메뉴 건너뛰기




Volumn 16, Issue 2, 2011, Pages 156-164

Automated versus manual measurement of the QT interval and corrected QT interval

Author keywords

automated measurement; differential threshold method; manual measurement; QT interval; tangent method

Indexed keywords

ADULT; ARTICLE; COMPARATIVE STUDY; DATA ANALYSIS SOFTWARE; DIAGNOSTIC VALUE; DIFFERENTIAL THRESHOLD; FEMALE; HEART BEAT; HUMAN; HUMAN EXPERIMENT; MALE; MEDICAL PARAMETERS; NOISE; NORMAL HUMAN; PRIORITY JOURNAL; QT INTERVAL; QT INTERVAL ANALYSIS SOFTWARE; T WAVE AMPLITUDE; TANGENT METHOD;

EID: 79955033373     PISSN: 1082720X     EISSN: 1542474X     Source Type: Journal    
DOI: 10.1111/j.1542-474X.2011.00423.x     Document Type: Article
Times cited : (34)

References (14)
  • 1
    • 26944438354 scopus 로고    scopus 로고
    • Drugs, QTc interval prolongation and final ICH E14 guideline: An important milestone with challenges ahead
    • DOI 10.2165/00002018-200528110-00003
    • Shah RR,. Drugs, QTc interval prolongation and final ICH E14 guideline: An important milestone with challenges ahead. Drug Saf 2005; 28: 1009-1028. (Pubitemid 41483706)
    • (2005) Drug Safety , vol.28 , Issue.11 , pp. 1009-1028
    • Shah, R.R.1
  • 2
    • 21344463329 scopus 로고    scopus 로고
    • Refining detection of drug-induced proarrhythmia: QT interval and TRIaD
    • DOI 10.1016/j.hrthm.2005.03.023, PII S1547527105014451
    • Shah RR, Hondeghem LM,. Refining detection of drug-induced proarrhythmia: QT interval and TRIaD. Heart Rhythm 2005; 2: 758-772. (Pubitemid 40903686)
    • (2005) Heart Rhythm , vol.2 , Issue.7 , pp. 758-772
    • Shah, R.R.1    Hondeghem, L.M.2
  • 6
    • 79955040385 scopus 로고    scopus 로고
    • How to evaluate drug related QT interval prolongation? Current practice and issues associated with QT interval measurements
    • Kato T,. How to evaluate drug related QT interval prolongation? Current practice and issues associated with QT interval measurements. Shinzo 2006; 38: 4-8.
    • (2006) Shinzo , vol.38 , pp. 4-8
    • Kato, T.1
  • 7
    • 79954998660 scopus 로고    scopus 로고
    • Electrocardiographic changes of QT prolongation syndrome
    • Kato T,. Electrocardiographic changes of QT prolongation syndrome. Jpn J Electrocardiol 2008; 28 (Suppl 2): 5-19.
    • (2008) Jpn J Electrocardiol , vol.28 , Issue.SUPPL. 2 , pp. 5-19
    • Kato, T.1
  • 8
    • 58449130444 scopus 로고    scopus 로고
    • Automatic extraction of ECG strips from continuous 12-lead Holter recordings for QT analysis at prescheduled versus optimized time points
    • Badilini F, Vaglio M, Sarapa N,. Automatic extraction of ECG strips from continuous 12-lead Holter recordings for QT analysis at prescheduled versus optimized time points. Ann Noninvasive Electrocardiol 2009; 14 (Suppl 1): S22-S29.
    • (2009) Ann Noninvasive Electrocardiol , vol.14 , Issue.SUPPL. 1
    • Badilini, F.1    Vaglio, M.2    Sarapa, N.3
  • 9
    • 71649088627 scopus 로고    scopus 로고
    • Two automatic QT algorithms compared with manual measurement in identification of long QT syndrome
    • Diamant UB, Windo A, Stattin EL, et al,. Two automatic QT algorithms compared with manual measurement in identification of long QT syndrome. J Electrocardiol 2010; 43: 25-30.
    • (2010) J Electrocardiol , vol.43 , pp. 25-30
    • Diamant, U.B.1    Windo, A.2    Stattin, E.L.3
  • 10
    • 26844448573 scopus 로고    scopus 로고
    • Accuracy of popular automatic QT interval algorithms assessed by a 'gold standard' and comparison with a novel method: Computer simulation study
    • Hunt AC,. Accuracy of popular automatic QT interval algorithms assessed by a 'gold standard' and comparison with a novel method: Computer simulation study. BMC Cardiovasc Disord 2005; 5: 29-44.
    • (2005) BMC Cardiovasc Disord , vol.5 , pp. 29-44
    • Hunt, A.C.1
  • 11
    • 33644945905 scopus 로고    scopus 로고
    • QT interval measurement: Evaluation of automatic QTc measurement and new simple method to calculate and interpret corrected QT interval
    • Charbit B, Samain E, Merckx P, Funk-Brentano C,. QT interval measurement: Evaluation of automatic QTc measurement and new simple method to calculate and interpret corrected QT interval. Anesthesiology 2006; 104: 255-260.
    • (2006) Anesthesiology , vol.104 , pp. 255-260
    • Charbit, B.1    Samain, E.2    Merckx, P.3    Funk-Brentano, C.4
  • 12
    • 1542401221 scopus 로고    scopus 로고
    • Malfunction of the automatic slope adjustment of the QT sensor in patients with normal QT intervals
    • DOI 10.1111/j.1540-8159.2004.00452.x
    • Ruiter JH, Barrett MJ, Weteling L, et al,. Malfunction of the automatic slope adjustment of the QT sensor in patients with normal QT intervals. Pacing Clin Electrophysiol 2004; 27: 405-407. (Pubitemid 38352526)
    • (2004) PACE - Pacing and Clinical Electrophysiology , vol.27 , Issue.3 , pp. 405-407
    • Ruiter, J.H.1    Barrett, M.J.2    Weteling, L.3    Jansen, R.4
  • 13
    • 0029014582 scopus 로고
    • Comparison of automatic QT measurement techniques in the normal 12-lead electrocardiogram
    • McLaughlin NB, Campbell RW, Murray A,. Comparison of automatic QT measurement techniques in the normal 12-lead electrocardiogram. Br Heart J 1995; 74: 84-89.
    • (1995) Br Heart J , vol.74 , pp. 84-89
    • McLaughlin, N.B.1    Campbell, R.W.2    Murray, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.