The use of detectability indices as a means of automatic exposure control for a digital mammography system

Author keywords

AEC; contrast details; detectability index; FFDM; image quality; SdNR; structured background

Indexed keywords

AEC; CONTRAST-DETAILS; DETECTABILITY INDEX; FFDM; SDNR; STRUCTURED BACKGROUND;

EID: 79955785822     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.878119     Document Type: Conference Paper
Times cited : (5)

References (21)
  • 1
    • 33750547597 scopus 로고    scopus 로고
    • X-ray spectrum optimization of full-field digital mammography: Simulation and phantom study
    • DOI 10.1118/1.2351951
    • Bernhardt, P., Mertelmeier, T., and Hoheisel, M., "X-ray spectrum optimisation of full-field digital mammography: simulation and phantom study", Med. Phys., 33, 4337-49 (2006). (Pubitemid 44673124)
    • (2006) Medical Physics , vol.33 , Issue.11 , pp. 4337-4349
    • Bernhardt, P.1    Mertelmeier, T.2    Hoheisel, M.3
  • 3
    • 21244485463 scopus 로고    scopus 로고
    • Dose to population as a metric in the design of optimised exposure control in digital mammography
    • DOI 10.1093/rpd/nch579
    • Klausz, R., and Shramchenko, N., "Dose to population as a metric in the design of optimized exposure control in digital mammography", Rad. Prot. Dosim., 114, 369-374 (2005). (Pubitemid 40883712)
    • (2005) Radiation Protection Dosimetry , vol.114 , Issue.1-3 , pp. 369-374
    • Klausz, R.1    Shramchenko, N.2
  • 4
    • 70349768389 scopus 로고    scopus 로고
    • An examination of automatic exposure control regimes for two digital radiography systems
    • Marshall, N.W., "An examination of automatic exposure control regimes for two digital radiography systems", Phys. Med. Biol., 54, 4645-4670 (2009).
    • (2009) Phys. Med. Biol. , vol.54 , pp. 4645-4670
    • Marshall, N.W.1
  • 5
    • 0021848431 scopus 로고
    • Unified SNR analysis of medical imaging systems
    • DOI 10.1088/0031-9155/30/6/001
    • Wagner, R. F., and Brown, D. G., "Unified SNR analysis of medical imaging systems", Phys. Med. Biol., 30, 489-518 (1985). (Pubitemid 15041524)
    • (1985) Physics in Medicine and Biology , vol.30 , Issue.6 , pp. 489-518
    • Wagner, R.F.1    Brown, D.G.2
  • 6
    • 77953471172 scopus 로고    scopus 로고
    • Using a NPWE model observer to assess suitable image quality for a digital mammography quality assurance programme
    • Monnin, P., Bochud, F.O., Verdun, F.R., "Using a NPWE model observer to assess suitable image quality for a digital mammography quality assurance programme", Radiat.Prot.Dosimetry, 139(1-3), 459-62 (2010).
    • (2010) Radiat.Prot.Dosimetry , vol.139 , Issue.1-3 , pp. 459-462
    • Monnin, P.1    Bochud, F.O.2    Verdun, F.R.3
  • 7
    • 0018524989 scopus 로고
    • Motion and vision II Stabilized spatio-temporal threshold surface
    • Kelly, D.H., "Motion and vision II Stabilized spatio-temporal threshold surface", J. Opt. Soc. Am., 69, 1340-9 (1979).
    • (1979) J. Opt. Soc. Am. , vol.69 , pp. 1340-1349
    • Kelly, D.H.1
  • 8
    • 0031950889 scopus 로고    scopus 로고
    • A method for measuring the presampled MTF of digital radiographic systems using an edge test device
    • DOI 10.1118/1.598165
    • Samei, E., Flynn, M.J., and Reimann, D.A., "A method for measuring the presampled MTF of digital radiographic systems using an edge test device", Med. Phys., 25, 102-13 (1998). (Pubitemid 28063694)
    • (1998) Medical Physics , vol.25 , Issue.1 , pp. 102-113
    • Samei, E.1    Flynn, M.J.2    Reimann, D.A.3
  • 9
    • 33646485572 scopus 로고    scopus 로고
    • A comparison between objective and subjective image quality measurements for a full field digital mammography system
    • Marshall, N.W., "A comparison between objective and subjective image quality measurements for a full field digital mammography system", Phys. Med. Biol., 51, 2441-63 (2006).
    • (2006) Phys. Med. Biol. , vol.51 , pp. 2441-2463
    • Marshall, N.W.1
  • 10
    • 84896078808 scopus 로고    scopus 로고
    • Calculation of quantitative image quality parameters - Notes describing the Use of OBJ-IQ-reduced
    • NHSBSP (National Health Service Breast Screening Programme),NHSBSP, Sheffield, UK
    • NHSBSP (National Health Service Breast Screening Programme) "Calculation of Quantitative Image Quality Parameters - Notes Describing the Use of OBJ-IQ-reduced", Equipment Report 0902 (NHSBSP, Sheffield, UK) (2009).
    • (2009) Equipment Report 0902
  • 12
    • 79955769454 scopus 로고    scopus 로고
    • Erica̧ software downloaded from
    • Erica̧ software, downloaded from http://www.kuleuven.ac.be/ radiology/lucmfr/erica
  • 13
    • 33745416524 scopus 로고    scopus 로고
    • Comparison of software and human observers in reading images of the CDMAM test object to assess digital mammography systems
    • Young, K.C., Cook, J.J.H., Oduko, J.M., and Bosmans, H., "Comparison of software and human observers in reading images of the CDMAM test object to assess digital mammography systems", Proc. SPIE 6142, 614206-1-13 (2006).
    • (2006) Proc. SPIE , vol.6142 , pp. 6142061-614213
    • Young, K.C.1    Cook, J.J.H.2    Oduko, J.M.3    Bosmans, H.4
  • 14
    • 68449098084 scopus 로고    scopus 로고
    • A novel method for contrast-to-noise ratio (CNR) evaluation of digital mammography detectors
    • Baldelli, P., Phelan, N., Egan, G., "A novel method for contrast-to-noise ratio (CNR) evaluation of digital mammography detectors", Eur Radiol 19, 2275-2285 (2009).
    • (2009) Eur Radiol , vol.19 , pp. 2275-2285
    • Baldelli, P.1    Phelan, N.2    Egan, G.3
  • 15
    • 18844408570 scopus 로고    scopus 로고
    • Generalized DQE analysis of radiographic and dual-energy imaging using flat-panel detectors
    • DOI 10.1118/1.1901203
    • Richard, S., Siewerdsen, J.H., Jaffray, D.A., Moseley, D.J., and Bakhtiar, B., "Generalized DQE analysis of radiographic and dual-energy imaging using flat-panel detectors", Med. Phys., 32 (5) , 1397-1413 (2005). (Pubitemid 40695783)
    • (2005) Medical Physics , vol.32 , Issue.5 , pp. 1397-1413
    • Richard, S.1    Siewerdsen, J.H.2    Jaffray, D.A.3    Moseley, D.J.4    Bakhtiar, B.5
  • 16
    • 79955824951 scopus 로고    scopus 로고
    • A novel platform to simplify human observer performance experiments in clinical reading environments
    • Jacobs, J., Zanca, F., and Bosmans, H., "A novel platform to simplify human observer performance experiments in clinical reading environments" , Proc. SPIE Medical Imaging 7960-10 (2011).
    • (2011) Proc. SPIE Medical Imaging , vol.7960 , Issue.10
    • Jacobs, J.1    Zanca, F.2    Bosmans, H.3
  • 17
    • 0033778108 scopus 로고    scopus 로고
    • Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocol
    • Dance, D.R., Skinner, C. L., Young, K.C., Beckett, J.R., and Kotre, C.J., "Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocol", Phys. Med. Biol., 45, 3225-3240 (2000).
    • (2000) Phys. Med. Biol. , vol.45 , pp. 3225-3240
    • Dance, D.R.1    Skinner, C.L.2    Young, K.C.3    Beckett, J.R.4    Kotre, C.J.5
  • 19
    • 67649871970 scopus 로고    scopus 로고
    • Detective quantum efficiency measured as a function of energy for two full field digital mammography systems
    • Marshall , N.W., " Detective quantum efficiency measured as a function of energy for two full field digital mammography systems", Phys Med Biol, 54, 2845-2861 (2009).
    • (2009) Phys Med Biol , vol.54 , pp. 2845-2861
    • Marshall, N.W.1
  • 20
    • 0031758210 scopus 로고    scopus 로고
    • The effect of background structure on the detection of low contrast objects in mammography
    • Kotre, C.J, "The effect of background structure on the detection of low contrast objects in mammography", Brit J Radiol, 71, 1162-1167 (1998). (Pubitemid 28526368)
    • (1998) British Journal of Radiology , vol.71 , Issue.NOVEMBER , pp. 1162-1167
    • Kotre, C.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.