메뉴 건너뛰기




Volumn 7966, Issue , 2011, Pages

A novel platform to simplify human observer performance experiments in clinical reading environments

Author keywords

FROC; Human observer performance experiment; LROC; M AFC; Reading environment; ROC; VGA

Indexed keywords

FROC; HUMAN OBSERVER PERFORMANCE EXPERIMENT; LROC; M-AFC; READING ENVIRONMENT; ROC; VGA;

EID: 79955824951     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.878322     Document Type: Conference Paper
Times cited : (10)

References (13)
  • 1
    • 34547927219 scopus 로고    scopus 로고
    • Specificities of a psycho-physical test room dedicated for medical display applications
    • 2007 SID International Symposium - Digest of Technical Papers
    • C. Marchessoux and T. Kimpe, "Specificities of a psycho-physical test room dedicated for medical display applications", International symposium, Society for Information Display, SID 2007, Long Beach, 15.3, book II, pp. 971-974, 2007. (Pubitemid 47266372)
    • (2007) Digest of Technical Papers - SID International Symposium , vol.38 , Issue.2 , pp. 971-974
    • Marchessoux, C.1    Kimpe, T.2
  • 2
    • 79955801489 scopus 로고    scopus 로고
    • Implementation of a novel software framework for increased efficiency in observer performance studies in digital radiology
    • Jacobs J., Zanca F., Marchal G., Bosmans H., "Implementation of a Novel Software Framework for Increased Efficiency in Observer Performance Studies in Digital Radiology", Proc RSNA, 2008.
    • (2008) Proc RSNA
    • Jacobs, J.1    Zanca, F.2    Marchal, G.3    Bosmans, H.4
  • 4
    • 21244466397 scopus 로고    scopus 로고
    • Recent advances in observer performance methodology: Jackknife free-response ROC (JAFROC)
    • DOI 10.1093/rpd/nch512
    • Chakraborty, D. P. "Recent advances in observer performance methodology: jackknife free-response ROC (JAFROC)". Radiat. Prot. Dosimetry 114, 26-31 (2005). (Pubitemid 40883650)
    • (2005) Radiation Protection Dosimetry , vol.114 , Issue.1-3 , pp. 26-31
    • Chakraborty, D.P.1
  • 5
    • 34347238949 scopus 로고    scopus 로고
    • Visual grading characteristics (VGC) analysis: A non-parametric rank-invariant statistical method for image quality evaluation
    • DOI 10.1259/bjr/35012658
    • Båth, M. and Månsson, L. G. "Visual grading characteristics (VGC) analysis: a non-parametric rank-invariant statistical method for image quality evaluation". Br. J. Radiol. 80, 169-176 (2007). (Pubitemid 47007807)
    • (2007) British Journal of Radiology , vol.80 , Issue.951 , pp. 169-176
    • Bath, M.1    Mansson, L.G.2
  • 6
    • 79551701886 scopus 로고    scopus 로고
    • The varying effects of ambient lighting on low contrast detection tasks
    • M. McEntee, B. Martin, "The varying effects of ambient lighting on low contrast detection tasks", Proc. SPIE 2010; 7627-22.
    • (2010) Proc. SPIE , pp. 7627-7722
    • Mcentee, M.1    Martin, B.2
  • 7
    • 44949185622 scopus 로고    scopus 로고
    • Detection of low contrast test patterns on an LCD with different luminance and illuminance settings
    • P. Sund, M. Båth, L. Månsson, "Detection of low contrast test patterns on an LCD with different luminance and illuminance settings", Proc SPIE 2008, 6917-22.
    • (2008) Proc SPIE , pp. 6917-6922
    • Sund, P.1    Båth, M.2    Månsson, L.3
  • 9
    • 67249146206 scopus 로고    scopus 로고
    • Ambient temperature variation affects radiological diagnostic performance
    • M. McEntee, S. Gafoor, "Ambient temperature variation affects radiological diagnostic performance" Proc SPIE 2009; 7263-52.
    • (2009) Proc SPIE , pp. 7263-7352
    • Mcentee, M.1    Gafoor, S.2
  • 10
    • 77954636483 scopus 로고    scopus 로고
    • Does reader visual fatigue impact interpretation accuracy?
    • E. Krupinski, K. Berbaum, "Does reader visual fatigue impact interpretation accuracy?", Proc. SPIE 2010; 7627-21.
    • (2010) Proc. SPIE , pp. 7627-7721
    • Krupinski, E.1    Berbaum, K.2
  • 12
    • 0042352214 scopus 로고    scopus 로고
    • Psychometric qualities of a brief self-rated fatigue measure: The Fatigue Assessment Scale
    • DOI 10.1016/S0022-3999(02)00392-6, PII S0022399902003926
    • HJ Michielsen, J De Vries, GL Van Heck, "Psychometric qualities of a brief self-rated fatigue measure: The Fatigue Assessment Scale (FAS)." J Psychosom Res 2002;54:345-52. (Pubitemid 38365998)
    • (2003) Journal of Psychosomatic Research , vol.54 , Issue.4 , pp. 345-352
    • Michielsen, H.J.1    De Vries, J.2    Van Heck, G.L.3
  • 13
    • 34347388646 scopus 로고    scopus 로고
    • Preliminary validation of a new variable pattern for daily quality assurance of medical image display devices
    • (July 2007; Jul)
    • J. Jacobs, F. Rogge, J. Kotre, G. Marchal and H. Bosmans, "Preliminary validation of a new variable pattern for daily quality assurance of medical image display devices", Med. Physics (July 2007; Jul;34(7):2744-58).
    • Med. Physics , vol.34 , Issue.7 , pp. 2744-2758
    • Jacobs, J.1    Rogge, F.2    Kotre, J.3    Marchal, G.4    Bosmans, H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.