Comparison of software and human observers in reading images of the CDMAM test object to assess digital mammography systems

Author keywords

Alternative forced choice; CDMAM phantom; Contrast detail; Digital mammography; Observer performance; Quality control

Indexed keywords

COMPUTER SOFTWARE; CURVE FITTING; IMAGE QUALITY; INTERPOLATION; MAMMOGRAPHY; QUALITY CONTROL;

EID: 33745416524     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.653296     Document Type: Conference Paper
Times cited : (83)

References (10)
  • 3
    • 33746383303 scopus 로고    scopus 로고
    • Development of minimum standards for image quality and dose in digital mammography
    • awaiting publication
    • K.C.Young, B. Johnson, H. Bosmans, R. Van Engen, "Development of minimum standards for image quality and dose in digital mammography" in Proceedings of IWDM 2004 (awaiting publication).
    • Proceedings of IWDM 2004
    • Young, K.C.1    Johnson, B.2    Bosmans, H.3    Van Engen, R.4
  • 4
    • 0042345181 scopus 로고    scopus 로고
    • Modification of the CDMAM contrast-detail phantom for image quality of Full Field Digital Mammography systems
    • M. Yaffe ed, Medical Physics Publishing, Madison, WI, Toronto
    • K.R. Bijkerk, M.A.O. Thijssen, Th.J.M. Arnoldussen, "Modification of the CDMAM contrast-detail phantom for image quality of Full Field Digital Mammography systems", in Proceedings of IWDM 2000, pp.633-640, M. Yaffe ed, Medical Physics Publishing, Madison, WI, Toronto, 2000.
    • (2000) Proceedings of IWDM 2000 , pp. 633-640
    • Bijkerk, K.R.1    Thijssen, M.A.O.2    Arnoldussen, Th.J.M.3
  • 7
    • 0038372096 scopus 로고    scopus 로고
    • The value of scatter removal by a grid in full field digital mammography
    • W.J.H. Veldkamp et al., "The value of scatter removal by a grid in full field digital mammography", Med. Phys. 30, 1712-1718 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 1712-1718
    • Veldkamp, W.J.H.1
  • 8
    • 23844452194 scopus 로고    scopus 로고
    • Quantifying the performance of human and software CDMAM phantom image observers for the qualification of digital mammography systems
    • L. Fletcher-Heath and R. Van Metter, "Quantifying the performance of human and software CDMAM phantom image observers for the qualification of digital mammography systems," in Proc SPIE Medical Imaging 2005: Physics of Medical Imaging, 5745, 486-498 (2005).
    • (2005) Proc SPIE Medical Imaging 2005: Physics of Medical Imaging , vol.5745 , pp. 486-498
    • Fletcher-Heath, L.1    Van Metter, R.2
  • 9
    • 0033778108 scopus 로고    scopus 로고
    • Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocol
    • D.R. Dance, C.L. Skinner, K.C. Young, J.R. Beckett, and C.J. Kotre, "Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocol," Phys. Med. Biol. 45, 3225-3240 (2000).
    • (2000) Phys. Med. Biol. , vol.45 , pp. 3225-3240
    • Dance, D.R.1    Skinner, C.L.2    Young, K.C.3    Beckett, J.R.4    Kotre, C.J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.