메뉴 건너뛰기




Volumn 13, Issue 12, 2002, Pages 2062-2073

A comparison of thick-film chemical sensor characteristics in laboratory and on-line industrial process applications

Author keywords

Conductivity; Dissolved oxygen; On line monitoring; PH; Reference electrode; Screen printing; Sensor array; Water quality

Indexed keywords

ARRAYS; FOULING; INDUSTRIAL APPLICATIONS; PH SENSORS; REUSABILITY; THICK FILMS; WATER;

EID: 0036994841     PISSN: 09570233     EISSN: None     Source Type: Journal    
DOI: 10.1088/0957-0233/13/12/335     Document Type: Article
Times cited : (14)

References (17)
  • 3
    • 0032166067 scopus 로고    scopus 로고
    • Thick film silver-silver chloride reference electrodes
    • Cranny A and Atkinson J K 1998 Thick film silver-silver chloride reference electrodes Meas. Sci. Technol. 9 1557-65
    • (1998) Meas. Sci. Technol. , vol.9 , pp. 1557-1565
    • Cranny, A.1    Atkinson, J.K.2
  • 4
    • 0030827437 scopus 로고    scopus 로고
    • Screen-printed ruthenium dioxide electrodes for pH measurements
    • Koncki R and Mascini M 1997 Screen-printed ruthenium dioxide electrodes for pH measurements Anal. Chim. Acta 351 143-9
    • (1997) Anal. Chim. Acta , vol.351 , pp. 143-149
    • Koncki, R.1    Mascini, M.2
  • 5
    • 0022559382 scopus 로고
    • A thick film multiple component cathode three electrode oxygen sensor
    • Karagounis V, Lun L and Liu C 1986 A thick film multiple component cathode three electrode oxygen sensor IEEE Trans. Biomed. Eng. 33 108-12
    • (1986) IEEE Trans. Biomed. Eng. , vol.33 , pp. 108-112
    • Karagounis, V.1    Lun, L.2    Liu, C.3
  • 7
    • 0032641447 scopus 로고    scopus 로고
    • Investigation of the performance characteristics and operational lifetimes of multi-element thick film sensor arrays used in the determination of water quality parameters
    • Atkinson J K, Cranny A, Glasspool W V and Mihell J A 1999 Investigation of the performance characteristics and operational lifetimes of multi-element thick film sensor arrays used in the determination of water quality parameters Sensors Actuators B 54 215-31
    • (1999) Sensors Actuators B , vol.54 , pp. 215-231
    • Atkinson, J.K.1    Cranny, A.2    Glasspool, W.V.3    Mihell, J.A.4
  • 10
    • 0021377139 scopus 로고
    • Electronic semiconducting oxides as pH sensors
    • Fog A and Buck R P 1984 Electronic semiconducting oxides as pH sensors Sensors Actuators 5 137-46
    • (1984) Sensors Actuators , vol.5 , pp. 137-146
    • Fog, A.1    Buck, R.P.2
  • 13
    • 0013317099 scopus 로고    scopus 로고
    • An investigation of the factors influencing stability in continuously-powered screen-printed amperometric dissolved oxygen sensors
    • Atkinson J K and Glasspool W V 2001 An investigation of the factors influencing stability in continuously-powered screen-printed amperometric dissolved oxygen sensors Microelectron. Int. 18
    • (2001) Microelectron. Int. , vol.18
    • Atkinson, J.K.1    Glasspool, W.V.2
  • 16
    • 0032067170 scopus 로고    scopus 로고
    • Planar thick-film pH electrodes based on ruthenium dioxide hydrate
    • Mihell J A and Atkinson J K 1998 Planar thick-film pH electrodes based on ruthenium dioxide hydrate Sensors Actuators B 48 505-11
    • (1998) Sensors Actuators B , vol.48 , pp. 505-511
    • Mihell, J.A.1    Atkinson, J.K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.