메뉴 건너뛰기




Volumn 22, Issue 4, 2011, Pages 1103-1113

Low-frequency axial ultrasound velocity correlates with bone mineral density and cortical thickness in the radius and tibia in pre- and postmenopausal women

Author keywords

Axial transmission; Bone mineral density; Cortical bone; Cortical thickness; First arriving signal; Guided waves; Ultrasound

Indexed keywords

ADULT; AGED; ARTICLE; BONE DENSITY; COMPUTER ASSISTED TOMOGRAPHY; CORRELATION ANALYSIS; CORTICAL BONE; CROSS-SECTIONAL STUDY; EXCITATION; FEMALE; HUMAN; MAJOR CLINICAL STUDY; POSTMENOPAUSE; PREMENOPAUSE; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; RADIUS; SENSITIVITY ANALYSIS; SOUND INTENSITY; THICKNESS; TIBIA; ULTRASOUND;

EID: 79953307662     PISSN: 0937941X     EISSN: 14332965     Source Type: Journal    
DOI: 10.1007/s00198-010-1273-7     Document Type: Article
Times cited : (41)

References (47)
  • 1
    • 0007980412 scopus 로고    scopus 로고
    • A new method for quantitative ultrasound measurements at multiple skeletal sites: First results of precision and fracture discrimination
    • R Barkmann E Kantorovich C Singal D Hans HK Genant M Heller CC Gluer 2000 A new method for quantitative ultrasound measurements at multiple skeletal sites: first results of precision and fracture discrimination J Clin Densitom 3 1 1 7 10745297 1:STN:280:DC%2BD3c3htFyksA%3D%3D (Pubitemid 30243308)
    • (2000) Journal of Clinical Densitometry , vol.3 , Issue.1 , pp. 1-7
    • Barkmann, R.1    Kantorovich, E.2    Singal, C.3    Hans, D.4    Genant, H.K.5    Heller, M.6    Gluer, C.-C.7
  • 2
    • 0030934837 scopus 로고    scopus 로고
    • Broadband ultrasound attenuation predicts fractures strongly and independently of densitometry in older women: A prospective study
    • DC Bauer CC Glüer JA Cauley TM Vogt KE Ensrud HK Genant DM Black 1997 Broadband ultrasound attenuation predicts fractures strongly and independently of densitometry in older women. A prospective study. Study of Osteoporotic Fractures Research Group Arch Intern Med 157 6 629 634 9080917 1:STN:280:DyaK2s3jsF2qug%3D%3D (Pubitemid 27133193)
    • (1997) Archives of Internal Medicine , vol.157 , Issue.6 , pp. 629-634
    • Bauer, D.C.1    Gluer, C.C.2    Cauley, J.A.3    Vogt, T.M.4    Ensrud, K.E.5    Genant, H.K.6    Black, D.M.7
  • 3
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • PII S0140673686908378
    • JM Bland DG Altman 1986 Statistical methods for assessing agreement between two methods of clinical measurement Lancet 1 307 310 2868172 1:STN:280:DyaL287hslWqsQ%3D%3D (Pubitemid 16134762)
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 4
    • 0036301829 scopus 로고    scopus 로고
    • Effect of bone cortical thickness on velocity measurements using ultrasonic axial transmission: A 2D simulation study
    • DOI 10.1121/1.1480836
    • E Bossy M Talmant P Laugier 2002 Effect of bone cortical thickness on velocity measurements using ultrasonic axial transmission: a 2D simulation study J Acoust Soc Am 112 1 297 307 12141355 (Pubitemid 34752175)
    • (2002) Journal of the Acoustical Society of America , vol.112 , Issue.1 , pp. 297-307
    • Bossy, E.1    Talmant, M.2    Laugier, P.3
  • 5
    • 2142716028 scopus 로고    scopus 로고
    • Three-dimensional simulations of ultrasonic axial transmission velocity measurement on cortical bone models
    • DOI 10.1121/1.1689960
    • E Bossy M Talmant P Laugier 2004 Three-dimensional simulations of ultrasonic axial transmission velocity measurement on cortical bone models J Acoust Soc Am 115 5 Pt 1 2314 2324 15139643 (Pubitemid 38542146)
    • (2004) Journal of the Acoustical Society of America , vol.115 , Issue.I5 , pp. 2314-2324
    • Bossy, E.1    Talmant, M.2    Laugier, P.3
  • 6
    • 1342324684 scopus 로고    scopus 로고
    • Bidirectional axial transmission can improve accuracy and precision of ultrasonic velocity measurement in cortical bone: A validation on test materials
    • 14995018
    • E Bossy M Talmant M Defontaine F Patat P Laugier 2004 Bidirectional axial transmission can improve accuracy and precision of ultrasonic velocity measurement in cortical bone: a validation on test materials IEEE Trans Ultrason Ferroelectr Freq Control 51 1 71 79 14995018
    • (2004) IEEE Trans Ultrason Ferroelectr Freq Control , vol.51 , Issue.1 , pp. 71-79
    • Bossy, E.1    Talmant, M.2    Defontaine, M.3    Patat, F.4    Laugier, P.5
  • 7
    • 16644388626 scopus 로고    scopus 로고
    • An in vitro study of the ultrasonic axial transmission technique at the radius: 1-MHz velocity measurements are sensitive to both mineralization and intracortical porosity
    • DOI 10.1359/JBMR.040513
    • E Bossy M Talmant F Peyrin L Akrout P Cloetens P Laugier 2004 An in vitro study of the ultrasonic axial transmission technique at the radius: 1-MHz velocity measurements are sensitive to both mineralization and intracortical porosity J Bone Miner Res 19 9 1548 1556 15312257 (Pubitemid 41094358)
    • (2004) Journal of Bone and Mineral Research , vol.19 , Issue.9 , pp. 1548-1556
    • Bossy, E.1    Talmant, M.2    Peyrin, F.3    Akrout, L.4    Cloetens, P.5    Laugier, P.6
  • 8
    • 0033664619 scopus 로고    scopus 로고
    • Analysis of the axial transmission technique for the assessment of skeletal status
    • 11144598 1:STN:280:DC%2BD3M7it12rug%3D%3D
    • E Camus M Talmant G Berger P Laugier 2000 Analysis of the axial transmission technique for the assessment of skeletal status J Acoust Soc Am 108 6 3058 3065 11144598 1:STN:280:DC%2BD3M7it12rug%3D%3D
    • (2000) J Acoust Soc Am , vol.108 , Issue.6 , pp. 3058-3065
    • Camus, E.1    Talmant, M.2    Berger, G.3    Laugier, P.4
  • 9
    • 0028886520 scopus 로고
    • Quantitative ultrasound of the tibia: A novel approach for assessment of bone status
    • 8573409 1:STN:280:DyaK287itVCktg%3D%3D
    • AJ Foldes A Rimon DD Keinan MM Popovtzer 1995 Quantitative ultrasound of the tibia: a novel approach for assessment of bone status Bone 17 4 363 367 8573409 1:STN:280:DyaK287itVCktg%3D%3D
    • (1995) Bone , vol.17 , Issue.4 , pp. 363-367
    • Foldes, A.J.1    Rimon, A.2    Keinan, D.D.3    Popovtzer, M.M.4
  • 10
    • 47849090931 scopus 로고    scopus 로고
    • A new quality of bone ultrasound research
    • 18986942 1:STN:280:DC%2BD1cjitVOhsw%3D%3D
    • CC Gluer 2008 A new quality of bone ultrasound research IEEE Trans Ultrason Ferroelectr Freq Control 55 7 1524 1528 18986942 1:STN:280: DC%2BD1cjitVOhsw%3D%3D
    • (2008) IEEE Trans Ultrason Ferroelectr Freq Control , vol.55 , Issue.7 , pp. 1524-1528
    • Gluer, C.C.1
  • 12
    • 67649090655 scopus 로고    scopus 로고
    • Influence of a gradient of material properties on ultrasonic wave propagation in cortical bone: Application to axial transmission
    • 19507985
    • G Haïat S Naili Q Grimal M Talmant C Desceliers C Soize 2009 Influence of a gradient of material properties on ultrasonic wave propagation in cortical bone: application to axial transmission J Acoust Soc Am 125 6 4043 4052 19507985
    • (2009) J Acoust Soc Am , vol.125 , Issue.6 , pp. 4043-4052
    • Haïat, G.1    Naili, S.2    Grimal, Q.3    Talmant, M.4    Desceliers, C.5    Soize, C.6
  • 15
    • 0036150530 scopus 로고    scopus 로고
    • Discriminatory ability of quantitative ultrasound parameters and bone mineral density in a population-based sample of postmenopausal women with vertebral fractures: Results of the Basel osteoporosis study
    • F Hartl A Tyndall M Kraenzlin C Bachmeier C Gückel U Senn D Hans R Theiler 2002 Discriminatory ability of quantitative ultrasound parameters and bone mineral density in a population-based sample of postmenopausal women with vertebral fractures: results of the Basel Osteoporosis Study J Bone Miner Res 17 2 321 330 11811563 1:STN:280:DC%2BD38%2FosFSnug%3D%3D (Pubitemid 34087665)
    • (2002) Journal of Bone and Mineral Research , vol.17 , Issue.2 , pp. 321-330
    • Hartl, F.C.1    Tyndall, A.2    Kraenzlin, M.3    Bachmeier, C.4    Guckel, C.5    Senn, U.6    Hans, D.7    Theiler, R.8
  • 16
    • 61549133885 scopus 로고    scopus 로고
    • Prospective evaluation of risk of vertebral fractures using quantitative ultrasound measurements and bone mineral density in a population-based sample of postmenopausal women: Results of the Basel Osteoporosis Study
    • 18417517 1:STN:280:DC%2BD1M7js1Oksw%3D%3D
    • R Hollaender F Hartl M-A Krieg A Tyndall C Geuckel C Buitrago-Tellez M Manghani M Kraenzlin R Theiler D Hans 2009 Prospective evaluation of risk of vertebral fractures using quantitative ultrasound measurements and bone mineral density in a population-based sample of postmenopausal women: results of the Basel Osteoporosis Study Ann Rheum Dis 68 391 396 18417517 1:STN:280: DC%2BD1M7js1Oksw%3D%3D
    • (2009) Ann Rheum Dis , vol.68 , pp. 391-396
    • Hollaender, R.1    Hartl, F.2    Krieg, M.-A.3    Tyndall, A.4    Geuckel, C.5    Buitrago-Tellez, C.6    Manghani, M.7    Kraenzlin, M.8    Theiler, R.9    Hans, D.10
  • 17
    • 0031717927 scopus 로고    scopus 로고
    • Prediction of fracture risk by radiographic absorptiometry and quantitative ultrasound: A prospective study
    • DOI 10.1007/s002239900544
    • C Huang PD Ross AJ Yates RE Walker K Imose K Emi RD Wasnich 1998 Prediction of fracture risk by radiographic absorptiometry and quantitative ultrasound: a prospective study Calcif Tissue Int 63 5 380 384 9799821 1:CAS:528:DyaK1cXntV2ltr4%3D (Pubitemid 28476326)
    • (1998) Calcified Tissue International , vol.63 , Issue.5 , pp. 380-384
    • Huang, C.1    Ross, P.D.2    Yates, A.J.3    Walker, R.E.4    Imose, K.5    Emi, K.6    Wasnich, R.D.7
  • 18
    • 2442495096 scopus 로고    scopus 로고
    • Can the WHO definition of osteoporosis be applied to multi-site axial transmission quantitative ultrasound?
    • DOI 10.1007/s00198-003-1555-4
    • KM Knapp GM Blake TD Spector I Fogelman 2004 Can the WHO definition of osteoporosis be applied to multi-site axial transmission quantitative ultrasound? Osteoporos Int 15 5 367 374 14685652 1:STN:280: DC%2BD2c3gsFKhtg%3D%3D (Pubitemid 38639331)
    • (2004) Osteoporosis International , vol.15 , Issue.5 , pp. 367-374
    • Knapp, K.M.1    Blake, G.M.2    Spector, T.D.3    Fogelman, I.4
  • 19
    • 0030804819 scopus 로고    scopus 로고
    • Tibial ultrasound velocity measured in situ predicts the material properties of tibial cortical bone
    • DOI 10.1016/S8756-3282(97)00076-8, PII S8756328297000768
    • SC Lee BS Coan ML Bouxsein 1997 Tibial ultrasound velocity measured in situ predicts the material properties of tibial cortical bone Bone 21 1 119 125 9213018 1:STN:280:DyaK2szls1GrsA%3D%3D (Pubitemid 27341749)
    • (1997) Bone , vol.21 , Issue.1 , pp. 119-125
    • Lee, S.C.1    Coan, B.S.2    Bouxsein, M.L.3
  • 20
    • 0031994949 scopus 로고    scopus 로고
    • Ultrasound velocity measurement in long bones: Measurement method and simulation of ultrasound wave propagation
    • G Lowet G Van der Perre 1998 Ultrasound velocity measurement in long bones: measurement method and simulation of ultrasound wave propagation Ultrasonics 36 147 154
    • (1998) Ultrasonics , vol.36 , pp. 147-154
    • Lowet, G.1    Van Der Perre, G.2
  • 22
    • 2642530630 scopus 로고    scopus 로고
    • Assessment of the tibia using ultrasonic guided waves in pubertal girls
    • DOI 10.1007/s00198-003-1528-7
    • P Moilanen PH Nicholson T Kärkkäinen Q Wang J Timonen S Cheng 2003 Assessment of the tibia using ultrasonic guided waves in pubertal girls Osteoporos Int 14 12 1020 1027 14564455 1:STN:280:DC%2BD3srpsFahsw%3D%3D (Pubitemid 40824274)
    • (2003) Osteoporosis International , vol.14 , Issue.12 , pp. 1020-1027
    • Moilanen, P.1    Nicholson, P.H.F.2    Karkkainen, T.3    Wang, Q.4    Timonen, J.5    Cheng, S.6
  • 23
    • 10044240615 scopus 로고    scopus 로고
    • Thickness sensitivity of ultrasound velocity in long bone phantoms
    • DOI 10.1016/j.ultrasmedbio.2004.08.017, PII S0301562904002157
    • P Moilanen V Kilappa PH Nicholson J Timonen S Cheng 2004 Thickness sensitivity of ultrasound velocity in long bone phantoms Ultrasound Med Biol 30 11 1517 1521 15588962 (Pubitemid 39601113)
    • (2004) Ultrasound in Medicine and Biology , vol.30 , Issue.11 , pp. 1517-1521
    • Moilanen, P.1    Kilappa, V.2    Nicholson, P.H.F.3    Timonen, J.4    Cheng, S.5
  • 24
    • 33846935789 scopus 로고    scopus 로고
    • Assessment of the cortical bone thickness using ultrasonic guided waves: Modelling and in vitro study
    • DOI 10.1016/j.ultrasmedbio.2006.07.038, PII S0301562906017807
    • P Moilanen PH Nicholson V Kilappa S Cheng J Timonen 2007 Assessment of the cortical bone thickness using ultrasonic guided waves: modeling and in vitro study Ultrasound Med Biol 33 2 254 262 17306696 (Pubitemid 46240596)
    • (2007) Ultrasound in Medicine and Biology , vol.33 , Issue.2 , pp. 254-262
    • Moilanen, P.1    Nicholson, P.H.F.2    Kilappa, V.3    Cheng, S.4    Timonen, J.5
  • 26
    • 47749144295 scopus 로고    scopus 로고
    • Prediction of bone mechanical properties using QUS and pQCT: Study of the human distal radius
    • DOI 10.1016/j.medengphy.2007.08.006, PII S1350453307001579
    • M Muller D Mitton P Moilanen V Bousson M Talmant P Laugier 2008 Prediction of bone mechanical properties using QUS and pQCT: Study of the human distal radius Med Eng Phys 30 6 761 767 17988924 1:STN:280: DC%2BD1cvnsFyjtA%3D%3D (Pubitemid 352024422)
    • (2008) Medical Engineering and Physics , vol.30 , Issue.6 , pp. 761-767
    • Muller, M.1    Mitton, D.2    Moilanen, P.3    Bousson, V.4    Talmant, M.5    Laugier, P.6
  • 27
    • 67349124360 scopus 로고    scopus 로고
    • Correlation of tibial low-frequency ultrasound velocity with femoral radiographic measurements and BMD in elderly women
    • 19216022
    • M Määttä P Moilanen P Nicholson S Cheng J Timonen T Jämsä 2009 Correlation of tibial low-frequency ultrasound velocity with femoral radiographic measurements and BMD in elderly women Ultrasound Med Biol 35 6 903 911 19216022
    • (2009) Ultrasound Med Biol , vol.35 , Issue.6 , pp. 903-911
    • Määttä, M.1    Moilanen, P.2    Nicholson, P.3    Cheng, S.4    Timonen, J.5    Jämsä, T.6
  • 28
    • 11244269456 scopus 로고    scopus 로고
    • Bone mineral density-independent association of quantitative ultrasound measurements and fracture risk in women
    • DOI 10.1007/s00198-004-1717-z
    • TV Nguyen JR Center JA Eisman 2004 Bone mineral density-independent association of quantitative ultrasound measurements and fracture risk in women Osteoporos Int 15 12 942 947 15309384 (Pubitemid 40064647)
    • (2004) Osteoporosis International , vol.15 , Issue.12 , pp. 942-947
    • Nguyen, T.V.1    Center, J.R.2    Eisman, J.A.3
  • 29
    • 1842858991 scopus 로고    scopus 로고
    • Guided ultrasonic waves in long bones: Modelling, experiment and in vivo application
    • DOI 10.1088/0967-3334/23/4/313, PII S0967333402372083
    • PHF Nicholson P Moilanen T Kärkkäinen J Timonen S Cheng 2002 Guided ultrasonic waves in long bones: modelling, experiment and in vivo application Physiol Meas 23 755 768 12450274 (Pubitemid 35386580)
    • (2002) Physiological Measurement , vol.23 , Issue.4 , pp. 755-768
    • Nicholson, P.H.F.1    Moilanen, P.2    Karkkainen, T.3    Timonen, J.4    Cheng, S.5
  • 30
    • 47849104505 scopus 로고    scopus 로고
    • Ultrasound and the biomechanical competence of bone
    • 18986944 1:STN:280:DC%2BD1cjitVOhsQ%3D%3D
    • PHF Nicholson 2008 Ultrasound and the biomechanical competence of bone IEEE Trans Ultrason Ferroelectr Freq Control 55 7 1539 1545 18986944 1:STN:280:DC%2BD1cjitVOhsQ%3D%3D
    • (2008) IEEE Trans Ultrason Ferroelectr Freq Control , vol.55 , Issue.7 , pp. 1539-1545
    • Nicholson, P.H.F.1
  • 31
    • 0033382521 scopus 로고    scopus 로고
    • An in vitro investigation of the dependence on sample thickness of the speed of sound along the specimen
    • DOI 10.1016/S1350-4533(99)00090-9, PII S1350453399000909
    • CF Njeh D Hans C Wu E Kantorovich M Sister T Fuerst HK Genant 1999 An in vitro investigation of the dependence on sample thickness of the speed of sound along the specimen Med Eng Phys 21 9 651 659 10699567 1:STN:280: DC%2BD3c7msFansA%3D%3D (Pubitemid 30103666)
    • (1999) Medical Engineering and Physics , vol.21 , Issue.9 , pp. 651-659
    • Njeh, C.F.1    Hans, D.2    Wu, C.3    Kantorovich, E.4    Sister, M.5    Fuerst, T.6    Genant, H.K.7
  • 35
    • 24944552841 scopus 로고    scopus 로고
    • Bone microstructure and elastic tissue properties are reflected in QUS axial transmission measurements
    • DOI 10.1016/j.ultrasmedbio.2005.05.002, PII S030156290500222X
    • K Raum I Leguerney F Chandelier E Bossy M Talmant A Saied F Peyrin P Laugier 2005 Bone microstructure and elastic tissue properties are reflected in QUS axial transmission measurements Ultrasound Med Biol 31 9 1225 1235 16176789 (Pubitemid 41318856)
    • (2005) Ultrasound in Medicine and Biology , vol.31 , Issue.9 , pp. 1225-1235
    • Raum, K.1    Leguerney, I.2    Chandelier, F.3    Bossy, E.4    Talmant, M.5    Saied, A.6    Peyrin, F.7    Laugier, P.8
  • 36
    • 31344479330 scopus 로고    scopus 로고
    • Derivation of elastic stiffness from site-matched mineral density and acoustic impedance maps
    • DOI 10.1088/0031-9155/51/3/018, PII S0031915506023669
    • K Raum RO Cleveland F Peyrin P Laugier 2006 Derivation of elastic stiffness from site-matched mineral density and acoustic impedance maps Phys Med Biol 51 3 747 758 16424593 (Pubitemid 43139116)
    • (2006) Physics in Medicine and Biology , vol.51 , Issue.3 , pp. 747-758
    • Raum, K.1    Cleveland, R.O.2    Peyrin, F.3    Laugier, P.4
  • 37
    • 0034963825 scopus 로고    scopus 로고
    • Ultrasound velocity and cortical bone characteristics in vivo
    • DOI 10.1007/s001980170109
    • H Sievänen S Cheng S Ollikainen K Uusi-Rasi 2001 Ultrasound velocity and cortical bone characteristics in vivo Osteoporos Int 12 5 399 405 11444089 (Pubitemid 32606465)
    • (2001) Osteoporosis International , vol.12 , Issue.5 , pp. 399-405
    • Sievanen, H.1    Cheng, S.2    Ollikainen, S.3    Uusi-Rasi, K.4
  • 38
    • 0003633894 scopus 로고
    • 6 The Iowa State University Press Ames, Iowa, USA
    • Snedecor GW (1976) Statistical methods, 6th edn. The Iowa State University Press, Ames, Iowa, USA
    • (1976) Statistical Methods
    • Snedecor, G.W.1
  • 39
    • 0029083739 scopus 로고
    • Cortical ultrasound velocity as an indicator of bone status
    • 8800785 1:STN:280:DyaK287gvFynsg%3D%3D
    • M Stegman R Heaney D Travers-Gustafson J Leist 1995 Cortical ultrasound velocity as an indicator of bone status Osteoporos Int 5 349 353 8800785 1:STN:280:DyaK287gvFynsg%3D%3D
    • (1995) Osteoporos Int , vol.5 , pp. 349-353
    • Stegman, M.1    Heaney, R.2    Travers-Gustafson, D.3    Leist, J.4
  • 40
    • 62849105585 scopus 로고    scopus 로고
    • Measurement of the dispersion and attenuation of cylindrical ultrasonic guided waves in long bone
    • 19153000
    • D Ta W Wang Y Wang LH Le Y Zhou 2009 Measurement of the dispersion and attenuation of cylindrical ultrasonic guided waves in long bone Ultrasound Med Biol 35 4 641 652 19153000
    • (2009) Ultrasound Med Biol , vol.35 , Issue.4 , pp. 641-652
    • Ta, D.1    Wang, W.2    Wang, Y.3    Le, L.H.4    Zhou, Y.5
  • 42
    • 20844453036 scopus 로고    scopus 로고
    • Use of multiple acoustic wave modes for assessment of long bones: Model study
    • DOI 10.1016/j.ultras.2005.03.004, PII S0041624X05000119
    • A Tatarinov N Sarvazyan A Sarvazyan 2005 Use of multiple acoustic wave modes for assessment of long bones: model study Ultrasonics 43 8 672 680 15982472 (Pubitemid 40858041)
    • (2005) Ultrasonics , vol.43 , Issue.8 , pp. 672-680
    • Tatarinov, A.1    Sarvazyan, N.2    Sarvazyan, A.3
  • 44
    • 0033785825 scopus 로고    scopus 로고
    • Reference database for bone speed of sound measurement by a novel quantitative multi-site ultrasound device
    • 11095172 1:STN:280:DC%2BD3M%2FlsFartg%3D%3D
    • M Weiss AB Ben-Shlomo P Hagag M Rapoport 2000 Reference database for bone speed of sound measurement by a novel quantitative multi-site ultrasound device Osteoporos Int 11 8 688 696 11095172 1:STN:280:DC%2BD3M%2FlsFartg%3D%3D
    • (2000) Osteoporos Int , vol.11 , Issue.8 , pp. 688-696
    • Weiss, M.1    Ben-Shlomo, A.B.2    Hagag, P.3    Rapoport, M.4
  • 46
    • 70349913587 scopus 로고    scopus 로고
    • Bone and muscle development during puberty in girls: A seven-year longitudinal study
    • 19419294
    • L Xu PHF Nicholson Q Wang M Alen S Cheng 2009 Bone and muscle development during puberty in girls: a seven-year longitudinal study J Bone Miner Res 24 10 1693 1698 19419294
    • (2009) J Bone Miner Res , vol.24 , Issue.10 , pp. 1693-1698
    • Xu, L.1    Nicholson, P.H.F.2    Wang, Q.3    Alen, M.4    Cheng, S.5
  • 47
    • 0031973823 scopus 로고    scopus 로고
    • Changes in the stiffness, strength, and toughness of human cortical bone with age
    • 9437514 1:STN:280:DyaK1c7gtVWlug%3D%3D
    • P Zioupos JD Currey 1998 Changes in the stiffness, strength, and toughness of human cortical bone with age Bone 22 1 57 56 9437514 1:STN:280:DyaK1c7gtVWlug%3D%3D
    • (1998) Bone , vol.22 , Issue.1 , pp. 57-56
    • Zioupos, P.1    Currey, J.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.