-
1
-
-
0043165850
-
Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty
-
P. Galibert H. Deramond P. Rosat, et al. [Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty] Neurochirurgie 33 1987 166-168
-
(1987)
Neurochirurgie
, vol.33
, pp. 166-168
-
-
Galibert, P.1
Deramond, H.2
Rosat, P.3
-
2
-
-
0029839843
-
Vertebroplasty and percutaneous interventional radiology in bone metastases: Techniques, indications, contra-indications
-
H. Deramond C. Depriester P. Toussaint [Vertebroplasty and percutaneous interventional radiology in bone metastases: Techniques, indications, contra-indications] Bull Cancer Radiother 83 1996 277-282
-
(1996)
Bull Cancer Radiother.
, vol.83
, pp. 277-282
-
-
Deramond, H.1
Depriester, C.2
Toussaint, P.3
-
3
-
-
0027979920
-
Percutaneous vertebroplasty guided by a combination of CT and fluoroscopy
-
A. Gangi B.A. Kastler J.L. Dietemann Percutaneous vertebroplasty guided by a combination of CT and fluoroscopy AJNR Am J Neuroradiol 15 1994 83-86
-
(1994)
AJNR Am. J. Neuroradiol.
, vol.15
, pp. 83-86
-
-
Gangi, A.1
Kastler, B.A.2
Dietemann, J.L.3
-
4
-
-
0029960122
-
Spinal metastases: Indications for and results of percutaneous injection of acrylic surgical cement
-
A. Weill J. Chiras J.M. Simon, et al. Spinal metastases: Indications for and results of percutaneous injection of acrylic surgical cement Radiology 199 1996 241-247
-
(1996)
Radiology
, vol.199
, pp. 241-247
-
-
Weill, A.1
Chiras, J.2
Simon, J.M.3
-
5
-
-
0035110042
-
Percutaneous vertebroplasty: A developing standard of care for vertebral compression fractures
-
J.M. Mathis J.D. Barr S.M. Belkoff, et al. Percutaneous vertebroplasty: a developing standard of care for vertebral compression fractures AJNR Am J Neuroradiol 22 2001 373-381
-
(2001)
AJNR Am. J. Neuroradiol.
, vol.22
, pp. 373-381
-
-
Mathis, J.M.1
Barr, J.D.2
Belkoff, S.M.3
-
6
-
-
0031961970
-
Percutaneous vertebroplasty treatment of steroid-induced osteoporotic compression fractures
-
J.M. Mathis M. Petri N. Naff Percutaneous vertebroplasty treatment of steroid-induced osteoporotic compression fractures Arthritis Rheum 41 1998 171-175
-
(1998)
Arthritis Rheum.
, vol.41
, pp. 171-175
-
-
Mathis, J.M.1
Petri, M.2
Naff, N.3
-
7
-
-
0037294219
-
Vertebral compression fractures: Pain reduction and improvement in functional mobility after percutaneous polymethylmethacrylate vertebroplasty. Retrospective report of 245 cases
-
A.J. Evans M.E. Jensen K.E. Kip, et al. Vertebral compression fractures: pain reduction and improvement in functional mobility after percutaneous polymethylmethacrylate vertebroplasty. Retrospective report of 245 cases Radiology 226 2003 366-372
-
(2003)
Radiology
, vol.226
, pp. 366-372
-
-
Evans, A.J.1
Jensen, M.E.2
Kip, K.E.3
-
8
-
-
0034655411
-
Percutaneous vertebroplasty for pain relief and spinal stabilization
-
J.D. Barr M.S. Barr T.J. Lemley, et al. Percutaneous vertebroplasty for pain relief and spinal stabilization Spine 25 2000 923-928
-
(2000)
Spine
, vol.25
, pp. 923-928
-
-
Barr, J.D.1
Barr, M.S.2
Lemley, T.J.3
-
9
-
-
0029971187
-
Percutaneous vertebroplasty for osteolytic metastases and myeloma: Effects of the percentage of lesion filling and the leakage of methyl methacrylate at clinical follow-up
-
A. Cotten F. Dewatre B. Cortet, et al. Percutaneous vertebroplasty for osteolytic metastases and myeloma: Effects of the percentage of lesion filling and the leakage of methyl methacrylate at clinical follow-up Radiology 200 1996 525-530
-
(1996)
Radiology
, vol.200
, pp. 525-530
-
-
Cotten, A.1
Dewatre, F.2
Cortet, B.3
-
10
-
-
0037221651
-
Balloon kyphoplasty: One-year outcomes in vertebral body height restoration, chronic pain, and activity levels
-
J.T. Ledlie M. Renfro Balloon kyphoplasty: One-year outcomes in vertebral body height restoration, chronic pain, and activity levels J Neurosurg 98 2003 36-42
-
(2003)
J Neurosurg.
, vol.98
, pp. 36-42
-
-
Ledlie, J.T.1
Renfro, M.2
-
11
-
-
0035879322
-
Initial outcome and efficacy of "kyphoplasty" in the treatment of painful osteoporotic vertebral compression fractures
-
I.H. Lieberman S. Dudeney M.K. Reinhardt, et al. Initial outcome and efficacy of "kyphoplasty" in the treatment of painful osteoporotic vertebral compression fractures Spine 26 2001 1631-1638
-
(2001)
Spine
, vol.26
, pp. 1631-1638
-
-
Lieberman, I.H.1
Dudeney, S.2
Reinhardt, M.K.3
-
12
-
-
0037868322
-
Kyphoplasty for vertebral compression fractures: 1-year clinical outcomes from a prospective study
-
J.V. Coumans M.K. Reinhardt I.H. Lieberman Kyphoplasty for vertebral compression fractures: 1-year clinical outcomes from a prospective study J Neurosurg 99 2003 44-50
-
(2003)
J Neurosurg.
, vol.99
, pp. 44-50
-
-
Coumans, J.V.1
Reinhardt, M.K.2
Lieberman, I.H.3
-
13
-
-
0141780978
-
Early radiographic and clinical results of balloon kyphoplasty for the treatment of osteoporotic vertebral compression fractures
-
F.M. Phillips E. Ho M. Campbell-Hupp, et al. Early radiographic and clinical results of balloon kyphoplasty for the treatment of osteoporotic vertebral compression fractures Spine 28 2003 2260-2265
-
(2003)
Spine
, vol.28
, pp. 2260-2265
-
-
Phillips, F.M.1
Ho, E.2
Campbell-Hupp, M.3
-
14
-
-
12144282299
-
Biomechanical changes following the augmentation of experimental osteoporotic vertebral compression fracture in the cadaveric thoracic spine
-
M.M. Kayanja D. Togawa I.H. Lieberman Biomechanical changes following the augmentation of experimental osteoporotic vertebral compression fracture in the cadaveric thoracic spine Spine J 5 2005 55-63
-
(2005)
Spine J.
, vol.5
, pp. 55-63
-
-
Kayanja, M.M.1
Togawa, D.2
Lieberman, I.H.3
-
15
-
-
0000206228
-
The bonding of prostheses to bone by cement
-
J. Charnley The bonding of prostheses to bone by cement J Bone Joint Surg Br 46 1964 518-529
-
(1964)
J Bone Joint. Surg. Br.
, vol.46
, pp. 518-529
-
-
Charnley, J.1
-
16
-
-
0003762339
-
Bone cements: Up-to-date comparison of physical and chemical properties of commercial materials
-
Berlin: Springer
-
K.D. Kuhn Bone cements: Up-to-date comparison of physical and chemical properties of commercial materials 2000 Springer Berlin p. 21-34
-
(2000)
, pp. 21-34
-
-
Kuhn, K.D.1
-
17
-
-
0347384111
-
Fatigue testing and performance of acrylic bone-cement materials: State-of-the-art review
-
G. Lewis Fatigue testing and performance of acrylic bone-cement materials: State-of-the-art review J Biomed Mater Res 66B 2003 457-486
-
(2003)
J Biomed. Mater. Res.
, vol.66 B
, pp. 457-486
-
-
Lewis, G.1
-
19
-
-
28244449219
-
FDA Public Health Web Notification: Complications related to the use of bone cement and bone void fillers in treating compression fractures of the spine
-
Available at:, Accessed 5/7/
-
FDA Public Health Web Notification: Complications related to the use of bone cement and bone void fillers in treating compression fractures of the spine. Available at: http://www.fda.gov/cdrh/safety/bonecement.pdf. Accessed 5/7/2004.
-
(2004)
-
-
-
20
-
-
0031545893
-
Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: Technical aspects
-
M.E. Jensen A.J. Evans J.M. Mathis, et al. Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: Technical aspects AJNR Am J Neuroradiol 18 1997 1897-1904
-
(1997)
AJNR Am. J. Neuroradiol.
, vol.18
, pp. 1897-1904
-
-
Jensen, M.E.1
Evans, A.J.2
Mathis, J.M.3
-
21
-
-
0032846650
-
Percutaneous vertebroplasty in the treatment of osteoporotic vertebral compression fractures: An open prospective study
-
B. Cortet A. Cotten N. Boutry, et al. Percutaneous vertebroplasty in the treatment of osteoporotic vertebral compression fractures: An open prospective study J Rheumatol 26 1999 2222-2228
-
(1999)
J Rheumatol.
, vol.26
, pp. 2222-2228
-
-
Cortet, B.1
Cotten, A.2
Boutry, N.3
-
22
-
-
0035879089
-
New technologies in spine: Kyphoplasty and vertebroplasty for the treatment of painful osteoporotic compression fractures
-
S.R. Garfin H.A. Yuan M.A. Reiley New technologies in spine: Kyphoplasty and vertebroplasty for the treatment of painful osteoporotic compression fractures Spine 26 2001 1511-1515
-
(2001)
Spine
, vol.26
, pp. 1511-1515
-
-
Garfin, S.R.1
Yuan, H.A.2
Reiley, M.A.3
-
23
-
-
0036570231
-
Kyphoplasty in the treatment of osteolytic vertebral compression fractures as a result of multiple myeloma
-
S. Dudeney I.H. Lieberman M.K. Reinhardt, et al. Kyphoplasty in the treatment of osteolytic vertebral compression fractures as a result of multiple myeloma J Clin Oncol 20 2002 2382-2387
-
(2002)
J Clin. Oncol.
, vol.20
, pp. 2382-2387
-
-
Dudeney, S.1
Lieberman, I.H.2
Reinhardt, M.K.3
-
24
-
-
28244485958
-
Radiographic and histologic findings of vertebral augmentation using polymethylmethacrylate in the primate spine-percutaneous vertebroplasty and kyphoplasty
-
Spine in press
-
Togawa D, Kovacic JJ, Lieberman IH, et al. Radiographic and histologic findings of vertebral augmentation using polymethylmethacrylate in the primate spine-percutaneous vertebroplasty and kyphoplasty. Spine 2005; in press.
-
(2005)
-
-
Togawa, D.1
Kovacic, J.J.2
Lieberman, I.H.3
-
25
-
-
0038376699
-
Histologic evaluation of human vertebral bodies after vertebral augmentation with polymethyl methacrylate
-
D. Togawa T.W. Bauer I.H. Lieberman, et al. Histologic evaluation of human vertebral bodies after vertebral augmentation with polymethyl methacrylate Spine 28 2003 1521-1527
-
(2003)
Spine
, vol.28
, pp. 1521-1527
-
-
Togawa, D.1
Bauer, T.W.2
Lieberman, I.H.3
-
26
-
-
0037214080
-
Asymptomatic diffuse pulmonary embolism caused by acrylic cement: An unusual complication of percutaneous vertebroplasty
-
J. Bernhard P.F. Heini P.M. Villiger Asymptomatic diffuse pulmonary embolism caused by acrylic cement: An unusual complication of percutaneous vertebroplasty Ann Rheum Dis 62 2003 85-86
-
(2003)
Ann. Rheum. Dis.
, vol.62
, pp. 85-86
-
-
Bernhard, J.1
Heini, P.F.2
Villiger, P.M.3
-
27
-
-
0036785755
-
A lethal pulmonary embolism during percutaneous vertebroplasty
-
H.L. Chen C.S. Wong S.T. Ho, et al. A lethal pulmonary embolism during percutaneous vertebroplasty Anesth Analg 95 2002 1060-1062
-
(2002)
Anesth. Analg.
, vol.95
, pp. 1060-1062
-
-
Chen, H.L.1
Wong, C.S.2
Ho, S.T.3
-
28
-
-
0033366518
-
Pulmonary embolism caused by acrylic cement: A rare complication of percutaneous vertebroplasty
-
B. Padovani O. Kasriel P. Brunner, et al. Pulmonary embolism caused by acrylic cement: A rare complication of percutaneous vertebroplasty AJNR Am J Neuroradiol 20 1999 375-377
-
(1999)
AJNR Am. J. Neuroradiol.
, vol.20
, pp. 375-377
-
-
Padovani, B.1
Kasriel, O.2
Brunner, P.3
-
29
-
-
0036098563
-
Paradoxical cerebral arterial embolization of cement during intraoperative vertebroplasty: Case report
-
R. Scroop J. Eskridge G.W. Britz Paradoxical cerebral arterial embolization of cement during intraoperative vertebroplasty: Case report AJNR Am J Neuroradiol 23 2002 868-870
-
(2002)
AJNR Am. J. Neuroradiol.
, vol.23
, pp. 868-870
-
-
Scroop, R.1
Eskridge, J.2
Britz, G.W.3
-
30
-
-
0036841431
-
Management of pulmonary embolism during acrylic vertebroplasty
-
P. Tozzi Y. Abdelmoumene A.F. Corno, et al. Management of pulmonary embolism during acrylic vertebroplasty Ann Thorac Surg 74 2002 1706-1708
-
(2002)
Ann. Thorac. Surg.
, vol.74
, pp. 1706-1708
-
-
Tozzi, P.1
Abdelmoumene, Y.2
Corno, A.F.3
-
32
-
-
0036132596
-
Measurements of the solubilities and dissolution rates of several hydroxyapatites
-
M.T. Fulmer I.C. Ison C.R. Hankermayer, et al. Measurements of the solubilities and dissolution rates of several hydroxyapatites Biomaterials 23 2002 751-755
-
(2002)
Biomaterials
, vol.23
, pp. 751-755
-
-
Fulmer, M.T.1
Ison, I.C.2
Hankermayer, C.R.3
-
33
-
-
0032217161
-
BoneSource hydroxyapatite cement: A novel biomaterial for craniofacial skeletal tissue engineering and reconstruction
-
C.D. Friedman P.D. Costantino S. Takagi, et al. BoneSource hydroxyapatite cement: A novel biomaterial for craniofacial skeletal tissue engineering and reconstruction J Biomed Mater Res 43 1998 428-432
-
(1998)
J Biomed. Mater. Res.
, vol.43
, pp. 428-432
-
-
Friedman, C.D.1
Costantino, P.D.2
Takagi, S.3
-
34
-
-
0033814144
-
Diametral tensile strength and compressive strength of a calcium phosphate cement: Effect of applied pressure
-
L.C. Chow S. Hirayama S. Takagi, et al. Diametral tensile strength and compressive strength of a calcium phosphate cement: Effect of applied pressure J Biomed Mater Res 53 2000 511-517
-
(2000)
J Biomed. Mater. Res.
, vol.53
, pp. 511-517
-
-
Chow, L.C.1
Hirayama, S.2
Takagi, S.3
-
35
-
-
0032736531
-
Alpha-BSM: A biomimetic bone substitute and drug delivery vehicle
-
D.D. Lee A. Tofighi M. Aiolova, et al. alpha-BSM: A biomimetic bone substitute and drug delivery vehicle Clin Orthop 1999 S396-S405
-
(1999)
Clin. Orthop.
-
-
Lee, D.D.1
Tofighi, A.2
Aiolova, M.3
-
36
-
-
4544353771
-
Recombinant human bone morphogenetic protein-2 delivered in an injectable calcium phosphate paste accelerates osteotomy-site healing in a nonhuman primate model
-
H.J. Seeherman M. Bouxsein H. Kim, et al. Recombinant human bone morphogenetic protein-2 delivered in an injectable calcium phosphate paste accelerates osteotomy-site healing in a nonhuman primate model J Bone Joint Surg Am 86-A 2004 1961-1972
-
(2004)
J Bone Joint Surg. Am.
, vol.86 A
, pp. 1961-1972
-
-
Seeherman, H.J.1
Bouxsein, M.2
Kim, H.3
-
37
-
-
0029256548
-
Skeletal repair by in situ formation of the mineral phase of bone
-
B.R. Constantz I.C. Ison M.T. Fulmer, et al. Skeletal repair by in situ formation of the mineral phase of bone Science 267 1995 1796-1799
-
(1995)
Science
, vol.267
, pp. 1796-1799
-
-
Constantz, B.R.1
Ison, I.C.2
Fulmer, M.T.3
-
38
-
-
0036169004
-
Use of injectable calcium phosphate cement for fracture fixation: A review
-
S. Larsson T.W. Bauer Use of injectable calcium phosphate cement for fracture fixation: A review Clin Orthop 2002 23-32
-
(2002)
Clin. Orthop.
, pp. 23-32
-
-
Larsson, S.1
Bauer, T.W.2
-
39
-
-
0031712261
-
Biomechanical and histological evaluation of a calcium phosphate cement
-
E.P. Frankenburg S.A. Goldstein T.W. Bauer, et al. Biomechanical and histological evaluation of a calcium phosphate cement J Bone Joint Surg Am 80 1998 1112-1124
-
(1998)
J Bone Joint Surg. Am.
, vol.80
, pp. 1112-1124
-
-
Frankenburg, E.P.1
Goldstein, S.A.2
Bauer, T.W.3
-
40
-
-
0031924185
-
Norian SRS cement augmentation in hip fracture treatment: Laboratory and initial clinical results
-
S.B. Goodman T.W. Bauer D. Carter, et al. Norian SRS cement augmentation in hip fracture treatment: Laboratory and initial clinical results Clin Orthop 348 1998 42-50
-
(1998)
Clin. Orthop.
, vol.348
, pp. 42-50
-
-
Goodman, S.B.1
Bauer, T.W.2
Carter, D.3
-
41
-
-
0032822564
-
Resorbable bone cement for augmentation of internally fixed hip fractures
-
Annales Chirurgiae et Gynaecologiae
-
S. Larsson P. Mattsson T.W. Bauer Resorbable bone cement for augmentation of internally fixed hip fractures Annales Chirurgiae et Gynaecologiae 88 1999 205-213
-
(1999)
, vol.88
, pp. 205-213
-
-
Larsson, S.1
Mattsson, P.2
Bauer, T.W.3
-
42
-
-
0034207847
-
Open reduction and augmentation of internal fixation with an injectable skeletal cement for the treatment of complex calcaneal fractures
-
T.A. Schildhauer T.W. Bauer C. Josten, et al. Open reduction and augmentation of internal fixation with an injectable skeletal cement for the treatment of complex calcaneal fractures J Orthop Trauma 14 2000 309-317
-
(2000)
J Orthop. Trauma
, vol.14
, pp. 309-317
-
-
Schildhauer, T.A.1
Bauer, T.W.2
Josten, C.3
-
43
-
-
0036505001
-
Balloon vertebroplasty with calcium phosphate cement augmentation for direct restoration of traumatic thoracolumbar vertebral fractures
-
J.J. Verlaan W.H. van Helden F.C. Oner, et al. Balloon vertebroplasty with calcium phosphate cement augmentation for direct restoration of traumatic thoracolumbar vertebral fractures Spine 27 2002 543-548
-
(2002)
Spine
, vol.27
, pp. 543-548
-
-
Verlaan, J.J.1
van Helden, W.H.2
Oner, F.C.3
-
44
-
-
28244497583
-
Vertebroplasty using injectable calcium phosphate cement compared to polymethylmethacrylate in a unique canine vertebral body large defect model
-
New Orleans. Paper #267
-
Turner TM, Urban RM, Lim TH, et al. Vertebroplasty using injectable calcium phosphate cement compared to polymethylmethacrylate in a unique canine vertebral body large defect model. Trans 49th Annual Meeting of Orthopaedic Research Society; 2003; New Orleans. Paper #267.
-
(2003)
Trans 49th Annual Meeting of Orthopaedic Research Society
-
-
Turner, T.M.1
Urban, R.M.2
Lim, T.H.3
-
45
-
-
28244484834
-
Comparison of injectable calcium phosphate cement and polymethylmethacrylate for use in vertebroplasty: In-vivo evaluation using an osteopenic sheep model
-
(abstr.) Presented at the 28th Annual Meeting of the Society of Biomaterials. Tampa, FL, April 24-27
-
S. Takikawa T.W. Bauer A.S. Turner, et al. Comparison of injectable calcium phosphate cement and polymethylmethacrylate for use in vertebroplasty: In-vivo evaluation using an osteopenic sheep model Presented at the 28th Annual Meeting of the Society of Biomaterials. Tampa, FL, April 24-27, 2002 231 (abstr.)
-
(2002)
, pp. 231
-
-
Takikawa, S.1
Bauer, T.W.2
Turner, A.S.3
-
46
-
-
0035879306
-
Effects of bone cement volume and distribution on vertebral stiffness after vertebroplasty
-
M.A. Liebschner W.S. Rosenberg T.M. Keaveny Effects of bone cement volume and distribution on vertebral stiffness after vertebroplasty Spine 26 2001 1547-1554
-
(2001)
Spine
, vol.26
, pp. 1547-1554
-
-
Liebschner, M.A.1
Rosenberg, W.S.2
Keaveny, T.M.3
-
47
-
-
0037096636
-
Biomechanical evaluation of an injectable calcium phosphate cement for vertebroplasty
-
T.H. Lim G.T. Brebach S.M. Renner, et al. Biomechanical evaluation of an injectable calcium phosphate cement for vertebroplasty Spine 27 2002 1297-1302
-
(2002)
Spine
, vol.27
, pp. 1297-1302
-
-
Lim, T.H.1
Brebach, G.T.2
Renner, S.M.3
-
48
-
-
0034193632
-
Experimental vertebroplasty using osteoconductive granular material
-
G. Cunin H. Boissonnet H. Petite, et al. Experimental vertebroplasty using osteoconductive granular material Spine 25 2000 1070-1076
-
(2000)
Spine
, vol.25
, pp. 1070-1076
-
-
Cunin, G.1
Boissonnet, H.2
Petite, H.3
-
49
-
-
0034193728
-
Biomechanical evaluation of a new bone cement for use in vertebroplasty
-
S.M. Belkoff J.M. Mathis E.M. Erbe, et al. Biomechanical evaluation of a new bone cement for use in vertebroplasty Spine 25 2000 1061-1064
-
(2000)
Spine
, vol.25
, pp. 1061-1064
-
-
Belkoff, S.M.1
Mathis, J.M.2
Erbe, E.M.3
-
50
-
-
0035054442
-
Augmentation of mechanical properties in osteoporotic vertebral bones: A biomechanical investigation of vertebroplasty efficacy with different bone cements
-
P.F. Heini U. Berlemann M. Kaufmann, et al. Augmentation of mechanical properties in osteoporotic vertebral bones: A biomechanical investigation of vertebroplasty efficacy with different bone cements Eur Spine J 10 2001 164-171
-
(2001)
Eur. Spine. J.
, vol.10
, pp. 164-171
-
-
Heini, P.F.1
Berlemann, U.2
Kaufmann, M.3
-
51
-
-
0034951131
-
An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with kyphoplasty
-
S.M. Belkoff J.M. Mathis H. Deramond, et al. An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with kyphoplasty AJNR Am J Neuroradiol 22 2001 1212-1216
-
(2001)
AJNR Am. J. Neuroradiol.
, vol.22
, pp. 1212-1216
-
-
Belkoff, S.M.1
Mathis, J.M.2
Deramond, H.3
-
52
-
-
0037515472
-
Resorption evaluation of a large bolus of calcium sulfate in a canine medullary defect
-
T.M. Turner R.M. Urban S. Gitelis, et al. Resorption evaluation of a large bolus of calcium sulfate in a canine medullary defect Orthopedics 26 5, Suppl. 2003 577-579
-
(2003)
Orthopedics
, vol.26
, Issue.5 SUPPL.
, pp. 577-579
-
-
Turner, T.M.1
Urban, R.M.2
Gitelis, S.3
-
53
-
-
28244497001
-
Histological evaluation of calcium sulfate HA/TCP composites using a canine metaphyseal defect model
-
Trans 50th Annual Meeting of Orthopaedic Research Society San Francisco. Poster #1040
-
Togawa D, Reid J, Bauer TW, et al. Histological evaluation of calcium sulfate HA/TCP composites using a canine metaphyseal defect model. Trans 50th Annual Meeting of Orthopaedic Research Society; 2004; San Francisco. Poster #1040.
-
(2004)
-
-
Togawa, D.1
Reid, J.2
Bauer, T.W.3
-
54
-
-
0037043468
-
Evaluation of calcium sulfate paste for augmentation of lumbar pedicle screw pullout strength
-
M.T. Rohmiller D. Schwalm R.C. Glattes, et al. Evaluation of calcium sulfate paste for augmentation of lumbar pedicle screw pullout strength Spine J 2 2002 255-260
-
(2002)
Spine J.
, vol.2
, pp. 255-260
-
-
Rohmiller, M.T.1
Schwalm, D.2
Glattes, R.C.3
-
55
-
-
0035851773
-
In vivo evaluation of calcium sulfate as a bone graft substitute for lumbar spinal fusion
-
P.A. Glazer U.M. Spencer R.N. Alkalay, et al. In vivo evaluation of calcium sulfate as a bone graft substitute for lumbar spinal fusion Spine J 1 2001 395-401
-
(2001)
Spine J.
, vol.1
, pp. 395-401
-
-
Glazer, P.A.1
Spencer, U.M.2
Alkalay, R.N.3
-
56
-
-
1942500920
-
In vivo evaluation of resorbable bone graft substitutes in a rabbit tibial defect model
-
D. Stubbs M. Deakin P. Chapman-Sheath, et al. In vivo evaluation of resorbable bone graft substitutes in a rabbit tibial defect model Biomaterials 25 2004 5037-5044
-
(2004)
Biomaterials
, vol.25
, pp. 5037-5044
-
-
Stubbs, D.1
Deakin, M.2
Chapman-Sheath, P.3
-
57
-
-
0037231525
-
Response of a calcium sulfate bone graft substitute in a confined cancellous defect
-
W.R. Walsh P. Morberg Y. Yu, et al. Response of a calcium sulfate bone graft substitute in a confined cancellous defect Clin Orthop 406 2003 228-236
-
(2003)
Clin. Orthop.
, vol.406
, pp. 228-236
-
-
Walsh, W.R.1
Morberg, P.2
Yu, Y.3
-
58
-
-
28244461960
-
In vitro evaluation of orthopedic composite cytotoxicity: Assessing the potential for postsurgical production of hydroxyl radicals
-
M. DiCicco R. Compton S.A. Jansen-Varnum In vitro evaluation of orthopedic composite cytotoxicity: Assessing the potential for postsurgical production of hydroxyl radicals J Biomed Mater Res 70B 2004 1-20
-
(2004)
J Biomed. Mater. Res.
, vol.70 B
, pp. 1-20
-
-
DiCicco, M.1
Compton, R.2
Jansen-Varnum, S.A.3
-
59
-
-
0034773299
-
Comparison of a new bisphenol-a-glycidyl dimethacrylate-based cortical bone void filler with polymethyl methacrylate
-
E.M. Erbe T.D. Clineff G. Gualtieri Comparison of a new bisphenol-a-glycidyl dimethacrylate-based cortical bone void filler with polymethyl methacrylate Eur Spine J 10 Suppl. 2 2001 S147-S152
-
(2001)
Eur. Spine J.
, vol.10
, Issue.SUPPL. 2
-
-
Erbe, E.M.1
Clineff, T.D.2
Gualtieri, G.3
-
60
-
-
0031778659
-
Percutaneous vertebroplasty with polymethylmethacrylate: Technique, indications, and results
-
H. Deramond C. Depriester P. Galibert, et al. Percutaneous vertebroplasty with polymethylmethacrylate: Technique, indications, and results Radiol Clin North Am 36 1998 533-546
-
(1998)
Radiol. Clin. North. Am
, vol.36
, pp. 533-546
-
-
Deramond, H.1
Depriester, C.2
Galibert, P.3
-
61
-
-
0017015112
-
Mechanical properties of bone cements containing large doses of antibiotic powders
-
E.P. Lautenschlager J.J. Jacobs G.W. Marshall, et la. Mechanical properties of bone cements containing large doses of antibiotic powders J Biomed Mater Res 10 1976 929-938
-
(1976)
J Biomed. Mater. Res.
, vol.10
, pp. 929-938
-
-
Lautenschlager, E.P.1
Jacobs, J.J.2
Marshall, G.W.3
-
62
-
-
0017015636
-
Mechanical strength of acrylic bone cements impregnated with antibiotics
-
E.P. Lautenschlager G.W. Marshall K.E. Marks, et al. Mechanical strength of acrylic bone cements impregnated with antibiotics J Biomed Mater Res 10 1976 837-845
-
(1976)
J Biomed. Mater. Res.
, vol.10
, pp. 837-845
-
-
Lautenschlager, E.P.1
Marshall, G.W.2
Marks, K.E.3
-
63
-
-
0034773733
-
Percutaneous transpedicular polymethylmethacrylate vertebroplasty for the treatment of spinal compression fractures
-
A.P. Amar D.W. Larsen N. Esnaashari, et al. Percutaneous transpedicular polymethylmethacrylate vertebroplasty for the treatment of spinal compression fractures Neurosurgery 49 2001 1105-1114
-
(2001)
Neurosurgery
, vol.49
, pp. 1105-1114
-
-
Amar, A.P.1
Larsen, D.W.2
Esnaashari, N.3
-
64
-
-
0019922589
-
The sustained release of antimicrobial drugs from bone cement: An appraisal of laboratory investigations and their significance
-
R. Bayston R.D. Milner The sustained release of antimicrobial drugs from bone cement: An appraisal of laboratory investigations and their significance J Bone Joint Surg Br 64 1982 460-464
-
(1982)
J Bone Joint Surg. Br.
, vol.64
, pp. 460-464
-
-
Bayston, R.1
Milner, R.D.2
-
65
-
-
0026519438
-
Cranioplasty using gentamicin-loaded acrylic cement: A test of neurotoxicity
-
J.F. Ronderos D.A. Wiles F.A. Ragan, et al. Cranioplasty using gentamicin-loaded acrylic cement: A test of neurotoxicity Surg Neurol 37 1992 356-360
-
(1992)
Surg. Neurol.
, vol.37
, pp. 356-360
-
-
Ronderos, J.F.1
Wiles, D.A.2
Ragan, F.A.3
-
66
-
-
0029076208
-
Effect of varying surface patterns on antibiotic elution from antibiotic-loaded bone cement
-
B.A. Masri C.P. Duncan C.P. Beauchamp, et al. Effect of varying surface patterns on antibiotic elution from antibiotic-loaded bone cement J Arthroplasty 10 1995 453-459
-
(1995)
J Arthroplasty
, vol.10
, pp. 453-459
-
-
Masri, B.A.1
Duncan, C.P.2
Beauchamp, C.P.3
-
67
-
-
0034266967
-
In vitro elution of gentamicin, amikacin, and ceftiofur from polymethylmethacrylate and hydroxyapatite cement
-
M.T. Ethell R.A. Bennett M.P. Brown, et al. In vitro elution of gentamicin, amikacin, and ceftiofur from polymethylmethacrylate and hydroxyapatite cement Vet Surg 29 2000 375-382
-
(2000)
Vet. Surg.
, vol.29
, pp. 375-382
-
-
Ethell, M.T.1
Bennett, R.A.2
Brown, M.P.3
-
68
-
-
0036020553
-
Release of gentamicin sulphate from a modified commercial bone cement. Effect of (2-hydroxyethyl methacrylate) comonomer and poly(N-vinyl-2-pyrrolidone) additive on release mechanism and kinetics
-
P. Frutos E. Diez-Pena G. Frutos, et al. Release of gentamicin sulphate from a modified commercial bone cement. Effect of (2-hydroxyethyl methacrylate) comonomer and poly(N-vinyl-2-pyrrolidone) additive on release mechanism and kinetics Biomaterials 23 2002 3787-3797
-
(2002)
Biomaterials
, vol.23
, pp. 3787-3797
-
-
Frutos, P.1
Diez-Pena, E.2
Frutos, G.3
-
69
-
-
0033761357
-
Percutaneous vertebroplasty in benign and malignant disease
-
K.J. Murphy H. Deramond Percutaneous vertebroplasty in benign and malignant disease Neuroimaging Clin North Am 10 2000 535-545
-
(2000)
Neuroimaging Clin. North Am.
, vol.10
, pp. 535-545
-
-
Murphy, K.J.1
Deramond, H.2
-
73
-
-
0018594154
-
The effects of barium sulfate on the polymerization temperature and shear strength of surgical simplex P
-
S.P. Combs A.S. Greenwald The effects of barium sulfate on the polymerization temperature and shear strength of surgical simplex P Clin Orthop 145 1979 287-291
-
(1979)
Clin. Orthop.
, vol.145
, pp. 287-291
-
-
Combs, S.P.1
Greenwald, A.S.2
-
75
-
-
0034985296
-
The effects of particulate bone cements at the bone-implant interface
-
J.A. Wimhurst R.A. Brooks N. Rushton The effects of particulate bone cements at the bone-implant interface J Bone Joint Surg Br 83 2001 588-592
-
(2001)
J Bone Joint Surg. Br.
, vol.83
, pp. 588-592
-
-
Wimhurst, J.A.1
Brooks, R.A.2
Rushton, N.3
-
76
-
-
0032810055
-
The use of an injectable, biodegradable calcium phosphate bone substitute for the prophylactic augmentation of osteoporotic vertebrae and the management of vertebral compression fractures
-
B. Bai L.M. Jazrawi F.J. Kummer, et al. The use of an injectable, biodegradable calcium phosphate bone substitute for the prophylactic augmentation of osteoporotic vertebrae and the management of vertebral compression fractures Spine 24 1999 1521-1526
-
(1999)
Spine
, vol.24
, pp. 1521-1526
-
-
Bai, B.1
Jazrawi, L.M.2
Kummer, F.J.3
-
77
-
-
0032803123
-
An in vitro biomechanical evaluation of bone cements used in percutaneous vertebroplasty
-
S.M. Belkoff M. Maroney D.C. Fenton, et al. An in vitro biomechanical evaluation of bone cements used in percutaneous vertebroplasty Bone 25 1999 23S-26S
-
(1999)
Bone
, vol.25
-
-
Belkoff, S.M.1
Maroney, M.2
Fenton, D.C.3
-
78
-
-
0035879117
-
The biomechanics of vertebroplasty: The effect of cement volume on mechanical behavior
-
S.M. Belkoff J.M. Mathis L.E. Jasper, et al. The biomechanics of vertebroplasty: The effect of cement volume on mechanical behavior Spine 26 2001 1537-1541
-
(2001)
Spine
, vol.26
, pp. 1537-1541
-
-
Belkoff, S.M.1
Mathis, J.M.2
Jasper, L.E.3
-
79
-
-
0035879286
-
An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with vertebroplasty
-
S.M. Belkoff J.M. Mathis L.E. Jasper, et al. An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with vertebroplasty Spine 26 2001 1542-1546
-
(2001)
Spine
, vol.26
, pp. 1542-1546
-
-
Belkoff, S.M.1
Mathis, J.M.2
Jasper, L.E.3
-
80
-
-
0035863342
-
An ex vivo biomechanical evaluation of an inflatable bone tamp used in the treatment of compression fracture
-
S.M. Belkoff J.M. Mathis D.C. Fenton, et al. An ex vivo biomechanical evaluation of an inflatable bone tamp used in the treatment of compression fracture Spine 26 2001 151-156
-
(2001)
Spine
, vol.26
, pp. 151-156
-
-
Belkoff, S.M.1
Mathis, J.M.2
Fenton, D.C.3
-
81
-
-
0037962372
-
Biomechanical effects of unipedicular vertebroplasty on intact vertebrae
-
K.B. Higgins R.D. Harten N.A. Langrana, et al. Biomechanical effects of unipedicular vertebroplasty on intact vertebrae Spine 28 2003 1540-1547
-
(2003)
Spine
, vol.28
, pp. 1540-1547
-
-
Higgins, K.B.1
Harten, R.D.2
Langrana, N.A.3
-
82
-
-
0038638438
-
The effect of vertebral body percentage fill on mechanical behavior during percutaneous vertebroplasty
-
S. Molloy J.M. Mathis S.M. Belkoff The effect of vertebral body percentage fill on mechanical behavior during percutaneous vertebroplasty Spine 28 2003 1549-1554
-
(2003)
Spine
, vol.28
, pp. 1549-1554
-
-
Molloy, S.1
Mathis, J.M.2
Belkoff, S.M.3
-
83
-
-
0033200346
-
Biomechanical efficacy of unipedicular versus bipedicular vertebroplasty for the management of osteoporotic compression fractures
-
A.G. Tohmeh J.M. Mathis D.C. Fenton, et al. Biomechanical efficacy of unipedicular versus bipedicular vertebroplasty for the management of osteoporotic compression fractures Spine 24 1999 1772-1776
-
(1999)
Spine
, vol.24
, pp. 1772-1776
-
-
Tohmeh, A.G.1
Mathis, J.M.2
Fenton, D.C.3
-
84
-
-
0037263256
-
Biomechanical evaluation of kyphoplasty and vertebroplasty with calcium phosphate cement in a simulated osteoporotic compression fracture
-
S. Tomita A. Kin M. Yazu, et al. Biomechanical evaluation of kyphoplasty and vertebroplasty with calcium phosphate cement in a simulated osteoporotic compression fracture J Orthop Sci 8 2003 192-197
-
(2003)
J Orthop. Sci.
, vol.8
, pp. 192-197
-
-
Tomita, S.1
Kin, A.2
Yazu, M.3
-
85
-
-
0036328899
-
Adjacent vertebral failure after vertebroplasty: A biomechanical investigation
-
U. Berlemann S.J. Ferguson L.P. Nolte, et al. Adjacent vertebral failure after vertebroplasty: A biomechanical investigation J Bone Joint Surg Br 84 2002 748-752
-
(2002)
J Bone Joint Surg. Br.
, vol.84
, pp. 748-752
-
-
Berlemann, U.1
Ferguson, S.J.2
Nolte, L.P.3
-
86
-
-
0032802422
-
The effect of monomer-to-powder ratio on the material properties of cranioplastic
-
L.E. Jasper H. Deramond J.M. Mathis, et al. The effect of monomer-to-powder ratio on the material properties of cranioplastic Bone 25 1999 27S-29S
-
(1999)
Bone
, vol.25
-
-
Jasper, L.E.1
Deramond, H.2
Mathis, J.M.3
-
87
-
-
0036774297
-
Percutaneous transpedicular vertebroplasty with calcium phosphate cement in the treatment of osteoporotic vertebral compression and burst fractures
-
M. Nakano N. Hirano K. Matsuura, et al. Percutaneous transpedicular vertebroplasty with calcium phosphate cement in the treatment of osteoporotic vertebral compression and burst fractures J Neurosurg 97 2002 287-293
-
(2002)
J Neurosurg.
, vol.97
, pp. 287-293
-
-
Nakano, M.1
Hirano, N.2
Matsuura, K.3
-
88
-
-
28244495019
-
Repair of osteoporotic vertebral compression fracture by transpedicular injection of bioactive calcium phosphate cement into the vertebral body
-
R. Takemasa H. Yamamoto, et al. Repair of osteoporotic vertebral compression fracture by transpedicular injection of bioactive calcium phosphate cement into the vertebral body Spine J 2 2002 96
-
(2002)
Spine J.
, vol.2
, pp. 96
-
-
Takemasa, R.1
Yamamoto, H.2
-
89
-
-
1642379433
-
Percutaneous vertebroplasty
-
Springer New York
-
H. Deramond J.E. Dion J. Chiras Complications J.M. Mathis H. Deramond S.M. Belkoff Percutaneous vertebroplasty 2002 Springer New York 165-173
-
(2002)
, pp. 165-173
-
-
Deramond, H.1
Dion, J.E.2
Chiras, J.3
-
90
-
-
0015955977
-
2,012 total hip arthroplasties. A study of postoperative course and early complications
-
M.B. Coventry R.D. Beckenbaugh D.R. Nolan, et al. 2,012 total hip arthroplasties. A study of postoperative course and early complications J Bone Joint Surg Am 56 1974 273-284
-
(1974)
J Bone Joint Surg. Am.
, vol.56
, pp. 273-284
-
-
Coventry, M.B.1
Beckenbaugh, R.D.2
Nolan, D.R.3
-
91
-
-
0003979031
-
Systemic effects of monomer
-
E. & S. Livingstone Edinburgh and London
-
J. Charnley Systemic effects of monomer Charnley J, editor. Acrylic cement in orthopaedic surgery 1970 E. & S. Livingstone Edinburgh and London 72-78
-
(1970)
, pp. 72-78
-
-
Charnley, J.1
-
92
-
-
0036790721
-
An in vivo comparison of the potential for extravertebral cement leak after vertebroplasty and kyphoplasty
-
F.M. Phillips F. Todd Wetzel I. Lieberman, et al. An in vivo comparison of the potential for extravertebral cement leak after vertebroplasty and kyphoplasty Spine 27 2002 2173-2178
-
(2002)
Spine
, vol.27
, pp. 2173-2178
-
-
Phillips, F.M.1
Todd Wetzel, F.2
Lieberman, I.3
-
93
-
-
0025604511
-
Cardiopulmonary arrest following an infusion of calcium 2-amino ethanol phosphate
-
D. Sauter L. Goldfrank B.D. Charash Cardiopulmonary arrest following an infusion of calcium 2-amino ethanol phosphate J Emerg Med 8 1990 717-720
-
(1990)
J Emerg. Med.
, vol.8
, pp. 717-720
-
-
Sauter, D.1
Goldfrank, L.2
Charash, B.D.3
-
94
-
-
0032586923
-
Disseminated ischemic necrosis and livedo racemosa in a chronic dialysis patient with calciphylaxis
-
A. Henschel L. Dannenberg U. Gobel, et al. [Disseminated ischemic necrosis and livedo racemosa in a chronic dialysis patient with calciphylaxis] Hautarzt 50 1999 439-444
-
(1999)
Hautarzt
, vol.50
, pp. 439-444
-
-
Henschel, A.1
Dannenberg, L.2
Gobel, U.3
-
95
-
-
0030921599
-
Local tissue irritating effects and adjuvant activities of calcium phosphate and aluminium hydroxide with different physical properties
-
N. Goto H. Kato J. Maeyama Local tissue irritating effects and adjuvant activities of calcium phosphate and aluminium hydroxide with different physical properties Vaccine 15 1997 1364-1371
-
(1997)
Vaccine
, vol.15
, pp. 1364-1371
-
-
Goto, N.1
Kato, H.2
Maeyama, J.3
-
96
-
-
0033804654
-
Particulate adjuvants can induce macrophage survival, DNA synthesis, and a synergistic proliferative response to GM-CSF and CSF-1
-
J.A. Hamilton R. Byrne G. Whitty Particulate adjuvants can induce macrophage survival, DNA synthesis, and a synergistic proliferative response to GM-CSF and CSF-1 J Leukoc Biol 67 2000 226-232
-
(2000)
J Leukoc. Biol.
, vol.67
, pp. 226-232
-
-
Hamilton, J.A.1
Byrne, R.2
Whitty, G.3
-
97
-
-
0032521419
-
Reinforcement of thoracolumbar burst fractures with calcium phosphate cement. A biomechanical study
-
L.E. Mermelstein R.F. McLain S.A. Yerby Reinforcement of thoracolumbar burst fractures with calcium phosphate cement. A biomechanical study Spine 23 1998 664-670
-
(1998)
Spine
, vol.23
, pp. 664-670
-
-
Mermelstein, L.E.1
McLain, R.F.2
Yerby, S.A.3
-
98
-
-
0034650413
-
Effect of augmentation on the mechanics of vertebral wedge fractures
-
D.R. Wilson E.R. Myers J.M. Mathis, et al. Effect of augmentation on the mechanics of vertebral wedge fractures Spine 25 2000 158-165
-
(2000)
Spine
, vol.25
, pp. 158-165
-
-
Wilson, D.R.1
Myers, E.R.2
Mathis, J.M.3
-
99
-
-
0034520393
-
The strengthening effect of percutaneous vertebroplasty
-
J.R. Dean K.T. Ison P. Gishen The strengthening effect of percutaneous vertebroplasty Clin Radiol 55 2000 471-476
-
(2000)
Clin. Radiol.
, vol.55
, pp. 471-476
-
-
Dean, J.R.1
Ison, K.T.2
Gishen, P.3
-
100
-
-
0035118517
-
Mechanical augmentation of the vertebral body by calcium phosphate cement injection
-
M. Ikeuchi H. Yamamoto T. Shibata, et al. Mechanical augmentation of the vertebral body by calcium phosphate cement injection J Orthop Sci 6 2001 39-45
-
(2001)
J Orthop. Sci.
, vol.6
, pp. 39-45
-
-
Ikeuchi, M.1
Yamamoto, H.2
Shibata, T.3
-
101
-
-
0035489425
-
Comparison of the biomechanics of hydroxyapatite and polymethylmethacrylate vertebroplasty in a cadaveric spinal compression fracture model
-
P.W. Hitchon V. Goel J. Drake, et al. Comparison of the biomechanics of hydroxyapatite and polymethylmethacrylate vertebroplasty in a cadaveric spinal compression fracture model J Neurosurg 95 2001 215-220
-
(2001)
J Neurosurg.
, vol.95
, pp. 215-220
-
-
Hitchon, P.W.1
Goel, V.2
Drake, J.3
-
102
-
-
0037648845
-
The effect of cement augmentation on the load transfer in an osteoporotic functional spinal unit: Finite-element analysis
-
A. Polikeit L.P. Nolte S.J. Ferguson The effect of cement augmentation on the load transfer in an osteoporotic functional spinal unit: finite-element analysis Spine 28 2003 991-996
-
(2003)
Spine
, vol.28
, pp. 991-996
-
-
Polikeit, A.1
Nolte, L.P.2
Ferguson, S.J.3
-
103
-
-
0042737757
-
Load shift of the intervertebral disc after a vertebroplasty: A finite-element study
-
G. Baroud J. Nemes P. Heini, et al. Load shift of the intervertebral disc after a vertebroplasty: A finite-element study Eur Spine J 12 2003 421-426
-
(2003)
Eur. Spine J.
, vol.12
, pp. 421-426
-
-
Baroud, G.1
Nemes, J.2
Heini, P.3
-
104
-
-
3042770918
-
Biomechanics of prophylactic vertebral reinforcement
-
K. Sun M.A. Liebschner Biomechanics of prophylactic vertebral reinforcement Spine 29 2004 1428-1435
-
(2004)
Spine
, vol.29
, pp. 1428-1435
-
-
Sun, K.1
Liebschner, M.A.2
-
105
-
-
2542500514
-
Biomechanical comparison of kyphoplasty with different bone cements
-
S. Tomita S. Molloy L.E. Jasper, et al. Biomechanical comparison of kyphoplasty with different bone cements Spine 29 2004 1203-1207
-
(2004)
Spine
, vol.29
, pp. 1203-1207
-
-
Tomita, S.1
Molloy, S.2
Jasper, L.E.3
-
106
-
-
28244450221
-
The biomechanics of polymethylmethacrylate augmentation
-
(in press)
-
Kayanja MM, Evans K, Milks R, et al. The biomechanics of polymethylmethacrylate augmentation. Clin Orthop 2005 (in press).
-
(2005)
Clin. Orthop.
-
-
Kayanja, M.M.1
Evans, K.2
Milks, R.3
|