메뉴 건너뛰기




Volumn 10, Issue 3, 2011, Pages 231-242

Investigating the clinical aspects of using CT vs. CT-MRI images during organ delineation and treatment planning in prostate cancer radiotherapy

Author keywords

CT MRI images; Organ delineation; Prostate cancer radiotherapy; Radiobiological measures

Indexed keywords

ALGORITHM; ARTICLE; BLADDER; CANCER CONTROL; CANCER RADIOTHERAPY; CLINICAL ARTICLE; CLINICAL EFFECTIVENESS; CLINICAL FEATURE; COMPARATIVE STUDY; COMPUTER ASSISTED RADIOTHERAPY; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; DOSIMETRY; HUMAN; INTENSITY MODULATED RADIATION THERAPY; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PROSTATE CANCER; RADIATION DOSE; RADIATION DOSE DISTRIBUTION; RECTUM; TREATMENT PLANNING;

EID: 79955529262     PISSN: 15330346     EISSN: None     Source Type: Journal    
DOI: 10.7785/tcrt.2012.500198     Document Type: Article
Times cited : (15)

References (33)
  • 3
    • 34548250088 scopus 로고    scopus 로고
    • Magnetic resonance imaging (MRI) anatomy of the prostate and application of MRI in radiotherapy planning
    • Villeirs, G. M., De Meerleer, G. O. Magnetic resonance imaging (MRI) anatomy of the prostate and application of MRI in radiotherapy planning. Eur J Radiol 63, 361-368 (2007).
    • (2007) Eur J Radiol , vol.63 , pp. 361-368
    • Villeirs, G.M.1    de Meerleer, G.O.2
  • 5
    • 0028930114 scopus 로고
    • The normal prostate and periprostatic structures: Correlation between MR images made with an endorectal coil and cadaveric microtome sections
    • Nunes, L. W., Schiebler, M. S., Rauschning, W., Schnall, M. D., Tomaszewski, J. E., Pollack, H., Kressel, H. The normal prostate and periprostatic structures: correlation between MR images made with an endorectal coil and cadaveric microtome sections. AJR Am J Roentgenol 164, 923-927 (1995).
    • (1995) AJR Am J Roentgenol , vol.164 , pp. 923-927
    • Nunes, L.W.1    Schiebler, M.S.2    Rauschning, W.3    Schnall, M.D.4    Tomaszewski, J.E.5    Pollack, H.6    Kressel, H.7
  • 9
    • 0345257841 scopus 로고    scopus 로고
    • Reduction of dose delivered to the rectum and bulb of the penis using MRI delineation for radiotherapy of the prostate
    • Steenbakkers, R. J., Deurloo, K. E., Nowak, P. J., Lebesque, J. V., van Herk, M., Rasch, C. R. Reduction of dose delivered to the rectum and bulb of the penis using MRI delineation for radiotherapy of the prostate. Int J Radiat Oncol Biol Phys 57, 1269-1279 (2003).
    • (2003) Int J Radiat Oncol Biol Phys , vol.57 , pp. 1269-1279
    • Steenbakkers, R.J.1    Deurloo, K.E.2    Nowak, P.J.3    Lebesque, J.V.4    van Herk, M.5    Rasch, C.R.6
  • 10
    • 0003418877 scopus 로고    scopus 로고
    • ICRU Report No. 62, A supplement to ICRU Report No. 50). International Commission on Radiation Units and Measurements
    • ICRU Report No. 62. Prescribing, recording and reporting photon beam therapy (A supplement to ICRU Report No. 50). International Commission on Radiation Units and Measurements, 1-52 (1999).
    • (1999) Prescribing, Recording and Reporting Photon Beam Therapy , pp. 1-52
  • 12
    • 0034758296 scopus 로고    scopus 로고
    • Biologically effective uniform dose (D) for specification, report and comparison of dose response relations and treatment plans
    • Mavroidis, P., Lind, B. K., Brahme, A. Biologically effective uniform dose (D) for specification, report and comparison of dose response relations and treatment plans. Phys Med Biol 46, 2607-2630 (2001).
    • (2001) Phys Med Biol , vol.46 , pp. 2607-2630
    • Mavroidis, P.1    Lind, B.K.2    Brahme, A.3
  • 13
    • 0026582679 scopus 로고
    • An algorithm for maximizing the probability of complication free tumor control in radiation therapy
    • Källman, P., Lind, B. K., Brahme, A. An algorithm for maximizing the probability of complication free tumor control in radiation therapy. Phys Med Biol 37, 871-890 (1992).
    • (1992) Phys Med Biol , vol.37 , pp. 871-890
    • Källman, P.1    Lind, B.K.2    Brahme, A.3
  • 17
    • 0025043385 scopus 로고
    • Optimization of uncompli cated control for head and neck tumors
    • Ågren, A.-K., Brahme, A., Turesson, I. Optimization of uncompli cated control for head and neck tumors. Int J Radiat Oncol Biol Phys 19, 1077-1085 (1990).
    • (1990) Int J Radiat Oncol Biol Phys , vol.19 , pp. 1077-1085
    • Ågren, A.-K.1    Brahme, A.2    Turesson, I.3
  • 18
    • 0026656051 scopus 로고
    • Tumor and normal tissue responses to fractionated non uniform dose delivery
    • Källman, P., Ågren, A. K., Brahme, A. Tumor and normal tissue responses to fractionated non uniform dose delivery. Int J Radiat Biol 62, 249-262 (1992).
    • (1992) Int J Radiat Biol , vol.62 , pp. 249-262
    • Källman, P.1    Ågren, A.K.2    Brahme, A.3
  • 20
    • 0032848977 scopus 로고    scopus 로고
    • Optimization of the dose level for a given treatment plan to maximize the complication free tumor cure
    • Lind, B. K., Mavroidis, P., Hyödynmaa, S., Kappas, C. Optimization of the dose level for a given treatment plan to maximize the complication free tumor cure. Acta Oncol 38, 787-798 (1999).
    • (1999) Acta Oncol , vol.38 , pp. 787-798
    • Lind, B.K.1    Mavroidis, P.2    Hyödynmaa, S.3    Kappas, C.4
  • 21
    • 0345865033 scopus 로고    scopus 로고
    • Determination and clinical verification of dose-response parameters for esophageal stricture from head and neck radiotherapy
    • Mavroidis, P., Laurell, G., Kraepelien, T., Fernberg, J. O., Lind, B. K., Brahme, A. Determination and clinical verification of dose-response parameters for esophageal stricture from head and neck radiotherapy. Acta Oncol 42, 865-881 (2003).
    • (2003) Acta Oncol , vol.42 , pp. 865-881
    • Mavroidis, P.1    Laurell, G.2    Kraepelien, T.3    Fernberg, J.O.4    Lind, B.K.5    Brahme, A.6
  • 23
    • 1542289777 scopus 로고    scopus 로고
    • Direct segment aperture and weight optimization for Intensity-Modulated radiotherapy of prostate cancer
    • De Meerleer, G., Vakaet, L., De Gersem, W., Villeirs, G., De Neve, W. Direct segment aperture and weight optimization for Intensity-Modulated radiotherapy of prostate cancer. Strahlenther Onkol 180, 136-143 (2004).
    • (2004) Strahlenther Onkol , vol.180 , pp. 136-143
    • de Meerleer, G.1    Vakaet, L.2    de Gersem, W.3    Villeirs, G.4    de Neve, W.5
  • 24
    • 0031425697 scopus 로고    scopus 로고
    • The need for accurate target and dose specifications in conventional and conformal radiation therapy - An introduction
    • Brahme, A. The need for accurate target and dose specifications in conventional and conformal radiation therapy - An introduction. Acta Oncol 36, 789-792 (1997).
    • (1997) Acta Oncol , vol.36 , pp. 789-792
    • Brahme, A.1
  • 25
    • 0343049020 scopus 로고    scopus 로고
    • Influence of treatment technique on dose-volume histogram and normal tissue complication probability for small bowel and bladder
    • Kölbl, O., Richter, S., Flentje, M. Influence of treatment technique on dose-volume histogram and normal tissue complication probability for small bowel and bladder. Strahlenther Onkol 176, 105-111 (2000).
    • (2000) Strahlenther Onkol , vol.176 , pp. 105-111
    • Kölbl, O.1    Richter, S.2    Flentje, M.3
  • 26
    • 0037295469 scopus 로고    scopus 로고
    • Magnetic resonance imaging in the radiation treatment planning of localized prostate cancer using intra-prostatic fiducial markers for computed tomography co-registration
    • Parker, C. C., Damyanovich, A., Haycocks, T., Haider, M., Bayley, A., Catton, C. N. Magnetic resonance imaging in the radiation treatment planning of localized prostate cancer using intra-prostatic fiducial markers for computed tomography co-registration. Radiother Oncol 66, 217-224 (2003).
    • (2003) Radiother Oncol , vol.66 , pp. 217-224
    • Parker, C.C.1    Damyanovich, A.2    Haycocks, T.3    Haider, M.4    Bayley, A.5    Catton, C.N.6
  • 27
    • 61349143046 scopus 로고    scopus 로고
    • Prostate delineation using CT and MRI for radiotherapy patients with bilateral hip prostheses
    • Rosewall, T., Kong, V., Vesprini, D., Catton, C., Chung, P., Ménard, C., Bayley, A. Prostate delineation using CT and MRI for radiotherapy patients with bilateral hip prostheses. Radiother Oncol 90, 325-330 (2009).
    • (2009) Radiother Oncol , vol.90 , pp. 325-330
    • Rosewall, T.1    Kong, V.2    Vesprini, D.3    Catton, C.4    Chung, P.5    Ménard, C.6    Bayley, A.7
  • 28
    • 0347756672 scopus 로고    scopus 로고
    • The clinical value of non-coplanar photon beams in biologically optimized intensity modulated dose delivery on deep seated tumors
    • Ferreira, B. C., Svensson, R., Löf, J., Brahme, A. The clinical value of non-coplanar photon beams in biologically optimized intensity modulated dose delivery on deep seated tumors. Acta Oncol 42, 852-864 (2003).
    • (2003) Acta Oncol , vol.42 , pp. 852-864
    • Ferreira, B.C.1    Svensson, R.2    Löf, J.3    Brahme, A.4
  • 29
    • 7644244191 scopus 로고    scopus 로고
    • Pretreatment Evaluation of Prostate Cancer: Role of MR Imaging and 1H MR Spectroscopy
    • Claus, F. G., Hricak, H., Hattery, R.R. Pretreatment Evaluation of Prostate Cancer: Role of MR Imaging and 1H MR Spectroscopy. Radiograph 24, S167-S180 (2004).
    • (2004) Radiograph , vol.24
    • Claus, F.G.1    Hricak, H.2    Hattery, R.R.3
  • 30
    • 79955534712 scopus 로고    scopus 로고
    • Modalities for imaging of prostate cancer
    • Hou, A. H., Swanson, D., Barqawi, A. B. Modalities for imaging of prostate cancer. Adv Urol 818065 (2009).
    • (2009) Adv Urol , pp. 818065
    • Hou, A.H.1    Swanson, D.2    Barqawi, A.B.3
  • 33
    • 33645250038 scopus 로고    scopus 로고
    • Complications of radiotherapy: Improving the therapeutic index
    • Beasley, M., Driver, D., Dobbs, H. J. Complications of radiotherapy: improving the therapeutic index. Cancer Imag 5, 78-84 (2005).
    • (2005) Cancer Imag , vol.5 , pp. 78-84
    • Beasley, M.1    Driver, D.2    Dobbs, H.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.