메뉴 건너뛰기




Volumn 144, Issue 1-4, 2011, Pages 571-574

Overview of physical and biophysical techniques for accident dosimetry

Author keywords

[No Author keywords available]

Indexed keywords


EID: 79953813953     PISSN: 01448420     EISSN: 17423406     Source Type: Journal    
DOI: 10.1093/rpd/ncq341     Document Type: Article
Times cited : (47)

References (23)
  • 1
    • 44949221146 scopus 로고    scopus 로고
    • Physical dosimetric reconstruction of a radiological accident due to gammagraphy equipment that occured in Dakar and Abidjan in summer 2006
    • Clairand, I., Huet, C., Trompier, F. and Bottollier-Depois, J.-F. Physical dosimetric reconstruction of a radiological accident due to gammagraphy equipment that occured in Dakar and Abidjan in summer 2006. Radiat. Meas. 43, 698-703 (2008).
    • (2008) Radiat. Meas. , vol.43 , pp. 698-703
    • Clairand, I.1    Huet, C.2    Trompier, F.3    Bottollier-Depois, J.-F.4
  • 2
    • 33749683552 scopus 로고    scopus 로고
    • Ex vivo ESR measurements associated with Monte Carlo calculations for accident dosimetry: application to the 2001 Georgian accident
    • Clairand, I., Trompier, F., Bottollier-Depois, J.-F. and Gourmelon, P. Ex vivo ESR measurements associated with Monte Carlo calculations for accident dosimetry: application to the 2001 Georgian accident. Radiat. Prot. Dosim. 119, 500-505 (2006).
    • (2006) Radiat. Prot. Dosim. , vol.119 , pp. 500-505
    • Clairand, I.1    Trompier, F.2    Bottollier-Depois, J.-F.3    Gourmelon, P.4
  • 3
    • 60249088132 scopus 로고    scopus 로고
    • Monte Carlo dose reconstruction in case of a radiological accident: application to the accident in Chile in December 2005
    • Huet, C., Clairand, I., Trompier, F., Bey, E. and Bottollier-Depois, J.-F. Monte Carlo dose reconstruction in case of a radiological accident: application to the accident in Chile in December 2005. Radioprotection 42, 489-500 (2007).
    • (2007) Radioprotection , vol.42 , pp. 489-500
    • Huet, C.1    Clairand, I.2    Trompier, F.3    Bey, E.4    Bottollier-Depois, J.-F.5
  • 4
    • 34548754423 scopus 로고    scopus 로고
    • EPR dosimetry for actual and suspected overexposures during radiotherapy treatments in Poland
    • Trompier, F. et al. EPR dosimetry for actual and suspected overexposures during radiotherapy treatments in Poland. Radiat. Meas. 42, 1025-1028 (2007).
    • (2007) Radiat. Meas. , vol.42 , pp. 1025-1028
    • Trompier, F.1
  • 5
    • 36048969410 scopus 로고    scopus 로고
    • Q-band EPR biodosimetry in tooth enamel microsamples: feasibility test and comparison with X-band
    • Romanyukha, A., Mitchell, C. A., Schauer, D. A., Romanyukha, L. and Swartz, H. M. Q-band EPR biodosimetry in tooth enamel microsamples: feasibility test and comparison with X-band. Health Phys. 93, 631-635 (2007).
    • (2007) Health Phys , vol.93 , pp. 631-635
    • Romanyukha, A.1    Mitchell, C.A.2    Schauer, D.A.3    Romanyukha, L.4    Swartz, H.M.5
  • 6
    • 0024818114 scopus 로고
    • Dose estimation by ESR spectroscopy at a fatal radiation accident
    • Regulla, D. F. and Deffner, U. Dose estimation by ESR spectroscopy at a fatal radiation accident. Appl. Radiat. Isot. 40, 1039-1043 (1989).
    • (1989) Appl. Radiat. Isot. , vol.40 , pp. 1039-1043
    • Regulla, D.F.1    Deffner, U.2
  • 7
    • 0021028173 scopus 로고
    • Dosimetry by ESR spectroscopy following a radiation accident
    • Sagstuen, E., Theisen, H. and Henriksen, T. Dosimetry by ESR spectroscopy following a radiation accident. Health Phys. 45, 961-968 (1983).
    • (1983) Health Phys , vol.45 , pp. 961-968
    • Sagstuen, E.1    Theisen, H.2    Henriksen, T.3
  • 9
    • 75649108201 scopus 로고    scopus 로고
    • An attempt to use sweeteners as a material for accident dosimetry
    • Kinoshita, A., José, A. F. and Baffa, O. An attempt to use sweeteners as a material for accident dosimetry. Health Phys. 98(2), 406-411 (2010).
    • (2010) Health Phys , vol.98 , Issue.2 , pp. 406-411
    • Kinoshita, A.1    José, A.F.2    Baffa, O.3
  • 10
    • 29144450910 scopus 로고    scopus 로고
    • ESR dosimetric properties of window glass. Beam interactions with materials and atoms
    • Engin, B., Aydas, C. and Demirtas, H. ESR dosimetric properties of window glass. Beam interactions with materials and atoms. Nucl. Instrum. Meth. Phys. Res. Section B 243, 149-155 (2006).
    • (2006) Nucl. Instrum. Meth. Phys. Res. Section B , vol.243 , pp. 149-155
    • Engin, B.1    Aydas, C.2    Demirtas, H.3
  • 11
    • 0029010958 scopus 로고
    • Dosimetric properties of watch glass: a potential practical ESR dosemeter for nuclear accidents
    • Wu, K., Sun, C. P. and Shi, Y. M. Dosimetric properties of watch glass: a potential practical ESR dosemeter for nuclear accidents. Radiat. Prot. Dosim. 59, 223-225 (1995).
    • (1995) Radiat. Prot. Dosim. , vol.59 , pp. 223-225
    • Wu, K.1    Sun, C.P.2    Shi, Y.M.3
  • 12
    • 75649143301 scopus 로고    scopus 로고
    • Radiation accident dosimetry on glass by TL and EPR spectrometry
    • Bassinet, C., Trompier, F. and Clairand, I. Radiation accident dosimetry on glass by TL and EPR spectrometry. Health Phys. 98(2), 400-405 (2010).
    • (2010) Health Phys , vol.98 , Issue.2 , pp. 400-405
    • Bassinet, C.1    Trompier, F.2    Clairand, I.3
  • 13
    • 0024804554 scopus 로고
    • Evaluation of ESR as a radiation accident dosimetry technique
    • Dalgarno, B. G. and McClymont, J. D. Evaluation of ESR as a radiation accident dosimetry technique. Appl. Radiat. Isot. 40, 1013-1020 (1989).
    • (1989) Appl. Radiat. Isot. , vol.40 , pp. 1013-1020
    • Dalgarno, B.G.1    McClymont, J.D.2
  • 14
    • 0023618888 scopus 로고
    • External dose to a Japanese tourist from the Chernobyl reactor accident
    • Nakajima, T. External dose to a Japanese tourist from the Chernobyl reactor accident. Health Phys. 34, 405-407 (1987).
    • (1987) Health Phys , vol.34 , pp. 405-407
    • Nakajima, T.1
  • 15
    • 75649111206 scopus 로고    scopus 로고
    • Radiation accident dosimetry on plastics by EPR spectrometry
    • Trompier, F., Bassinet, C. and Clairand, I. Radiation accident dosimetry on plastics by EPR spectrometry. Health Phys. 98(2), 388-394 (2010).
    • (2010) Health Phys , vol.98 , Issue.2 , pp. 388-394
    • Trompier, F.1    Bassinet, C.2    Clairand, I.3
  • 16
    • 0028860310 scopus 로고
    • Electron paramagnetic resonance spectra of irradiated fingernails: a possible measure of accidental exposure
    • Symons, M., Chandra, H. and Wyatt, J. L. Electron paramagnetic resonance spectra of irradiated fingernails: a possible measure of accidental exposure. Radiat. Prot. Dosim. 58, 11-15 (1995).
    • (1995) Radiat. Prot. Dosim. , vol.58 , pp. 11-15
    • Symons, M.1    Chandra, H.2    Wyatt, J.L.3
  • 19
    • 75649088134 scopus 로고    scopus 로고
    • Fingernail dosimetry: current status and perspectives
    • Romanuykha, A., Reyes, R., Trompier, F. and Benevides, L. Fingernail dosimetry: current status and perspectives. Health Phys. 98(2), 296-300 (2010).
    • (2010) Health Phys , vol.98 , Issue.2 , pp. 296-300
    • Romanuykha, A.1    Reyes, R.2    Trompier, F.3    Benevides, L.4
  • 20
    • 18244414634 scopus 로고    scopus 로고
    • Telephone chip-cards as individual dosemeters
    • Göksu, H. Y. Telephone chip-cards as individual dosemeters. Radiat. Meas. 37, 617-620 (2003).
    • (2003) Radiat. Meas. , vol.37 , pp. 617-620
    • Göksu, H.Y.1
  • 21
    • 75649141267 scopus 로고    scopus 로고
    • Radiation accident dosimetry on electronic components by OSL
    • Bassinet, C., Trompier, F. and Clairand, I. Radiation accident dosimetry on electronic components by OSL. Health Phys. 98(2), 440-445 (2010).
    • (2010) Health Phys , vol.98 , Issue.2 , pp. 440-445
    • Bassinet, C.1    Trompier, F.2    Clairand, I.3
  • 22
    • 45249095211 scopus 로고    scopus 로고
    • Pontuschka WM study of the gamma radiation response of watch glasses
    • Teixeira, M. I., Da Costa, Z. M. and Da Costa, C. R. Pontuschka WM study of the gamma radiation response of watch glasses. Radiat. Meas. 43, 480-482 (2008).
    • (2008) Radiat. Meas. , vol.43 , pp. 480-482
    • Teixeira, M.I.1    Da Costa, Z.M.2    Da Costa, C.R.3
  • 23
    • 0036387701 scopus 로고    scopus 로고
    • Commercial glass for high doses using different dosimetric techniques
    • Caldas, L. V. E. and Teixeira, M. I. Commercial glass for high doses using different dosimetric techniques. Radiat. Prot. Dosim. 101, 149-152 (2002).
    • (2002) Radiat. Prot. Dosim. , vol.101 , pp. 149-152
    • Caldas, L.V.E.1    Teixeira, M.I.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.