메뉴 건너뛰기




Volumn 25, Issue 2, 2006, Pages 203-205

Quantitative anatomical differences in central corneal thickness values determined with scanning-slit corneal topography and noncontact specular microscopy

Author keywords

Central corneal thickness; Noncontact specular microscopy; Orbscan pachymetry; Scanning slit corneal topography

Indexed keywords

ADULT; ARTICLE; CONTROLLED STUDY; CORNEA THICKNESS; DEVICE; DIAGNOSTIC IMAGING; HUMAN; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; NONCONTACT SPECULAR MICROSCOPY; PRIORITY JOURNAL; QUANTITATIVE DIAGNOSIS; SCANNING SLIT CORNEA TOPOGRAPHY; SPECULAR MICROSCOPY; TOPOGRAPHY;

EID: 33644843307     PISSN: 02773740     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.ico.0000176605.72129.2c     Document Type: Article
Times cited : (13)

References (19)
  • 1
    • 4744362412 scopus 로고    scopus 로고
    • Anatomic study of the corneal thickness of young emmetropic subjects
    • Sanchis-Gimeno JA, Llcó-Pérez A, Alonso L, et al. Anatomic study of the corneal thickness of young emmetropic subjects. Cornea. 2004;23:669-673.
    • (2004) Cornea , vol.23 , pp. 669-673
    • Sanchis-Gimeno, J.A.1    Llcó-Pérez, A.2    Alonso, L.3
  • 2
    • 0027054040 scopus 로고
    • Short-term effects of proparacaine on human corneal thickness
    • Herse P, Siu A. Short-term effects of proparacaine on human corneal thickness. Acta Ophthalmol (Copenh). 1992;70:740-744.
    • (1992) Acta Ophthalmol (Copenh) , vol.70 , pp. 740-744
    • Herse, P.1    Siu, A.2
  • 3
    • 0032798810 scopus 로고    scopus 로고
    • Corneal thickness measurements with the Topcon SP 2000P specular microscope and ultrasound pachymeter
    • Bovelle R, Kaufman SC, Thompson HW, et al. Corneal thickness measurements with the Topcon SP 2000P specular microscope and ultrasound pachymeter. Arch Ophthalmol. 1999;177:868-870.
    • (1999) Arch Ophthalmol , vol.177 , pp. 868-870
    • Bovelle, R.1    Kaufman, S.C.2    Thompson, H.W.3
  • 4
    • 0034495233 scopus 로고    scopus 로고
    • Central and peripheral corneal thickness measured with the Topcon specular microscope SP-2000P
    • Cho P, Cheung SW. Central and peripheral corneal thickness measured with the Topcon specular microscope SP-2000P. Curr Eye Res. 2000;21: 799-807.
    • (2000) Curr Eye Res , vol.21 , pp. 799-807
    • Cho, P.1    Cheung, S.W.2
  • 5
    • 0034806668 scopus 로고    scopus 로고
    • Corneal thickness measurements with contact and non-contact specular microscopic and ultrasonic pachymetry
    • Modis L, Langenbucher A, Seitz B. Corneal thickness measurements with contact and non-contact specular microscopic and ultrasonic pachymetry. Am J Ophthalmol. 2001;132:517-521.
    • (2001) Am J Ophthalmol , vol.132 , pp. 517-521
    • Modis, L.1    Langenbucher, A.2    Seitz, B.3
  • 6
    • 0036798205 scopus 로고    scopus 로고
    • Conical endothelial cell density and pachymetry measured by contact and non-contact specular microscopy
    • Modis L Jr, Langenbucher A, Seitz B. Conical endothelial cell density and pachymetry measured by contact and non-contact specular microscopy. J Cataract Refract Surg. 2002;28:1763-1769.
    • (2002) J Cataract Refract Surg , vol.28 , pp. 1763-1769
    • Modis Jr., L.1    Langenbucher, A.2    Seitz, B.3
  • 7
    • 1642633910 scopus 로고    scopus 로고
    • Inter-observer variability of central corneal thickness measurements by using non contact specular microscopy after laser in situ keratomileusis
    • Sanchis-Gimeno JA, Lleó-Pérez A, Alonso L, et al. Inter-observer variability of central corneal thickness measurements by using non contact specular microscopy after laser in situ keratomileusis. Clin Exp Optom. 2004;87:15-18.
    • (2004) Clin Exp Optom , vol.87 , pp. 15-18
    • Sanchis-Gimeno, J.A.1    Lleó-Pérez, A.2    Alonso, L.3
  • 8
    • 0042201932 scopus 로고    scopus 로고
    • Corneal thickness measurements: Scanning-slit corneal topography and noncontact specular microscopy versus ultrasonic pachymetry
    • Suzuki S, Oshika T, Oki K, et al. Corneal thickness measurements: scanning-slit corneal topography and noncontact specular microscopy versus ultrasonic pachymetry. J Cataract Refract Surg. 2003;29:1313-1318.
    • (2003) J Cataract Refract Surg , vol.29 , pp. 1313-1318
    • Suzuki, S.1    Oshika, T.2    Oki, K.3
  • 9
    • 1842609805 scopus 로고    scopus 로고
    • Comparison of corneal thickness measurements using Orbscan II, non-contact specular microscopy, and ultrasonic pachymetry in eyes after laser in situ keratomileusis
    • Kawana K, Tokunaga T, Miyata K, et al. Comparison of corneal thickness measurements using Orbscan II, non-contact specular microscopy, and ultrasonic pachymetry in eyes after laser in situ keratomileusis. Br J Ophthalmol. 2004;88:466-468.
    • (2004) Br J Ophthalmol , vol.88 , pp. 466-468
    • Kawana, K.1    Tokunaga, T.2    Miyata, K.3
  • 10
    • 0032767869 scopus 로고    scopus 로고
    • Evaluation of corneal thickness and topography in normal eyes using the Orbscan corneal system
    • Liu Z, Huang AJ, Pflugfelder SC. Evaluation of corneal thickness and topography in normal eyes using the Orbscan corneal system. Br J Ophthalmol. 1999;83:774-778.
    • (1999) Br J Ophthalmol , vol.83 , pp. 774-778
    • Liu, Z.1    Huang, A.J.2    Pflugfelder, S.C.3
  • 11
    • 0035737828 scopus 로고    scopus 로고
    • Scanning-slit and specular microscopic pachymetry in comparison with ultrasonic determination of corneal thickness
    • Modis L Jr, Langenbucher A, Seitz B. Scanning-slit and specular microscopic pachymetry in comparison with ultrasonic determination of corneal thickness. Cornea. 2001;20:711-714.
    • (2001) Cornea , vol.20 , pp. 711-714
    • Modis Jr., L.1    Langenbucher, A.2    Seitz, B.3
  • 12
    • 0345700298 scopus 로고    scopus 로고
    • Differences in corneal anatomy in a pair of monozygotic twins due to continuous contact lens wear
    • Sanchis-Gimeno JA, Lleó-Pérez A, Alonso L, et al. Differences in corneal anatomy in a pair of monozygotic twins due to continuous contact lens wear. Cornea. 2003;22:242-245.
    • (2003) Cornea , vol.22 , pp. 242-245
    • Sanchis-Gimeno, J.A.1    Lleó-Pérez, A.2    Alonso, L.3
  • 13
    • 0037363681 scopus 로고    scopus 로고
    • Orbscan corneal topography system in evaluating the anterior structures of the human eye
    • Cosar CB, Sener AB. Orbscan corneal topography system in evaluating the anterior structures of the human eye. Cornea. 2003;22:118-121.
    • (2003) Cornea , vol.22 , pp. 118-121
    • Cosar, C.B.1    Sener, A.B.2
  • 14
    • 0042344722 scopus 로고    scopus 로고
    • Corneal thickness values before and after oxybuprocaine 0.4% eye drops
    • Asensio I, Rahhal SM, Alonso L, et al. Corneal thickness values before and after oxybuprocaine 0.4% eye drops. Cornea. 2003;22: 527-532.
    • (2003) Cornea , vol.22 , pp. 527-532
    • Asensio, I.1    Rahhal, S.M.2    Alonso, L.3
  • 15
    • 4744346127 scopus 로고    scopus 로고
    • Evaluation of normal corneas using the scanning-slit topography/ pachymetry system
    • Modis L Jr, Langenbucher A, Seitz B. Evaluation of normal corneas using the scanning-slit topography/pachymetry system. Cornea. 2004;23:689-694.
    • (2004) Cornea , vol.23 , pp. 689-694
    • Modis Jr., L.1    Langenbucher, A.2    Seitz, B.3
  • 16
    • 11144228247 scopus 로고    scopus 로고
    • Reduced corneal thickness values in postmenopausal women with dry eye
    • Sanchis-Gimeno JA, Lleo-Perez A, Alonso L, et al. Reduced corneal thickness values in postmenopausal women with dry eye. Cornea. 2005; 24:39-44.
    • (2005) Cornea , vol.24 , pp. 39-44
    • Sanchis-Gimeno, J.A.1    Lleo-Perez, A.2    Alonso, L.3
  • 17
    • 0036562697 scopus 로고    scopus 로고
    • Confocal microscopic observations of the human cornea following overnight contact lens wear
    • Efron N, Mutalib HA, Perez-Gomez I, et al. Confocal microscopic observations of the human cornea following overnight contact lens wear. Clin Exp Optom. 2002;85:149-455.
    • (2002) Clin Exp Optom , vol.85 , pp. 149-455
    • Efron, N.1    Mutalib, H.A.2    Perez-Gomez, I.3
  • 19
    • 13444287949 scopus 로고    scopus 로고
    • Refractive surgery in the United States Army, 2000-2003
    • Hammond MD, Madigan WP Jr, Bower KS. Refractive surgery in the United States Army, 2000-2003. Ophthalmology. 2005;112:184-190.
    • (2005) Ophthalmology , vol.112 , pp. 184-190
    • Hammond, M.D.1    Madigan Jr., W.P.2    Bower, K.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.