메뉴 건너뛰기




Volumn 30, Issue 6, 2008, Pages 761-767

Prediction of bone mechanical properties using QUS and pQCT: Study of the human distal radius

Author keywords

Axial transmission; Bone mechanical properties; Failure load; Fracture risk assessment; pQCT; QUS; Radius; Young's modulus

Indexed keywords

ACOUSTIC WAVES; BISMUTH PLATING; BONE; COBALT; COBALT COMPOUNDS; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC RADIOGRAPHY; ELASTIC MODULI; ELASTICITY; FINITE ELEMENT METHOD; FORECASTING; FRACTURE FIXATION; GARNETS; IMAGING TECHNIQUES; LOAD TESTING; MECHANICAL PROPERTIES; MECHANICAL TESTING; MEDICAL IMAGING; PARAMETER ESTIMATION; PETROLEUM DEPOSITS; PETROLEUM RESERVOIRS; RISK ASSESSMENT; SILICA; SILICATE MINERALS; TOMOGRAPHY; TRANSMISSIONS; ULTRASONICS; WAVE ENERGY CONVERSION;

EID: 47749144295     PISSN: 13504533     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.medengphy.2007.08.006     Document Type: Article
Times cited : (41)

References (36)
  • 1
    • 0036728261 scopus 로고    scopus 로고
    • A comparison of fracture discrimination using calcaneal quantitative ultrasound and dual X-ray absorptiometry in women with a history of fracture at sites other than the spine and hip
    • Frost M.L., Blake G.M., and Fogelman I. A comparison of fracture discrimination using calcaneal quantitative ultrasound and dual X-ray absorptiometry in women with a history of fracture at sites other than the spine and hip. Calcif Tissue Int 71 3 (2002) 207-211
    • (2002) Calcif Tissue Int , vol.71 , Issue.3 , pp. 207-211
    • Frost, M.L.1    Blake, G.M.2    Fogelman, I.3
  • 2
    • 0038280002 scopus 로고    scopus 로고
    • Hip fracture discrimination study: QUS of the radius and the calcaneum
    • Hans D., Genton L., Allaoua S., Pichard C., and Slosman D.O. Hip fracture discrimination study: QUS of the radius and the calcaneum. J Clin Densitom 6 2 (2003) 163-172
    • (2003) J Clin Densitom , vol.6 , Issue.2 , pp. 163-172
    • Hans, D.1    Genton, L.2    Allaoua, S.3    Pichard, C.4    Slosman, D.O.5
  • 3
    • 0031040692 scopus 로고    scopus 로고
    • The role of ultrasound in the assessment of osteoporosis: a review
    • Njeh C.F., Boivin C.M., and Langton C. The role of ultrasound in the assessment of osteoporosis: a review. Osteoporos Int 7 1 (1997) 7-22
    • (1997) Osteoporos Int , vol.7 , Issue.1 , pp. 7-22
    • Njeh, C.F.1    Boivin, C.M.2    Langton, C.3
  • 4
    • 16644388626 scopus 로고    scopus 로고
    • An in vitro study of the ultrasonic axial transmission technique at the radius: 1-MHz velocity measurements are sensitive to both mineralization and intracortical porosity
    • Bossy E., Talmant M., Peyrin F., Akrout L., Cloetens P., and Laugier P. An in vitro study of the ultrasonic axial transmission technique at the radius: 1-MHz velocity measurements are sensitive to both mineralization and intracortical porosity. J Bone Miner Res 19 9 (2004) 1548-1556
    • (2004) J Bone Miner Res , vol.19 , Issue.9 , pp. 1548-1556
    • Bossy, E.1    Talmant, M.2    Peyrin, F.3    Akrout, L.4    Cloetens, P.5    Laugier, P.6
  • 6
    • 0034511755 scopus 로고    scopus 로고
    • Estimation of wrist fracture load using phalangeal speed of sound: an in vitro study
    • Njeh C.F., Wu C., Fan B., Hans D., Fuerst T., He Y., and Genant H.K. Estimation of wrist fracture load using phalangeal speed of sound: an in vitro study. Ultrasound Med Biol 26 9 (2000) 1517-1523
    • (2000) Ultrasound Med Biol , vol.26 , Issue.9 , pp. 1517-1523
    • Njeh, C.F.1    Wu, C.2    Fan, B.3    Hans, D.4    Fuerst, T.5    He, Y.6    Genant, H.K.7
  • 7
    • 1842858991 scopus 로고    scopus 로고
    • Guided ultrasonic waves in long bones: modelling, experiment and in vivo application
    • Nicholson P.H., Moilanen P., Karkkainen T., Timonen J., and Cheng S. Guided ultrasonic waves in long bones: modelling, experiment and in vivo application. Physiol Meas 23 4 (2002) 755-768
    • (2002) Physiol Meas , vol.23 , Issue.4 , pp. 755-768
    • Nicholson, P.H.1    Moilanen, P.2    Karkkainen, T.3    Timonen, J.4    Cheng, S.5
  • 8
    • 0028886520 scopus 로고
    • Quantitative ultrasound of the tibia: a novel approach for assessment of bone status
    • Foldes A.J., Rimon A., Keinan D., and Popovtzer M. Quantitative ultrasound of the tibia: a novel approach for assessment of bone status. Bone 17 4 (1995) 363-367
    • (1995) Bone , vol.17 , Issue.4 , pp. 363-367
    • Foldes, A.J.1    Rimon, A.2    Keinan, D.3    Popovtzer, M.4
  • 9
    • 0007980412 scopus 로고    scopus 로고
    • A new method for quantitative ultrasound measurements at multiple skeletal sites: first results of precision and fracture discrimination
    • Barkmann R., Kantorovich E., Singal C., Hans D., Genant H., Heller M., et al. A new method for quantitative ultrasound measurements at multiple skeletal sites: first results of precision and fracture discrimination. J Clin Densitom 3 1 (2000) 1-7
    • (2000) J Clin Densitom , vol.3 , Issue.1 , pp. 1-7
    • Barkmann, R.1    Kantorovich, E.2    Singal, C.3    Hans, D.4    Genant, H.5    Heller, M.6
  • 10
    • 0033002460 scopus 로고    scopus 로고
    • Does combining the results from multiple bone sites measured by a new quantitative ultrasound device improve discrimination of hip fracture?
    • Hans D., Srivastav S., Singal C., Barkmann R., Njeh C., Kantorovich E., et al. Does combining the results from multiple bone sites measured by a new quantitative ultrasound device improve discrimination of hip fracture?. J Bone Miner Res 14 4 (1999) 644-651
    • (1999) J Bone Miner Res , vol.14 , Issue.4 , pp. 644-651
    • Hans, D.1    Srivastav, S.2    Singal, C.3    Barkmann, R.4    Njeh, C.5    Kantorovich, E.6
  • 11
    • 1342324684 scopus 로고    scopus 로고
    • Bidirectional axial transmission can improve accuracy and precision of ultrasonic velocity measurement in cortical bone: a validation on test materials
    • Bossy E., Talmant M., Defontaine M., Patat F., and Laugier P. Bidirectional axial transmission can improve accuracy and precision of ultrasonic velocity measurement in cortical bone: a validation on test materials. IEEE Trans Ultrason Ferroelectr Freq Control 51 1 (2004) 71-79
    • (2004) IEEE Trans Ultrason Ferroelectr Freq Control , vol.51 , Issue.1 , pp. 71-79
    • Bossy, E.1    Talmant, M.2    Defontaine, M.3    Patat, F.4    Laugier, P.5
  • 12
    • 24944552841 scopus 로고    scopus 로고
    • Bone microstructure and elastic tissue properties are reflected in QUS axial transmission measurements
    • Raum P., Leguerney I., Chandelier F., Bossy E., Talmant M., Saied A., et al. Bone microstructure and elastic tissue properties are reflected in QUS axial transmission measurements. Ultrasound Med Biol 31 9 (2005) 1225-1235
    • (2005) Ultrasound Med Biol , vol.31 , Issue.9 , pp. 1225-1235
    • Raum, P.1    Leguerney, I.2    Chandelier, F.3    Bossy, E.4    Talmant, M.5    Saied, A.6
  • 14
    • 0036074009 scopus 로고    scopus 로고
    • Development of a new ultrasonic technique for bone and biomaterials in vitro characterization
    • Lefebvre, Deblock, Campistron, and Fabre. Development of a new ultrasonic technique for bone and biomaterials in vitro characterization. J Biomed Mater Res 63 4 (2002) 441-446
    • (2002) J Biomed Mater Res , vol.63 , Issue.4 , pp. 441-446
    • Lefebvre1    Deblock2    Campistron3    Fabre4
  • 15
    • 10044240615 scopus 로고    scopus 로고
    • Thickness sensitivity of ultrasound velocity in long bone phantoms
    • Moilanen, Kilappa, Nicholson, Timonen, and Cheng. Thickness sensitivity of ultrasound velocity in long bone phantoms. Ultrasound Med Biol 30 11 (2004) 1517-1521
    • (2004) Ultrasound Med Biol , vol.30 , Issue.11 , pp. 1517-1521
    • Moilanen1    Kilappa2    Nicholson3    Timonen4    Cheng5
  • 16
    • 34249746868 scopus 로고    scopus 로고
    • Apparent Young's modulus of human radius using inverse finite element method
    • Bosisio, Talmant, Skalli, Laugier, and Mitton. Apparent Young's modulus of human radius using inverse finite element method. J Biomech 40 9 (2006) 2022-2028
    • (2006) J Biomech , vol.40 , Issue.9 , pp. 2022-2028
    • Bosisio1    Talmant2    Skalli3    Laugier4    Mitton5
  • 17
    • 2142716028 scopus 로고    scopus 로고
    • Three-dimensional simulations of ultrasonic axial transmission velocity measurement on cortical bone models
    • Bossy E., Talmant M., and Laugier P. Three-dimensional simulations of ultrasonic axial transmission velocity measurement on cortical bone models. J Acoust Soc Am 115 5 (2004) 2314-2324
    • (2004) J Acoust Soc Am , vol.115 , Issue.5 , pp. 2314-2324
    • Bossy, E.1    Talmant, M.2    Laugier, P.3
  • 18
    • 0033664619 scopus 로고    scopus 로고
    • Analysis of the axial transmission technique for the assessment of skeletal status
    • Camus E., Talmant M., Berger G., and Laugier P. Analysis of the axial transmission technique for the assessment of skeletal status. J Acoust Soc Am 108 6 (2000) 3058-3065
    • (2000) J Acoust Soc Am , vol.108 , Issue.6 , pp. 3058-3065
    • Camus, E.1    Talmant, M.2    Berger, G.3    Laugier, P.4
  • 19
    • 0036301829 scopus 로고    scopus 로고
    • Effect of bone cortical thickness on velocity measurements using ultrasonic axial transmission: a 2D simulation study
    • Bossy E., Talmant M., and Laugier P. Effect of bone cortical thickness on velocity measurements using ultrasonic axial transmission: a 2D simulation study. J Acoust Soc Am 112 1 (2002) 297-307
    • (2002) J Acoust Soc Am , vol.112 , Issue.1 , pp. 297-307
    • Bossy, E.1    Talmant, M.2    Laugier, P.3
  • 20
    • 33646149742 scopus 로고    scopus 로고
    • Measuring guided waves in long bones: modeling and experiments in free and immersed plates
    • Moilanen P., Nicholson P., Kilappa T., Cheng S., and Timonen J. Measuring guided waves in long bones: modeling and experiments in free and immersed plates. Ultrasound Med Biol 32 5 (2006) 709-719
    • (2006) Ultrasound Med Biol , vol.32 , Issue.5 , pp. 709-719
    • Moilanen, P.1    Nicholson, P.2    Kilappa, T.3    Cheng, S.4    Timonen, J.5
  • 21
    • 0027175806 scopus 로고
    • Basic biomechanical measurements of bone: a tutorial
    • Turner C.H., and Burr D.B. Basic biomechanical measurements of bone: a tutorial. Bone 14 4 (1993) 595-608
    • (1993) Bone , vol.14 , Issue.4 , pp. 595-608
    • Turner, C.H.1    Burr, D.B.2
  • 22
    • 0347627538 scopus 로고    scopus 로고
    • Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue
    • Bayraktar H.H., Morgan E.F., Niebur G.L., Morris G.E., Wong E.K., and Keaveny T.M. Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue. J Biomech 37 1 (2004) 27-35
    • (2004) J Biomech , vol.37 , Issue.1 , pp. 27-35
    • Bayraktar, H.H.1    Morgan, E.F.2    Niebur, G.L.3    Morris, G.E.4    Wong, E.K.5    Keaveny, T.M.6
  • 23
    • 0037716746 scopus 로고    scopus 로고
    • Relationships between material properties and CT scan data of cortical bone with and without metastatic lesions
    • Kaneko T.S., Pejcic M.R., Tehranzadeh J., and Keyak J.H. Relationships between material properties and CT scan data of cortical bone with and without metastatic lesions. Med Eng Phys 25 6 (2003) 445-454
    • (2003) Med Eng Phys , vol.25 , Issue.6 , pp. 445-454
    • Kaneko, T.S.1    Pejcic, M.R.2    Tehranzadeh, J.3    Keyak, J.H.4
  • 24
    • 1542405780 scopus 로고    scopus 로고
    • The longitudinal Young's modulus of cortical bone in the midshaft of human femur and its correlation with CT scanning data
    • Cuppone, Seedhom, Berry, and Ostell. The longitudinal Young's modulus of cortical bone in the midshaft of human femur and its correlation with CT scanning data. Calcif Tissue Int 74 (2004) 302-309
    • (2004) Calcif Tissue Int , vol.74 , pp. 302-309
    • Cuppone1    Seedhom2    Berry3    Ostell4
  • 25
    • 0029329134 scopus 로고
    • Relations of mechanical properties to density and CT numbers in human bone
    • Rho, Hobatho, and Ashman. Relations of mechanical properties to density and CT numbers in human bone. Med Eng Phys 17 (1995) 347-355
    • (1995) Med Eng Phys , vol.17 , pp. 347-355
    • Rho1    Hobatho2    Ashman3
  • 26
    • 0026154992 scopus 로고
    • Estimation of mechanical properties of cortical bone by computed tomography
    • Snyder S.M., and Schneider E. Estimation of mechanical properties of cortical bone by computed tomography. J Orthop Res 9 3 (1991) 422-431
    • (1991) J Orthop Res , vol.9 , Issue.3 , pp. 422-431
    • Snyder, S.M.1    Schneider, E.2
  • 27
    • 43249111620 scopus 로고    scopus 로고
    • Prediction of mechanical properties of cortical bone by quantitative computed tomography
    • Duchemin, Bousson, Raossanaly, Bergot, Laredo, Skalli, et al. Prediction of mechanical properties of cortical bone by quantitative computed tomography. Medical Engineering and Physics (2007) 25
    • (2007) Medical Engineering and Physics , pp. 25
    • Duchemin1    Bousson2    Raossanaly3    Bergot4    Laredo5    Skalli6
  • 28
    • 2442455520 scopus 로고    scopus 로고
    • Can geometry-based parameters from pQCT and material parameters from quantitative ultrasound (QUS) improve the prediction of radial bone strength over that by bone mass (DXA)?
    • Hudelmaier M., Kuhn V., Lochmuller E.M., Well H., Priernel M., Link T.M., et al. Can geometry-based parameters from pQCT and material parameters from quantitative ultrasound (QUS) improve the prediction of radial bone strength over that by bone mass (DXA)?. Osteoporos Int 15 5 (2004) 375-381
    • (2004) Osteoporos Int , vol.15 , Issue.5 , pp. 375-381
    • Hudelmaier, M.1    Kuhn, V.2    Lochmuller, E.M.3    Well, H.4    Priernel, M.5    Link, T.M.6
  • 29
    • 2442564886 scopus 로고    scopus 로고
    • Predicting the failure load of the distal radius
    • Muller M.E., Webber C.E., and Bouxsein M.L. Predicting the failure load of the distal radius. Osteoporos Int 14 4 (2003) 345-352
    • (2003) Osteoporos Int , vol.14 , Issue.4 , pp. 345-352
    • Muller, M.E.1    Webber, C.E.2    Bouxsein, M.L.3
  • 30
    • 0034115087 scopus 로고    scopus 로고
    • Prediction of bone strength of distal forearm using radius bone mineral density and phalangeal speed of sound
    • Wu, Hans, He, Fan, Njeh, Augat, et al. Prediction of bone strength of distal forearm using radius bone mineral density and phalangeal speed of sound. Bone 26 5 (2000) 529-533
    • (2000) Bone , vol.26 , Issue.5 , pp. 529-533
    • Wu1    Hans2    He3    Fan4    Njeh5    Augat6
  • 31
    • 34848898398 scopus 로고    scopus 로고
    • Ultrasonically determined thickness of long cortical bones: three-dimensional simulations of in vitro experiments
    • Moilanen P., Talmant M., Nicholson P., Cheng S., Timonen J., and Laugier P. Ultrasonically determined thickness of long cortical bones: three-dimensional simulations of in vitro experiments. J Acoust Soc Am 122 3 (2007) 1818
    • (2007) J Acoust Soc Am , vol.122 , Issue.3 , pp. 1818
    • Moilanen, P.1    Talmant, M.2    Nicholson, P.3    Cheng, S.4    Timonen, J.5    Laugier, P.6
  • 32
    • 29244441162 scopus 로고    scopus 로고
    • Nonlinear resonant ultrasound spectroscopy (NRUS) applied to damage assessment in bone
    • Muller M., Sutin A., Guyer R., Talmant M., Laugier P., and Johnson P. Nonlinear resonant ultrasound spectroscopy (NRUS) applied to damage assessment in bone. J Acoust Soc Am 118 6 (2005) 3946
    • (2005) J Acoust Soc Am , vol.118 , Issue.6 , pp. 3946
    • Muller, M.1    Sutin, A.2    Guyer, R.3    Talmant, M.4    Laugier, P.5    Johnson, P.6
  • 33
    • 0028364291 scopus 로고
    • Velocity of ultrasound and its association with fracture history in a rural population
    • Stegman M.R., Heaney R.P., Recker R.R., Travers-Gustafson D., and Leist J. Velocity of ultrasound and its association with fracture history in a rural population. Am J Epidemiol 139 10 (1994) 1027-1034
    • (1994) Am J Epidemiol , vol.139 , Issue.10 , pp. 1027-1034
    • Stegman, M.R.1    Heaney, R.P.2    Recker, R.R.3    Travers-Gustafson, D.4    Leist, J.5
  • 34
    • 0024602773 scopus 로고
    • Osteoporotic bone fragility. Detection by ultrasound transmission velocity
    • Heaney R.P., Avioli L.V., Chesnut C.H., Lappe J., Recker R.R., and Brandeburger G.H. Osteoporotic bone fragility. Detection by ultrasound transmission velocity. JAMA 261 20 (1989) 2986-2990
    • (1989) JAMA , vol.261 , Issue.20 , pp. 2986-2990
    • Heaney, R.P.1    Avioli, L.V.2    Chesnut, C.H.3    Lappe, J.4    Recker, R.R.5    Brandeburger, G.H.6
  • 35
    • 0028931929 scopus 로고
    • Comparison of speed of sound ultrasound with single photon absorptiometry for determining fracture odds ratios
    • Stegman M.R., Heaney R.P., and Recker R.R. Comparison of speed of sound ultrasound with single photon absorptiometry for determining fracture odds ratios. J Bone Miner Res 10 3 (1995) 346-352
    • (1995) J Bone Miner Res , vol.10 , Issue.3 , pp. 346-352
    • Stegman, M.R.1    Heaney, R.P.2    Recker, R.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.