메뉴 건너뛰기




Volumn 11, Issue 5, 2011, Pages 432-439

An ex vivo exothermal and mechanical evaluation of two-solution bone cements in vertebroplasty

Author keywords

Bone cement; Osteoporosis; PMMA; Spine biomechanics; Vertebral compression fracture

Indexed keywords

BONE CEMENT; METHACRYLIC ACID; POLY(METHYMETHACRYLATE) MICROSPHERE; POLY(METHYMETHACRYLATE) NANOSPHERE; TWO SOLUTION BONE CEMENT; UNCLASSIFIED DRUG;

EID: 79955807330     PISSN: 15299430     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.spinee.2011.02.012     Document Type: Article
Times cited : (11)

References (29)
  • 1
    • 28244447728 scopus 로고    scopus 로고
    • Vertebroplasty and kyphoplasty: Filler materials
    • Lieberman IH, Togawa D, Kayannja MM. Vertebroplasty and kyphoplasty: filler materials. Spine J 2005;5:305S-16S.
    • (2005) Spine J , vol.5
    • Lieberman, I.H.1    Togawa, D.2    Kayannja, M.M.3
  • 2
    • 31644450910 scopus 로고    scopus 로고
    • Injectable bone cements for use in vertebroplasty and kyphoplasty: State-of-the-art review
    • DOI 10.1002/jbm.b.30398
    • Lewis G. Injectable bone cements for use in vertebroplasty and kyphoplasty: state-of-the-art review. J Biomed Mater Res B Appl Biomater 2006;76B:456-68. (Pubitemid 43168280)
    • (2006) Journal of Biomedical Materials Research - Part B Applied Biomaterials , vol.76 , Issue.2 , pp. 456-468
    • Lewis, G.1
  • 3
    • 22844444704 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty: Indications, contraindications, technique, and complications
    • DOI 10.1080/02841850510021049
    • Guglielmi G, Andreula C, Muto M, Gilula LA. Percutaneous vertebroplasty: indications, contraindications, technique and complications. Acta Radiol 2005;3:256-68. (Pubitemid 41663614)
    • (2005) Acta Radiologica , vol.46 , Issue.3 , pp. 256-268
    • Guglielmi, G.1    Andreula, C.2    Muto, M.3    Gilula, L.A.4
  • 4
    • 33748086788 scopus 로고    scopus 로고
    • Vertebroplasty and kyphoplasty: A systematic review of 69 clinical studies
    • DOI 10.1097/01.brs.0000229254.89952.6b, PII 0000763220060801000018
    • Hulme PA, Krebs J, Ferguson SJ, Berlemann U. Vertebroplasty and kyphoplasty: a systematic review of 69 clinical studies. Spine 2006;3:1983-2001. (Pubitemid 44297781)
    • (2006) Spine , vol.31 , Issue.17 , pp. 1983-2001
    • Hulme, P.A.1    Krebs, J.2    Ferguson, S.J.3    Berlemann, U.4
  • 5
    • 27944446713 scopus 로고    scopus 로고
    • Vertebroplasty and kyphoplasty: A comprehensive review
    • Burton AW, Rhines LD, Mendel E. Vertebroplasty and kyphoplasty: a comprehensive review. Neurosurg Focus 2005;18:e1.
    • (2005) Neurosurg Focus , vol.18
    • Burton, A.W.1    Rhines, L.D.2    Mendel, E.3
  • 6
    • 33645089984 scopus 로고    scopus 로고
    • Histopathologic findings of retrieved specimens of vertebroplasty with polymethylmethacrylate cement: Case control study
    • Huang KY, Yan JJ, Lin RM. Histopathologic findings of retrieved specimens of vertebroplasty with polymethylmethacrylate cement: case control study. Spine 2005;30:E585-8.
    • (2005) Spine , vol.30
    • Huang, K.Y.1    Yan, J.J.2    Lin, R.M.3
  • 8
    • 0038638437 scopus 로고    scopus 로고
    • Temperature measurement during polymerization of polymethylmethacrylate cement used for vertebroplasty
    • DOI 10.1097/00007632-200307150-00015
    • Belkoff SM, Molloy S. Temperature measurement during polymerization of polymethylmethacrylate cement used for vertebroplasty. Spine 2003;28:1555-9. (Pubitemid 36877090)
    • (2003) Spine , vol.28 , Issue.14 , pp. 1555-1559
    • Belkoff, S.M.1    Molloy, S.2
  • 9
    • 64649086689 scopus 로고    scopus 로고
    • Kyphoplasty and vertebroplasty produce the same degree of height restoration
    • Hiwatashi A, Westesson PL-A, Yoshiura T, et al. Kyphoplasty and vertebroplasty produce the same degree of height restoration. AJNR Am J Neuroradiol 2009;30:669-73.
    • (2009) AJNR Am J Neuroradiol , vol.30 , pp. 669-673
    • Hiwatashi, A.1    Westesson, P.L.-A.2    Yoshiura, T.3
  • 10
    • 0032807670 scopus 로고    scopus 로고
    • Temperature elevation caused by bone cement polymerization during vertebroplasty
    • Deramond H, Wright NT, Belkoff SM. Temperature elevation caused by bone cement polymerization during vertebroplasty. Bone 1999;25:17-21.
    • (1999) Bone , vol.25 , pp. 17-21
    • Deramond, H.1    Wright, N.T.2    Belkoff, S.M.3
  • 11
  • 12
    • 0035879117 scopus 로고    scopus 로고
    • The biomechanics of vertebroplasty: The effect of cement volume on mechanical behavior
    • DOI 10.1097/00007632-200107150-00007
    • Belkoff SM, Mathis JM, Jasper LE, Deramond H. The biomechanics of vertebroplasty: the effect of cement volume on mechanical behavior. Spine 2001;26:1537-41. (Pubitemid 32646123)
    • (2001) Spine , vol.26 , Issue.14 , pp. 1537-1541
    • Belkoff, S.M.1    Mathis, J.M.2    Jasper, L.E.3    Deramond, H.4
  • 13
    • 0032803123 scopus 로고    scopus 로고
    • An in vitro biomechanical evaluation of bone cements used in percutaneous vertebroplasty
    • Belkoff SM, Maroney M, Fenton DC, Mathis JM. An in vitro biomechanical evaluation of bone cements used in percutaneous vertebroplasty. Bone 1999;25:23S-6S.
    • (1999) Bone , vol.25
    • Belkoff, S.M.1    Maroney, M.2    Fenton, D.C.3    Mathis, J.M.4
  • 14
    • 0035863342 scopus 로고    scopus 로고
    • An ex vivo biomechanical evaluation of an inflatable bone tamp used in the treatment of compression fracture
    • DOI 10.1097/00007632-200101150-00008
    • Belkoff SM, Mathis JM, Fenton DC, et al. An ex vivo biomechanical evaluation of an inflatable bone tamp used in the treatment of compression fractures. Spine 2001;26:151-6. (Pubitemid 32115605)
    • (2001) Spine , vol.26 , Issue.2 , pp. 151-156
    • Belkoff, S.M.1    Mathis, J.M.2    Fenton, D.C.3    Scribner, R.M.4    Reiley, M.E.5    Talmadge, K.6
  • 15
    • 0035879286 scopus 로고    scopus 로고
    • An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with vertebroplasty
    • DOI 10.1097/00007632-200107150-00008
    • Belkoff SM, Mathis JM, Jasper LE, Deramond H. An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with vertebroplasty. Spine 2001;26:1542-6. (Pubitemid 32646124)
    • (2001) Spine , vol.26 , Issue.14 , pp. 1542-1546
    • Belkoff, S.M.1    Mathis, J.M.2    Jasper, L.E.3    Deramond, H.4
  • 16
    • 4143140739 scopus 로고    scopus 로고
    • Bone cements: Review of their physiochemical and biochemical properties in percutaneous vertebroplasty
    • Provenzano MJ, Murphy KPJ, Riley LH III. Bone cements: review of their physiochemical and biochemical properties in percutaneous vertebroplasty. AJNR Am J Neuroradiol 2005;25:1286-90. (Pubitemid 39095184)
    • (2004) American Journal of Neuroradiology , vol.25 , Issue.7 , pp. 1286-1290
    • Provenzano, M.J.1    Murphy, K.P.J.2    Riley III, L.H.3
  • 17
    • 33644899683 scopus 로고    scopus 로고
    • Calcium phosphate cement-based vertebroplasty compared with conservative treatment for osteoporotic compression fractures: A matched case-control study
    • DOI 10.3171/spi.2006.4.2.110
    • Nakano M, Hirano N, Ishihara H, et al. Calcium phosphate cement-based vertebroplasty compared with conservative treatment for osteoporotic compression fractures: a matched case-control study. J Neurosurg Spine 2006;4:110-7. (Pubitemid 47325299)
    • (2006) Journal of Neurosurgery: Spine , vol.4 , Issue.2 , pp. 110-117
    • Nakano, M.1    Hirano, N.2    Ishihara, H.3    Kawaguchi, Y.4    Watanabe, H.5    Matsuura, K.6
  • 18
    • 0032802422 scopus 로고    scopus 로고
    • The effect of monomer-to-powder ratio on the material properties of cranioplastic
    • Jasper LE, Deramond H, Mathis JM, Belkoff SM. The effect of monomer-to-powder ratio on the material properties of cranioplastic. Bone 1999;25:27S-9S.
    • (1999) Bone , vol.25
    • Jasper, L.E.1    Deramond, H.2    Mathis, J.M.3    Belkoff, S.M.4
  • 19
    • 70049111371 scopus 로고    scopus 로고
    • Pseudoplasticity and setting properties of two-solution bone cement containing poly(methyl methacrylate) microspheres and nanospheres for kyphoplasty and vertebroplasty
    • Rodrigues DC, Gilbert JL, Hasenwinkel JM. Pseudoplasticity and setting properties of two-solution bone cement containing poly(methyl methacrylate) microspheres and nanospheres for kyphoplasty and vertebroplasty. J Biomed Mater Res B Appl Biomater 2009;91:248-56.
    • (2009) J Biomed Mater Res B Appl Biomater , vol.91 , pp. 248-256
    • Rodrigues, D.C.1    Gilbert, J.L.2    Hasenwinkel, J.M.3
  • 20
    • 74749103082 scopus 로고    scopus 로고
    • Two-solution bone cements with cross-linked micro and nano-particles for vertebral fracture applications: Effects of zirconium dioxide content on the material and setting properties
    • Rodrigues DC, Gilbert JL, Hasenwinkel JM. Two-solution bone cements with cross-linked micro and nano-particles for vertebral fracture applications: effects of zirconium dioxide content on the material and setting properties. J Biomed Mater Res B Appl Biomater 2010;92:13-23.
    • (2010) J Biomed Mater Res B Appl Biomater , vol.92 , pp. 13-23
    • Rodrigues, D.C.1    Gilbert, J.L.2    Hasenwinkel, J.M.3
  • 21
    • 0032764224 scopus 로고    scopus 로고
    • A novel high-viscosity, two-solution acrylic bone cement: Effect of chemical composition on properties
    • DOI 10.1002/(SICI)1097-4636(199910)47:1<36::AID-JBM5>3.0.CO;2-R
    • Hasenwinkel JM, Lautenschlager EP, Wixson RL, Gilbert JL. A novel high-viscosity, two-solution acrylic bone cement: effect of chemical composition on properties. J Biomed Mater Res 1999;47:36-45. (Pubitemid 29344967)
    • (1999) Journal of Biomedical Materials Research , vol.47 , Issue.1 , pp. 36-45
    • Hasenwinkel, J.M.1    Lautenschlager, E.P.2    Wixson, R.L.3    Gilbert, J.L.4
  • 22
    • 0037022694 scopus 로고    scopus 로고
    • Effect of initiation chemistry on the fracture toughness, fatigue, strength, and residual monomer content of a novel high-viscosity, two-solution acrylic bone cement
    • DOI 10.1002/jbm.1257
    • Hasenwinkel JM, Lautenschlager EP, Wixson RL, Gilbert JL. Effect of initiation chemistry on the fracture toughness, fatigue strength, and residual monomer content of a novel high-viscosity, two-solution acrylic bone cement. J Biomed Mater Res 2002;59:411-21. (Pubitemid 34037484)
    • (2002) Journal of Biomedical Materials Research , vol.59 , Issue.3 , pp. 411-421
    • Hasenwinkel, J.M.1    Lautenschlager, E.P.2    Wixson, R.L.3    Gilbert, J.L.4
  • 23
    • 0032618662 scopus 로고    scopus 로고
    • Quantification of interdigitation at bone cement/cancellous bone interfaces in cemented femoral reconstructions
    • Maher SA, McCormack BAO. Quantification of interdigitation at bone cement/cancellous bone interfaces in cemented femoral reconstructions. Proc Inst Mech Eng H 1999;213:347-54.
    • (1999) Proc Inst Mech Eng H , vol.213 , pp. 347-354
    • Maher, S.A.1    McCormack, B.A.O.2
  • 24
    • 0020462606 scopus 로고
    • Changes in the bone-cement interface after total hip replacement. An in vivo animal study
    • Radin EL, Rubin CT, Thrasher EL, et al. Changes in the bone-cement interface after total hip replacement. An in vivo animal study. J Bone Joint Surg Am 1982;64:1188-200. (Pubitemid 13244012)
    • (1982) Journal of Bone and Joint Surgery - Series A , vol.64 , Issue.8 , pp. 1188-1200
    • Radin, E.L.1    Rubin, C.T.2    Thrasher, E.L.3
  • 25
    • 0029081031 scopus 로고
    • Prediction of thoracic and lumber vertebral body compressive strength: Correlations with bone mineral density and vertebral region
    • Singer K, Edmondston S, Day R, et al. Prediction of thoracic and lumber vertebral body compressive strength: correlations with bone mineral density and vertebral region. Bone 1995;17:167-74.
    • (1995) Bone , vol.17 , pp. 167-174
    • Singer, K.1    Edmondston, S.2    Day, R.3
  • 26
    • 0032054920 scopus 로고    scopus 로고
    • Biomechanical characterization of a biodegradable calcium phosphate hydraulic cement: A comparison with porous biphasic calcium phosphate ceramics
    • DOI 10.1002/(SICI)1097-4636(199804)40:1<139::AID-JBM16>3.0.CO;2-J
    • Ikenaga M, Hardouin P, Lemaitre J, et al. Biomechanical characterization of a biodegradable calcium phosphate hydraulic cement: a comparison with porous biphasic calcium phosphate ceramics. J Biomed Mater Res 1998;40:139-44. (Pubitemid 28110160)
    • (1998) Journal of Biomedical Materials Research , vol.40 , Issue.1 , pp. 139-144
    • Ikenaga, M.1    Hardouin, P.2    Lemaitre, J.3    Andrianjatovo, H.4    Flautre, B.5
  • 28
    • 34247226787 scopus 로고    scopus 로고
    • Vertebroplasty for osteoporotic fractures with spinal canal compromise
    • Hiwatashi A, Westesson P. Vertebroplasty for osteoporotic fractures with spinal canal compromise. AJNR Am J Neuroradiol 2007;28:690-2. (Pubitemid 46608608)
    • (2007) American Journal of Neuroradiology , vol.28 , Issue.4 , pp. 690-692
    • Hiwatashi, A.1    Westesson, P.-L.A.2
  • 29
    • 22244458950 scopus 로고    scopus 로고
    • Does vertebral body height restoration achieved at vertebroplasty matter?
    • McKiernan F, Faciszewski T, Jensen R. Does vertebral body height restoration achieved at vertebroplasty matter? J Vasc Interv Radiol 2005;16:973-9.
    • (2005) J Vasc Interv Radiol , vol.16 , pp. 973-979
    • McKiernan, F.1    Faciszewski, T.2    Jensen, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.