메뉴 건너뛰기




Volumn 5, Issue 2, 2011, Pages 179-188

Feasibility of neural stimulation with floating-light-activated microelectrical stimulators

Author keywords

Neural microstimulation; wireless microstimulators

Indexed keywords

BRAIN CORTEX; CENTRAL NERVOUS SYSTEMS; CIRCULAR LASER BEAMS; COMPUTER MODELS; DEVICE SIZES; FREE PARAMETERS; GRAY MATTER; LASER POWER; MICROELECTRODE ARRAY; MICROSTIMULATION; MICROSTIMULATORS; NEAR-INFRARED WAVELENGTH; NEURAL ACTIVATION; NEURAL PROSTHETIC; NEURAL STIMULATIONS; NEURAL TISSUE; OUTPUT VOLTAGES; PHOTON DENSITIES; SPINAL CORDS; SUBMILLIMETERS; TEMPERATURE ELEVATION; WHITE MATTER;

EID: 79955864982     PISSN: 19324545     EISSN: None     Source Type: Journal    
DOI: 10.1109/TBCAS.2011.2114882     Document Type: Conference Paper
Times cited : (15)

References (43)
  • 1
    • 0029964253 scopus 로고    scopus 로고
    • Feasibility of a visual prosthesis for the blind based on intracortical microstimulation of the visual cortex
    • E. M. Schmidt, M. J. Bak, F. T. Hambrecht, C. V. Kufta, D. K. O'Rourke, and P. Vallabhanath, "Feasibility of a visual prosthesis for the blind based on intracortical microstimulation of the visual cortex," Brain, vol. 119, pp. 507-522, 1996. (Pubitemid 26149365)
    • (1996) Brain , vol.119 , Issue.2 , pp. 507-522
    • Schmidt, E.M.1    Bak, M.J.2    Hambrecht, F.T.3    Kufta, C.V.4    O'Rourke, D.K.5    Vallabhanath, P.6
  • 4
    • 0141448980 scopus 로고    scopus 로고
    • Multi-joint movement of the cat hindlimb evoked by microstimulation of the lumbosacral spinal cord
    • DOI 10.1016/S0014-4886(03)00210-3
    • C. Tai, A. M. Booth, C. J. Robinson, W.C. De Groat, and J. R. Roppolo, "Multi-joint movement of the cat hindlimb evoked by microstimulation of the lumbosacral spinal cord," Exper. Neurol., vol. 183, pp. 620-627, 2003. (Pubitemid 37205104)
    • (2003) Experimental Neurology , vol.183 , Issue.2 , pp. 620-627
    • Tai, C.1    Booth, A.M.2    Robinson, C.J.3    De Groat, W.C.4    Roppolo, J.R.5
  • 5
    • 27744586837 scopus 로고    scopus 로고
    • Microstimulation in auditory cortex provides a substrate for detailed behaviors
    • DOI 10.1016/j.heares.2005.08.004, PII S0378595505002467
    • K. J. Otto, P. J. Rousche, and D. R. Kipke, "Microstimulation in auditory cortex provides a substrate for detailed behaviors," Hear. Res., vol. 210, pp. 112-117, 2005. (Pubitemid 41628137)
    • (2005) Hearing Research , vol.210 , Issue.1-2 , pp. 112-117
    • Otto, K.J.1    Rousche, P.J.2    Kipke, D.R.3
  • 7
    • 0032125652 scopus 로고    scopus 로고
    • Chronic recording capability of the utah intracortical electrode array in cat sensory cortex
    • DOI 10.1016/S0165-0270(98)00031-4, PII S0165027098000314
    • P. J. Rousche and R. A. Normann, "Chronic recording capability of the utah intracortical electrode array in cat sensory cortex," J. Neurosci. Meth., vol. 82, pp. 1-15, 1998. (Pubitemid 28335467)
    • (1998) Journal of Neuroscience Methods , vol.82 , Issue.1 , pp. 1-15
    • Rousche, P.J.1    Normann, R.A.2
  • 10
    • 70449697992 scopus 로고    scopus 로고
    • Implanted neural electrodes cause chronic, local inflammation that is correlated with local neurodegeneration
    • 056003
    • G. C. McConnell, H. D. Rees,A.I.Levey,C. A. Gutekunst,R. E. Gross, and R. V. Bellamkonda, "Implanted neural electrodes cause chronic, local inflammation that is correlated with local neurodegeneration," J. Neural. Eng., vol. 6, no. 056003, 2009.
    • (2009) J. Neural. Eng. , vol.6
    • McConnell, G.C.1    Rees, H.D.2    Levey, A.I.3    Gutekunst, C.A.4    Gross, R.E.5    Bellamkonda, R.V.6
  • 11
    • 34250177246 scopus 로고    scopus 로고
    • The brain tissue response to implanted silicon microelectrode arrays is increased when the device is tethered to the skull
    • DOI 10.1002/jbm.a.31138
    • R. Biran, D. C. Martin, and P. A. Tresco, "The brain tissue response to implanted silicon microelectrode arrays is increased when the device is tethered to the skull," J. Biomed. Mater. Res. A, vol. 82, pp. 169-178, 2007. (Pubitemid 46906503)
    • (2007) Journal of Biomedical Materials Research - Part A , vol.82 , Issue.1 , pp. 169-178
    • Biran, R.1    Martin, D.C.2    Tresco, P.A.3
  • 14
    • 79955839992 scopus 로고    scopus 로고
    • Floating micro-fabricated wireless neuro-stimulators
    • presented at the Los Angeles, CA
    • A. C. Wu, P. S. Spuhler, M. S. Unlu, and M. Sahin, "Floating micro-fabricated wireless neuro-stimulators," presented at the Annu. Meeting Biomed. Eng. Soc., Los Angeles, CA, 2007.
    • (2007) Annu. Meeting Biomed. Eng. Soc.
    • Wu, A.C.1    Spuhler, P.S.2    Unlu, M.S.3    Sahin, M.4
  • 16
    • 0026969014 scopus 로고
    • Modeling the effects of electric fields on nerve fibers: Determination of excitation thresholds
    • DOI 10.1109/10.184700
    • E. N. Warman, W. M. Grill, and D. Durand, "Modeling the effects of electric fields on nerve fibers: Determination of excitation thresholds," IEEE Trans. Biomed. Eng., vol. 39, no. 12, pp. 1244-1254, Dec. 1992. (Pubitemid 23127282)
    • (1992) IEEE Transactions on Biomedical Engineering , vol.39 , Issue.12 , pp. 1244-1254
    • Warman, E.N.1    Grill, W.M.2    Durand, D.3
  • 17
    • 0029045693 scopus 로고
    • MCML-Monte Carlo modeling of photon transport in multilayered tissues
    • [Online]
    • L.-H. Wang, S. L. Jacques, and L. Q, Zheng, "MCML-Monte Carlo modeling of photon transport in multilayered tissues," Comput. Meth. Programs Biomed., vol. 47, pp. 131-146, 1995. [Online]. Available: http://labs.seas.wustl.edu/bme/Wang/mc.html
    • (1995) Comput. Meth. Programs Biomed. , vol.47 , pp. 131-146
    • Wang, L.-H.1    Jacques, S.L.2    Zheng, L.Q.3
  • 18
    • 33645536532 scopus 로고    scopus 로고
    • In vitro determination of normal and neoplastic human brain tissue optical properties using inverse adding-doubling
    • S. C. Gebhart, W. C. Lin, and A. Mahadevan-Jansen, "In vitro determination of normal and neoplastic human brain tissue optical properties using inverse adding-doubling," Phys. Med. Biol., vol. 51, pp. 2011-2027, 2006.
    • (2006) Phys. Med. Biol. , vol.51 , pp. 2011-2027
    • Gebhart, S.C.1    Lin, W.C.2    Mahadevan-Jansen, A.3
  • 19
    • 22744433002 scopus 로고    scopus 로고
    • Determination of reduced scattering coefficient of biological tissue from a needle-like probe
    • DOI 10.1364/OPEX.13.004828
    • M. Johns, C. A. Giller, D. C. German, and H. Liu, "Determination of reduced scattering coefficient of biological tissue from a needle-like probe," Opt. Expr., vol. 13, pp. 4828-4842, 2005. (Pubitemid 41029317)
    • (2005) Optics Express , vol.13 , Issue.13 , pp. 4828-4842
    • Johns, M.1    Giller, C.A.2    German, D.C.3    Liu, H.4
  • 20
    • 34247188127 scopus 로고    scopus 로고
    • Electromagnetic power absorption and temperature changes due to brain machine interface operation
    • DOI 10.1007/s10439-007-9264-3
    • T. S. Ibrahim, D. Abraham, and R. L. Rennaker, "Electromagnetic power absorption and temperature changes due to brain machine interface operation," Ann. Biomed. Eng., vol. 35, pp. 825-834, 2007. (Pubitemid 46626143)
    • (2007) Annals of Biomedical Engineering , vol.35 , Issue.5 , pp. 825-834
    • Ibrahim, T.S.1    Abraham, D.2    Rennaker, R.L.3
  • 22
    • 0038376267 scopus 로고    scopus 로고
    • Hyperthermia induced pathophysiology of the central nervous system
    • DOI 10.1080/0265673021000054621
    • H. S. Sharma and P. J. Hoopes, "Hyperthermia induced pathophysi-ology of the central nervous system," Int. J. Hyperthermia, vol. 19, pp. 325-354, 2003. (Pubitemid 36740801)
    • (2003) International Journal of Hyperthermia , vol.19 , Issue.3 , pp. 325-354
    • Sharma, H.S.1    Hoopes, P.J.2
  • 23
    • 14744269095 scopus 로고    scopus 로고
    • Investigation of electrochemical behavior of stimulation/sensing materials for pacemaker electrode applications I. Pt, Ti, and TIN coated electrodes
    • DOI 10.1149/1.1842092
    • A. Norlin, J. Pan, and C. Leygraf, "Investigation of electrochemical behavior of stimulation/sensing materials for pacemaker electrode applications I. Pt, Ti, and TIN coated electrodes," J. Electrochem. Soc., vol. 152, pp. J7-J15, 2005. (Pubitemid 40325860)
    • (2005) Journal of the Electrochemical Society , vol.152 , Issue.2
    • Norlin, A.1    Pan, J.2    Leygraf, C.3
  • 24
    • 1542271385 scopus 로고    scopus 로고
    • Electrochemical characterization of titanium nitride microelectrode arrays for charge-injection applications
    • D. M. Zhou and R. J. Greenberg, "Electrochemical characterization of titanium nitride microelectrode arrays for charge-injection applications," in Proc. IEEE Annu. Int. Conf. Engineering Medicine and Biology, 2003, pp. 1964-1967.
    • (2003) Proc. IEEE Annu. Int. Conf. Engineering Medicine and Biology , pp. 1964-1967
    • Zhou, D.M.1    Greenberg, R.J.2
  • 25
    • 31544446633 scopus 로고    scopus 로고
    • Potential-biased, asymmetric waveforms for charge-injection with activated iridium oxide (AIROF) neural stimulation electrodes
    • DOI 10.1109/TBME.2005.862572
    • S. F. Cogan, P. R. Troyk, J. Ehrlich, T. D. Plante, and D. E. Detlefsen, "Potential-biased, asymmetric waveforms for charge- injection with activated iridium oxide (AIROF) neural stimulation electrodes," IEEE Trans. Biomed. Eng., vol. 53, no. 2, pp. 327-332, Feb. 2006. (Pubitemid 43162421)
    • (2006) IEEE Transactions on Biomedical Engineering , vol.53 , Issue.2 , pp. 327-332
    • Cogan, S.F.1    Troyk, P.R.2    Ehrlich, J.3    Plante, T.D.4    Detlefsen, D.E.5
  • 26
  • 27
    • 33644682142 scopus 로고    scopus 로고
    • Chronic neural recordings using silicon microelectrode arrays electrochemically deposited with a poly(3,4-ethylenedioxythiophene) (PEDOT) film
    • DOI 10.1088/1741-2560/3/1/007, PII S1741256006129122
    • K. A. Ludwig, J. D. Uram, J. Yang, D. C. Martin, and D. R. Kipke, "Chronic neural recordings using silicon microelectrode arrays elec-trochemically deposited with a poly(3,4-ethylenedioxythiophene) (PEDOT) film," J. Neural Eng., vol. 3, pp. 59-70, 2006. (Pubitemid 43332372)
    • (2006) Journal of Neural Engineering , vol.3 , Issue.1 , pp. 59-70
    • Ludwig, K.A.1    Uram, J.D.2    Yang, J.3    Martin, D.C.4    Kipke, D.R.5
  • 28
    • 0020332065 scopus 로고
    • Analysis and control of the current distribution under circular dispersive electrodes
    • J. D. Wiley and J. G. Webster May
    • J. D. Wiley and J. G. Webster, "Analysis and control of the current distribution under circular dispersive electrodes," IEEE Trans. Biomed. Eng., vol. BME-29, no. 5, pp. 381-385, May 1982.
    • (1982) IEEE Trans. Biomed. Eng. , vol.BME-29 , Issue.5 , pp. 381-385
  • 29
    • 0000329160 scopus 로고
    • Specific impedance of rabbit cerebral cortex
    • J. B. Ranck Jr., "Specific impedance of rabbit cerebral cortex," Exp. Neurol., vol. 7, pp. 144-152, 1963.
    • (1963) Exp. Neurol. , vol.7 , pp. 144-152
    • Ranck Jr., J.B.1
  • 30
    • 0012183991 scopus 로고
    • The specific impedance of the dorsal columns of the cat: An anisotropic medium
    • J. B. Ranck Jr. and S. L. BeMent, "The specific impedance of the dorsal columns of the cat: An anisotropic medium," Exp. Neurol., vol. 11, pp. 451-463, 1965.
    • (1965) Exp. Neurol. , vol.11 , pp. 451-463
    • Ranck Jr., J.B.1    Bement, S.L.2
  • 31
    • 0029980895 scopus 로고    scopus 로고
    • Morphologic features of the normal human cadaveric spinal cord
    • DOI 10.1097/00007632-199606010-00001
    • T. Kameyama, Y. Hashizume, and G. Sobue, "Morphologic features of the normal human cadaveric spinal cord," Spine, vol. 21, pp. 1285-1290, 1996. (Pubitemid 26169501)
    • (1996) Spine , vol.21 , Issue.11 , pp. 1285-1290
    • Kameyama, T.1    Hashizume, Y.2    Sobue, G.3
  • 32
    • 0028021733 scopus 로고
    • Age-related changes of the myelinated fibers in the human corticospinal tract: A quantitative analysis
    • DOI 10.1007/s004010050141
    • S. I. Terao, G. Sobue, Y. Hashizume, N. Shimada, and T. Mitsuma, "Age-related changes of the myelinated fibers in the human corti-cospinal tract: A quantitative analysis," Acta Neuropathologica, vol. 88, pp. 137-142, 1994. (Pubitemid 24233244)
    • (1994) Acta Neuropathologica , vol.88 , Issue.2 , pp. 137-142
    • Terao, S.-I.1    Sobue, G.2    Hashizume, Y.3    Shimada, N.4    Mitsuma, T.5
  • 34
    • 33847611213 scopus 로고    scopus 로고
    • Retinal charge sensitivity and spatial discrimination obtainable by subretinal implants: Key lessons learned from isolated chicken retina
    • DOI 10.1088/1741-2560/4/1/S02, PII S1741256007345151, S02
    • A. Stett, A. Mai, and T. Herrmann, "Retinal charge sensitivity and spatial discrimination obtainable by subretinal implants: Key lessons learned from isolated chicken retina," J. Neural Eng., vol. 4, pp. S7-S16, 2007. (Pubitemid 46357443)
    • (2007) Journal of Neural Engineering , vol.4 , Issue.1
    • Stett, A.1    Mai, A.2    Herrmann, T.3
  • 35
    • 4244040119 scopus 로고    scopus 로고
    • Electrical stimulation pulse-width determines the target cell in the frog and human retina
    • R. J. Greenberg, "Electrical stimulation pulse-width determines the target cell in the frog and human retina," Investigat. Ophthalmol. Vis. Sci., vol. 38, p. S40, 1997.
    • (1997) Investigat. Ophthalmol. Vis. Sci. , vol.38
    • Greenberg, R.J.1
  • 36
    • 22044458583 scopus 로고    scopus 로고
    • Design of a high-resolution optoelectronic retinal prosthesis
    • DOI 10.1088/1741-2560/2/1/012
    • D. Palanker, A. Vankov, P. Huie, and S. Baccus, "Design of a high-resolution optoelectronic retinal prosthesis," J. Neural Eng., vol. 2, pp. S105-S120, 2005. (Pubitemid 41238014)
    • (2005) Journal of Neural Engineering , vol.2 , Issue.1
    • Palanker, D.1    Vankov, A.2    Huie, P.3    Baccus, S.4
  • 37
    • 31544432573 scopus 로고    scopus 로고
    • Microfabricated cylindrical multielectrodes for neural stimulation
    • DOI 10.1109/TBME.2005.862552
    • S. Snow, S. C. Jacobsen, D. L. Wells, and K. W. Horch, "Microfabri-cated cylindrical multielectrodes for neural stimulation," IEEE Trans. Biomedical Eng., vol. 53, no. 2, pp. 320-326, Feb. 2006. (Pubitemid 43162420)
    • (2006) IEEE Transactions on Biomedical Engineering , vol.53 , Issue.2 , pp. 320-326
    • Snow, S.1    Jacobsen, S.C.2    Wells, D.L.3    Horch, K.W.4
  • 38
    • 33846037799 scopus 로고    scopus 로고
    • Bio-heat transfer model of deep brain stimulation-induced temperature changes
    • M. M. Elwassif, Q. Kong, M. Vazquez, and M. Bikson, "Bio-heat transfer model of deep brain stimulation-induced temperature changes," J. Neural Eng., vol. 3, no. 008, 2006.
    • (2006) J. Neural Eng. , vol.3 , Issue.8
    • Elwassif, M.M.1    Kong, Q.2    Vazquez, M.3    Bikson, M.4
  • 39
    • 0029395028 scopus 로고
    • On the influence of volume currents and extended sources on neuromagnetic fields: A simulation study
    • J. Haueisen, C. Ramon, P. Czapski, and M. Eiselt, "On the influence of volume currents and extended sources on neuromagnetic fields: A simulation study," Ann. Biomed. Eng., vol. 23, pp. 728-739, 1995.
    • (1995) Ann. Biomed. Eng. , vol.23 , pp. 728-739
    • Haueisen, J.1    Ramon, C.2    Czapski, P.3    Eiselt, M.4
  • 42
    • 0036132495 scopus 로고    scopus 로고
    • Biostability of micro-photodiode arrays for subretinal implantation
    • DOI 10.1016/S0142-9612(01)00185-5, PII S0142961201001855
    • H. Hammerle, K. Kobuch, K. Kohler, W. Nisch, H. Sachs, and M. Stelzle, "Biostabilityof micro-photodiode arrays for subretinal implantation," Biomaterials, vol. 23, pp. 797-804, 2002. (Pubitemid 33108954)
    • (2002) Biomaterials , vol.23 , Issue.3 , pp. 797-804
    • Hammerle, H.1    Kobuch, K.2    Kohler, K.3    Nisch, W.4    Sachs, H.5    Stelzle, M.6
  • 43
    • 3242706023 scopus 로고    scopus 로고
    • Thermal elevation in the human eye and head due to the operation of a retinal prosthesis
    • DOI 10.1109/TBME.2004.827548
    • K.Gosalia, J. Weiland, M. Humayun, and G. Lazzi, "Thermal elevation in the human eye and head due to the operation of a retinal prosthesis," IEEE Trans. Biomed. Eng., vol. 51, no. 8, pp. 1469-1477, Aug. 2004. (Pubitemid 38955171)
    • (2004) IEEE Transactions on Biomedical Engineering , vol.51 , Issue.8 , pp. 1469-1477
    • Gosalia, K.1    Weiland, J.2    Humayun, M.3    Lazzi, G.4