
0023510231
-
Adaptive bone-remodeling theory applied to prosthetic-design analysis
-
DOI 10.1016/0021-9290(87)90030-3
-
Huiskes R, Weinans H, Grootenboer HJ, Dalstra M, Fudala B, Slooff TJ, Adaptive bone-remodeling theory applied to prosthetic-design analysis, J Biomech 20(11/12):1135-1150, 1987. (Pubitemid 18010111)
-
(1987)
Journal of Biomechanics
, vol.20
, Issue.11-12
, pp. 1135-1150
-
-
Huiskes, R.1
Weinans, H.2
Grootenboer, H.J.3
Dalstra, M.4
Fudala, B.5
Slooff, T.J.6
-
28
-
-
0027574980
-
Compressive fatigue behavior of bovine trabecular bone
-
Michel MC, Guo XE, Gibson LJ, McMahon TA, Hayes WC, Compressive fatigue behavior of bovine trabecular bone, J Biomech 26(4/5):453-463, 1993. (Pubitemid 23226653)
-
(1993)
Journal of Biomechanics
, vol.26
, Issue.4-5
, pp. 453-463
-
-
Michel, M.C.1
Guo, X.-D.E.2
Gibson, L.J.3
McMahon, T.A.4
Hayes, W.C.5
-
29
-
-
0024382521
-
A parametric axisymmetric model study on the interface motions in porous-surfaced tibial implants
-
Shirazi-Adl A, Ahmed AM, A parametric axisymmetric model study on the interface motions in porous-surfaced tibial implants, Ann Biomed Eng 17:411-421, 1989. (Pubitemid 19188603)
-
(1989)
Annals of Biomedical Engineering
, vol.17
, Issue.4
, pp. 411-421
-
-
Shirazi-Adl, A.1
Ahmed, A.M.2
-
30
-
-
27744509669
-
A circumferentially flanged tibial tray minimizes bone-tray shear micromotion
-
DOI 10.1243/095441105X34464
-
Barker DS, Tanner KE, Ryd L, A circumferentially flanged tibial tray minimizes bone-tray shear micromotion, Proc IMechE Part H - J Eng Med 219:449-456, 2005. (Pubitemid 41581737)
-
(2005)
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
, vol.219
, Issue.6
, pp. 449-456
-
-
Barker, D.S.1
Tanner, K.E.2
Ryd, L.3
-
31
-
-
0019969676
-
Performance of the tibial component in total knee replacement
-
Bartel DL, Burstein AH, Santavicca EA, Insall JN, Performance of the tibial component in total knee replacement, J Bone Joint Surg (Am) 64(7):1026-1033, 1982.
-
(1982)
J Bone Joint Surg
, vol.64
, Issue.7
, pp. 1026-1033
-
-
Bartel, D.L.1
Burstein, A.H.2
Santavicca, E.A.3
Insall, J.N.4
-
32
-
-
33947593021
-
Contribution of loading conditions and material properties to stress shielding near the tibial component of total knee replacements
-
DOI 10.1016/j.jbiomech.2006.05.020, PII S0021929006001886
-
Au AG, Raso VJ, Liggins AB, Amirfazli A, Contribution of loading conditions and material properties to stress shielding near the tibial component of total knee replacement, J Biomech 40:1410-1416, 2007. (Pubitemid 46483452)
-
(2007)
Journal of Biomechanics
, vol.40
, Issue.6
, pp. 1410-1416
-
-
Au, A.G.1
James Raso, V.2
Liggins, A.B.3
Amirfazli, A.4
-
33
-
-
79956071945
-
Microstrain on the cortex and within the bone of the distal femur with cemented and uncemented femoral components in total knee arthroplasty
-
Seki T, Tashiro T, Omori G, Terashima S, Koga Y, Sakamoto M, Hara T, Takahashi EH, Microstrain on the cortex and within the bone of the distal femur with cemented and uncemented femoral components in total knee arthroplasty, Transactions of the 44th Annual Meeting Orthopaedic Research Society, pp. 699, 1998.
-
(1998)
Transactions of the 44th Annual Meeting Orthopaedic Research Society
, pp. 699
-
-
Seki, T.1
Tashiro, T.2
Omori, G.3
Terashima, S.4
Koga, Y.5
Sakamoto, M.6
Hara, T.7
Takahashi, E.H.8
-
34
-
-
0033034569
-
Correlation between pre-operative periprosthetic bone density and post-operative bone loss in THA can be explained by strain-adaptive remodelling
-
DOI 10.1016/S0021-9290(99)00041-X, PII S002192909900041X
-
Kerner J, Huiskes R, van Lenthe GH, Weinans H, van Rietbergen B, Engh CA, Amis AA, Correlation between pre-operative periprosthetic bone density and post-operative bone loss in THA can be explained by strain-adaptive remodeling, J Biomech 32:695-703, 1999. (Pubitemid 29322089)
-
(1999)
Journal of Biomechanics
, vol.32
, Issue.7
, pp. 695-703
-
-
Kerner, J.1
Huiskes, R.2
Van Lenthe, G.H.3
Weinans, H.4
Van Rietbergen, B.5
Engh, C.A.6
Amis, A.A.7
-
35
-
-
7044238389
-
The effect of muscle loading on the simulation of bone remodelling in the proximal femur
-
DOI 10.1016/j.jbiomech.2004.03.005, PII S0021929004001435
-
Bitsakos C, Kerner J, Fisher I, Amis A, The effect of muscle loading on the the simulation of bone remodeling in the proximal femur, J Biomech 38:133-139, 2005. (Pubitemid 39424987)
-
(2005)
Journal of Biomechanics
, vol.38
, Issue.1
, pp. 133-139
-
-
Bitsakos, C.1
Kerner, J.2
Fisher, I.3
Amis, A.A.4
-
36
-
-
0142118254
-
A different fixation of the femoral component in total knee arthroplasty may lead to preservation of femoral bone stock
-
Barink M, Verdonschot N, de Waal Malefijt M, A different fixation of the femoral component in total knee arthroplasty may lead to preservation of femoral bone stock, Proc IMechE Part H - J Eng Med 217:325-332, 2003.
-
(2003)
Proc IMechE Part H - J Eng Med
, vol.217
, pp. 325-332
-
-
Barink, M.1
Verdonschot, N.2
De Waal Malefijt, M.3
-
37
-
-
79956136156
-
The short-term and long-term behaviour of orthopaedic implant anchorage: Finite element models
-
Middleton J, Jones ML, Shrive NG, Pande GN (Eds.) Gordon and Breach Science Publishers, Amsterdam, The Netherlands
-
Rakotomanana L, The short-term and long-term behaviour of orthopaedic implant anchorage: finite element models, in Middleton J, Jones ML, Shrive NG, Pande GN (Eds.), Computer Methods in Biomechanics & Biomedical Engineering - 3, Gordon and Breach Science Publishers, Amsterdam, The Netherlands, pp. 1-8, 2001.
-
(2001)
Computer Methods in Biomechanics & Biomedical Engineering - 3
, pp. 1-8
-
-
Rakotomanana, L.1
-
38
-
-
0023098711
-
Long-term results after total condylar knee arthroplasty. Significance of radiolucent lines
-
Ecker ML, Lotke PA, Windsor RE, Cella JP, Long-term results after total condylar knee arthroplasty - significance of radiolucent lines, Clin Orthop Relat Res 216:151-158, 1987. (Pubitemid 17040722)
-
(1987)
Clinical Orthopaedics and Related Research
, vol.216
, pp. 151-158
-
-
Ecker, M.L.1
Lotke, P.A.2
Windsor, R.E.3
Cella, J.P.4
-
39
-
-
0028917920
-
A follow-up study of porous-coated anatomic knee arthroplasty
-
Hsu RWW, Fan GF, Ho WP, A follow-up study of porous-coated anatomic knee arthroplasty, J Arthroplasty 10(1):29-36, 1995.
-
(1995)
J Arthroplasty
, vol.10
, Issue.1
, pp. 29-36
-
-
Hsu, R.W.W.1
Fan, G.F.2
Ho, W.P.3
-
40
-
-
0031028017
-
Joint load considerations in total knee replacement
-
Kuster MS, Wood GA, Stachowiak GW, Gächter A, Joint load considerations in total knee replacement, J Bone Joint Surg (Br) 79(1):109-113, 1997.
-
(1997)
J Bone Joint Surg
, vol.79
, Issue.1
, pp. 109-113
-
-
Kuster, M.S.1
Wood, G.A.2
Stachowiak, G.W.3
Gächter, A.4
-
41
-
-
0034318763
-
On the magnitude and variability of the fatigue strength of acrylic bone cement
-
DOI 10.1016/S0142-1123(00)00055-4
-
Murphy BP, Prendergast PJ, On the magnitude and variability of the fatigue strength of acrylic bone cement, Int J Fatigue 22(10):855-864, 2000. (Pubitemid 32030234)
-
(2000)
International Journal of Fatigue
, vol.22
, Issue.10
, pp. 855-864
-
-
Murphy, B.P.1
Prendergast, P.J.2
-
42
-
-
0035406037
-
Long-term followup of cementless versus hybrid fixation for total knee arthroplasty
-
Parker DA, Rorabeck CH, Bourne RB, Long-term follow up of cementless versus hybrid fixation for total knee arthroplasty, Clin Orthop Relat Res 388:68-76, 2001. (Pubitemid 32595008)
-
(2001)
Clinical Orthopaedics and Related Research
, Issue.388
, pp. 68-76
-
-
Parker, D.A.1
Rorabeck, C.H.2
Bourne, R.B.3
-
43
-
-
0025303681
-
Porous coated anatomic tricompartmental tibial components. The relationship between prosthetic position and micromotion
-
Ryd L, Lindstrand A, Stenstrom A, Selvik G, Porous coated anatomic tricompart-mental tibial components - the relationship between prosthetic position and micro-motion, Clin Orthop Relat Res 251:189-197, 1990. (Pubitemid 20088643)
-
(1990)
Clinical Orthopaedics and Related Research
, Issue.251
, pp. 189-197
-
-
Ryd, L.1
Lindstrand, A.2
Stenstrom, A.3
Selvik, G.4
-
44
-
-
0034013406
-
Changes in bone mineral density at the proximal tibia after total knee arthroplasty: A 2-year follow-up of 28 knees using dual energy x-ray absorptiom-etry
-
Li MG, Nilsson KG, Changes in bone mineral density at the proximal tibia after total knee arthroplasty: a 2-year follow-up of 28 knees using dual energy x-ray absorptiom-etry, J Orthop Res 18(1):40-47, 2000.
-
(2000)
J Orthop Res
, vol.18
, Issue.1
, pp. 40-47
-
-
Li, M.G.1
Nilsson, K.G.2
-
45
-
-
33846820235
-
All-polyethylene and metal-backed tibias have similar outcomes at 10 years
-
Gioe TJ, Stroemer ES, Santos ERG, All-polyethylene and metal-backed tibias have similar outcomes at 10 years, Clin Orthop Relat Res 455:212-218, 2007.
-
(2007)
Clin Orthop Relat Res
, vol.455
, pp. 212-218
-
-
Gioe, T.J.1
Stroemer, E.S.2
Santos, E.R.G.3
-
46
-
-
0141889896
-
All-polyethylene and metal-backed tibial components in total knee arthroplasty: A matched pair analysis of functional outcome
-
DOI 10.1016/S0883-5403(03)00304-8
-
Najibi S, Iorio R, Surdam JW, Whang W, Appleby D, Healy WL, All-polyethylene and metal-backed tibial components in total knee arthroplasty: a matched pair analysis of functional outcome, J Arthroplasty 18(7 Suppl 1):9-15, 2003. (Pubitemid 37259659)
-
(2003)
Journal of Arthroplasty
, vol.18
, Issue.7 SUPPL. 1
, pp. 9-15
-
-
Najibi, S.1
Iorio, R.2
Surdam, J.W.3
Whang, W.4
Appleby, D.5
Healy, W.L.6
-
47
-
-
0035163418
-
Metal-backed and all-polyethylene tibial components in total knee replacement
-
Rodriguez JA, Baez N, Rasquinha V, Ranawat CS, Metal-backed and all-polyethylene tibial components in total knee replacement, Clin Orthop Relat Res 392:174-183, 2001. (Pubitemid 33054942)
-
(2001)
Clinical Orthopaedics and Related Research
, Issue.392
, pp. 174-183
-
-
Rodriguez, J.A.1
Baez, N.2
Rasquinha, V.3
Ranawat, C.S.4
-
48
-
-
0034071250
-
Sensitivity of periprosthetic stress-shielding to load and the bone density-modulus relationship in subject-specific finite element models
-
DOI 10.1016/S0021-9290(00)00036-1, PII S0021929000000361
-
Weinans H, Sumner DR, Igloria R, Natarajan RN, Sensitivity of periprosthetic stress shielding to load and the bone density-modulus relationship in subject-specific finite element models, J Biomech 33(7):809-817, 2000. (Pubitemid 30265574)
-
(2000)
Journal of Biomechanics
, vol.33
, Issue.7
, pp. 809-817
-
-
Weinans, H.1
R. Sumner, D.2
Igloria, R.3
Natarajan, R.N.4
|