메뉴 건너뛰기




Volumn 44, Issue 1, 2009, Pages 6-10

Electron paramagnetic resonance radiation dosimetry in fingernails

Author keywords

Dosimetry; EPR; Fingernails

Indexed keywords

ACCIDENTS; DENTISTRY; DOSIMETERS; DOSIMETRY; ELECTRON RESONANCE; ELECTRON SPIN RESONANCE SPECTROSCOPY; ENAMELS; IONIZING RADIATION; MAGNETIC RESONANCE; PARAMAGNETIC MATERIALS; PARAMAGNETISM; QUANTUM THEORY; RADIATION; RADIATION SHIELDING; RADIOACTIVITY; RESONANCE; TOOTH ENAMEL;

EID: 60249101147     PISSN: 13504487     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radmeas.2008.10.005     Document Type: Article
Times cited : (52)

References (11)
  • 2
    • 33749683552 scopus 로고    scopus 로고
    • Ex vivo ESR measurements associated with Monte Carlo calculations for accident dosimetry: application to the 2001 Georgian accident
    • Clairand I., Trompier F., Bottollier-Depois J.-F., and Gourmelon P. Ex vivo ESR measurements associated with Monte Carlo calculations for accident dosimetry: application to the 2001 Georgian accident. Radiat. Prot. Dosimetry 120 (2006) 500-505
    • (2006) Radiat. Prot. Dosimetry , vol.120 , pp. 500-505
    • Clairand, I.1    Trompier, F.2    Bottollier-Depois, J.-F.3    Gourmelon, P.4
  • 3
    • 44949221146 scopus 로고    scopus 로고
    • Physical dosimetric reconstruction of a radiological accident due to gammagraphy equipment that occurred in Dakar and Abidjan in summer 2006. Radiat
    • Clairand I., Huet C., Trompier F., and Bottollier-Depois J.F. Physical dosimetric reconstruction of a radiological accident due to gammagraphy equipment that occurred in Dakar and Abidjan in summer 2006. Radiat. Meas. 43 2-6 (2008) 698-703
    • (2008) Meas. , vol.43 , Issue.2-6 , pp. 698-703
    • Clairand, I.1    Huet, C.2    Trompier, F.3    Bottollier-Depois, J.F.4
  • 4
    • 0024804554 scopus 로고
    • Evaluation of ESR as a radiation accident dosimetry technique
    • Dalgarno B.G., and Mcclymont J.D. Evaluation of ESR as a radiation accident dosimetry technique. Appl. Radiat. Isot. 40 (1989) 1013-1020
    • (1989) Appl. Radiat. Isot. , vol.40 , pp. 1013-1020
    • Dalgarno, B.G.1    Mcclymont, J.D.2
  • 5
    • 60249088132 scopus 로고    scopus 로고
    • Monte Carlo dose reconstruction in case of a radiological accident: application to the accident in Chile in December 2005
    • Huet C., Clairand I., Trompier F., Bey E., and Bottollier-Depois J.F. Monte Carlo dose reconstruction in case of a radiological accident: application to the accident in Chile in December 2005. Radioprotection 42 (2007) 489-500
    • (2007) Radioprotection , vol.42 , pp. 489-500
    • Huet, C.1    Clairand, I.2    Trompier, F.3    Bey, E.4    Bottollier-Depois, J.F.5
  • 6
    • 46549089292 scopus 로고    scopus 로고
    • Physical dosimetric reconstruction of a radiological accident at Fleurus (Belgium) on 11 March 2006
    • Huet C., Trompier F., Clairand I., Queinnec F., and Bottollier-Depois J.F. Physical dosimetric reconstruction of a radiological accident at Fleurus (Belgium) on 11 March 2006. Radiat. Meas. 43 2-6 (2008) 845-848
    • (2008) Radiat. Meas. , vol.43 , Issue.2-6 , pp. 845-848
    • Huet, C.1    Trompier, F.2    Clairand, I.3    Queinnec, F.4    Bottollier-Depois, J.F.5
  • 7
    • 0028860310 scopus 로고
    • Electron paramagnetic resonance spectra of irradiated fingernails: a possible measure of accidental exposure
    • Symons M., Chandra H., and Wyatt J.L. Electron paramagnetic resonance spectra of irradiated fingernails: a possible measure of accidental exposure. Radiat. Prot. Dosimetry 58 (1995) 11-15
    • (1995) Radiat. Prot. Dosimetry , vol.58 , pp. 11-15
    • Symons, M.1    Chandra, H.2    Wyatt, J.L.3
  • 10


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.