메뉴 건너뛰기




Volumn 27, Issue 5, 2011, Pages 398-402

A randomized comparison of the glidescope videolaryngoscope to the standard laryngoscopy for intubation by pediatric residents in simulated easy and difficult infant airway scenarios

Author keywords

difficult airway; patient safety; residents; simulation; tracheal intubation; videolaryngoscopy

Indexed keywords

ADULT; AIRWAY; ARTICLE; AUDIOVISUAL EQUIPMENT; COMPARATIVE EFFECTIVENESS; CONTROLLED STUDY; DEVICE SAFETY; ENDOSCOPY; ENDOTRACHEAL INTUBATION; HUMAN; HYPOPHARYNX; LARYNGOSCOPE; LARYNGOSCOPY; LARYNX; PATIENT SAFETY; PEDIATRIC ADVANCED LIFE SUPPORT; RANDOMIZED CONTROLLED TRIAL; RANDOMIZED CONTROLLED TRIAL (TOPIC); RESIDENT; SIMULATOR; TEACHING; TONGUE EDEMA; VIDEOLARYNGOSCOPY;

EID: 79955864494     PISSN: 07495161     EISSN: None     Source Type: Journal    
DOI: 10.1097/PEC.0b013e318217b550     Document Type: Article
Times cited : (50)

References (30)
  • 1
    • 66949125080 scopus 로고    scopus 로고
    • Comparison of the Glidescope and Pentax AWS laryngoscopes to the Macintosh laryngoscope for use by advanced paramedics in easy and simulated difficult intubation
    • Nasim S, Maharaj CH, Malik MA, et al. Comparison of the Glidescope and Pentax AWS laryngoscopes to the Macintosh laryngoscope for use by advanced paramedics in easy and simulated difficult intubation. BMC Emerg Med. 2009;9:9.
    • (2009) BMC Emerg Med , vol.9 , pp. 9
    • Nasim, S.1    Maharaj, C.H.2    Malik, M.A.3
  • 2
    • 36349028035 scopus 로고    scopus 로고
    • Resident exposure to critical patients in a pediatric emergency department
    • DOI 10.1097/PEC.0b013e318159ffef, PII 0000656520071100000002
    • Chen EH, Cho CS, Shofer FS, et al. Resident exposure to critical patients in a pediatric emergency department. Pediatr Emerg Care. 2007;23:774-778. (Pubitemid 350145268)
    • (2007) Pediatric Emergency Care , vol.23 , Issue.11 , pp. 774-778
    • Chen, E.H.1    Cho, C.S.2    Shofer, F.S.3    Mills, A.M.4    Baren, J.M.5
  • 3
    • 46249119466 scopus 로고    scopus 로고
    • Tracheal intubation practice and maintaining skill competency: Survey of pediatric emergency department medical directors
    • Losek JD, Olson LR, Dobson JV, et al. Tracheal intubation practice and maintaining skill competency: survey of pediatric emergency department medical directors. Pediatr Emerg Care. 2008;24:294-299.
    • (2008) Pediatr Emerg Care , vol.24 , pp. 294-299
    • Losek, J.D.1    Olson, L.R.2    Dobson, J.V.3
  • 4
    • 67149098953 scopus 로고    scopus 로고
    • Survey of pediatric resident experiences with resuscitation training and attendance at actual cardiopulmonary arrests
    • Hunt EA, Patel S, Vera K, et al. Survey of pediatric resident experiences with resuscitation training and attendance at actual cardiopulmonary arrests. Pediatr Crit Care Med. 2009;10:96-105.
    • (2009) Pediatr Crit Care Med , vol.10 , pp. 96-105
    • Hunt, E.A.1    Patel, S.2    Vera, K.3
  • 5
    • 15944397631 scopus 로고    scopus 로고
    • The GlideScope video laryngoscope
    • Doyle DJ. The GlideScope video laryngoscope. Anaesthesia. 2005;60:414-415.
    • (2005) Anaesthesia , vol.60 , pp. 414-415
    • Doyle, D.J.1
  • 6
    • 65549087053 scopus 로고    scopus 로고
    • Video and optic laryngoscopy assisted tracheal intubationVthe new era
    • Thong SY, Lim Y. Video and optic laryngoscopy assisted tracheal intubationVthe new era. Anaesth Intensive Care. 2009;37:219-233.
    • (2009) Anaesth Intensive Care , vol.37 , pp. 219-233
    • Thong, S.Y.1    Lim, Y.2
  • 9
    • 61749085340 scopus 로고    scopus 로고
    • Comparison of the Glidescope and Airtraq optical laryngoscopes in patients undergoing direct microlaryngoscopy
    • Lange M, Frommer M, Redel A, et al. Comparison of the Glidescope and Airtraq optical laryngoscopes in patients undergoing direct microlaryngoscopy. Anaesthesia. 2009;64:323-328.
    • (2009) Anaesthesia , vol.64 , pp. 323-328
    • Lange, M.1    Frommer, M.2    Redel, A.3
  • 10
    • 33646348998 scopus 로고    scopus 로고
    • The GlideScope® video laryngoscope: Initial experience in five neonates [5]
    • Trevisanuto D, Fornaro E, Verghese C. The GlideScope video laryngoscope: initial experience in five neonates. Can J Anaesth. 2006;53:423-424. (Pubitemid 43670559)
    • (2006) Canadian Journal of Anesthesia , vol.53 , Issue.4 , pp. 423-424
    • Trevisanuto, D.1    Fornaro, E.2    Verghese, C.3
  • 11
    • 67149116779 scopus 로고    scopus 로고
    • Validation of the GlideScope video laryngoscope in pediatric patients
    • Redel A, Karademir F, Schlitterlau A, et al. Validation of the GlideScope video laryngoscope in pediatric patients. Paediatr Anaesth. 2009;19:667-671.
    • (2009) Paediatr Anaesth , vol.19 , pp. 667-671
    • Redel, A.1    Karademir, F.2    Schlitterlau, A.3
  • 12
    • 51849124729 scopus 로고    scopus 로고
    • GlideScope video laryngoscope: A randomized clinical trial in 203 patients
    • Kim JT, Na HS, Bae JY, et al. GlideScope video laryngoscope: a randomized clinical trial in 203 patients. Br J Anaesth. 2008;101:531-534.
    • (2008) Br J Anaesth , vol.101 , pp. 531-534
    • Kim, J.T.1    Na, H.S.2    Bae, J.Y.3
  • 13
    • 68849098376 scopus 로고    scopus 로고
    • Facilitating endotracheal intubation using the GlideScope video laryngoscope in children with difficult airways
    • Xue FS, Liu HP, Liu JH, et al. Facilitating endotracheal intubation using the GlideScope video laryngoscope in children with difficult airways. Paediatr Anaesth. 2009;19(9):918-919.
    • (2009) Paediatr Anaesth , vol.19 , Issue.9 , pp. 918-919
    • Xue, F.S.1    Liu, H.P.2    Liu, J.H.3
  • 14
    • 34247329725 scopus 로고    scopus 로고
    • Airway management using the pediatric GlideScope® in a child with Goldenhar syndrome and atypical plasma cholinesterase
    • DOI 10.1111/j.1460-9592.2006.02149.x
    • Milne AD, Dower AM, Hackmann T. Airway management using the pediatric GlideScope in a child with Goldenhar syndrome and atypical plasma cholinesterase. Paediatr Anaesth. 2007;17(5):484-487. (Pubitemid 46633395)
    • (2007) Paediatric Anaesthesia , vol.17 , Issue.5 , pp. 484-487
    • Milne, A.D.1    Dower, A.M.2    Hackmann, T.3
  • 15
    • 67149146440 scopus 로고    scopus 로고
    • Use of GlideScope Ranger in the management of a child with Treacher Collins syndrome in a developing world setting
    • Bishop S, Clements P, Kale K, et al. Use of GlideScope Ranger in the management of a child with Treacher Collins syndrome in a developing world setting. Paediatr Anaesth. 2009; 19(7):695-696.
    • (2009) Paediatr Anaesth , vol.19 , Issue.7 , pp. 695-696
    • Bishop, S.1    Clements, P.2    Kale, K.3
  • 16
    • 67149120802 scopus 로고    scopus 로고
    • GlideScope for management of the difficult airway in a child with Beckwith-Wiedemann syndrome
    • Eaton J, Atiles R, Tuchman JB. GlideScope for management of the difficult airway in a child with Beckwith-Wiedemann syndrome. Paediatr Anaesth. 2009;19(7):696-698.
    • (2009) Paediatr Anaesth , vol.19 , Issue.7 , pp. 696-698
    • Eaton, J.1    Atiles, R.2    Tuchman, J.B.3
  • 17
    • 33846279743 scopus 로고    scopus 로고
    • High-fidelity medical simulation as an assessment tool for pediatric residents' airway management skills
    • DOI 10.1097/PEC.0b013e31802c61d5, PII 0000656520070100000003
    • Overly FL, Sudikoff SN, Shapiro MJ. High-fidelity medical simulation as an assessment tool for pediatric resident's airway management skills. Pediatr Emerg Care. 2007;23:11-15. (Pubitemid 46115344)
    • (2007) Pediatric Emergency Care , vol.23 , Issue.1 , pp. 11-15
    • Overly, F.L.1    Sudikoff, S.N.2    Shapiro, M.J.3
  • 18
    • 68849129139 scopus 로고    scopus 로고
    • Learning curves of the Glidescope, the McGrath and the Airtraq laryngoscopes: A manikin study
    • Savoldelli GL, Schiffer E, Abegg C, et al. Learning curves of the Glidescope, the McGrath and the Airtraq laryngoscopes: a manikin study. Eur J Anaesthesiol. 2009;26:554-558.
    • (2009) Eur J Anaesthesiol , vol.26 , pp. 554-558
    • Savoldelli, G.L.1    Schiffer, E.2    Abegg, C.3
  • 19
    • 49849085407 scopus 로고    scopus 로고
    • Supplemental oxygen compromises the use of pulse oximetry for detection of apnea and hypoventilation during sedation in simulated pediatric patients
    • Keidan I, Gravenstein D, Berkenstadt H, et al. Supplemental oxygen compromises the use of pulse oximetry for detection of apnea and hypoventilation during sedation in simulated pediatric patients. Pediatrics. 2008;122:293-298.
    • (2008) Pediatrics , vol.122 , pp. 293-298
    • Keidan, I.1    Gravenstein, D.2    Berkenstadt, H.3
  • 20
    • 47249157286 scopus 로고    scopus 로고
    • An analysis of candidate ethical justifications for allowing inexperienced physicians-in-training to perform invasive procedures
    • Mercurio MR. An analysis of candidate ethical justifications for allowing inexperienced physicians-in-training to perform invasive procedures. J Med Philos. 2008;33:44-57.
    • (2008) J Med Philos , vol.33 , pp. 44-57
    • Mercurio, M.R.1
  • 21
    • 64149083471 scopus 로고    scopus 로고
    • A simple fibreoptic assisted laryngoscope for difficult intubation: A manikin study
    • Komiya K, Inagawa G, Nakamura K, et al. A simple fibreoptic assisted laryngoscope for difficult intubation: a manikin study. Anaesthesia. 2009;64:425-429.
    • (2009) Anaesthesia , vol.64 , pp. 425-429
    • Komiya, K.1    Inagawa, G.2    Nakamura, K.3
  • 22
    • 59449095966 scopus 로고    scopus 로고
    • Ease of intubation with the GlideScope or Airway Scope by novice operators in simulated easy and difficult airwaysVa manikin study
    • Tan BH, Liu EH, Lim RT, et al. Ease of intubation with the GlideScope or Airway Scope by novice operators in simulated easy and difficult airwaysVa manikin study. Anaesthesia. 2009;64:187-190.
    • (2009) Anaesthesia , vol.64 , pp. 187-190
    • Tan, B.H.1    Liu, E.H.2    Lim, R.T.3
  • 23
    • 33646532277 scopus 로고    scopus 로고
    • An evaluation of the GlideScope, a new video laryngoscope for difficult airways: A manikin study
    • Benjamin FJ, Boon D, French RA. An evaluation of the GlideScope, a new video laryngoscope for difficult airways: a manikin study. Eur J Anaesthesiol. 2006;23:517-521.
    • (2006) Eur J Anaesthesiol , vol.23 , pp. 517-521
    • Benjamin, F.J.1    Boon, D.2    French, R.A.3
  • 24
    • 68849129824 scopus 로고    scopus 로고
    • Fibreoptic and videoscopic indirect intubation techniques for intubation in children
    • quiz 480-482
    • Levin R, Kissoon N, Froese N. Fibreoptic and videoscopic indirect intubation techniques for intubation in children. Pediatr Emerg Care. 2009;25(7):479; quiz 480-482.
    • (2009) Pediatr Emerg Care , vol.25 , Issue.7 , pp. 479
    • Levin, R.1    Kissoon, N.2    Froese, N.3
  • 25
    • 66149093148 scopus 로고    scopus 로고
    • Tracheal intubation in patients with cervical spine immobilization: A comparison of the Airwayscope, LMA CTrach and the Macintosh laryngoscopes
    • Malik MA, Subramaniam R, Churasia S, et al. Tracheal intubation in patients with cervical spine immobilization: a comparison of the Airwayscope, LMA CTrach and the Macintosh laryngoscopes. Br J Anaesth. 2009;102:654-661.
    • (2009) Br J Anaesth , vol.102 , pp. 654-661
    • Malik, M.A.1    Subramaniam, R.2    Churasia, S.3
  • 26
    • 54249167043 scopus 로고    scopus 로고
    • Comparison of Macintosh, Truview EVO2, Glidescope, and Airwayscope laryngoscope use in patients with cervical spine immobilization
    • Malik MA, Maharaj CH, Harte BH, et al. Comparison of Macintosh, Truview EVO2, Glidescope, and Airwayscope laryngoscope use in patients with cervical spine immobilization. Br J Anaesth. 2008;101:723-730.
    • (2008) Br J Anaesth , vol.101 , pp. 723-730
    • Malik, M.A.1    Maharaj, C.H.2    Harte, B.H.3
  • 27
    • 11444255353 scopus 로고    scopus 로고
    • The Glidescope® system: A clinical assessment of performance
    • DOI 10.1111/j.1365-2044.2004.04013.x
    • Rai MR, Dering A, Verghese C. The GlideScope system: a clinical assessment of performance. Anaesthesia. 2005;60:60-64. (Pubitemid 40081241)
    • (2005) Anaesthesia , vol.60 , Issue.1 , pp. 60-64
    • Rai, M.R.1    Dering, A.2    Verghese, C.3
  • 28
    • 70350198059 scopus 로고    scopus 로고
    • A comparison of the Glidescope, Pentax AWS, and Macintosh laryngoscopes when used by novice personnel: A manikin study
    • Malik MA, Hassett P, Carney J, et al. A comparison of the Glidescope, Pentax AWS, and Macintosh laryngoscopes when used by novice personnel: a manikin study. Can J Anaesth. 2009;56:802-811.
    • (2009) Can J Anaesth , vol.56 , pp. 802-811
    • Malik, M.A.1    Hassett, P.2    Carney, J.3
  • 29
    • 61749102401 scopus 로고    scopus 로고
    • The usefulness of the GlideScope video laryngoscope in the education of conventional tracheal intubation for the novice
    • You JS, Park S, Chung SP, et al. The usefulness of the GlideScope video laryngoscope in the education of conventional tracheal intubation for the novice. Emerg Med J. 2009;26(2):109-111.
    • (2009) Emerg Med J , vol.26 , Issue.2 , pp. 109-111
    • You, J.S.1    Park, S.2    Chung, S.P.3
  • 30
    • 40549096434 scopus 로고    scopus 로고
    • Unanticipated difficult airway management in anaesthetised patients: A prospective study of the effect of mannequin training on management strategies and skill retention
    • DOI 10.1111/j.1365-2044.2007.05353.x
    • Kuduvalli PM, Jervis A, Tighe SQ, et al. Unanticipated difficult airway management in anaesthetised patients: a prospective study of the effect of mannequin training on management strategies and skill retention. Anaesthesia. 2008;63:364-369. (Pubitemid 351365026)
    • (2008) Anaesthesia , vol.63 , Issue.4 , pp. 364-369
    • Kuduvalli, P.M.1    Jervis, A.2    Tighe, S.Q.M.3    Robin, N.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.