-
1
-
-
38549105507
-
Alternative acrylic bone cement formulations for cemented arthroplasties: Present status, key issues, and fracture prospects
-
Lewis G. Alternative acrylic bone cement formulations for cemented arthroplasties: Present status, key issues, and fracture prospects. J Biomed Mater Res B: Appl Biomater 2008;84B:301-319.
-
(2008)
J Biomed Mater Res B: Appl Biomater
, vol.84 B
, pp. 301-319
-
-
Lewis, G.1
-
2
-
-
31644450910
-
Injectable bone cements for use in vertebroplasty and kyphoplasty: State-of-art-review
-
Lewis G. Injectable bone cements for use in vertebroplasty and kyphoplasty: State-of-art-review. J Biomed Mater Res B: Appl Biomater 2006;76B:456-468.
-
(2006)
J Biomed Mater Res B: Appl Biomater
, vol.76 B
, pp. 456-468
-
-
Lewis, G.1
-
4
-
-
0037962386
-
Vertebroplasty: Learning more, but not enough
-
Jarvik JG, Kallmes DF, Mirza SK. Vertebroplasty: Learning more, but not enough. Spine 2003;28:1487-1489.
-
(2003)
Spine
, vol.28
, pp. 1487-1489
-
-
Jarvik, J.G.1
Kallmes, D.F.2
Mirza, S.K.3
-
5
-
-
0038638437
-
Temperature measurement during polymerization of polymethylmethacrylate cement used for vertebroplasty
-
Belkoff SM, Molloy S. Temperature measurement during polymerization of polymethylmethacrylate cement used for vertebroplasty. Spine 2003;28:1555-1559.
-
(2003)
Spine
, vol.28
, pp. 1555-1559
-
-
Belkoff, S.M.1
Molloy, S.2
-
6
-
-
0035879117
-
The biomechanics of vertebroplasty. The effect of cement volume on mechanical behavior
-
Belkoff SM, Mathis JM, Jasper LE, Deramond H. The biomechanics of vertebroplasty. The effect of cement volume on mechanical behavior. Spine 2001;26:1537-1541.
-
(2001)
Spine
, vol.26
, pp. 1537-1541
-
-
Belkoff, S.M.1
Mathis, J.M.2
Jasper, L.E.3
Deramond, H.4
-
7
-
-
30444441617
-
Effect of cement volume and placement on mechanical property restoration resulting from vertebroplasty
-
Molloy S, Riley LH, Belkoff SM. Effect of cement volume and placement on mechanical property restoration resulting from vertebroplasty. AJNR Am J Neuroradiol 2005;26:401-404.
-
(2005)
AJNR Am J Neuroradiol
, vol.26
, pp. 401-404
-
-
Molloy, S.1
Riley, L.H.2
Belkoff, S.M.3
-
8
-
-
0043069471
-
Minimally invasive treatments of osteoporotic vertebral compression fractures
-
Phillips FM. Minimally invasive treatments of osteoporotic vertebral compression fractures. Spine 2003;28:S45-S53.
-
(2003)
Spine
, vol.28
-
-
Phillips, F.M.1
-
9
-
-
0035424270
-
The effect of cross-linking agents on acrylic bone cements containing radiopacifiers
-
Deb B, Vazquez B. The effect of cross-linking agents on acrylic bone cements containing radiopacifiers. Biomaterials 2001;22:2177-2181.
-
(2001)
Biomaterials
, vol.22
, pp. 2177-2181
-
-
Deb, B.1
Vazquez, B.2
-
11
-
-
16444384258
-
Influence of the radiopacifier in an acrylic bone cement on its mechanical, thermal, and physical properties: Barium sulfate-containing cement versus iodine-containing cement
-
Lewis G, Van Hooy-Corstjens CSJ, Bhattaram A, Koole LH. Influence of the radiopacifier in an acrylic bone cement on its mechanical, thermal, and physical properties: Barium sulfate-containing cement versus iodine-containing cement. J Biomed Mater Res B: Appl Biomater 2005;73B:77-87.
-
(2005)
J Biomed Mater Res B: Appl Biomater
, vol.73 B
, pp. 77-87
-
-
Lewis, G.1
Van Hooy-Corstjens, C.S.J.2
Bhattaram, A.3
Koole, L.H.4
-
12
-
-
0742289952
-
Mechanical behavior of a new acrylic radiopaque iodine-containing bone cement
-
Van Hooy-Corstjens CSJ, Govaert LE, Spoelstra AB, Bulstra SK, Wetzels GMR, Koole LH. Mechanical behavior of a new acrylic radiopaque iodine-containing bone cement. Biomaterials 2004;25:2657-2667.
-
(2004)
Biomaterials
, vol.25
, pp. 2657-2667
-
-
Van Hooy-Corstjens, C.S.J.1
Govaert, L.E.2
Spoelstra, A.B.3
Bulstra, S.K.4
Wetzels, G.M.R.5
Koole, L.H.6
-
13
-
-
11144267732
-
Static and fatigue mechanical behavior of bone cement with elevated barium sulfate content for treatment of vertebral compression fractures
-
Kurtz SM, Villarraga ML, Zhao K, Edidin AA. Static and fatigue mechanical behavior of bone cement with elevated barium sulfate content for treatment of vertebral compression fractures. Biomaterials 2005;26:3699-3712.
-
(2005)
Biomaterials
, vol.26
, pp. 3699-3712
-
-
Kurtz, S.M.1
Villarraga, M.L.2
Zhao, K.3
Edidin, A.A.4
-
14
-
-
0037089654
-
Mechanical performance of acrylic bone cements containing different radiopacifying agents
-
Ginebra MP, Albuixech L, Fernandez-Barragan E, Aparicio C, Gil FJ, San Roman J, Vazquez B, Planell JA. Mechanical performance of acrylic bone cements containing different radiopacifying agents. Biomaterials 2002;23:1873-1882.
-
(2002)
Biomaterials
, vol.23
, pp. 1873-1882
-
-
Ginebra, M.P.1
Albuixech, L.2
Fernandez-Barragan, E.3
Aparicio, C.4
Gil, F.J.5
San Roman, J.6
Vazquez, B.7
Planell, J.A.8
-
15
-
-
0024753903
-
Fracture toughness of acrylic bone cements
-
Wang CT, Pilliar RM. Fracture toughness of acrylic bone cements. J Mater Sci 1989;24:3725-3738.
-
(1989)
J Mater Sci
, vol.24
, pp. 3725-3738
-
-
Wang, C.T.1
Pilliar, R.M.2
-
16
-
-
0031189303
-
Mechanical and fracture behavior evaluation of commercial acrylic bone cements
-
Vallo CI, Cuadrado TR, Frontine PM. Mechanical and fracture behavior evaluation of commercial acrylic bone cements. Polym Int 1997;43:260-268.
-
(1997)
Polym Int
, vol.43
, pp. 260-268
-
-
Vallo, C.I.1
Cuadrado, T.R.2
Frontine, P.M.3
-
17
-
-
33846332419
-
Radiopacity of tantalum-loaded acrylic bone cement
-
Persson C, Guandalini L, Baruffaldi F, Pierotti L, Baleani M. Radiopacity of tantalum-loaded acrylic bone cement. Proc I Mech E 2006;220:787-791.
-
(2006)
Proc I Mech E
, vol.220
, pp. 787-791
-
-
Persson, C.1
Guandalini, L.2
Baruffaldi, F.3
Pierotti, L.4
Baleani, M.5
-
18
-
-
0032764224
-
A novel high-viscosity, two-solution acrylic bone cement: Effect of chemical composition on properties
-
Hasenwinkel JM, Lautenschlager EP, Wixson RL, Gilbert JL. A novel high-viscosity, two-solution acrylic bone cement: Effect of chemical composition on properties. J. Biomed Mater Res 1999;47:36-45.
-
(1999)
J. Biomed Mater Res
, vol.47
, pp. 36-45
-
-
Hasenwinkel, J.M.1
Lautenschlager, E.P.2
Wixson, R.L.3
Gilbert, J.L.4
-
19
-
-
0037022694
-
Effect of initiation chemistry on the fracture toughness, fatigue strength, and residual monomer content of a novel high-viscosity, two-solution acrylic bone cement
-
Hasenwinkel JM, Lautenschlager EP, Wixson RL, Gilbert JL. Effect of initiation chemistry on the fracture toughness, fatigue strength, and residual monomer content of a novel high-viscosity, two-solution acrylic bone cement. J Biomed Mater Res 2002;59:411-421.
-
(2002)
J Biomed Mater Res
, vol.59
, pp. 411-421
-
-
Hasenwinkel, J.M.1
Lautenschlager, E.P.2
Wixson, R.L.3
Gilbert, J.L.4
-
20
-
-
74749089220
-
Two-solution bone cement with cross-linked beads
-
Chicago, IL, USA
-
Merkhan IK, Gilbert JL, Hasenwinkel JM. Two-solution bone cement with cross-linked beads. Proceedings of the Annual Meeting of the Society for Biomaterials, Chicago, IL, USA 2007.
-
(2007)
Proceedings of the Annual Meeting of the Society for Biomaterials
-
-
Merkhan, I.K.1
Gilbert, J.L.2
Hasenwinkel, J.M.3
-
21
-
-
74749108229
-
-
ASTM F451-99a, 2007e1, Standard Specification for Acrylic Bone Cement. ASTM International, West Conshohocken, PA.
-
ASTM F451-99a, 2007e1, Standard Specification for Acrylic Bone Cement. ASTM International, West Conshohocken, PA.
-
-
-
-
22
-
-
3442896181
-
Bone cement X-ray contrast media: A clinically relevant method of measuring their efficiency
-
Kjellson F, Almen T, Tanner KE, McCarthy ID, Lidgren L. Bone cement X-ray contrast media: A clinically relevant method of measuring their efficiency. J Biomed Mater Res B: Appl Biomater 2004;70B:354-361.
-
(2004)
J Biomed Mater Res B: Appl Biomater
, vol.70 B
, pp. 354-361
-
-
Kjellson, F.1
Almen, T.2
Tanner, K.E.3
McCarthy, I.D.4
Lidgren, L.5
-
23
-
-
17144435759
-
New aspects of the effect of size and size distribution on the setting parameters and mechanical properties of acrylic bone cements
-
Pascual B, Vazquez B, Gurruchaga M, Goni I, Ginebra MP, Gil FJ, Planell JA, Levenfeld B, Roman JS. New aspects of the effect of size and size distribution on the setting parameters and mechanical properties of acrylic bone cements. Biomaterials 1996;17:509-516.
-
(1996)
Biomaterials
, vol.17
, pp. 509-516
-
-
Pascual, B.1
Vazquez, B.2
Gurruchaga, M.3
Goni, I.4
Ginebra, M.P.5
Gil, F.J.6
Planell, J.A.7
Levenfeld, B.8
Roman, J.S.9
-
24
-
-
84989063371
-
Model filled polymers. VII: Flow behavior of polymers containing monodisperse crosslinked polymeric beads
-
Sun L, Park M, Salovey R. Model filled polymers. VII: Flow behavior of polymers containing monodisperse crosslinked polymeric beads. Polym Eng Sci 1992;32:777-785.
-
(1992)
Polym Eng Sci
, vol.32
, pp. 777-785
-
-
Sun, L.1
Park, M.2
Salovey, R.3
-
25
-
-
2342630652
-
Model filled polymers: The effect of particle size on the rheology of filled poly(methyl methacrylate) composites
-
Li JQ, Salovey R. Model filled polymers: The effect of particle size on the rheology of filled poly(methyl methacrylate) composites. Polym Eng Sci 2004;44:452-462.
-
(2004)
Polym Eng Sci
, vol.44
, pp. 452-462
-
-
Li, J.Q.1
Salovey, R.2
|