메뉴 건너뛰기




Volumn 28, Issue 2, 2011, Pages 49-52

An investigation into the effect of fabrication parameter variation on the characteristics of screen-printed thick-film silver/silver chloride reference electrodes

Author keywords

Chloride; Electrochemistry; Electrodes; Films (states of matter); Salt; Silver

Indexed keywords

BACK CONTACT; BINDER MATERIAL; CHARACTERISATION; CHLORIDE; CHLORIDE ENVIRONMENT; DEPOSITION METHODS; DESIGN/METHODOLOGY/APPROACH; DEVICE CHARACTERISTICS; DRIFT RATES; ELECTRODE POTENTIALS; ELECTRODE STABILITY; FABRICATION PARAMETERS; FILMS (STATES OF MATTER); FUNCTION OF TIME; INTERFACIAL LAYER; OPTIMISATIONS; PLANAR STRUCTURE; POTASSIUM CHLORIDE; REFERENCE ELECTRODES; RESPONSE TIME; SALT CONCENTRATION; SCREEN-PRINTED; TEST FLUIDS; TESTED DEVICES; USEFUL LIFETIME;

EID: 79956069863     PISSN: 13565362     EISSN: None     Source Type: Journal    
DOI: 10.1108/13565361111127368     Document Type: Article
Times cited : (24)

References (15)
  • 1
    • 0037156531 scopus 로고    scopus 로고
    • Screen-printed electrode based on ache for the detection of pesticides in presence of organic solvents
    • DOI 10.1016/S0039-9140(02)00017-6, PII S0039914002000176
    • Andreescu, S., Noguer, T., Magearu, V. and Marty, J-L. (2002), Screen-printed electrode based on AChE for the detection of pesticides in presence of organic solvents Talanta, Vol. 57, pp. 169-76. (Pubitemid 34453502)
    • (2002) Talanta , vol.57 , Issue.1 , pp. 169-176
    • Andreescu, S.1    Noguer, T.2    Magearu, V.3    Marty, J.-L.4
  • 2
    • 0032641447 scopus 로고    scopus 로고
    • An investigation of the performance characteristics and operational lifetimes of multi-element thick film sensor arrays used in the determination of water quality parameters
    • Atkinson, J.K., Cranny, A.W.J., Glasspool, W.V. and Mihell, J.A. (1999), An investigation of the performance characteristics and operational lifetimes of multi-element thick film sensor arrays used in the determination of water quality parameters Sensors and Actuators B: Chemical, Vol. 54 No. 3, pp. 215-31.
    • (1999) Sensors and Actuators B: Chemical , vol.54 , Issue.3 , pp. 215-231
    • Atkinson, J.K.1    Cranny, A.W.J.2    Glasspool, W.V.3    Mihell, J.A.4
  • 3
    • 0034253374 scopus 로고    scopus 로고
    • Development of a disposable ethanol biosensor based on a chemically modified screen-printed electrode coated with alcohol oxidase for the analysis of beer
    • Boujtita, M., Hart, J.P. and Pittson, R. (2000), Development of a disposable ethanol biosensor based on a chemically modified screen-printed electrode coated with alcohol oxidase for the analysis of beer Biosensors & Bioelectronics, Vol. 15, pp. 257-63.
    • (2000) Biosensors & Bioelectronics , vol.15 , pp. 257-263
    • Boujtita, M.1    Hart, J.P.2    Pittson, R.3
  • 4
    • 0032166067 scopus 로고    scopus 로고
    • Thick film silver-silver chloride reference electrodes
    • Cranny, A.W.J. and Atkinson, J.K. (1998), Thick film silver-silver chloride reference electrodes Measurement Science and Technology, Vol. 9 No. 9, pp. 1557-65.
    • (1998) Measurement Science and Technology , vol.9 , Issue.9 , pp. 1557-1565
    • Cranny, A.W.J.1    Atkinson, J.K.2
  • 5
    • 0036994841 scopus 로고    scopus 로고
    • A comparison of thick-film chemical sensor characteristics in laboratory and on-line industrial process applications
    • DOI 10.1088/0957-0233/13/12/335, PII S0957023302362465
    • Gac, A., Atkinson, J.K., Zhang, Z. and Sion, R.P. (2002), A comparison of thick-film chemical sensor characteristics in laboratory and on-line industrial process applications Measurement Science and Technology, Vol. 13, pp. 2062-73. (Pubitemid 36225182)
    • (2002) Measurement Science and Technology , vol.13 , Issue.12 , pp. 2062-2073
    • Gac, A.1    Atkinson, J.K.2    Zhang, Z.3    Sion, R.P.4
  • 6
    • 4143079309 scopus 로고    scopus 로고
    • Investigation of the fabrication parameters of thick film titanium oxide-PVC pH electrodes using experimental designs
    • Gac, A., Atkinson, J.K., Zhang, Z., Sexton, C.J., Lewis, S.M., Please, C.P. and Sion, R.P. (2004), Investigation of the fabrication parameters of thick film titanium oxide-PVC pH electrodes using experimental designs Microelectronics International, Vols. 21/3, pp. 44-53.
    • (2004) Microelectronics International , vol.21 , Issue.3 , pp. 44-53
    • Gac, A.1    Atkinson, J.K.2    Zhang, Z.3    Sexton, C.J.4    Lewis, S.M.5    Please, C.P.6    Sion, R.P.7
  • 7
    • 0038055928 scopus 로고    scopus 로고
    • An evaluation of the characteristics of membrane materials suitable for the batch fabrication of dissolved oxygen sensors
    • Glasspool, W.V. and Atkinson, J.K. (2003), An evaluation of the characteristics of membrane materials suitable for the batch fabrication of dissolved oxygen sensors Microelectronics International, Vol. 20 No. 2, pp. 32-40.
    • (2003) Microelectronics International , vol.20 , Issue.2 , pp. 32-40
    • Glasspool, W.V.1    Atkinson, J.K.2
  • 8
    • 33645966802 scopus 로고    scopus 로고
    • All-solid-state miniaturised planar reference electrodes based on ionic liquids
    • Maminska, R., Dybko, A. and Wroblewski, W. (2006), All-solid-state miniaturised planar reference electrodes based on ionic liquids Sensors and Actuators B, Vol. 115, pp. 552-7.
    • (2006) Sensors and Actuators B , vol.115 , pp. 552-557
    • Maminska, R.1    Dybko, A.2    Wroblewski, W.3
  • 9
    • 0036644776 scopus 로고    scopus 로고
    • Development of a micro-planar Ag/AgCl quasi-reference electrode with long-term stability for an amperometric glucose sensor
    • DOI 10.1016/S0003-2670(02)00334-3, PII S0003267002003343
    • Matsumoto, T., Ohashi, A. and Ito, N. (2002), Development of a micro-planar Ag/AgCl quasi-reference electrode with long-term stability for an amperometric glucose sensor Analytica Chimica Acta, Vol. 462, pp. 253-9. (Pubitemid 34686952)
    • (2002) Analytica Chimica Acta , vol.462 , Issue.2 , pp. 253-259
    • Matsumoto, T.1    Ohashi, A.2    Ito, N.3
  • 10
    • 0347671066 scopus 로고    scopus 로고
    • Planar thick-film pH electrodes based on ruthenium dioxide hydrate
    • PII S0925400598000902
    • Mihell, J.A. and Atkinson, J.K. (1998), Planar thick-film pH electrodes based on ruthenium dioxide hydrate Sensors and Actuators B: Chemical, Vol. 48 Nos 1-3, pp. 505-11. (Pubitemid 128443218)
    • (1998) Sensors and Actuators, B: Chemical , vol.48 , Issue.1-3 , pp. 505-511
    • Mihell, J.A.1    Atkinson, J.K.2
  • 12
    • 7944224886 scopus 로고    scopus 로고
    • Screen-printed reference electrodes for potentiometric measurements
    • Tymeckia, Ł., Zwierkowskab, E. and Koncki, R. (2004), Screen-printed reference electrodes for potentiometric measurements Analytica Chimica Acta, Vol. 526, pp. 3-11.
    • (2004) Analytica Chimica Acta , vol.526 , pp. 3-11
    • Tymeckia, Ł.1
  • 13
    • 0040320213 scopus 로고    scopus 로고
    • An agar-based silversilver chloride reference electrode for use in micro-electrochemistry
    • PII S1388248199000351
    • Hassel, A.H., Fushimi, K. and Seo, M. (1999), An agar-based silver/silver chloride reference electrode for use in microelectrochemistry Electrochemistry Communications, Vol. 1, pp. 180-3. (Pubitemid 129499971)
    • (1999) Electrochemistry Communications , vol.1 , Issue.5 , pp. 180-183
    • Hassel, A.W.1    Fushimi, K.2    Seo, M.3
  • 14
    • 14744299684 scopus 로고    scopus 로고
    • New concepts of miniaturised reference electrodes in silicon technology for potentiometric sensor systems
    • DOI 10.1016/j.snb.2004.04.072, PII S0925400504002692, The 17th European Conference on Solid-State Transducers, University of Minho, Guimares, Portugal, September 21-24, 2003
    • Simonis, A., Lüth, H., Wang, J. and Schöning, M.J. (2004), New concepts of miniaturised reference electrodes in silicon technologyfor potentiometric sensor systems Sensors and Actuators B, Vol. 103, pp. 429-35. (Pubitemid 40329241)
    • (2004) Sensors and Actuators, B: Chemical , vol.103 , Issue.1-2 , pp. 429-435
    • Simonis, A.1    Luth, H.2    Wang, J.3    Schoning, M.J.4
  • 15
    • 7944224886 scopus 로고    scopus 로고
    • Screen-printed reference electrodes for potentiometric measurements
    • DOI 10.1016/j.aca.2004.08.056, PII S000326700401116X
    • Tymecki, K., Zwierkowska, E. and Koncki, R. (2004), Screen-printed reference electrodes for potentiometric measurements Anal. Chim. Acta, Vol. 526, pp. 3-11. (Pubitemid 39470127)
    • (2004) Analytica Chimica Acta , vol.526 , Issue.1 , pp. 3-11
    • Tymecki, L.1    Zwierkowska, E.2    Koncki, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.