Malfunction of the automatic slope adjustment of the QT sensor in patients with normal QT intervals

Author keywords

24 hour Holter; Pacemaker tachycardia; QT prolongation; QT sensor; QT window; T wave

Indexed keywords

ARTICLE; ARTIFICIAL HEART PACEMAKER; BIOSENSOR; CASE REPORT; CLINICAL FEATURE; DISEASE COURSE; FEMALE; FOLLOW UP; HEART ARRHYTHMIA; HEART ASSIST DEVICE; HISTOGRAM; HOLTER MONITORING; HUMAN; QT INTERVAL; TREATMENT OUTCOME;

EID: 1542401221     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.2004.00452.x     Document Type: Article
Times cited : (6)

References (4)
  • 1
    • 0032899281 scopus 로고    scopus 로고
    • Rate Adaptive dual chamber pacing: Inappropriate rate response due to pseudo-malfunction of the QT Biosensor
    • Dionisio P, Stroobrandt R, Vandenbulcke F, et al. Rate Adaptive dual chamber pacing: Inappropriate rate response due to pseudo-malfunction of the QT Biosensor. PACE 1999; 22:668-671.
    • (1999) PACE , vol.22 , pp. 668-671
    • Dionisio, P.1    Stroobrandt, R.2    Vandenbulcke, F.3
  • 2
    • 0029993815 scopus 로고    scopus 로고
    • Comparison of continuously recorded sensor and sinus rates during daily life activities and standardized exercise testing: Efficacy of automatically optimized rate adaptive dual sensor pacing to simulate sinus rhythm
    • Lau CP, Leung SK, Guerola M, et al. Comparison of continuously recorded sensor and sinus rates during daily life activities and standardized exercise testing: Efficacy of automatically optimized rate adaptive dual sensor pacing to simulate sinus rhythm. PACE 1996; 19:1672-1677.
    • (1996) PACE , vol.19 , pp. 1672-1677
    • Lau, C.P.1    Leung, S.K.2    Guerola, M.3
  • 3
    • 0029790920 scopus 로고    scopus 로고
    • Delayed exercise rate response kinetics due to sensor cross-checking in a dual sensor rate adaptive pacing system: The importance of individual sensor programming
    • Lau CP, Leung SK, Lee IS. Delayed exercise rate response kinetics due to sensor cross-checking in a dual sensor rate adaptive pacing system: The importance of individual sensor programming. PACE 1996; 19:1021-1025.
    • (1996) PACE , vol.19 , pp. 1021-1025
    • Lau, C.P.1    Leung, S.K.2    Lee, I.S.3
  • 4
    • 0037126076 scopus 로고    scopus 로고
    • Sex-selective QT prolongation during rapid eye movement sleep
    • Lanfranchi PA, Shamsuzzaman BBS, Ackerman MJ, et al. Sex-selective QT prolongation during rapid eye movement sleep. Circulation 2002; 106:1488-1492.
    • (2002) Circulation , vol.106 , pp. 1488-1492
    • Lanfranchi, P.A.1    Shamsuzzaman, B.B.S.2    Ackerman, M.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.