메뉴 건너뛰기




Volumn 22, Issue 5, 2011, Pages 567-570

Primary stability, insertion torque and bone density of cylindric implant ad modum Branemark: Is there a relationship? An in vitro study

Author keywords

Bone density; Dental implants; Insertion torque; Micromotion; Primary stability

Indexed keywords

ANIMAL; ARTICLE; BIOMECHANICS; BONE DENSITY; CATTLE; COMPARATIVE STUDY; DENTAL CARE; INSTRUMENTATION; MATERIALS TESTING; MECHANICAL STRESS; METHODOLOGY; MOTION; PHYSIOLOGY; TOOTH IMPLANTATION; TOOTH PROSTHESIS; TORQUE;

EID: 79953683690     PISSN: 09057161     EISSN: 16000501     Source Type: Journal    
DOI: 10.1111/j.1600-0501.2010.02036.x     Document Type: Article
Times cited : (65)

References (26)
  • 1
    • 0027613970 scopus 로고
    • Interface histology of unloaded and early loaded partially stabilized zirconia endosseous implant in initial bone healing
    • Akagawa, Y., Ichikawa, Y., Nikai, H. & Tsuru, H. (1993) Interface histology of unloaded and early loaded partially stabilized zirconia endosseous implant in initial bone healing. Journal of Prosthetic Dentistry 69: 599-604.
    • (1993) Journal of Prosthetic Dentistry , vol.69 , pp. 599-604
    • Akagawa, Y.1    Ichikawa, Y.2    Nikai, H.3    Tsuru, H.4
  • 2
    • 0027023659 scopus 로고
    • Issues in bone mechanics related to oral implants
    • Bidez, M.W. & Misch, C.E. (1992) Issues in bone mechanics related to oral implants. Implant Dentistry 1: 289-294.
    • (1992) Implant Dentistry , vol.1 , pp. 289-294
    • Bidez, M.W.1    Misch, C.E.2
  • 3
    • 0033140443 scopus 로고    scopus 로고
    • In vivo bone response to biomechanical loading at the bone/dental-implant interface
    • Brunski, J.B. (1999) In vivo bone response to biomechanical loading at the bone/dental-implant interface. Advances in Dental Research 13: 99-119.
    • (1999) Advances in Dental Research , vol.13 , pp. 99-119
    • Brunski, J.B.1
  • 4
    • 0031061750 scopus 로고    scopus 로고
    • Implant-retained mandibular overdentures with immediate loading. A retrospective multicenter study on 226 consecutive cases
    • Chiapasco, M., Gatti, C., Rossi, E., Haefliger, W. & Markwalder, T.H. (1997) Implant-retained mandibular overdentures with immediate loading. A retrospective multicenter study on 226 consecutive cases. Clinical Oral Implants Research 8: 48-57.
    • (1997) Clinical Oral Implants Research , vol.8 , pp. 48-57
    • Chiapasco, M.1    Gatti, C.2    Rossi, E.3    Haefliger, W.4    Markwalder, T.H.5
  • 5
    • 0033209666 scopus 로고    scopus 로고
    • Clinical and radiographic evaluation of early loaded free-standing dental implants with various coatings in beagle dogs
    • Corso, M., Sirota, C., Fiorellini, J., Rasool, F., Szmukler-Moncler, S. & Weber, H.P. (1999) Clinical and radiographic evaluation of early loaded free-standing dental implants with various coatings in beagle dogs. Journal of Prosthetic Dentistry 82: 428-435.
    • (1999) Journal of Prosthetic Dentistry , vol.82 , pp. 428-435
    • Corso, M.1    Sirota, C.2    Fiorellini, J.3    Rasool, F.4    Szmukler-Moncler, S.5    Weber, H.P.6
  • 7
    • 2342577562 scopus 로고    scopus 로고
    • In vitro evaluation of horizontal implant micromovement in bone specimen with contact endoscopy
    • Engelke, W., Decco, O.A., Rau, M.J., Massoni, M.C. & Schwarzwaller, W. (2004) In vitro evaluation of horizontal implant micromovement in bone specimen with contact endoscopy. Implant Dentistry 13: 88-94.
    • (2004) Implant Dentistry , vol.13 , pp. 88-94
    • Engelke, W.1    Decco, O.A.2    Rau, M.J.3    Massoni, M.C.4    Schwarzwaller, W.5
  • 8
    • 0347667233 scopus 로고
    • Occlusal forces during function
    • In: Rowlands, C.C., ed., Ann Arbor: University of Michigan.
    • Graf, H. (1975) Occlusal forces during function. In: Rowlands, C.C., ed. Occlusion: Research on Form and Function, 90-110. Ann Arbor: University of Michigan.
    • (1975) Occlusion: Research on Form and Function , pp. 90-110
    • Graf, H.1
  • 9
    • 0023760823 scopus 로고
    • Single crystal sapphire endosseous dental implant loaded with functional stress-clinical and histological evaluation of peri-implant tissues
    • Hashimoto, M., Akagawa, Y., Hashimoto, H., Nikai, H. & Tsuru, H. (1988) Single crystal sapphire endosseous dental implant loaded with functional stress-clinical and histological evaluation of peri-implant tissues. Journal of Oral Rehabilitation 15: 65-76.
    • (1988) Journal of Oral Rehabilitation , vol.15 , pp. 65-76
    • Hashimoto, M.1    Akagawa, Y.2    Hashimoto, H.3    Nikai, H.4    Tsuru, H.5
  • 11
    • 4644291445 scopus 로고    scopus 로고
    • Biomechanical aspects of marginal bone resorption around osseointegrated implants
    • considerations based on a three-dimensional finite element analysis.
    • Kitamura, E., Stegaroiu, R., Nomura, S. & Miyakawa, O. (2004) Biomechanical aspects of marginal bone resorption around osseointegrated implants: considerations based on a three-dimensional finite element analysis. Clinical Oral Implants Research 15: 401-412.
    • (2004) Clinical Oral Implants Research , vol.15 , pp. 401-412
    • Kitamura, E.1    Stegaroiu, R.2    Nomura, S.3    Miyakawa, O.4
  • 12
    • 0026266915 scopus 로고
    • Histologic evaluation of hydroxylapatite-coated versus uncoated titanium blade implants in delayed and immediately loaded applications
    • Lum, L.B., Beirne, O.R. & Curtis, D.A. (1991) Histologic evaluation of hydroxylapatite-coated versus uncoated titanium blade implants in delayed and immediately loaded applications. The International Journal of Oral & Maxillofacial Implants 6: 456-462.
    • (1991) The International Journal of Oral & Maxillofacial Implants , vol.6 , pp. 456-462
    • Lum, L.B.1    Beirne, O.R.2    Curtis, D.A.3
  • 13
    • 0034574211 scopus 로고    scopus 로고
    • Measurements comparing the initial stability of five designs of dental implants
    • a human cadaver study.
    • O'Sullivan, D., Sennerby, L. & Meredith, N. (2000) Measurements comparing the initial stability of five designs of dental implants: a human cadaver study. Clinical Implant Dentistry & Related Research 2: 85-92.
    • (2000) Clinical Implant Dentistry & Related Research , vol.2 , pp. 85-92
    • O'Sullivan, D.1    Sennerby, L.2    Meredith, N.3
  • 15
    • 0036854433 scopus 로고    scopus 로고
    • Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation
    • choosing a new balance between stability and biology.
    • Perren, S.M. (2002) Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. Journal of Bone and Joint Surgery - British Volume 84: 1093-1110.
    • (2002) Journal of Bone and Joint Surgery - British Volume , vol.84 , pp. 1093-1110
    • Perren, S.M.1
  • 17
    • 24344488119 scopus 로고    scopus 로고
    • Bone healing
    • histologic and physiologic concepts. In: Summer-Smith, G., ed., Stuttgart, New York: Thieme.
    • Rahn, B. (2002) Bone healing: histologic and physiologic concepts. In: Summer-Smith, G., ed. Bone in Clinical Orthopedics, 287-326. Stuttgart, New York: Thieme.
    • (2002) Bone in Clinical Orthopedics , pp. 287-326
    • Rahn, B.1
  • 19
    • 0026521288 scopus 로고
    • Hydroxyapatite coating modifies implant membrane formation. Controlled micromotion studied in dogs
    • Soballe, K., Brockstedt-Rasmussen, H., Hansen, E.S. & Bunger, C. (1992) Hydroxyapatite coating modifies implant membrane formation. Controlled micromotion studied in dogs. Acta Orthopaedica Scandinavica 63: 128-140.
    • (1992) Acta Orthopaedica Scandinavica , vol.63 , pp. 128-140
    • Soballe, K.1    Brockstedt-Rasmussen, H.2    Hansen, E.S.3    Bunger, C.4
  • 21
    • 0034139407 scopus 로고    scopus 로고
    • Considerations preliminary to the application of early and immediate loading protocols in dental implantology
    • Szmukler-Moncler, S., Piattelli, A., Favero, G.A. & Dubruille, J.H. (2000) Considerations preliminary to the application of early and immediate loading protocols in dental implantology. Clinical Oral Implants Research 11: 12-25.
    • (2000) Clinical Oral Implants Research , vol.11 , pp. 12-25
    • Szmukler-Moncler, S.1    Piattelli, A.2    Favero, G.A.3    Dubruille, J.H.4
  • 23
    • 0031136510 scopus 로고    scopus 로고
    • Immediate loading of threaded implants at stage 1 surgery in edentulous arches
    • ten consecutive case reports with 1- to 5-year data.
    • Tarnow, D.P., Emtiaz, S. & Classi, A. (1997) Immediate loading of threaded implants at stage 1 surgery in edentulous arches: ten consecutive case reports with 1- to 5-year data. The International Journal of Oral & Maxillofacial Implants 12: 319-324.
    • (1997) The International Journal of Oral & Maxillofacial Implants , vol.12 , pp. 319-324
    • Tarnow, D.P.1    Emtiaz, S.2    Classi, A.3
  • 24
    • 0033073260 scopus 로고    scopus 로고
    • Bone classification
    • clinical-histomorphometric comparison.
    • Trisi, P. & Rao, W. (1999) Bone classification: clinical-histomorphometric comparison. Clinical Oral Implants Research 10: 1-7.
    • (1999) Clinical Oral Implants Research , vol.10 , pp. 1-7
    • Trisi, P.1    Rao, W.2
  • 26
    • 0026298340 scopus 로고
    • Three-dimensional analyses of human bite-force magnitude and moment
    • Van Eijden, T.M. (1991) Three-dimensional analyses of human bite-force magnitude and moment. Archives of Oral Biology 36: 535-539.
    • (1991) Archives of Oral Biology , vol.36 , pp. 535-539
    • Van Eijden, T.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.