메뉴 건너뛰기




Volumn , Issue , 2011, Pages 877-880

High-throughput automated system for statistical biosensing employing microcantilever arrays

Author keywords

[No Author keywords available]

Indexed keywords

ANTIBODY ASSAYS; AUTOMATED SYSTEMS; BIOCHEMICAL REACTIONS; BIOSENSING; DYNAMIC MODES; HIGH-THROUGHPUT; MICRO-CANTILEVERS; MICROCANTILEVER ARRAYS; OPTICAL LEVER; RESONANCE FREQUENCIES;

EID: 79953770727     PISSN: 10846999     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/MEMSYS.2011.5734565     Document Type: Conference Paper
Times cited : (4)

References (6)
  • 1
    • 0037403562 scopus 로고    scopus 로고
    • Development of nanomechanical biosensors for detection of the pesticide DDT
    • DOI 10.1016/S0956-5663(03)00035-6
    • M. Álvarez, A. Calle, J. Tamayo, L.M. Lechuga, A. Abad, A. Montoya, "Development of nanomechanical biosensors for detection of the pesticide DDT", Biosens. Bioelectron., vol. 18, pp. 649-653, 2003. (Pubitemid 36428654)
    • (2003) Biosensors and Bioelectronics , vol.18 , Issue.5-6 , pp. 649-653
    • Alvarez, M.1    Calle, A.2    Tamayo, J.3    Lechuga, L.M.4    Abad, A.5    Montoya, A.6
  • 2
    • 62249113545 scopus 로고    scopus 로고
    • Quantitative time-resolved measurement of membrane protein-ligand interactions using microcantilever array sensors
    • T. Braun et al., "Quantitative time-resolved measurement of membrane protein-ligand interactions using microcantilever array sensors", Nat. Nanotechnol., vol. 4, pp. 179-185, 2009.
    • (2009) Nat. Nanotechnol. , vol.4 , pp. 179-185
    • Braun, T.1
  • 4
    • 0035888391 scopus 로고    scopus 로고
    • Micromechanical cantilever-based biosensors
    • DOI 10.1016/S0925-4005(01)00856-5, PII S0925400501008565
    • Raiteri, R., Grattarola, M., Butt, H. J., and P. Skládal, "Micromechanical cantilever-based biosensors", Sensor. Actuat. B-Chem., vol. 79, pp. 115-126, 2001. (Pubitemid 32866876)
    • (2001) Sensors and Actuators, B: Chemical , vol.79 , Issue.2-3 , pp. 115-126
    • Raiteri, R.1    Grattarola, M.2    Butt, H.-J.3    Skladal, P.4
  • 6
    • 76949083991 scopus 로고    scopus 로고
    • Self-aligned cantilever positioning for on-substrate measurement using DVD-ROM pickup head
    • F.G. Bosco, E.T. Hwu, S. Keller, A. Boisen, "Self-aligned cantilever positioning for on-substrate measurement using DVD-ROM pickup head", Microel. Engineering, vol. 87, pp. 708-711, 2010.
    • (2010) Microel. Engineering , vol.87 , pp. 708-711
    • Bosco, F.G.1    Hwu, E.T.2    Keller, S.3    Boisen, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.