메뉴 건너뛰기




Volumn 711, Issue , 2011, Pages 327-345

MR Angiography and Arterial Spin Labelling

Author keywords

angiography; arterial spin labelling; blood flow; imaging; ischaemia; MRI; Perfusion; quantification; vasculature

Indexed keywords

ANIMAL; ARTERY; ARTICLE; BRAIN; BRAIN CIRCULATION; HISTOLOGY; HUMAN; MAGNETIC RESONANCE ANGIOGRAPHY; METHODOLOGY; PHYSIOLOGY; RADIOGRAPHY; RAT; REPRODUCIBILITY; SPIN LABELING; TIME; VASCULARIZATION;

EID: 79955666441     PISSN: 10643745     EISSN: 19406029     Source Type: Book Series    
DOI: 10.1007/978-1-61737-992-5_16     Document Type: Chapter
Times cited : (4)

References (33)
  • 1
    • 0024358353 scopus 로고
    • Intracranial circulation: Pulse-sequence considerations in three-dimensional (volume) MR angiography
    • Ruggieri, P. M., Laub, G. A., Masaryk, T. J., Modic, M. T. Intracranial circulation: Pulse-sequence considerations in three-dimensional (volume) MR angiography. Radiology 1989;171(3):785–791.
    • (1989) Radiology , vol.171 , Issue.3 , pp. 785-791
    • Ruggieri, P. M.1    Laub, G. A.2    Masaryk, T. J.3    Modic, M. T.4
  • 2
    • 0024325998 scopus 로고
    • MR angiography with two-dimensional acquisition and three-dimensional display. Work in progress
    • Keller, P. J., Drayer, B. P., Fram, E. K., Williams, K. D., Dumoulin, C. L., Souza, S. P. MR angiography with two-dimensional acquisition and three-dimensional display. Work in progress. Radiology 1989;173(2):527–532.
    • (1989) Radiology , vol.173 , Issue.2 , pp. 527-532
    • Keller, P. J.1    Drayer, B. P.2    Fram, E. K.3    Williams, K. D.4    Dumoulin, C. L.5    Souza, S. P.6
  • 3
    • 0023007579 scopus 로고
    • Magnetic resonance angiography
    • Dumoulin, C. L., Hart, H. R., Jr. Magnetic resonance angiography. Radiology 1986;161(3):717–720.
    • (1986) Radiology , vol.161 , Issue.3 , pp. 717-720
    • Dumoulin, C. L.1    Hart, H. R.2
  • 4
    • 34250788041 scopus 로고    scopus 로고
    • Clinical neuroimaging using arterial spin-labeled perfusion magnetic resonance imaging
    • Wolf, R. L., Detre, J. A. Clinical neuroimaging using arterial spin-labeled perfusion magnetic resonance imaging. Neurotherapeutics 2007;4(3):346–359.
    • (2007) Neurotherapeutics , vol.4 , Issue.3 , pp. 346-359
    • Wolf, R. L.1    Detre, J. A.2
  • 5
    • 71449107295 scopus 로고    scopus 로고
    • The QUASAR Reproducibility Study. Is arterial spin labeling ready for the prime time? Preliminary results from the QUASAR reproducibility study
    • Petersen, E. T., Golay, X. (2008) The QUASAR Reproducibility Study. Is arterial spin labeling ready for the prime time? Preliminary results from the QUASAR reproducibility study. Proceedings of 16th Meeting of ISMRM 191.
    • (2008) Proceedings of 16th Meeting of ISMRM , pp. 191
    • Petersen, E. T.1    Golay, X.2
  • 6
    • 57149104587 scopus 로고    scopus 로고
    • Continuous flow-driven inversion for arterial spin labeling using pulsed radio frequency and gradient fields
    • Dai, W., Garcia, D., de Bazelaire, C., Alsop, D. C. Continuous flow-driven inversion for arterial spin labeling using pulsed radio frequency and gradient fields. Magn Reson Med 2008;60:1488–1497.
    • (2008) Magn Reson Med , vol.60 , pp. 1488-1497
    • Dai, W.1    Garcia, D.2    de Bazelaire, C.3    Alsop, D. C.4
  • 7
    • 0031032547 scopus 로고    scopus 로고
    • Estimation of water extraction fractions in rat brain using magnetic resonance measurement of perfusion with arterial spin labeling
    • Silva, A. C., Zhang, W. G., Williams, D. S., Koretsky, A. P. Estimation of water extraction fractions in rat brain using magnetic resonance measurement of perfusion with arterial spin labeling. Magn Reson Med 1997;37: 58–68.
    • (1997) Magn Reson Med , vol.37 , pp. 58-68
    • Silva, A. C.1    Zhang, W. G.2    Williams, D. S.3    Koretsky, A. P.4
  • 8
    • 0033033852 scopus 로고    scopus 로고
    • Multislice perfusion and perfusion territory imaging in humans with separate label and image coils
    • Zaharchuk, G., Ledden, P. J., Kwong, K. K., Reese, T. G., Rosen, B. R., Wald, L. L. Multislice perfusion and perfusion territory imaging in humans with separate label and image coils. Magn Reson Med 1999; 41:1093–1098.
    • (1999) Magn Reson Med , vol.41 , pp. 1093-1098
    • Zaharchuk, G.1    Ledden, P. J.2    Kwong, K. K.3    Reese, T. G.4    Rosen, B. R.5    Wald, L. L.6
  • 9
    • 0031876165 scopus 로고    scopus 로고
    • Multisection cerebral blood flow MR imaging with continuous arterial spin labeling
    • Alsop, D. C., Detre, J. A. Multisection cerebral blood flow MR imaging with continuous arterial spin labeling. Radiology 1998;208:410–416.
    • (1998) Radiology , vol.208 , pp. 410-416
    • Alsop, D. C.1    Detre, J. A.2
  • 10
    • 0027936294 scopus 로고
    • Qualitative mapping of cerebral blood-flow and functional localization with echo-planar MR imaging and signal targeting with alternating radio-frequency
    • Edelman, R. R., Siewert, B., Darby, D. G., Thangaraj, V., Nobre, A. C., Mesulam, M. M. et al. Qualitative mapping of cerebral blood-flow and functional localization with echo-planar MR imaging and signal targeting with alternating radio-frequency. Radiology 1994;192:513–520.
    • (1994) Radiology , vol.192 , pp. 513-520
    • Edelman, R. R.1    Siewert, B.2    Darby, D. G.3    Thangaraj, V.4    Nobre, A. C.5    Mesulam, M. M.6
  • 12
    • 0031956255 scopus 로고    scopus 로고
    • Multislice imaging of quantitative cerebral perfusion with pulsed arterial spin labeling
    • Yang, Y. H., Frank, J. A., Hou, L., Ye, F. Q., Mclaughlin, A. C., Duyn, J. H. Multislice imaging of quantitative cerebral perfusion with pulsed arterial spin labeling. Magn Reson Med 1998;39:825–832.
    • (1998) Magn Reson Med , vol.39 , pp. 825-832
    • Yang, Y. H.1    Frank, J. A.2    Hou, L.3    Ye, F. Q.4    Mclaughlin, A. C.5    Duyn, J. H.6
  • 13
    • 0030923460 scopus 로고    scopus 로고
    • STAR-HASTE: Perfusion imaging without magnetic susceptibility artifact
    • Chen, Q., Siewert, B., Bly, B. M., Warach, S., Edelman, R. R. STAR-HASTE: Perfusion imaging without magnetic susceptibility artifact. Magn Reson Med 1997;38: 404–408.
    • (1997) Magn Reson Med , vol.38 , pp. 404-408
    • Chen, Q.1    Siewert, B.2    Bly, B. M.3    Warach, S.4    Edelman, R. R.5
  • 15
    • 22744443729 scopus 로고    scopus 로고
    • Single-shot 3d imaging techniques improve arterial spin labeling perfusion measurements
    • Günther, M., Oshio, K., Feinberg, D. A. Single-shot 3d imaging techniques improve arterial spin labeling perfusion measurements. Magn Reson Med 2005;54: 491–498.
    • (2005) Magn Reson Med , vol.54 , pp. 491-498
    • Günther, M.1    Oshio, K.2    Feinberg, D. A.3
  • 16
    • 0026078369 scopus 로고
    • MR angiography by multiple thin slab 3d acquisition
    • Parker, D. L., Yuan, C., Blatter, D. D. MR angiography by multiple thin slab 3d acquisition. Magn Reson Med 1991;17:434–451.
    • (1991) Magn Reson Med , vol.17 , pp. 434-451
    • Parker, D. L.1    Yuan, C.2    Blatter, D. D.3
  • 17
    • 0026720638 scopus 로고
    • Improved time-of-flight MR angiography of the brain with magnetization transfer contrast
    • Edelman, R. R., Ahn, S. S., Chien, D., Li, W., Goldmann, A., Mantello, M. et al. Improved time-of-flight MR angiography of the brain with magnetization transfer contrast. Radiology 1992;184(2):395–399.
    • (1992) Radiology , vol.184 , Issue.2 , pp. 395-399
    • Edelman, R. R.1    Ahn, S. S.2    Chien, D.3    Li, W.4    Goldmann, A.5    Mantello, M.6
  • 18
    • 0026877891 scopus 로고
    • Magnetization transfer time-of-flight magnetic resonance angiography
    • Pike, G. B., Hu, B. S., Glover, G. H., Enzmann, D. R. Magnetization transfer time-of-flight magnetic resonance angiography. Magn Reson Med 1992;25:372–379.
    • (1992) Magn Reson Med , vol.25 , pp. 372-379
    • Pike, G. B.1    Hu, B. S.2    Glover, G. H.3    Enzmann, D. R.4
  • 19
    • 0028203418 scopus 로고
    • Improved MR angiography: Magnetization transfer suppression with variable flip angle excitation and increased resolution
    • Atkinson, D., Brant-Zawadzki, M., Gillan, G., Purdy, D., Laub, G. Improved MR angiography: Magnetization transfer suppression with variable flip angle excitation and increased resolution. Radiology 1994;190(3):890–894.
    • (1994) Radiology , vol.190 , Issue.3 , pp. 890-894
    • Atkinson, D.1    Brant-Zawadzki, M.2    Gillan, G.3    Purdy, D.4    Laub, G.5
  • 21
    • 65249157062 scopus 로고    scopus 로고
    • Influences of hypothermia on the cortical blood supply by laser speckle imaging
    • (Advance online pub-lication)
    • Li, M., Miao, P., Yu, J., Qiu, Y., Zhu, Y., Tong, S. Influences of hypothermia on the cortical blood supply by laser speckle imaging. IEEE Trans Neural Syst Rehabil Eng 2009;17(2):128–134 (Advance online pub-lication).
    • (2009) IEEE Trans Neural Syst Rehabil Eng , vol.17 , Issue.2 , pp. 128-134
    • Li, M.1    Miao, P.2    Yu, J.3    Qiu, Y.4    Zhu, Y.5    Tong, S.6
  • 22
    • 0029952944 scopus 로고    scopus 로고
    • Reduced transit-time sensitivity in noninvasive magnetic resonance imaging of human cerebral blood flow
    • Alsop, D. C., Detre, J. A. Reduced transit-time sensitivity in noninvasive magnetic resonance imaging of human cerebral blood flow. J Cereb Blood Flow Metab 1996; 16:1236–1249.
    • (1996) J Cereb Blood Flow Metab , vol.16 , pp. 1236-1249
    • Alsop, D. C.1    Detre, J. A.2
  • 24
    • 0021991039 scopus 로고
    • What is the correct value for the blood-brain partition coefficient for water?
    • Herscovitch, P., Raichle, M. E. What is the correct value for the blood-brain partition coefficient for water? J Cereb Blood Flow Metab 1985;5:65–69.
    • (1985) J Cereb Blood Flow Metab , vol.5 , pp. 65-69
    • Herscovitch, P.1    Raichle, M. E.2
  • 25
    • 33645769201 scopus 로고    scopus 로고
    • In vivo measurement of the longitudinal relaxation time of arterial blood (T1a) in the mouse using a pulsed arterial spin labeling approach
    • Thomas, D. L., Lythgoe, M. F., Gadian, D. G., Ordidge, R. J. In vivo measurement of the longitudinal relaxation time of arterial blood (T1a) in the mouse using a pulsed arterial spin labeling approach. Magn Reson Med 2006;55:943–947.
    • (2006) Magn Reson Med , vol.55 , pp. 943-947
    • Thomas, D. L.1    Lythgoe, M. F.2    Gadian, D. G.3    Ordidge, R. J.4
  • 27
    • 32544441071 scopus 로고    scopus 로고
    • Model-free arterial spin labeling quantification approach for perfusion MRI
    • Petersen, E. T., Lim, T., Golay, X. Model-free arterial spin labeling quantification approach for perfusion MRI. Magn Reson Med 2006;55:219–232.
    • (2006) Magn Reson Med , vol.55 , pp. 219-232
    • Petersen, E. T.1    Lim, T.2    Golay, X.3
  • 28
    • 0030851658 scopus 로고    scopus 로고
    • Evidence for the exchange of arterial spin labeled water with tissue water in rat brain from diffusion-sensitized measurements of perfusion
    • Silva, A. C., Williams, D. S., Koretsky, A. P. Evidence for the exchange of arterial spin labeled water with tissue water in rat brain from diffusion-sensitized measurements of perfusion. Magn Reson Med 1997;38: 232–237.
    • (1997) Magn Reson Med , vol.38 , pp. 232-237
    • Silva, A. C.1    Williams, D. S.2    Koretsky, A. P.3
  • 29
    • 0031726507 scopus 로고    scopus 로고
    • Continuous assessment of perfusion by tagging including volume and water extraction (CAPTIVE): A steady-state contrast agent technique for measuring blood flow, relative blood volume fraction and the water extraction fraction
    • Zaharchuk, G., Bogdanov, A. A., Jr., Marota, J. J. A., Shimizu-Sasamata, M., Weisskoff, R. M., Kwong, K. K. et al. Continuous assessment of perfusion by tagging including volume and water extraction (CAPTIVE): A steady-state contrast agent technique for measuring blood flow, relative blood volume fraction and the water extraction fraction. Magn Reson Med 1998;40:666–678.
    • (1998) Magn Reson Med , vol.40 , pp. 666-678
    • Zaharchuk, G.1    Bogdanov, A. A.2    Marota, J. J. A.3    Shimizu-Sasamata, M.4    Weisskoff, R. M.5    Kwong, K. K.6
  • 30
    • 71949101209 scopus 로고    scopus 로고
    • Characterizing the origin of the arterial spin labelling signal in MRI using a multiecho acquisition approach
    • (Advance online publication)
    • Wells, J. A., Lythgoe, M. F., Choy, M., Gadian, D. G., Ordidge, R. J., Thomas, D. L. Characterizing the origin of the arterial spin labelling signal in MRI using a multiecho acquisition approach. J Cereb Blood Flow Metab 2009;29(11):1836–1845 (Advance online publication).
    • (2009) J Cereb Blood Flow Metab , vol.29 , Issue.11 , pp. 1836-1845
    • Wells, J. A.1    Lythgoe, M. F.2    Choy, M.3    Gadian, D. G.4    Ordidge, R. J.5    Thomas, D. L.6
  • 31
    • 41849130285 scopus 로고    scopus 로고
    • Optimal design of pulsed arterial spin labeling MRI experiments
    • Xie, J., Gallichan, D., Gunn, R. N., Jezzard, P. Optimal design of pulsed arterial spin labeling MRI experiments. Magn Reson Med 2008;59:826–834.
    • (2008) Magn Reson Med , vol.59 , pp. 826-834
    • Xie, J.1    Gallichan, D.2    Gunn, R. N.3    Jezzard, P.4
  • 32
    • 33947498513 scopus 로고    scopus 로고
    • When perfusion meets diffusion: In vivo measurement of water permeability in human brain
    • Wang, J., Fernandez-Seara, M. A., Wang, S., St Lawrence, K. S. When perfusion meets diffusion: In vivo measurement of water permeability in human brain. J Cereb Blood Flow Metab 2006;27(4):839–849.
    • (2006) J Cereb Blood Flow Metab , vol.27 , Issue.4 , pp. 839-849
    • Wang, J.1    Fernandez-Seara, M. A.2    Wang, S.3    St Lawrence, K. S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.