1
-
-
51849166566
-
Remote monitoring of CRT-ICD: The multicenter Italian CareLink evaluation-ease of use, acceptance, and organizational implications
-
Marzegalli M, Lunati M, Landolina M, et al. Remote monitoring of CRT-ICD: the multicenter Italian CareLink evaluation-ease of use, acceptance, and organizational implications. Pacing Clin Electrophysiol 2008;31:1259-64.
-
(2008)
Pacing Clin Electrophysiol
, vol.31
, pp. 1259-1264
-
-
Marzegalli, M.1
Lunati, M.2
Landolina, M.3
-
2
-
-
71749091499
-
Remote monitoring. The future of implantable cardioverter-defibrillator follow-up
-
Bernard ML, Quin EM, Gold MR. Remote monitoring. The future of implantable cardioverter-defibrillator follow-up. Card Electrophysiol Clin 2009;1:193-200.
-
(2009)
Card Electrophysiol Clin
, vol.1
, pp. 193-200
-
-
Bernard, M.L.1
Quin, E.M.2
Gold, M.R.3
-
3
-
-
67651040063
-
Remote monitoring and follow-up of pacemakers and implantable cardioverter defibrillators
-
Up-to-date review of existing remote technology from different manufacturers and available clinical data
-
Burri H, Senouf D. Remote monitoring and follow-up of pacemakers and implantable cardioverter defibrillators. Europace 2009;11:701-9. Up-to-date review of existing remote technology from different manufacturers and available clinical data.
-
(2009)
Europace
, vol.11
, pp. 701-709
-
-
Burri, H.1
Senouf, D.2
-
4
-
-
77950500674
-
Improving the security and privacy of implantable medical devices
-
Maisel WH, Kohno T. Improving the security and privacy of implantable medical devices. N Engl J Med 2010;362:1164-6.
-
(2010)
N Engl J Med
, vol.362
, pp. 1164-1166
-
-
Maisel, W.H.1
Kohno, T.2
-
5
-
-
41949103591
-
Home monitoring remote control of pacemaker and implantable cardioverter defibrillator patients in clinical practice: Impact on medical management and health-care resource utilization
-
Non-randomised documentation of remote monitoring related nurse and physician activities
-
Ricci RP, Morichelli L, Santini M. Home monitoring remote control of pacemaker and implantable cardioverter defibrillator patients in clinical practice: impact on medical management and health-care resource utilization. Europace 2008;10:164-70. Non-randomised documentation of remote monitoring related nurse and physician activities.
-
(2008)
Europace
, vol.10
, pp. 164-170
-
-
Ricci, R.P.1
Morichelli, L.2
Santini, M.3
-
6
-
-
70349269852
-
Technical reliability and clinical safety of a remote monitoring system for antiarrhythmic cardiac devices
-
Osca J, Sanchotello MJ, Navarro J, et al. Technical reliability and clinical safety of a remote monitoring system for antiarrhythmic cardiac devices. Rev Esp Cardiol 2009;62:886-95.
-
(2009)
Rev Esp Cardiol
, vol.62
, pp. 886-895
-
-
Osca, J.1
Sanchotello, M.J.2
Navarro, J.3
-
7
-
-
12844258988
-
Detection of atrial fibrillation by implanted devices with wireless data transmission capability
-
Varma N, Stambler B, Chun S. Detection of atrial fibrillation by implanted devices with wireless data transmission capability. Pacing Clin Electrophysiol 2005;28(Suppl 1):S133-6.
-
(2005)
Pacing Clin Electrophysiol
, vol.28
, Issue.SUPPL. 1
-
-
Varma, N.1
Stambler, B.2
Chun, S.3
-
8
-
-
44649119926
-
Potential role of remote monitoring for scheduled and unscheduled evaluations of patients with an implantable defibrillator
-
Retrospective database analysis on reasons and actionability of in-clinic ICD follow-up visits
-
Heidbuchel H, Lioen P, Foulon S, et al. Potential role of remote monitoring for scheduled and unscheduled evaluations of patients with an implantable defibrillator. Europace 2008;10:351-7. Retrospective database analysis on reasons and actionability of in-clinic ICD follow-up visits.
-
(2008)
Europace
, vol.10
, pp. 351-357
-
-
Heidbuchel, H.1
Lioen, P.2
Foulon, S.3
-
9
-
-
44649131262
-
HRS/EHRA expert consensus on the monitoring of cardiovascular implantable electronic devices (CIEDs): Description of techniques, indications, personnel, frequency and ethical considerations
-
Elaborate responsibility, timing, data management, ethics and reimbursement considerations related to implantable device follow-up
-
Wilkoff BL, Auricchio A, Brugada J, et al. HRS/EHRA expert consensus on the monitoring of cardiovascular implantable electronic devices (CIEDs): description of techniques, indications, personnel, frequency and ethical considerations. Heart Rhythm 2008;5:907-25. Elaborate responsibility, timing, data management, ethics and reimbursement considerations related to implantable device follow-up.
-
(2008)
Heart Rhythm
, vol.5
, pp. 907-925
-
-
Wilkoff, B.L.1
Auricchio, A.2
Brugada, J.3
-
10
-
-
79251524104
-
Remote follow-up for ICD-therapy in patients meeting Madit II criteria. The REFORM trial
-
abstract
-
Wetzel U, Geller C, Kautzner J, et al. Remote follow-up for ICD-therapy in patients meeting Madit II criteria. The REFORM trial (abstract). Hearth Rhythm 2009;6:S259.
-
(2009)
Hearth Rhythm
, vol.6
-
-
Wetzel, U.1
Geller, C.2
Kautzner, J.3
-
11
-
-
77955171126
-
Efficacy and safety of automatic remote monitoring for implantable cardioverter-defibrillator follow-up: The Lumos-T Safely Reduces Routine Office Device Follow-up (TRUST) trial
-
Largest prospective study showing a significant reduction of in-person visits by using remote follow-up in ICD patients
-
Varma N, Epstein AE, Irimpen A, et al. Efficacy and safety of automatic remote monitoring for implantable cardioverter-defibrillator follow-up: the Lumos-T Safely Reduces Routine Office Device Follow-up (TRUST) trial. Circulation 2010;122:325-32. Largest prospective study showing a significant reduction of in-person visits by using remote follow-up in ICD patients.
-
(2010)
Circulation
, vol.122
, pp. 325-332
-
-
Varma, N.1
Epstein, A.E.2
Irimpen, A.3
-
12
-
-
12844264192
-
Potential cost savings by telemedicine-assisted long-term care of implantable cardioverter defibrillator recipients
-
Fauchier L, Sadoul N, Kouakam C, et al. Potential cost savings by telemedicine-assisted long-term care of implantable cardioverter defibrillator recipients. Pacing Clin Electrophysiol 2005;28(Suppl 1):S255-9.
-
(2005)
Pacing Clin Electrophysiol
, vol.28
, Issue.SUPPL. 1
-
-
Fauchier, L.1
Sadoul, N.2
Kouakam, C.3
-
13
-
-
65249116913
-
Potential role of home monitoring to reduce inappropriate shocks in implantable cardioverter-defibrillator patients due to lead failure
-
Spencker S, Coban N, Koch L, et al. Potential role of home monitoring to reduce inappropriate shocks in implantable cardioverter-defibrillator patients due to lead failure. Europace 2009;11:483-8.
-
(2009)
Europace
, vol.11
, pp. 483-488
-
-
Spencker, S.1
Coban, N.2
Koch, L.3
-
14
-
-
59449094988
-
Remote monitoring of patients with biventricular defibrillators through the CareLink system improves clinical management of arrhythmias and heart failure episodes
-
Santini M, Ricci RP, Lunati M, et al. Remote monitoring of patients with biventricular defibrillators through the CareLink system improves clinical management of arrhythmias and heart failure episodes. J Interv Card Electrophysiol 2009;24:53-61.
-
(2009)
J Interv Card Electrophysiol
, vol.24
, pp. 53-61
-
-
Santini, M.1
Ricci, R.P.2
Lunati, M.3
-
15
-
-
77951176996
-
Remote monitoring of implantable cardioverter defibrillators versus quarterly device interrogations in clinic: Results from a randomized pilot clinical trial
-
Al-Khatib SM, Piccini JP, Knight D, et al. Remote monitoring of implantable cardioverter defibrillators versus quarterly device interrogations in clinic: results from a randomized pilot clinical trial. J Cardiovasc Electrophysiol 2010;21:545-50.
-
(2010)
J Cardiovasc Electrophysiol
, vol.21
, pp. 545-550
-
-
Al-Khatib, S.M.1
Piccini, J.P.2
Knight, D.3
-
16
-
-
52949146708
-
Remote monitoring of implantable cardioverter defibrillator patients: A safe, time-saving, and cost-effective means for follow-up
-
Raatikainen MJ, Uusimaa P, van Ginneken MM, et al. Remote monitoring of implantable cardioverter defibrillator patients: a safe, time-saving, and cost-effective means for follow-up. Europace 2008;10:1145-51.
-
(2008)
Europace
, vol.10
, pp. 1145-1151
-
-
Raatikainen, M.J.1
Uusimaa, P.2
Van Ginneken, M.M.3
-
17
-
-
57149089288
-
Optimized post-operative surveillance of permanent pacemakers by home monitoring: The OEDIPE trial
-
Halimi F, Clementy J, Attuel P, et al. Optimized post-operative surveillance of permanent pacemakers by home monitoring: the OEDIPE trial. Europace 2008;10:1392-9.
-
(2008)
Europace
, vol.10
, pp. 1392-1399
-
-
Halimi, F.1
Clementy, J.2
Attuel, P.3
-
18
-
-
44649168555
-
A prospective multicenter comparison trial of home monitoring against regular follow-up in MADIT II patients: Additional visits and cost impact
-
Elsner CH, Sommer P, Piorkowski C, et al. A prospective multicenter comparison trial of home monitoring against regular follow-up in MADIT II patients: additional visits and cost impact. Computers in Cardiology 2006;33:241-4.
-
(2006)
Computers in Cardiology
, vol.33
, pp. 241-244
-
-
Elsner, C.H.1
Sommer, P.2
Piorkowski, C.3
-
19
-
-
79952312933
-
The CONNECT (Clinical Evaluation of Remote Notification to Reduce Time to Clinical Decision) trial: The value of wireless remote monitoring with automatic clinician alerts
-
CONNECT Investigators
-
Crossley GH, Boyle A, Vitense H, et al. CONNECT Investigators. The CONNECT (Clinical Evaluation of Remote Notification to Reduce Time to Clinical Decision) trial: the value of wireless remote monitoring with automatic clinician alerts. J Am Coll Cardiol. 2011;57:1181-9.
-
(2011)
J Am Coll Cardiol
, vol.57
, pp. 1181-1189
-
-
Crossley, G.H.1
Boyle, A.2
Vitense, H.3
-
20
-
-
58149099012
-
Remote control of implanted devices through home monitoring technology improves detection and clinical management of atrial fibrillation
-
Ricci RP, Morichelli L, Santini M. Remote control of implanted devices through home monitoring technology improves detection and clinical management of atrial fibrillation. Europace 2009;11:54-61.
-
(2009)
Europace
, vol.11
, pp. 54-61
-
-
Ricci, R.P.1
Morichelli, L.2
Santini, M.3
-
21
-
-
70350604076
-
Home monitoring in patients with implantable cardiac devices: Is there a potential reduction of stroke risk? Results from a computer model tested through Monte Carlo simulations
-
Based on theoretical extension of empirical data, remote monitoring has the potential to reduce atrial fibrillation related stroke risk in device patients not taking anticoagulation
-
Ricci RP, Morichelli L, Gargaro A, et al. Home monitoring in patients with implantable cardiac devices: is there a potential reduction of stroke risk? Results from a computer model tested through Monte Carlo simulations. J Cardiovasc Electrophysiol 2009;20:1244-51. Based on theoretical extension of empirical data, remote monitoring has the potential to reduce atrial fibrillation related stroke risk in device patients not taking anticoagulation.
-
(2009)
J Cardiovasc Electrophysiol
, vol.20
, pp. 1244-1251
-
-
Ricci, R.P.1
Morichelli, L.2
Gargaro, A.3
-
22
-
-
70350014890
-
A meta-analysis of remote monitoring of heart failure patients
-
Meta-analysis of 20 trials and 12 cohort studies, indicating mortality and hospitalisation benefit of remote monitoring in heart failure patients. Requires prospective confirmation
-
Klersy C, De Silvestri A, Gabutti G, et al. A meta-analysis of remote monitoring of heart failure patients. J Am Coll Cardiol 2009;54:1683-94. Meta-analysis of 20 trials and 12 cohort studies, indicating mortality and hospitalisation benefit of remote monitoring in heart failure patients. Requires prospective confirmation.
-
(2009)
J Am Coll Cardiol
, vol.54
, pp. 1683-1694
-
-
Klersy, C.1
De Silvestri, A.2
Gabutti, G.3
-
23
-
-
44649140938
-
Automatic home monitoring of implantable cardioverter defibrillators
-
DOI 10.1093/europace/eun099
-
Nielsen JC, Kottkamp H, Zabel M, et al. Automatic home monitoring of implantable cardioverter defibrillators. Europace 2008;10:729-35. (Pubitemid 351775275)
-
(2008)
Europace
, vol.10
, Issue.6
, pp. 729-735
-
-
Nielsen, J.C.1
Kottkamp, H.2
Zabel, M.3
Aliot, E.4
Kreutzer, U.5
Bauer, A.6
Schuchert, A.7
Neuser, H.8
Schumacher, B.9
Schmidinger, H.10
Stix, G.11
Clementy, J.12
Danilovic, D.13
Hindricks, G.14
-
24
-
-
60849098171
-
Analysis of 57,148 transmissions by remote monitoring of implantable cardioverter defibrillators
-
Theuns DA, Rivero-Ayerza M, Knops P, et al. Analysis of 57,148 transmissions by remote monitoring of implantable cardioverter defibrillators. Pacing Clin Electrophysiol 2009;32(Suppl 1): S63-5.
-
(2009)
Pacing Clin Electrophysiol
, vol.32
, Issue.SUPPL. 1
-
-
Theuns, D.A.1
Rivero-Ayerza, M.2
Knops, P.3
-
25
-
-
79955624076
-
The logistics of remote monitoring: A time and work analysis
-
Ching E. The logistics of remote monitoring: a time and work analysis. Heart Rhythm 2010;(Suppl):S3.
-
(2010)
Heart Rhythm
, vol.3
, Issue.SUPPL.
-
-
Ching, E.1
|