메뉴 건너뛰기




Volumn 168, Issue 1, 2009, Pages 89-92

Preliminary study for determination of distal dose edge by measuring 90-deg prompt gammas with an array-type prompt gamma detection system

Author keywords

Prompt gamma; Proton range; Proton therapy

Indexed keywords

DATA ACQUISITION; RADIATION DETECTORS; SCANNING;

EID: 70350326258     PISSN: 00295450     EISSN: None     Source Type: Journal    
DOI: 10.13182/NT09-A9105     Document Type: Conference Paper
Times cited : (4)

References (13)
  • 1
    • 0040138724 scopus 로고
    • Radiological use of fast protons
    • R. WILSON, "Radiological Use of Fast Protons," Radiology, 47, 487 (1946).
    • (1946) Radiology , vol.47 , pp. 487
    • Wilson., R.1
  • 2
    • 0037306264 scopus 로고    scopus 로고
    • Particle beams for cancer therapy
    • DOI 10.1053/clon.2002.0185
    • W. K. WEYRATHER and J. DEBUS, "Particle Beams for Cancer Therapy," Clin. Oncol., 15, 23 (2003). (Pubitemid 36150161)
    • (2003) Clinical Oncology , vol.15 , Issue.1
    • Weyrather, W.K.1    Debus, J.2
  • 3
    • 0018224762 scopus 로고
    • Visualization and transport of positron emission from proton activation in Vivo
    • G. W. BENNETT, J. O. ARCHAMBEAU, B. E. ARCHAMBEAU, J. I. MELTZER, and C. L. WINGATE, "Visualization and Transport of Positron Emission from Proton Activation In Vivo," Science, 200, 1151 (1978).
    • (1978) Science , vol.200 , pp. 1151
    • Bennett, G.W.1    Archambeau, J.O.2    Archambeau, B.E.3    Meltzer, J.I.4    Wingate, C.L.5
  • 5
    • 0033769670 scopus 로고    scopus 로고
    • Potential application of PET in quality assurance of proton therapy
    • DOI 10.1088/0031-9155/45/11/403, PII S0031915500141405
    • K. PARODI and T. BORTFELD, "Potential Application of PET in Quality Assurance of Proton Therapy," Phys. Med. Biol., 45, N151 (2000). (Pubitemid 30836605)
    • (2000) Physics in Medicine and Biology , vol.45 , Issue.11
    • Parodi, K.1    Enghardt, W.2
  • 7
    • 34249684860 scopus 로고    scopus 로고
    • Clinical CT-based calculations of dose and positron emitter distributions in proton therapy using the FLUKA Monte Carlo code
    • DOI 10.1088/0031-9155/52/12/004, PII S0031915507384534, 004
    • K. PARODI, A. FERRARI, F. SOMMERER, and H. PAGANETTI, "Clinical CT-Based Calculations of Dose and Positron Emitter Distributions in Proton Therapy Using the FLUKA Monte Carlo Code," Phys. Med. Biol., 52, 3369 (2007). (Pubitemid 46830631)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.12 , pp. 3369-3387
    • Parodi, K.1    Ferrari, A.2    Sommerer, F.3    Paganetti, H.4
  • 8
    • 34250197939 scopus 로고    scopus 로고
    • Simulation studies on the correlation of distal dose falloff of a 70-MeV proton beam with prompt gamma distribution
    • C. H. KIM, C. H. MIN, K. S. SEO, and J. W. KIM, "Simulation Studies on the Correlation of Distal Dose Falloff of a 70-MeV Proton Beam with Prompt Gamma Distribution," J. Korean Phys. Soc., 50, 5, 1510 (2007).
    • (2007) J. Korean Phys. Soc. , vol.50 , Issue.5 , pp. 1510
    • Kim, C.H.1    Min, C.H.2    Seo, K.S.3    Kim., J.W.4
  • 9
    • 33646387747 scopus 로고    scopus 로고
    • 2) and paraffin as neutron moderator material in a prompt gamma scanning system
    • K. S. SEO, C. H. KIM, and J. W. KIM, "Comparison of Titanium Hydride (TiH2) and Paraffin as Neutron Moderator Material in a Prompt Gamma Scanning System," J. Korean Phys. Soc., 48, 4, 855 (2006).
    • (2006) J. Korean Phys. Soc. , vol.48 , Issue.4 , pp. 855
    • Seo, K.S.1    Kim, C.H.2    Kim., J.W.3
  • 10
    • 33750744100 scopus 로고    scopus 로고
    • Prompt gamma measurements for locating the dose fall-off region in the proton therapy
    • C. H. MIN, C. H. KIM, M. Y. YOUN, and J. W. KIM, "Prompt Gamma Measurements for Locating the Dose Fall-Off Region in the Proton Therapy," Appl. Phys. Lett., 89, 183517 (2006).
    • (2006) Appl. Phys. Lett. , vol.89 , pp. 183517
    • Min, C.H.1    Kim, C.H.2    Youn, M.Y.3    Kim., J.W.4
  • 11
    • 34548227965 scopus 로고    scopus 로고
    • Determination of distal dose edge location by measuring right-angled prompt gamma-rays from a 38 MeV proton beam
    • C. H. MIN, J. W. KIM, M. Y. YOUN, and C. H. KIM, "Determination of Distal Dose Edge Location by Measuring Right-Angled Prompt Gamma-Rays from a 38 MeV Proton Beam," Nucl. Instrum. Methods A, 580, 1, 562 (2007).
    • (2007) Nucl. Instrum. Methods A , vol.580 , Issue.1 , pp. 562
    • Min, C.H.1    Kim, J.W.2    Youn, M.Y.3    Kim., C.H.4
  • 12
    • 41949100608 scopus 로고    scopus 로고
    • Development of an array-type prompt gamma detection system for the online measurement of the range of the proton beam in a patient: A monte carlo feasibility study
    • C. H. MIN, J. G. PARK, and C. H. KIM, "Development of an Array-Type Prompt Gamma Detection System for the Online Measurement of the Range of the Proton Beam in a Patient: A Monte Carlo Feasibility Study," J. Korean Phys. Soc., 52, 3, 888 (2008).
    • (2008) J. Korean Phys. Soc. , vol.52 , Issue.3 , pp. 888
    • Min, C.H.1    Park, J.G.2    Kim., C.H.3
  • 13
    • 84912003231 scopus 로고    scopus 로고
    • Determination of optimal energy window for measurement of prompt gammas from proton beam by monte carlo simulations
    • C. H. MIN, J. G. PARK, S. H. AN, and C. H. KIM, "Determination of Optimal Energy Window for Measurement of Prompt Gammas from Proton Beam by Monte Carlo Simulations," J. Nucl. Sci. Technol., S5, 28 (2008).
    • (2008) J. Nucl. Sci. Technol. , vol.S5 , pp. 28
    • Min, C.H.1    Park, J.G.2    An, S.H.3    Kim., C.H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.