메뉴 건너뛰기




Volumn 5, Issue 6 SUPPL., 2005, Pages S305-S316

Vertebroplasty and kyphoplasty: Filler materials

Author keywords

Calcium phosphate cement; Calcium sulfate cement; Kyphoplasty; Polymethylmethacrylate; Vertebral compression fracture; Vertebroplasty

Indexed keywords

ACRYLIC CEMENT; AMIKACIN; ANTIBIOTIC AGENT; BARIUM SULFATE; BONE CEMENT; CALCIUM PHOSPHATE; CALCIUM SULFATE; FILLER; GENTAMICIN; HYDROXYAPATITE; POLY(METHYL METHACRYLATE); TANTALUM; TOBRAMYCIN; TUNGSTEN; ZIRCONIUM OXIDE;

EID: 28244447728     PISSN: 15299430     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.spinee.2005.02.020     Document Type: Article
Times cited : (194)

References (106)
  • 1
    • 0043165850 scopus 로고
    • Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty
    • P. Galibert H. Deramond P. Rosat, et al. [Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty] Neurochirurgie 33 1987 166-168
    • (1987) Neurochirurgie , vol.33 , pp. 166-168
    • Galibert, P.1    Deramond, H.2    Rosat, P.3
  • 2
    • 0029839843 scopus 로고    scopus 로고
    • Vertebroplasty and percutaneous interventional radiology in bone metastases: Techniques, indications, contra-indications
    • H. Deramond C. Depriester P. Toussaint [Vertebroplasty and percutaneous interventional radiology in bone metastases: Techniques, indications, contra-indications] Bull Cancer Radiother 83 1996 277-282
    • (1996) Bull Cancer Radiother. , vol.83 , pp. 277-282
    • Deramond, H.1    Depriester, C.2    Toussaint, P.3
  • 3
    • 0027979920 scopus 로고
    • Percutaneous vertebroplasty guided by a combination of CT and fluoroscopy
    • A. Gangi B.A. Kastler J.L. Dietemann Percutaneous vertebroplasty guided by a combination of CT and fluoroscopy AJNR Am J Neuroradiol 15 1994 83-86
    • (1994) AJNR Am. J. Neuroradiol. , vol.15 , pp. 83-86
    • Gangi, A.1    Kastler, B.A.2    Dietemann, J.L.3
  • 4
    • 0029960122 scopus 로고    scopus 로고
    • Spinal metastases: Indications for and results of percutaneous injection of acrylic surgical cement
    • A. Weill J. Chiras J.M. Simon, et al. Spinal metastases: Indications for and results of percutaneous injection of acrylic surgical cement Radiology 199 1996 241-247
    • (1996) Radiology , vol.199 , pp. 241-247
    • Weill, A.1    Chiras, J.2    Simon, J.M.3
  • 5
    • 0035110042 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty: A developing standard of care for vertebral compression fractures
    • J.M. Mathis J.D. Barr S.M. Belkoff, et al. Percutaneous vertebroplasty: a developing standard of care for vertebral compression fractures AJNR Am J Neuroradiol 22 2001 373-381
    • (2001) AJNR Am. J. Neuroradiol. , vol.22 , pp. 373-381
    • Mathis, J.M.1    Barr, J.D.2    Belkoff, S.M.3
  • 6
    • 0031961970 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty treatment of steroid-induced osteoporotic compression fractures
    • J.M. Mathis M. Petri N. Naff Percutaneous vertebroplasty treatment of steroid-induced osteoporotic compression fractures Arthritis Rheum 41 1998 171-175
    • (1998) Arthritis Rheum. , vol.41 , pp. 171-175
    • Mathis, J.M.1    Petri, M.2    Naff, N.3
  • 7
    • 0037294219 scopus 로고    scopus 로고
    • Vertebral compression fractures: Pain reduction and improvement in functional mobility after percutaneous polymethylmethacrylate vertebroplasty. Retrospective report of 245 cases
    • A.J. Evans M.E. Jensen K.E. Kip, et al. Vertebral compression fractures: pain reduction and improvement in functional mobility after percutaneous polymethylmethacrylate vertebroplasty. Retrospective report of 245 cases Radiology 226 2003 366-372
    • (2003) Radiology , vol.226 , pp. 366-372
    • Evans, A.J.1    Jensen, M.E.2    Kip, K.E.3
  • 8
    • 0034655411 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty for pain relief and spinal stabilization
    • J.D. Barr M.S. Barr T.J. Lemley, et al. Percutaneous vertebroplasty for pain relief and spinal stabilization Spine 25 2000 923-928
    • (2000) Spine , vol.25 , pp. 923-928
    • Barr, J.D.1    Barr, M.S.2    Lemley, T.J.3
  • 9
    • 0029971187 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty for osteolytic metastases and myeloma: Effects of the percentage of lesion filling and the leakage of methyl methacrylate at clinical follow-up
    • A. Cotten F. Dewatre B. Cortet, et al. Percutaneous vertebroplasty for osteolytic metastases and myeloma: Effects of the percentage of lesion filling and the leakage of methyl methacrylate at clinical follow-up Radiology 200 1996 525-530
    • (1996) Radiology , vol.200 , pp. 525-530
    • Cotten, A.1    Dewatre, F.2    Cortet, B.3
  • 10
    • 0037221651 scopus 로고    scopus 로고
    • Balloon kyphoplasty: One-year outcomes in vertebral body height restoration, chronic pain, and activity levels
    • J.T. Ledlie M. Renfro Balloon kyphoplasty: One-year outcomes in vertebral body height restoration, chronic pain, and activity levels J Neurosurg 98 2003 36-42
    • (2003) J Neurosurg. , vol.98 , pp. 36-42
    • Ledlie, J.T.1    Renfro, M.2
  • 11
    • 0035879322 scopus 로고    scopus 로고
    • Initial outcome and efficacy of "kyphoplasty" in the treatment of painful osteoporotic vertebral compression fractures
    • I.H. Lieberman S. Dudeney M.K. Reinhardt, et al. Initial outcome and efficacy of "kyphoplasty" in the treatment of painful osteoporotic vertebral compression fractures Spine 26 2001 1631-1638
    • (2001) Spine , vol.26 , pp. 1631-1638
    • Lieberman, I.H.1    Dudeney, S.2    Reinhardt, M.K.3
  • 12
    • 0037868322 scopus 로고    scopus 로고
    • Kyphoplasty for vertebral compression fractures: 1-year clinical outcomes from a prospective study
    • J.V. Coumans M.K. Reinhardt I.H. Lieberman Kyphoplasty for vertebral compression fractures: 1-year clinical outcomes from a prospective study J Neurosurg 99 2003 44-50
    • (2003) J Neurosurg. , vol.99 , pp. 44-50
    • Coumans, J.V.1    Reinhardt, M.K.2    Lieberman, I.H.3
  • 13
    • 0141780978 scopus 로고    scopus 로고
    • Early radiographic and clinical results of balloon kyphoplasty for the treatment of osteoporotic vertebral compression fractures
    • F.M. Phillips E. Ho M. Campbell-Hupp, et al. Early radiographic and clinical results of balloon kyphoplasty for the treatment of osteoporotic vertebral compression fractures Spine 28 2003 2260-2265
    • (2003) Spine , vol.28 , pp. 2260-2265
    • Phillips, F.M.1    Ho, E.2    Campbell-Hupp, M.3
  • 14
    • 12144282299 scopus 로고    scopus 로고
    • Biomechanical changes following the augmentation of experimental osteoporotic vertebral compression fracture in the cadaveric thoracic spine
    • M.M. Kayanja D. Togawa I.H. Lieberman Biomechanical changes following the augmentation of experimental osteoporotic vertebral compression fracture in the cadaveric thoracic spine Spine J 5 2005 55-63
    • (2005) Spine J. , vol.5 , pp. 55-63
    • Kayanja, M.M.1    Togawa, D.2    Lieberman, I.H.3
  • 15
    • 0000206228 scopus 로고
    • The bonding of prostheses to bone by cement
    • J. Charnley The bonding of prostheses to bone by cement J Bone Joint Surg Br 46 1964 518-529
    • (1964) J Bone Joint. Surg. Br. , vol.46 , pp. 518-529
    • Charnley, J.1
  • 16
    • 0003762339 scopus 로고    scopus 로고
    • Bone cements: Up-to-date comparison of physical and chemical properties of commercial materials
    • Berlin: Springer
    • K.D. Kuhn Bone cements: Up-to-date comparison of physical and chemical properties of commercial materials 2000 Springer Berlin p. 21-34
    • (2000) , pp. 21-34
    • Kuhn, K.D.1
  • 17
    • 0347384111 scopus 로고    scopus 로고
    • Fatigue testing and performance of acrylic bone-cement materials: State-of-the-art review
    • G. Lewis Fatigue testing and performance of acrylic bone-cement materials: State-of-the-art review J Biomed Mater Res 66B 2003 457-486
    • (2003) J Biomed. Mater. Res. , vol.66 B , pp. 457-486
    • Lewis, G.1
  • 18
    • 0036172696 scopus 로고    scopus 로고
    • Material properties of various cements for use with vertebroplasty
    • L.E. Jasper H. Deramond J.M. Mathis, et al. Material properties of various cements for use with vertebroplasty J Mater Sci Mater Med 13 2002 1-5
    • (2002) J Mater. Sci. Mater. Med. , vol.13 , pp. 1-5
    • Jasper, L.E.1    Deramond, H.2    Mathis, J.M.3
  • 19
    • 28244449219 scopus 로고    scopus 로고
    • FDA Public Health Web Notification: Complications related to the use of bone cement and bone void fillers in treating compression fractures of the spine
    • Available at:, Accessed 5/7/
    • FDA Public Health Web Notification: Complications related to the use of bone cement and bone void fillers in treating compression fractures of the spine. Available at: http://www.fda.gov/cdrh/safety/bonecement.pdf. Accessed 5/7/2004.
    • (2004)
  • 20
    • 0031545893 scopus 로고    scopus 로고
    • Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: Technical aspects
    • M.E. Jensen A.J. Evans J.M. Mathis, et al. Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: Technical aspects AJNR Am J Neuroradiol 18 1997 1897-1904
    • (1997) AJNR Am. J. Neuroradiol. , vol.18 , pp. 1897-1904
    • Jensen, M.E.1    Evans, A.J.2    Mathis, J.M.3
  • 21
    • 0032846650 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty in the treatment of osteoporotic vertebral compression fractures: An open prospective study
    • B. Cortet A. Cotten N. Boutry, et al. Percutaneous vertebroplasty in the treatment of osteoporotic vertebral compression fractures: An open prospective study J Rheumatol 26 1999 2222-2228
    • (1999) J Rheumatol. , vol.26 , pp. 2222-2228
    • Cortet, B.1    Cotten, A.2    Boutry, N.3
  • 22
    • 0035879089 scopus 로고    scopus 로고
    • New technologies in spine: Kyphoplasty and vertebroplasty for the treatment of painful osteoporotic compression fractures
    • S.R. Garfin H.A. Yuan M.A. Reiley New technologies in spine: Kyphoplasty and vertebroplasty for the treatment of painful osteoporotic compression fractures Spine 26 2001 1511-1515
    • (2001) Spine , vol.26 , pp. 1511-1515
    • Garfin, S.R.1    Yuan, H.A.2    Reiley, M.A.3
  • 23
    • 0036570231 scopus 로고    scopus 로고
    • Kyphoplasty in the treatment of osteolytic vertebral compression fractures as a result of multiple myeloma
    • S. Dudeney I.H. Lieberman M.K. Reinhardt, et al. Kyphoplasty in the treatment of osteolytic vertebral compression fractures as a result of multiple myeloma J Clin Oncol 20 2002 2382-2387
    • (2002) J Clin. Oncol. , vol.20 , pp. 2382-2387
    • Dudeney, S.1    Lieberman, I.H.2    Reinhardt, M.K.3
  • 24
    • 28244485958 scopus 로고    scopus 로고
    • Radiographic and histologic findings of vertebral augmentation using polymethylmethacrylate in the primate spine-percutaneous vertebroplasty and kyphoplasty
    • Spine in press
    • Togawa D, Kovacic JJ, Lieberman IH, et al. Radiographic and histologic findings of vertebral augmentation using polymethylmethacrylate in the primate spine-percutaneous vertebroplasty and kyphoplasty. Spine 2005; in press.
    • (2005)
    • Togawa, D.1    Kovacic, J.J.2    Lieberman, I.H.3
  • 25
    • 0038376699 scopus 로고    scopus 로고
    • Histologic evaluation of human vertebral bodies after vertebral augmentation with polymethyl methacrylate
    • D. Togawa T.W. Bauer I.H. Lieberman, et al. Histologic evaluation of human vertebral bodies after vertebral augmentation with polymethyl methacrylate Spine 28 2003 1521-1527
    • (2003) Spine , vol.28 , pp. 1521-1527
    • Togawa, D.1    Bauer, T.W.2    Lieberman, I.H.3
  • 26
    • 0037214080 scopus 로고    scopus 로고
    • Asymptomatic diffuse pulmonary embolism caused by acrylic cement: An unusual complication of percutaneous vertebroplasty
    • J. Bernhard P.F. Heini P.M. Villiger Asymptomatic diffuse pulmonary embolism caused by acrylic cement: An unusual complication of percutaneous vertebroplasty Ann Rheum Dis 62 2003 85-86
    • (2003) Ann. Rheum. Dis. , vol.62 , pp. 85-86
    • Bernhard, J.1    Heini, P.F.2    Villiger, P.M.3
  • 27
    • 0036785755 scopus 로고    scopus 로고
    • A lethal pulmonary embolism during percutaneous vertebroplasty
    • H.L. Chen C.S. Wong S.T. Ho, et al. A lethal pulmonary embolism during percutaneous vertebroplasty Anesth Analg 95 2002 1060-1062
    • (2002) Anesth. Analg. , vol.95 , pp. 1060-1062
    • Chen, H.L.1    Wong, C.S.2    Ho, S.T.3
  • 28
    • 0033366518 scopus 로고    scopus 로고
    • Pulmonary embolism caused by acrylic cement: A rare complication of percutaneous vertebroplasty
    • B. Padovani O. Kasriel P. Brunner, et al. Pulmonary embolism caused by acrylic cement: A rare complication of percutaneous vertebroplasty AJNR Am J Neuroradiol 20 1999 375-377
    • (1999) AJNR Am. J. Neuroradiol. , vol.20 , pp. 375-377
    • Padovani, B.1    Kasriel, O.2    Brunner, P.3
  • 29
    • 0036098563 scopus 로고    scopus 로고
    • Paradoxical cerebral arterial embolization of cement during intraoperative vertebroplasty: Case report
    • R. Scroop J. Eskridge G.W. Britz Paradoxical cerebral arterial embolization of cement during intraoperative vertebroplasty: Case report AJNR Am J Neuroradiol 23 2002 868-870
    • (2002) AJNR Am. J. Neuroradiol. , vol.23 , pp. 868-870
    • Scroop, R.1    Eskridge, J.2    Britz, G.W.3
  • 30
    • 0036841431 scopus 로고    scopus 로고
    • Management of pulmonary embolism during acrylic vertebroplasty
    • P. Tozzi Y. Abdelmoumene A.F. Corno, et al. Management of pulmonary embolism during acrylic vertebroplasty Ann Thorac Surg 74 2002 1706-1708
    • (2002) Ann. Thorac. Surg. , vol.74 , pp. 1706-1708
    • Tozzi, P.1    Abdelmoumene, Y.2    Corno, A.F.3
  • 32
    • 0036132596 scopus 로고    scopus 로고
    • Measurements of the solubilities and dissolution rates of several hydroxyapatites
    • M.T. Fulmer I.C. Ison C.R. Hankermayer, et al. Measurements of the solubilities and dissolution rates of several hydroxyapatites Biomaterials 23 2002 751-755
    • (2002) Biomaterials , vol.23 , pp. 751-755
    • Fulmer, M.T.1    Ison, I.C.2    Hankermayer, C.R.3
  • 33
    • 0032217161 scopus 로고    scopus 로고
    • BoneSource hydroxyapatite cement: A novel biomaterial for craniofacial skeletal tissue engineering and reconstruction
    • C.D. Friedman P.D. Costantino S. Takagi, et al. BoneSource hydroxyapatite cement: A novel biomaterial for craniofacial skeletal tissue engineering and reconstruction J Biomed Mater Res 43 1998 428-432
    • (1998) J Biomed. Mater. Res. , vol.43 , pp. 428-432
    • Friedman, C.D.1    Costantino, P.D.2    Takagi, S.3
  • 34
    • 0033814144 scopus 로고    scopus 로고
    • Diametral tensile strength and compressive strength of a calcium phosphate cement: Effect of applied pressure
    • L.C. Chow S. Hirayama S. Takagi, et al. Diametral tensile strength and compressive strength of a calcium phosphate cement: Effect of applied pressure J Biomed Mater Res 53 2000 511-517
    • (2000) J Biomed. Mater. Res. , vol.53 , pp. 511-517
    • Chow, L.C.1    Hirayama, S.2    Takagi, S.3
  • 35
    • 0032736531 scopus 로고    scopus 로고
    • Alpha-BSM: A biomimetic bone substitute and drug delivery vehicle
    • D.D. Lee A. Tofighi M. Aiolova, et al. alpha-BSM: A biomimetic bone substitute and drug delivery vehicle Clin Orthop 1999 S396-S405
    • (1999) Clin. Orthop.
    • Lee, D.D.1    Tofighi, A.2    Aiolova, M.3
  • 36
    • 4544353771 scopus 로고    scopus 로고
    • Recombinant human bone morphogenetic protein-2 delivered in an injectable calcium phosphate paste accelerates osteotomy-site healing in a nonhuman primate model
    • H.J. Seeherman M. Bouxsein H. Kim, et al. Recombinant human bone morphogenetic protein-2 delivered in an injectable calcium phosphate paste accelerates osteotomy-site healing in a nonhuman primate model J Bone Joint Surg Am 86-A 2004 1961-1972
    • (2004) J Bone Joint Surg. Am. , vol.86 A , pp. 1961-1972
    • Seeherman, H.J.1    Bouxsein, M.2    Kim, H.3
  • 37
    • 0029256548 scopus 로고
    • Skeletal repair by in situ formation of the mineral phase of bone
    • B.R. Constantz I.C. Ison M.T. Fulmer, et al. Skeletal repair by in situ formation of the mineral phase of bone Science 267 1995 1796-1799
    • (1995) Science , vol.267 , pp. 1796-1799
    • Constantz, B.R.1    Ison, I.C.2    Fulmer, M.T.3
  • 38
    • 0036169004 scopus 로고    scopus 로고
    • Use of injectable calcium phosphate cement for fracture fixation: A review
    • S. Larsson T.W. Bauer Use of injectable calcium phosphate cement for fracture fixation: A review Clin Orthop 2002 23-32
    • (2002) Clin. Orthop. , pp. 23-32
    • Larsson, S.1    Bauer, T.W.2
  • 39
    • 0031712261 scopus 로고    scopus 로고
    • Biomechanical and histological evaluation of a calcium phosphate cement
    • E.P. Frankenburg S.A. Goldstein T.W. Bauer, et al. Biomechanical and histological evaluation of a calcium phosphate cement J Bone Joint Surg Am 80 1998 1112-1124
    • (1998) J Bone Joint Surg. Am. , vol.80 , pp. 1112-1124
    • Frankenburg, E.P.1    Goldstein, S.A.2    Bauer, T.W.3
  • 40
    • 0031924185 scopus 로고    scopus 로고
    • Norian SRS cement augmentation in hip fracture treatment: Laboratory and initial clinical results
    • S.B. Goodman T.W. Bauer D. Carter, et al. Norian SRS cement augmentation in hip fracture treatment: Laboratory and initial clinical results Clin Orthop 348 1998 42-50
    • (1998) Clin. Orthop. , vol.348 , pp. 42-50
    • Goodman, S.B.1    Bauer, T.W.2    Carter, D.3
  • 41
    • 0032822564 scopus 로고    scopus 로고
    • Resorbable bone cement for augmentation of internally fixed hip fractures
    • Annales Chirurgiae et Gynaecologiae
    • S. Larsson P. Mattsson T.W. Bauer Resorbable bone cement for augmentation of internally fixed hip fractures Annales Chirurgiae et Gynaecologiae 88 1999 205-213
    • (1999) , vol.88 , pp. 205-213
    • Larsson, S.1    Mattsson, P.2    Bauer, T.W.3
  • 42
    • 0034207847 scopus 로고    scopus 로고
    • Open reduction and augmentation of internal fixation with an injectable skeletal cement for the treatment of complex calcaneal fractures
    • T.A. Schildhauer T.W. Bauer C. Josten, et al. Open reduction and augmentation of internal fixation with an injectable skeletal cement for the treatment of complex calcaneal fractures J Orthop Trauma 14 2000 309-317
    • (2000) J Orthop. Trauma , vol.14 , pp. 309-317
    • Schildhauer, T.A.1    Bauer, T.W.2    Josten, C.3
  • 43
    • 0036505001 scopus 로고    scopus 로고
    • Balloon vertebroplasty with calcium phosphate cement augmentation for direct restoration of traumatic thoracolumbar vertebral fractures
    • J.J. Verlaan W.H. van Helden F.C. Oner, et al. Balloon vertebroplasty with calcium phosphate cement augmentation for direct restoration of traumatic thoracolumbar vertebral fractures Spine 27 2002 543-548
    • (2002) Spine , vol.27 , pp. 543-548
    • Verlaan, J.J.1    van Helden, W.H.2    Oner, F.C.3
  • 44
    • 28244497583 scopus 로고    scopus 로고
    • Vertebroplasty using injectable calcium phosphate cement compared to polymethylmethacrylate in a unique canine vertebral body large defect model
    • New Orleans. Paper #267
    • Turner TM, Urban RM, Lim TH, et al. Vertebroplasty using injectable calcium phosphate cement compared to polymethylmethacrylate in a unique canine vertebral body large defect model. Trans 49th Annual Meeting of Orthopaedic Research Society; 2003; New Orleans. Paper #267.
    • (2003) Trans 49th Annual Meeting of Orthopaedic Research Society
    • Turner, T.M.1    Urban, R.M.2    Lim, T.H.3
  • 45
    • 28244484834 scopus 로고    scopus 로고
    • Comparison of injectable calcium phosphate cement and polymethylmethacrylate for use in vertebroplasty: In-vivo evaluation using an osteopenic sheep model
    • (abstr.) Presented at the 28th Annual Meeting of the Society of Biomaterials. Tampa, FL, April 24-27
    • S. Takikawa T.W. Bauer A.S. Turner, et al. Comparison of injectable calcium phosphate cement and polymethylmethacrylate for use in vertebroplasty: In-vivo evaluation using an osteopenic sheep model Presented at the 28th Annual Meeting of the Society of Biomaterials. Tampa, FL, April 24-27, 2002 231 (abstr.)
    • (2002) , pp. 231
    • Takikawa, S.1    Bauer, T.W.2    Turner, A.S.3
  • 46
    • 0035879306 scopus 로고    scopus 로고
    • Effects of bone cement volume and distribution on vertebral stiffness after vertebroplasty
    • M.A. Liebschner W.S. Rosenberg T.M. Keaveny Effects of bone cement volume and distribution on vertebral stiffness after vertebroplasty Spine 26 2001 1547-1554
    • (2001) Spine , vol.26 , pp. 1547-1554
    • Liebschner, M.A.1    Rosenberg, W.S.2    Keaveny, T.M.3
  • 47
    • 0037096636 scopus 로고    scopus 로고
    • Biomechanical evaluation of an injectable calcium phosphate cement for vertebroplasty
    • T.H. Lim G.T. Brebach S.M. Renner, et al. Biomechanical evaluation of an injectable calcium phosphate cement for vertebroplasty Spine 27 2002 1297-1302
    • (2002) Spine , vol.27 , pp. 1297-1302
    • Lim, T.H.1    Brebach, G.T.2    Renner, S.M.3
  • 48
    • 0034193632 scopus 로고    scopus 로고
    • Experimental vertebroplasty using osteoconductive granular material
    • G. Cunin H. Boissonnet H. Petite, et al. Experimental vertebroplasty using osteoconductive granular material Spine 25 2000 1070-1076
    • (2000) Spine , vol.25 , pp. 1070-1076
    • Cunin, G.1    Boissonnet, H.2    Petite, H.3
  • 49
    • 0034193728 scopus 로고    scopus 로고
    • Biomechanical evaluation of a new bone cement for use in vertebroplasty
    • S.M. Belkoff J.M. Mathis E.M. Erbe, et al. Biomechanical evaluation of a new bone cement for use in vertebroplasty Spine 25 2000 1061-1064
    • (2000) Spine , vol.25 , pp. 1061-1064
    • Belkoff, S.M.1    Mathis, J.M.2    Erbe, E.M.3
  • 50
    • 0035054442 scopus 로고    scopus 로고
    • Augmentation of mechanical properties in osteoporotic vertebral bones: A biomechanical investigation of vertebroplasty efficacy with different bone cements
    • P.F. Heini U. Berlemann M. Kaufmann, et al. Augmentation of mechanical properties in osteoporotic vertebral bones: A biomechanical investigation of vertebroplasty efficacy with different bone cements Eur Spine J 10 2001 164-171
    • (2001) Eur. Spine. J. , vol.10 , pp. 164-171
    • Heini, P.F.1    Berlemann, U.2    Kaufmann, M.3
  • 51
    • 0034951131 scopus 로고    scopus 로고
    • An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with kyphoplasty
    • S.M. Belkoff J.M. Mathis H. Deramond, et al. An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with kyphoplasty AJNR Am J Neuroradiol 22 2001 1212-1216
    • (2001) AJNR Am. J. Neuroradiol. , vol.22 , pp. 1212-1216
    • Belkoff, S.M.1    Mathis, J.M.2    Deramond, H.3
  • 52
    • 0037515472 scopus 로고    scopus 로고
    • Resorption evaluation of a large bolus of calcium sulfate in a canine medullary defect
    • T.M. Turner R.M. Urban S. Gitelis, et al. Resorption evaluation of a large bolus of calcium sulfate in a canine medullary defect Orthopedics 26 5, Suppl. 2003 577-579
    • (2003) Orthopedics , vol.26 , Issue.5 SUPPL. , pp. 577-579
    • Turner, T.M.1    Urban, R.M.2    Gitelis, S.3
  • 53
    • 28244497001 scopus 로고    scopus 로고
    • Histological evaluation of calcium sulfate HA/TCP composites using a canine metaphyseal defect model
    • Trans 50th Annual Meeting of Orthopaedic Research Society San Francisco. Poster #1040
    • Togawa D, Reid J, Bauer TW, et al. Histological evaluation of calcium sulfate HA/TCP composites using a canine metaphyseal defect model. Trans 50th Annual Meeting of Orthopaedic Research Society; 2004; San Francisco. Poster #1040.
    • (2004)
    • Togawa, D.1    Reid, J.2    Bauer, T.W.3
  • 54
    • 0037043468 scopus 로고    scopus 로고
    • Evaluation of calcium sulfate paste for augmentation of lumbar pedicle screw pullout strength
    • M.T. Rohmiller D. Schwalm R.C. Glattes, et al. Evaluation of calcium sulfate paste for augmentation of lumbar pedicle screw pullout strength Spine J 2 2002 255-260
    • (2002) Spine J. , vol.2 , pp. 255-260
    • Rohmiller, M.T.1    Schwalm, D.2    Glattes, R.C.3
  • 55
    • 0035851773 scopus 로고    scopus 로고
    • In vivo evaluation of calcium sulfate as a bone graft substitute for lumbar spinal fusion
    • P.A. Glazer U.M. Spencer R.N. Alkalay, et al. In vivo evaluation of calcium sulfate as a bone graft substitute for lumbar spinal fusion Spine J 1 2001 395-401
    • (2001) Spine J. , vol.1 , pp. 395-401
    • Glazer, P.A.1    Spencer, U.M.2    Alkalay, R.N.3
  • 56
    • 1942500920 scopus 로고    scopus 로고
    • In vivo evaluation of resorbable bone graft substitutes in a rabbit tibial defect model
    • D. Stubbs M. Deakin P. Chapman-Sheath, et al. In vivo evaluation of resorbable bone graft substitutes in a rabbit tibial defect model Biomaterials 25 2004 5037-5044
    • (2004) Biomaterials , vol.25 , pp. 5037-5044
    • Stubbs, D.1    Deakin, M.2    Chapman-Sheath, P.3
  • 57
    • 0037231525 scopus 로고    scopus 로고
    • Response of a calcium sulfate bone graft substitute in a confined cancellous defect
    • W.R. Walsh P. Morberg Y. Yu, et al. Response of a calcium sulfate bone graft substitute in a confined cancellous defect Clin Orthop 406 2003 228-236
    • (2003) Clin. Orthop. , vol.406 , pp. 228-236
    • Walsh, W.R.1    Morberg, P.2    Yu, Y.3
  • 58
    • 28244461960 scopus 로고    scopus 로고
    • In vitro evaluation of orthopedic composite cytotoxicity: Assessing the potential for postsurgical production of hydroxyl radicals
    • M. DiCicco R. Compton S.A. Jansen-Varnum In vitro evaluation of orthopedic composite cytotoxicity: Assessing the potential for postsurgical production of hydroxyl radicals J Biomed Mater Res 70B 2004 1-20
    • (2004) J Biomed. Mater. Res. , vol.70 B , pp. 1-20
    • DiCicco, M.1    Compton, R.2    Jansen-Varnum, S.A.3
  • 59
    • 0034773299 scopus 로고    scopus 로고
    • Comparison of a new bisphenol-a-glycidyl dimethacrylate-based cortical bone void filler with polymethyl methacrylate
    • E.M. Erbe T.D. Clineff G. Gualtieri Comparison of a new bisphenol-a-glycidyl dimethacrylate-based cortical bone void filler with polymethyl methacrylate Eur Spine J 10 Suppl. 2 2001 S147-S152
    • (2001) Eur. Spine J. , vol.10 , Issue.SUPPL. 2
    • Erbe, E.M.1    Clineff, T.D.2    Gualtieri, G.3
  • 60
    • 0031778659 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty with polymethylmethacrylate: Technique, indications, and results
    • H. Deramond C. Depriester P. Galibert, et al. Percutaneous vertebroplasty with polymethylmethacrylate: Technique, indications, and results Radiol Clin North Am 36 1998 533-546
    • (1998) Radiol. Clin. North. Am , vol.36 , pp. 533-546
    • Deramond, H.1    Depriester, C.2    Galibert, P.3
  • 61
    • 0017015112 scopus 로고
    • Mechanical properties of bone cements containing large doses of antibiotic powders
    • E.P. Lautenschlager J.J. Jacobs G.W. Marshall, et la. Mechanical properties of bone cements containing large doses of antibiotic powders J Biomed Mater Res 10 1976 929-938
    • (1976) J Biomed. Mater. Res. , vol.10 , pp. 929-938
    • Lautenschlager, E.P.1    Jacobs, J.J.2    Marshall, G.W.3
  • 62
    • 0017015636 scopus 로고
    • Mechanical strength of acrylic bone cements impregnated with antibiotics
    • E.P. Lautenschlager G.W. Marshall K.E. Marks, et al. Mechanical strength of acrylic bone cements impregnated with antibiotics J Biomed Mater Res 10 1976 837-845
    • (1976) J Biomed. Mater. Res. , vol.10 , pp. 837-845
    • Lautenschlager, E.P.1    Marshall, G.W.2    Marks, K.E.3
  • 63
    • 0034773733 scopus 로고    scopus 로고
    • Percutaneous transpedicular polymethylmethacrylate vertebroplasty for the treatment of spinal compression fractures
    • A.P. Amar D.W. Larsen N. Esnaashari, et al. Percutaneous transpedicular polymethylmethacrylate vertebroplasty for the treatment of spinal compression fractures Neurosurgery 49 2001 1105-1114
    • (2001) Neurosurgery , vol.49 , pp. 1105-1114
    • Amar, A.P.1    Larsen, D.W.2    Esnaashari, N.3
  • 64
    • 0019922589 scopus 로고
    • The sustained release of antimicrobial drugs from bone cement: An appraisal of laboratory investigations and their significance
    • R. Bayston R.D. Milner The sustained release of antimicrobial drugs from bone cement: An appraisal of laboratory investigations and their significance J Bone Joint Surg Br 64 1982 460-464
    • (1982) J Bone Joint Surg. Br. , vol.64 , pp. 460-464
    • Bayston, R.1    Milner, R.D.2
  • 65
    • 0026519438 scopus 로고
    • Cranioplasty using gentamicin-loaded acrylic cement: A test of neurotoxicity
    • J.F. Ronderos D.A. Wiles F.A. Ragan, et al. Cranioplasty using gentamicin-loaded acrylic cement: A test of neurotoxicity Surg Neurol 37 1992 356-360
    • (1992) Surg. Neurol. , vol.37 , pp. 356-360
    • Ronderos, J.F.1    Wiles, D.A.2    Ragan, F.A.3
  • 66
    • 0029076208 scopus 로고
    • Effect of varying surface patterns on antibiotic elution from antibiotic-loaded bone cement
    • B.A. Masri C.P. Duncan C.P. Beauchamp, et al. Effect of varying surface patterns on antibiotic elution from antibiotic-loaded bone cement J Arthroplasty 10 1995 453-459
    • (1995) J Arthroplasty , vol.10 , pp. 453-459
    • Masri, B.A.1    Duncan, C.P.2    Beauchamp, C.P.3
  • 67
    • 0034266967 scopus 로고    scopus 로고
    • In vitro elution of gentamicin, amikacin, and ceftiofur from polymethylmethacrylate and hydroxyapatite cement
    • M.T. Ethell R.A. Bennett M.P. Brown, et al. In vitro elution of gentamicin, amikacin, and ceftiofur from polymethylmethacrylate and hydroxyapatite cement Vet Surg 29 2000 375-382
    • (2000) Vet. Surg. , vol.29 , pp. 375-382
    • Ethell, M.T.1    Bennett, R.A.2    Brown, M.P.3
  • 68
    • 0036020553 scopus 로고    scopus 로고
    • Release of gentamicin sulphate from a modified commercial bone cement. Effect of (2-hydroxyethyl methacrylate) comonomer and poly(N-vinyl-2-pyrrolidone) additive on release mechanism and kinetics
    • P. Frutos E. Diez-Pena G. Frutos, et al. Release of gentamicin sulphate from a modified commercial bone cement. Effect of (2-hydroxyethyl methacrylate) comonomer and poly(N-vinyl-2-pyrrolidone) additive on release mechanism and kinetics Biomaterials 23 2002 3787-3797
    • (2002) Biomaterials , vol.23 , pp. 3787-3797
    • Frutos, P.1    Diez-Pena, E.2    Frutos, G.3
  • 69
    • 0033761357 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty in benign and malignant disease
    • K.J. Murphy H. Deramond Percutaneous vertebroplasty in benign and malignant disease Neuroimaging Clin North Am 10 2000 535-545
    • (2000) Neuroimaging Clin. North Am. , vol.10 , pp. 535-545
    • Murphy, K.J.1    Deramond, H.2
  • 71
    • 0016740277 scopus 로고
    • A characterization of polymethylmethacrylate bone cement
    • S.S. Haas G.M. Brauer G. Dickson A characterization of polymethylmethacrylate bone cement J Bone Joint Surg Am 57 1975 380-391
    • (1975) J Bone Joint Surg. Am. , vol.57 , pp. 380-391
    • Haas, S.S.1    Brauer, G.M.2    Dickson, G.3
  • 73
    • 0018594154 scopus 로고
    • The effects of barium sulfate on the polymerization temperature and shear strength of surgical simplex P
    • S.P. Combs A.S. Greenwald The effects of barium sulfate on the polymerization temperature and shear strength of surgical simplex P Clin Orthop 145 1979 287-291
    • (1979) Clin. Orthop. , vol.145 , pp. 287-291
    • Combs, S.P.1    Greenwald, A.S.2
  • 74
    • 0031028019 scopus 로고    scopus 로고
    • Radio-opaque agents in bone cement increase bone resorption
    • A.S. Sabokbar Y. Fujikawa D.W. Murray, et al. Radio-opaque agents in bone cement increase bone resorption J Bone Joint Surg Br 79 1997 129-134
    • (1997) J Bone Joint Surg. Br. , vol.79 , pp. 129-134
    • Sabokbar, A.S.1    Fujikawa, Y.2    Murray, D.W.3
  • 75
    • 0034985296 scopus 로고    scopus 로고
    • The effects of particulate bone cements at the bone-implant interface
    • J.A. Wimhurst R.A. Brooks N. Rushton The effects of particulate bone cements at the bone-implant interface J Bone Joint Surg Br 83 2001 588-592
    • (2001) J Bone Joint Surg. Br. , vol.83 , pp. 588-592
    • Wimhurst, J.A.1    Brooks, R.A.2    Rushton, N.3
  • 76
    • 0032810055 scopus 로고    scopus 로고
    • The use of an injectable, biodegradable calcium phosphate bone substitute for the prophylactic augmentation of osteoporotic vertebrae and the management of vertebral compression fractures
    • B. Bai L.M. Jazrawi F.J. Kummer, et al. The use of an injectable, biodegradable calcium phosphate bone substitute for the prophylactic augmentation of osteoporotic vertebrae and the management of vertebral compression fractures Spine 24 1999 1521-1526
    • (1999) Spine , vol.24 , pp. 1521-1526
    • Bai, B.1    Jazrawi, L.M.2    Kummer, F.J.3
  • 77
    • 0032803123 scopus 로고    scopus 로고
    • An in vitro biomechanical evaluation of bone cements used in percutaneous vertebroplasty
    • S.M. Belkoff M. Maroney D.C. Fenton, et al. An in vitro biomechanical evaluation of bone cements used in percutaneous vertebroplasty Bone 25 1999 23S-26S
    • (1999) Bone , vol.25
    • Belkoff, S.M.1    Maroney, M.2    Fenton, D.C.3
  • 78
    • 0035879117 scopus 로고    scopus 로고
    • The biomechanics of vertebroplasty: The effect of cement volume on mechanical behavior
    • S.M. Belkoff J.M. Mathis L.E. Jasper, et al. The biomechanics of vertebroplasty: The effect of cement volume on mechanical behavior Spine 26 2001 1537-1541
    • (2001) Spine , vol.26 , pp. 1537-1541
    • Belkoff, S.M.1    Mathis, J.M.2    Jasper, L.E.3
  • 79
    • 0035879286 scopus 로고    scopus 로고
    • An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with vertebroplasty
    • S.M. Belkoff J.M. Mathis L.E. Jasper, et al. An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with vertebroplasty Spine 26 2001 1542-1546
    • (2001) Spine , vol.26 , pp. 1542-1546
    • Belkoff, S.M.1    Mathis, J.M.2    Jasper, L.E.3
  • 80
    • 0035863342 scopus 로고    scopus 로고
    • An ex vivo biomechanical evaluation of an inflatable bone tamp used in the treatment of compression fracture
    • S.M. Belkoff J.M. Mathis D.C. Fenton, et al. An ex vivo biomechanical evaluation of an inflatable bone tamp used in the treatment of compression fracture Spine 26 2001 151-156
    • (2001) Spine , vol.26 , pp. 151-156
    • Belkoff, S.M.1    Mathis, J.M.2    Fenton, D.C.3
  • 81
    • 0037962372 scopus 로고    scopus 로고
    • Biomechanical effects of unipedicular vertebroplasty on intact vertebrae
    • K.B. Higgins R.D. Harten N.A. Langrana, et al. Biomechanical effects of unipedicular vertebroplasty on intact vertebrae Spine 28 2003 1540-1547
    • (2003) Spine , vol.28 , pp. 1540-1547
    • Higgins, K.B.1    Harten, R.D.2    Langrana, N.A.3
  • 82
    • 0038638438 scopus 로고    scopus 로고
    • The effect of vertebral body percentage fill on mechanical behavior during percutaneous vertebroplasty
    • S. Molloy J.M. Mathis S.M. Belkoff The effect of vertebral body percentage fill on mechanical behavior during percutaneous vertebroplasty Spine 28 2003 1549-1554
    • (2003) Spine , vol.28 , pp. 1549-1554
    • Molloy, S.1    Mathis, J.M.2    Belkoff, S.M.3
  • 83
    • 0033200346 scopus 로고    scopus 로고
    • Biomechanical efficacy of unipedicular versus bipedicular vertebroplasty for the management of osteoporotic compression fractures
    • A.G. Tohmeh J.M. Mathis D.C. Fenton, et al. Biomechanical efficacy of unipedicular versus bipedicular vertebroplasty for the management of osteoporotic compression fractures Spine 24 1999 1772-1776
    • (1999) Spine , vol.24 , pp. 1772-1776
    • Tohmeh, A.G.1    Mathis, J.M.2    Fenton, D.C.3
  • 84
    • 0037263256 scopus 로고    scopus 로고
    • Biomechanical evaluation of kyphoplasty and vertebroplasty with calcium phosphate cement in a simulated osteoporotic compression fracture
    • S. Tomita A. Kin M. Yazu, et al. Biomechanical evaluation of kyphoplasty and vertebroplasty with calcium phosphate cement in a simulated osteoporotic compression fracture J Orthop Sci 8 2003 192-197
    • (2003) J Orthop. Sci. , vol.8 , pp. 192-197
    • Tomita, S.1    Kin, A.2    Yazu, M.3
  • 85
    • 0036328899 scopus 로고    scopus 로고
    • Adjacent vertebral failure after vertebroplasty: A biomechanical investigation
    • U. Berlemann S.J. Ferguson L.P. Nolte, et al. Adjacent vertebral failure after vertebroplasty: A biomechanical investigation J Bone Joint Surg Br 84 2002 748-752
    • (2002) J Bone Joint Surg. Br. , vol.84 , pp. 748-752
    • Berlemann, U.1    Ferguson, S.J.2    Nolte, L.P.3
  • 86
    • 0032802422 scopus 로고    scopus 로고
    • The effect of monomer-to-powder ratio on the material properties of cranioplastic
    • L.E. Jasper H. Deramond J.M. Mathis, et al. The effect of monomer-to-powder ratio on the material properties of cranioplastic Bone 25 1999 27S-29S
    • (1999) Bone , vol.25
    • Jasper, L.E.1    Deramond, H.2    Mathis, J.M.3
  • 87
    • 0036774297 scopus 로고    scopus 로고
    • Percutaneous transpedicular vertebroplasty with calcium phosphate cement in the treatment of osteoporotic vertebral compression and burst fractures
    • M. Nakano N. Hirano K. Matsuura, et al. Percutaneous transpedicular vertebroplasty with calcium phosphate cement in the treatment of osteoporotic vertebral compression and burst fractures J Neurosurg 97 2002 287-293
    • (2002) J Neurosurg. , vol.97 , pp. 287-293
    • Nakano, M.1    Hirano, N.2    Matsuura, K.3
  • 88
    • 28244495019 scopus 로고    scopus 로고
    • Repair of osteoporotic vertebral compression fracture by transpedicular injection of bioactive calcium phosphate cement into the vertebral body
    • R. Takemasa H. Yamamoto, et al. Repair of osteoporotic vertebral compression fracture by transpedicular injection of bioactive calcium phosphate cement into the vertebral body Spine J 2 2002 96
    • (2002) Spine J. , vol.2 , pp. 96
    • Takemasa, R.1    Yamamoto, H.2
  • 89
    • 1642379433 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty
    • Springer New York
    • H. Deramond J.E. Dion J. Chiras Complications J.M. Mathis H. Deramond S.M. Belkoff Percutaneous vertebroplasty 2002 Springer New York 165-173
    • (2002) , pp. 165-173
    • Deramond, H.1    Dion, J.E.2    Chiras, J.3
  • 90
    • 0015955977 scopus 로고
    • 2,012 total hip arthroplasties. A study of postoperative course and early complications
    • M.B. Coventry R.D. Beckenbaugh D.R. Nolan, et al. 2,012 total hip arthroplasties. A study of postoperative course and early complications J Bone Joint Surg Am 56 1974 273-284
    • (1974) J Bone Joint Surg. Am. , vol.56 , pp. 273-284
    • Coventry, M.B.1    Beckenbaugh, R.D.2    Nolan, D.R.3
  • 91
    • 0003979031 scopus 로고
    • Systemic effects of monomer
    • E. & S. Livingstone Edinburgh and London
    • J. Charnley Systemic effects of monomer Charnley J, editor. Acrylic cement in orthopaedic surgery 1970 E. & S. Livingstone Edinburgh and London 72-78
    • (1970) , pp. 72-78
    • Charnley, J.1
  • 92
    • 0036790721 scopus 로고    scopus 로고
    • An in vivo comparison of the potential for extravertebral cement leak after vertebroplasty and kyphoplasty
    • F.M. Phillips F. Todd Wetzel I. Lieberman, et al. An in vivo comparison of the potential for extravertebral cement leak after vertebroplasty and kyphoplasty Spine 27 2002 2173-2178
    • (2002) Spine , vol.27 , pp. 2173-2178
    • Phillips, F.M.1    Todd Wetzel, F.2    Lieberman, I.3
  • 93
    • 0025604511 scopus 로고
    • Cardiopulmonary arrest following an infusion of calcium 2-amino ethanol phosphate
    • D. Sauter L. Goldfrank B.D. Charash Cardiopulmonary arrest following an infusion of calcium 2-amino ethanol phosphate J Emerg Med 8 1990 717-720
    • (1990) J Emerg. Med. , vol.8 , pp. 717-720
    • Sauter, D.1    Goldfrank, L.2    Charash, B.D.3
  • 94
    • 0032586923 scopus 로고    scopus 로고
    • Disseminated ischemic necrosis and livedo racemosa in a chronic dialysis patient with calciphylaxis
    • A. Henschel L. Dannenberg U. Gobel, et al. [Disseminated ischemic necrosis and livedo racemosa in a chronic dialysis patient with calciphylaxis] Hautarzt 50 1999 439-444
    • (1999) Hautarzt , vol.50 , pp. 439-444
    • Henschel, A.1    Dannenberg, L.2    Gobel, U.3
  • 95
    • 0030921599 scopus 로고    scopus 로고
    • Local tissue irritating effects and adjuvant activities of calcium phosphate and aluminium hydroxide with different physical properties
    • N. Goto H. Kato J. Maeyama Local tissue irritating effects and adjuvant activities of calcium phosphate and aluminium hydroxide with different physical properties Vaccine 15 1997 1364-1371
    • (1997) Vaccine , vol.15 , pp. 1364-1371
    • Goto, N.1    Kato, H.2    Maeyama, J.3
  • 96
    • 0033804654 scopus 로고    scopus 로고
    • Particulate adjuvants can induce macrophage survival, DNA synthesis, and a synergistic proliferative response to GM-CSF and CSF-1
    • J.A. Hamilton R. Byrne G. Whitty Particulate adjuvants can induce macrophage survival, DNA synthesis, and a synergistic proliferative response to GM-CSF and CSF-1 J Leukoc Biol 67 2000 226-232
    • (2000) J Leukoc. Biol. , vol.67 , pp. 226-232
    • Hamilton, J.A.1    Byrne, R.2    Whitty, G.3
  • 97
    • 0032521419 scopus 로고    scopus 로고
    • Reinforcement of thoracolumbar burst fractures with calcium phosphate cement. A biomechanical study
    • L.E. Mermelstein R.F. McLain S.A. Yerby Reinforcement of thoracolumbar burst fractures with calcium phosphate cement. A biomechanical study Spine 23 1998 664-670
    • (1998) Spine , vol.23 , pp. 664-670
    • Mermelstein, L.E.1    McLain, R.F.2    Yerby, S.A.3
  • 98
    • 0034650413 scopus 로고    scopus 로고
    • Effect of augmentation on the mechanics of vertebral wedge fractures
    • D.R. Wilson E.R. Myers J.M. Mathis, et al. Effect of augmentation on the mechanics of vertebral wedge fractures Spine 25 2000 158-165
    • (2000) Spine , vol.25 , pp. 158-165
    • Wilson, D.R.1    Myers, E.R.2    Mathis, J.M.3
  • 99
    • 0034520393 scopus 로고    scopus 로고
    • The strengthening effect of percutaneous vertebroplasty
    • J.R. Dean K.T. Ison P. Gishen The strengthening effect of percutaneous vertebroplasty Clin Radiol 55 2000 471-476
    • (2000) Clin. Radiol. , vol.55 , pp. 471-476
    • Dean, J.R.1    Ison, K.T.2    Gishen, P.3
  • 100
    • 0035118517 scopus 로고    scopus 로고
    • Mechanical augmentation of the vertebral body by calcium phosphate cement injection
    • M. Ikeuchi H. Yamamoto T. Shibata, et al. Mechanical augmentation of the vertebral body by calcium phosphate cement injection J Orthop Sci 6 2001 39-45
    • (2001) J Orthop. Sci. , vol.6 , pp. 39-45
    • Ikeuchi, M.1    Yamamoto, H.2    Shibata, T.3
  • 101
    • 0035489425 scopus 로고    scopus 로고
    • Comparison of the biomechanics of hydroxyapatite and polymethylmethacrylate vertebroplasty in a cadaveric spinal compression fracture model
    • P.W. Hitchon V. Goel J. Drake, et al. Comparison of the biomechanics of hydroxyapatite and polymethylmethacrylate vertebroplasty in a cadaveric spinal compression fracture model J Neurosurg 95 2001 215-220
    • (2001) J Neurosurg. , vol.95 , pp. 215-220
    • Hitchon, P.W.1    Goel, V.2    Drake, J.3
  • 102
    • 0037648845 scopus 로고    scopus 로고
    • The effect of cement augmentation on the load transfer in an osteoporotic functional spinal unit: Finite-element analysis
    • A. Polikeit L.P. Nolte S.J. Ferguson The effect of cement augmentation on the load transfer in an osteoporotic functional spinal unit: finite-element analysis Spine 28 2003 991-996
    • (2003) Spine , vol.28 , pp. 991-996
    • Polikeit, A.1    Nolte, L.P.2    Ferguson, S.J.3
  • 103
    • 0042737757 scopus 로고    scopus 로고
    • Load shift of the intervertebral disc after a vertebroplasty: A finite-element study
    • G. Baroud J. Nemes P. Heini, et al. Load shift of the intervertebral disc after a vertebroplasty: A finite-element study Eur Spine J 12 2003 421-426
    • (2003) Eur. Spine J. , vol.12 , pp. 421-426
    • Baroud, G.1    Nemes, J.2    Heini, P.3
  • 104
    • 3042770918 scopus 로고    scopus 로고
    • Biomechanics of prophylactic vertebral reinforcement
    • K. Sun M.A. Liebschner Biomechanics of prophylactic vertebral reinforcement Spine 29 2004 1428-1435
    • (2004) Spine , vol.29 , pp. 1428-1435
    • Sun, K.1    Liebschner, M.A.2
  • 105
    • 2542500514 scopus 로고    scopus 로고
    • Biomechanical comparison of kyphoplasty with different bone cements
    • S. Tomita S. Molloy L.E. Jasper, et al. Biomechanical comparison of kyphoplasty with different bone cements Spine 29 2004 1203-1207
    • (2004) Spine , vol.29 , pp. 1203-1207
    • Tomita, S.1    Molloy, S.2    Jasper, L.E.3
  • 106
    • 28244450221 scopus 로고    scopus 로고
    • The biomechanics of polymethylmethacrylate augmentation
    • (in press)
    • Kayanja MM, Evans K, Milks R, et al. The biomechanics of polymethylmethacrylate augmentation. Clin Orthop 2005 (in press).
    • (2005) Clin. Orthop.
    • Kayanja, M.M.1    Evans, K.2    Milks, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.