메뉴 건너뛰기




Volumn 711, Issue , 2011, Pages 579-593

MR-Guided Focused Ultrasound for Brain Ablation and Blood–Brain Barrier Disruption

Author keywords

blood brain barrier; drug delivery systems; Focused ultrasound; magnetic resonance imaging; MRgFUS; thermal ablation; ultrasound contrast agents

Indexed keywords

ABLATION THERAPY; ANIMAL; ARTICLE; BLOOD BRAIN BARRIER; CALIBRATION; ECHOGRAPHY; MACROMOLECULE; METHODOLOGY; MICROBUBBLE; MOUSE; NUCLEAR MAGNETIC RESONANCE IMAGING; PATHOLOGY; RAT; REPRODUCIBILITY; TEMPERATURE;

EID: 79955644505     PISSN: 10643745     EISSN: 19406029     Source Type: Book Series    
DOI: 10.1007/978-1-61737-992-5_30     Document Type: Chapter
Times cited : (18)

References (36)
  • 1
    • 33845416619 scopus 로고
    • A new method for the generation and use of focused ultrasound in experimental biology
    • Lynn, J. G., Zwemer, R. L., Chick, A. J., Miller, A. G. A new method for the generation and use of focused ultrasound in experimental biology. J Gen Physiol 1942;26: 179–193.
    • (1942) J Gen Physiol , vol.26 , pp. 179-193
    • Lynn, J.G.1    Zwemer, R.L.2    Chick, A.J.3    Miller, A.G.4
  • 2
    • 0000871653 scopus 로고
    • Histological and cerebral lesions produced by focused ultrasound
    • Lynn, J. G., Putnam, T. J. Histological and cerebral lesions produced by focused ultrasound. Am J Pathol 1944;20:637–649.
    • (1944) Am J Pathol , vol.20 , pp. 637-649
    • Lynn, J.G.1    Putnam, T.J.2
  • 3
    • 0000872778 scopus 로고
    • Production of focal destructive lesions in the central nervous system with ultrasound
    • Fry, W. J., Mosberg, W. H., Jr, Barnard, J. W., Fry, F. J. Production of focal destructive lesions in the central nervous system with ultrasound. J Neurosurg 1954;11:471–478.
    • (1954) J Neurosurg , vol.11 , pp. 471-478
    • Fry, W.J.1    Mosberg, W.H.2    Barnard, J.W.3    Fry, F.J.4
  • 4
    • 0001293828 scopus 로고
    • Precision high intensity focusing ultrasonic machines for surgery
    • Fry, F. J. Precision high intensity focusing ultrasonic machines for surgery. Am J Phys Med 1958;37:152–156.
    • (1958) Am J Phys Med , vol.37
    • Fry, F.J.1
  • 5
    • 61449240144 scopus 로고
    • Instrumentation for ultrasonic neurosurgery
    • Cosman, B. J., Hueter, T. F. Instrumentation for ultrasonic neurosurgery. Electronics 1959;5:53–57.
    • (1959) Electronics , vol.5 , pp. 53-57
    • Cosman, B.J.1    Hueter, T.F.2
  • 6
    • 0006137889 scopus 로고
    • Ultrasonic method of modifying brain structures
    • Fry, W. J., Meyers, R. Ultrasonic method of modifying brain structures. Confin Neurol 1962;22:315–327.
    • (1962) Confin Neurol , vol.22 , pp. 315-327
    • Fry, W.J.1    Meyers, R.2
  • 7
    • 0018874098 scopus 로고
    • Further studies of the transkull transmission of an intense focused ultrasonic beam: Lesion production at 500 kHz
    • Fry, F. J., Goss, S. A. Further studies of the transkull transmission of an intense focused ultrasonic beam: Lesion production at 500 kHz. Ultrasound Med Biol 1980;6:33–38.
    • (1980) Ultrasound Med Biol , vol.6 , pp. 33-38
    • Fry, F.J.1    Goss, S.A.2
  • 9
    • 0028854080 scopus 로고
    • Noninvasive MRI thermometry with the proton resonance frequency (PRF) method: In vivo results in human muscle
    • De Poorter, J., De Wagter, C., De Deene, Y., Thomsen, C., Stahlberg, F., Achten, E. Noninvasive MRI thermometry with the proton resonance frequency (PRF) method: In vivo results in human muscle. Magn Reson Med 1995;33:74–81.
    • (1995) Magn Reson Med , vol.33 , pp. 74-81
    • de Poorter, J.1    de Wagter, C.2    de Deene, Y.3    Thomsen, C.4    Stahlberg, F.5    Achten, E.6
  • 11
    • 4644312297 scopus 로고    scopus 로고
    • 500-element ultrasound phased array system for noninvasive focal surgery of the brain: A preliminary rabbit study with ex vivo human skulls
    • Hynynen, K., Clement, G. T., McDannold, N., Vykhodtseva, N., King, R., White, P. J., Vitek, S., Jolesz, F. A. 500-element ultrasound phased array system for noninvasive focal surgery of the brain: A preliminary rabbit study with ex vivo human skulls. Magn Reson Med 2004;52:100–107.
    • (2004) Magn Reson Med , vol.52 , pp. 100-107
    • Hynynen, K.1    Clement, G.T.2    McDannold, N.3    Vykhodtseva, N.4    King, R.5    White, P.J.6    Vitek, S.7    Jolesz, F.A.8
  • 12
    • 0030099527 scopus 로고    scopus 로고
    • Transporting therapeutics across the blood-brain barrier
    • Abbott, N. J., Romero, I. A. Transporting therapeutics across the blood-brain barrier. Mol Med Today 1996;2:106–113.
    • (1996) Mol Med Today , vol.2 , pp. 106-113
    • Abbott, N.J.1    Romero, I.A.2
  • 13
    • 0031965788 scopus 로고    scopus 로고
    • Outwitting the blood-brain barrier for therapeutic purposes: Osmotic opening and other means
    • Kroll, R. A., Neuwelt, E. A. Outwitting the blood-brain barrier for therapeutic purposes: Osmotic opening and other means. Neurosurgery 1998;42:1083–1099.
    • (1998) Neurosurgery , vol.42 , pp. 1083-1099
    • Kroll, R.A.1    Neuwelt, E.A.2
  • 14
    • 0037079071 scopus 로고    scopus 로고
    • Drug and gene delivery to the brain: The vascular route
    • Pardridge, W. M. Drug and gene delivery to the brain: The vascular route. Neuron 2002;36:555–558.
    • (2002) Neuron , vol.36 , pp. 555-558
    • Pardridge, W.M.1
  • 15
    • 0034876083 scopus 로고    scopus 로고
    • Noninvasive MR imaging-guided focal opening of the blood-brain barrier in rabbits
    • Hynynen, K., McDannold, N., Vykhodtseva, N., Jolesz, F. A. Noninvasive MR imaging-guided focal opening of the blood-brain barrier in rabbits. Radiology 2001;220:640–646.
    • (2001) Radiology , vol.220 , pp. 640-646
    • Hynynen, K.1    McDannold, N.2    Vykhodtseva, N.3    Jolesz, F.A.4
  • 16
    • 65449147886 scopus 로고    scopus 로고
    • An MRI-compatible system for focused ultrasound experiments in small animal models
    • Chopra, R., Curiel, L., Staruch, R., Morrison, L., Hynynen, K. An MRI-compatible system for focused ultrasound experiments in small animal models. Med Phys 2009;36:1867–1874.
    • (2009) Med Phys , vol.36 , pp. 1867-1874
    • Chopra, R.1    Curiel, L.2    Staruch, R.3    Morrison, L.4    Hynynen, K.5
  • 17
    • 4143081639 scopus 로고    scopus 로고
    • Cellular mechanisms of the blood-brain barrier opening induced by ultrasound in presence of microbubbles
    • Sheikov, N., McDannold, N., Vykhodtseva, N., Jolesz, F., Hynynen, K. Cellular mechanisms of the blood-brain barrier opening induced by ultrasound in presence of microbubbles. Ultrasound Med Biol 2004;30:979–989.
    • (2004) Ultrasound Med Biol , vol.30 , pp. 979-989
    • Sheikov, N.1    McDannold, N.2    Vykhodtseva, N.3    Jolesz, F.4    Hynynen, K.5
  • 18
    • 10044278240 scopus 로고    scopus 로고
    • Local and reversible blood-brain barrier disruption by noninvasive focused ultrasound at frequencies suitable for trans-skull sonications
    • Hynynen, K., McDannold, N., Sheikov, N. A., Jolesz, F. A., Vykhodtseva, N. Local and reversible blood-brain barrier disruption by noninvasive focused ultrasound at frequencies suitable for trans-skull sonications. Neuroimage 2005;24:12–20.
    • (2005) Neuroimage , vol.24 , pp. 12-20
    • Hynynen, K.1    McDannold, N.2    Sheikov, N.A.3    Jolesz, F.A.4    Vykhodtseva, N.5
  • 19
    • 33748483260 scopus 로고    scopus 로고
    • Focal disruption of the blood-brain barrier due to 260-kHz ultrasound bursts: A method for molecular imaging and targeted drug delivery
    • Hynynen, K., McDannold, N., Vykhodtseva, N., Raymond, S., Weissleder, R., Jolesz, F. A., Sheikov, N. Focal disruption of the blood-brain barrier due to 260-kHz ultrasound bursts: A method for molecular imaging and targeted drug delivery. J Neurosurg 2006;105:445–454.
    • (2006) J Neurosurg , vol.105 , pp. 445-454
    • Hynynen, K.1    McDannold, N.2    Vykhodtseva, N.3    Raymond, S.4    Weissleder, R.5    Jolesz, F.A.6    Sheikov, N.7
  • 20
    • 33748325638 scopus 로고    scopus 로고
    • Brain arterioles show more active vesicular transport of blood-borne tracer molecules than capillaries and venules after focused ultrasound-evoked opening of the blood-brain barrier
    • Sheikov, N., McDannold, N., Jolesz, F., Zhang, Y. Z., Tam, K., Hynynen, K. Brain arterioles show more active vesicular transport of blood-borne tracer molecules than capillaries and venules after focused ultrasound-evoked opening of the blood-brain barrier. Ultrasound Med Biol 2006;32:1399–1409.
    • (2006) Ultrasound Med Biol , vol.32 , pp. 1399-1409
    • Sheikov, N.1    McDannold, N.2    Jolesz, F.3    Zhang, Y.Z.4    Tam, K.5    Hynynen, K.6
  • 21
    • 33746851261 scopus 로고    scopus 로고
    • Noninvasive localized delivery of Herceptin to the mouse brain by MRI-guided focused ultrasound-induced blood-brain barrier disruption
    • Kinoshita, M., McDannold, N., Jolesz, F. A., Hynynen, K. Noninvasive localized delivery of Herceptin to the mouse brain by MRI-guided focused ultrasound-induced blood-brain barrier disruption. Proc Natl Acad Sci USA 2006;103:11719–11723.
    • (2006) Proc Natl Acad Sci USA , vol.103 , pp. 11719-11723
    • Kinoshita, M.1    McDannold, N.2    Jolesz, F.A.3    Hynynen, K.4
  • 22
    • 34547121440 scopus 로고    scopus 로고
    • Targeted delivery of doxorubicin to the rat brain at therapeutic levels using MRI-guided focused ultrasound
    • Treat, L. H., McDannold, N., Vykhodtseva, N., Zhang, Y., Tam, K., Hynynen, K. Targeted delivery of doxorubicin to the rat brain at therapeutic levels using MRI-guided focused ultrasound. Int J Cancer 2007;121:901–907.
    • (2007) Int J Cancer , vol.121 , pp. 901-907
    • Treat, L.H.1    McDannold, N.2    Vykhodtseva, N.3    Zhang, Y.4    Tam, K.5    Hynynen, K.6
  • 23
    • 33845675648 scopus 로고    scopus 로고
    • Noninvasive, transcranial and localized opening of the blood-brain barrier using focused ultrasound in mice
    • Choi, J. J., Pernot, M., Small, S. A., Konofagou, E. E. Noninvasive, transcranial and localized opening of the blood-brain barrier using focused ultrasound in mice. Ultrasound Med Biol 2007;33:95–104.
    • (2007) Ultrasound Med Biol , vol.33 , pp. 95-104
    • Choi, J.J.1    Pernot, M.2    Small, S.A.3    Konofagou, E.E.4
  • 24
    • 33947524046 scopus 로고    scopus 로고
    • Use of ultrasound pulses combined with definity for targeted blood-brain barrier disruption: A feasibility study
    • McDannold, N., Vykhodtseva, N., Hynynen, K. Use of ultrasound pulses combined with definity for targeted blood-brain barrier disruption: A feasibility study. Ultrasound Med Biol 2007;33:584–590.
    • (2007) Ultrasound Med Biol , vol.33 , pp. 584-590
    • McDannold, N.1    Vykhodtseva, N.2    Hynynen, K.3
  • 25
    • 42949140276 scopus 로고    scopus 로고
    • Blood-brain barrier disruption induced by focused ultrasound and circulating pre-formed microbubbles appears to be characterized by the mechanical index
    • McDannold, N., Vykhodtseva, N., Hynynen, K. Blood-brain barrier disruption induced by focused ultrasound and circulating pre-formed microbubbles appears to be characterized by the mechanical index. Ultrasound Med Biol 2008;34:834–840.
    • (2008) Ultrasound Med Biol , vol.34 , pp. 834-840
    • McDannold, N.1    Vykhodtseva, N.2    Hynynen, K.3
  • 26
    • 43849110904 scopus 로고    scopus 로고
    • Effects of acoustic parameters and ultrasound contrast agent dose on focused ultrasound induced blood-brain barrier disruption
    • McDannold, N., Vykhodtseva, N., Hynynen, K. Effects of acoustic parameters and ultrasound contrast agent dose on focused ultrasound induced blood-brain barrier disruption. Ultrasound Med Biol 2008;34: 930–937.
    • (2008) Ultrasound Med Biol , vol.34 , pp. 930-937
    • McDannold, N.1    Vykhodtseva, N.2    Hynynen, K.3
  • 27
    • 45949097554 scopus 로고    scopus 로고
    • Effect of focused ultrasound applied with an ultrasound contrast agent on the tight junctional integrity of the brain microvascular endothelium
    • Sheikov, N., McDannold, N., Sharma, S., Hynynen, K. Effect of focused ultrasound applied with an ultrasound contrast agent on the tight junctional integrity of the brain microvascular endothelium. Ultrasound Med Biol 2008;34:1093–1104.
    • (2008) Ultrasound Med Biol , vol.34 , pp. 1093-1104
    • Sheikov, N.1    McDannold, N.2    Sharma, S.3    Hynynen, K.4
  • 28
    • 34548130700 scopus 로고    scopus 로고
    • Quantitative evaluation of the use of microbubbles with transcranial focused ultrasound on blood-brain-barrier disruption
    • Yang, F. Y., Fu, W. M., Yang, R. S., Liou, H. C., Kang, K. H., Lin, W. L. Quantitative evaluation of the use of microbubbles with transcranial focused ultrasound on blood-brain-barrier disruption. Ultrasound Med Biol 2007;33:1421–1427.
    • (2007) Ultrasound Med Biol , vol.33 , pp. 1421-1427
    • Yang, F.Y.1    Fu, W.M.2    Yang, R.S.3    Liou, H.C.4    Kang, K.H.5    Lin, W.L.6
  • 29
    • 40949159717 scopus 로고    scopus 로고
    • Hemorrhage detection during focused-ultrasound induced blood-brain barrier opening by using susceptibility-weighted magnetic resonance imaging
    • Liu, H. L., Wai, Y. Y., Chen, W. S., Chen, J. C., Hsu, P. H., Wu, X. Y., Huang, W. C., Yen, T. C., Wang, J. J. Hemorrhage detection during focused-ultrasound induced blood-brain barrier opening by using susceptibility-weighted magnetic resonance imaging. Ultrasound Med Biol 2008;34: 598–606.
    • (2008) Ultrasound Med Biol , vol.34 , pp. 598-606
    • Liu, H.L.1    Wai, Y.Y.2    Chen, W.S.3    Chen, J.C.4    Hsu, P.H.5    Wu, X.Y.6    Huang, W.C.7    Yen, T.C.8    Wang, J.J.9
  • 30
    • 56249135555 scopus 로고    scopus 로고
    • Effects of transcranial ultrasound and intravenous microbubbles on blood brain barrier permeability in a large animal model
    • Xie, F., Boska, M. D., Lof, J., Uberti, M. G., Tsutsui, J. M., Porter, T. R. Effects of transcranial ultrasound and intravenous microbubbles on blood brain barrier permeability in a large animal model. Ultrasound Med Biol 2008;34:2028–2034.
    • (2008) Ultrasound Med Biol , vol.34 , pp. 2028-2034
    • Xie, F.1    Boska, M.D.2    Lof, J.3    Uberti, M.G.4    Tsutsui, J.M.5    Porter, T.R.6
  • 31
    • 0026090542 scopus 로고
    • The threshold for thermally significant cavitation in dog’s thigh muscle in vivo
    • Hynynen, K. The threshold for thermally significant cavitation in dog’s thigh muscle in vivo. Ultrasound Med Biol 1991;17: 157–169.
    • (1991) Ultrasound Med Biol , vol.17 , pp. 157-169
    • Hynynen, K.1
  • 33
    • 0032825054 scopus 로고    scopus 로고
    • Thermal dosimetry of a focused ultrasound beam in vivo by magnetic resonance imaging
    • Chung, A. H., Jolesz, F. A., Hynynen, K. Thermal dosimetry of a focused ultrasound beam in vivo by magnetic resonance imaging. Med Phys 1999;26:2017–2026.
    • (1999) Med Phys , vol.26 , pp. 2017-2026
    • Chung, A.H.1    Jolesz, F.A.2    Hynynen, K.3
  • 35
    • 33748937705 scopus 로고    scopus 로고
    • Microbubble contrast agent with focused ultrasound to create brain lesions at low power levels: MR imaging and histologic study in rabbits
    • McDannold, N., Vykhodtseva, N., Hynynen, K. Microbubble contrast agent with focused ultrasound to create brain lesions at low power levels: MR imaging and histologic study in rabbits. Radiology 2006;241: 95–106.
    • (2006) Radiology , vol.241 , pp. 95-106
    • McDannold, N.1    Vykhodtseva, N.2    Hynynen, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.