Volumn 98, Issue 2, 2010, Pages 400-405

Radiation accident dosimetry on glass by tl and epr spectrometry

Author keywords

Accident analysis; Dose assessment; Dosimetry; Exposure, radiation

Indexed keywords

GLASS;

EID: 75649143301     PISSN: 00179078     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.HP.0000346330.72296.51     Document Type: Article
Times cited : (65)

References (21)
  • 2
    • 75649141267 scopus 로고    scopus 로고
    • Radiation accident dosimetry on electronic components by OSL
    • Bassinet C, Trompier F, Clairand I. Radiation accident dosimetry on electronic components by OSL. Health Phys 98:440-445; 2010.
    • (2010) Health Phys , vol.98 , pp. 440-445
    • Bassinet, C.1    Trompier, F.2    Clairand, I.3
  • 3
    • 0036387701 scopus 로고    scopus 로고
    • Commercial glass for high doses using different dosimetric techniques
    • Caldas LVE, Teixeira MI. Commercial glass for high doses using different dosimetric techniques. Radiat Prot Dosim 101:149-152; 2002.
    • (2002) Radiat Prot Dosim , vol.101 , pp. 149-152
    • Caldas, L.V.E.1    Teixeira, M.I.2
  • 4
    • 33749683552 scopus 로고    scopus 로고
    • Ex vivo ESR measurements associated with Monte Carlo calculations for accident dosimetry: Application to the 2001 Georgian accident
    • Clairand I, Trompier F, Bottollier-Depois J-F, Gourmelon P. Ex vivo ESR measurements associated with Monte Carlo calculations for accident dosimetry: application to the 2001 Georgian accident. Radiat Prot Dosim 119:500-505; 2006.
    • (2006) Radiat Prot Dosim , vol.119 , pp. 500-505
    • Clairand, I.1    Trompier, F.2    Bottollier-Depois, J.-F.3    Gourmelon, P.4
  • 5
    • 44949221146 scopus 로고    scopus 로고
    • Physical dosimetric reconstruction of a radiological accident due to gammagraphy equipment that occured in Dakar and Abidjan in summer 2006
    • Clairand I, Huet C, Trompier F, Bottollier-Depois J-F. Physical dosimetric reconstruction of a radiological accident due to gammagraphy equipment that occured in Dakar and Abidjan in summer 2006. Radiat Meas 43:698-703; 2008.
    • (2008) Radiat Meas , vol.43 , pp. 698-703
    • Clairand, I.1    Huet, C.2    Trompier, F.3    Bottollier-Depois, J.-F.4
  • 6
    • 29144450910 scopus 로고    scopus 로고
    • ESR dosimetric properties of window glass. Beam interactions with materials and atoms
    • Engin B, Aydas C, Demirtas H. ESR dosimetric properties of window glass. Beam interactions with materials and atoms. Nucl Instruments Meth Phys Res Section B 243:149-155; 2006.
    • (2006) Nucl Instruments Meth Phys Res Section B , vol.243 , pp. 149-155
    • Engin, B.1    Aydas, C.2    Demirtas, H.3
  • 8
    • 18244414634 scopus 로고    scopus 로고
    • Telephone chip-cards as individual dosemeters
    • Göksu HY. Telephone chip-cards as individual dosemeters. Radiat Meas 37:617-620; 2003.
    • (2003) Radiat Meas , vol.37 , pp. 617-620
    • Göksu, H.Y.1
  • 9
    • 10644292511 scopus 로고    scopus 로고
    • ESR dosimetric properties of some biomineral materials
    • Hassan GM, Sharaf MA. ESR dosimetric properties of some biomineral materials. Appl Radiat Isot 62:375-381; 2005.
    • (2005) Appl Radiat Isot , vol.62 , pp. 375-381
    • Hassan, G.M.1    Sharaf, M.A.2
  • 10
    • 60249088132 scopus 로고    scopus 로고
    • Monte Carlo dose reconstruction in case of a radiological accident: Application to the accident in Chile in December 2005
    • Huet C, Clairand I, Trompier F, Bey E, Bottollier-Depois J-F. Monte Carlo dose reconstruction in case of a radiological accident: application to the accident in Chile in December 2005. Radioprotection 42:489-500; 2007.
    • (2007) Radioprotection , vol.42 , pp. 489-500
    • Huet, C.1    Clairand, I.2    Trompier, F.3    Bey, E.4    Bottollier-Depois, J.-F.5
  • 11
    • 46549089292 scopus 로고    scopus 로고
    • Physical dosimetric reconstruction of a radiological accident at Fleurus (Belgium) on 11 March
    • Huet C, Trompier F, Clairand I, Queinnec F, Bottollier-Depois JF. Physical dosimetric reconstruction of a radiological accident at Fleurus (Belgium) on 11 March 2006. Radiat Meas 43:845-848; 2008.
    • (2006) Radiat Meas , vol.43 , pp. 845-848
    • Huet, C.1    Trompier, F.2    Clairand, I.3    Queinnec, F.4    Bottollier-Depois, J.F.5
  • 12
    • 45249117719 scopus 로고    scopus 로고
    • Optically stimulated luminescence of electronic components for forensic, retrospective, and accident dosimetry
    • Inrig EL, Godfrey-Smith DI, Khanna S. Optically stimulated luminescence of electronic components for forensic, retrospective, and accident dosimetry. Radiat Meas 43:726-730; 2008.
    • (2008) Radiat Meas , vol.43 , pp. 726-730
    • Inrig, E.L.1    Godfrey-Smith, D.I.2    Khanna, S.3
  • 21
    • 0029010958 scopus 로고
    • Dosimetric properties of watch glass: A potential practical ESR dosemeter for nuclear accidents
    • Wu K, Sun CP, Shi YM. Dosimetric properties of watch glass: a potential practical ESR dosemeter for nuclear accidents. Radiat Prot Dosim 59:223-225; 1995.
    • (1995) Radiat Prot Dosim , vol.59 , pp. 223-225
    • Wu, K.1    Sun, C.P.2    Shi, Y.M.3