메뉴 건너뛰기




Volumn 14, Issue 12, 2003, Pages 1020-1027

Assessment of the tibia using ultrasonic guided waves in pubertal girls

Author keywords

Bone mineral density and cortical thickness; Tibia; Ultrasonic guided waves; Ultrasound velocities

Indexed keywords

CALCIUM; VITAMIN D;

EID: 2642530630     PISSN: 0937941X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00198-003-1528-7     Document Type: Article
Times cited : (67)

References (33)
  • 1
    • 0035857351 scopus 로고    scopus 로고
    • Osteoporosis prevention, diagnosis, and therapy
    • National Consensus Development Panel (2002) Osteoporosis prevention, diagnosis, and therapy. JAMA 285:785-795
    • (2002) JAMA , vol.285 , pp. 785-795
  • 3
    • 0343570527 scopus 로고    scopus 로고
    • An update on the diagnosis and assessment of osteoporosis with densitometry
    • Kanis JA, Gluer CC (2001) An update on the diagnosis and assessment of osteoporosis with densitometry. Osteoporos Int 11:192-202
    • (2001) Osteoporos Int , vol.11 , pp. 192-202
    • Kanis, J.A.1    Gluer, C.C.2
  • 4
    • 0033040415 scopus 로고    scopus 로고
    • Prediction of the strength of the elderly proximal femur by bone mineral density and quantitative ultrasound measurements of the heel and tibia
    • Bouxsein ML, Coan BS, Lee SC (1999) Prediction of the strength of the elderly proximal femur by bone mineral density and quantitative ultrasound measurements of the heel and tibia. Bone 25:49-54
    • (1999) Bone , vol.25 , pp. 49-54
    • Bouxsein, M.L.1    Coan, B.S.2    Lee, S.C.3
  • 5
    • 0035142186 scopus 로고    scopus 로고
    • Quantitative ultrasound and bone mineral density are equally strongly associated with risk factors for osteoporosis
    • Frost ML, Blake GM, Fogelman I (2001) Quantitative ultrasound and bone mineral density are equally strongly associated with risk factors for osteoporosis. J Bone Miner Res 16:406-416
    • (2001) J Bone Miner Res , vol.16 , pp. 406-416
    • Frost, M.L.1    Blake, G.M.2    Fogelman, I.3
  • 7
    • 0031717927 scopus 로고    scopus 로고
    • Prediction of fracture risk by radiographic absorptiometry and quantitative ultrasound: A prospective study
    • Huang C, Ross PD, Yates AJ, Walker RE, Imose K, Emi K, Wasnich RD (1998) Prediction of fracture risk by radiographic absorptiometry and quantitative ultrasound: a prospective study. Calcif Tissue Int 63:380-384
    • (1998) Calcif Tissue Int , vol.63 , pp. 380-384
    • Huang, C.1    Ross, P.D.2    Yates, A.J.3    Walker, R.E.4    Imose, K.5    Emi, K.6    Wasnich, R.D.7
  • 8
    • 0029123721 scopus 로고
    • Predicting vertebral deformity using bone densitometry at various skeletal sites and calcaneus ultrasound
    • Ross P, Huang C, Davis J, Imose K, Yates J, Vogel J, Wasnich R (1995) Predicting vertebral deformity using bone densitometry at various skeletal sites and calcaneus ultrasound. Bone 16:325-332
    • (1995) Bone , vol.16 , pp. 325-332
    • Ross, P.1    Huang, C.2    Davis, J.3    Imose, K.4    Yates, J.5    Vogel, J.6    Wasnich, R.7
  • 9
    • 0033664619 scopus 로고    scopus 로고
    • Analysis of the axial transmission technique for the assessment of skeletal status
    • Camus E, Talmant M, Berger G, Laugier P (2000) Analysis of the axial transmission technique for the assessment of skeletal status. J Acoust Soc Am 108:3058-3065
    • (2000) J Acoust Soc Am , vol.108 , pp. 3058-3065
    • Camus, E.1    Talmant, M.2    Berger, G.3    Laugier, P.4
  • 11
    • 0001404956 scopus 로고
    • The determination of fracture healing by measurement of sound velocity across the fracture site
    • Siegel IM, Anast GT, Fields T (1958) The determination of fracture healing by measurement of sound velocity across the fracture site. Surg Gynecol Obstet 107:327-332
    • (1958) Surg Gynecol Obstet , vol.107 , pp. 327-332
    • Siegel, I.M.1    Anast, G.T.2    Fields, T.3
  • 12
    • 0030068851 scopus 로고    scopus 로고
    • In vivo assessment of bone mechanical properties by vibration and ultrasonic wave propagation analysis
    • Van der Perre G, Lowet G (1996) In vivo assessment of bone mechanical properties by vibration and ultrasonic wave propagation analysis. Bone 18 [Suppl 1]:29S-35S
    • (1996) Bone , vol.18 , Issue.1 SUPPL.
    • Van Der Perre, G.1    Lowet, G.2
  • 13
    • 0000172550 scopus 로고    scopus 로고
    • Non-heel quantitative ultrasound devices
    • Njeh CF, Hans D, Fuerst T, Gluer CC, Genant HK (eds) Martin Dunitz, London
    • Hans D, Fan B, Fuerst T (1999). Non-heel quantitative ultrasound devices. In: Njeh CF, Hans D, Fuerst T, Gluer CC, Genant HK (eds) Quantitative ultrasound: assessment of osteoporosis and bone status. Martin Dunitz, London, pp 145-162
    • (1999) Quantitative Ultrasound: Assessment of Osteoporosis and Bone Status , pp. 145-162
    • Hans, D.1    Fan, B.2    Fuerst, T.3
  • 14
    • 0028886520 scopus 로고
    • Quantitative ultrasound of the tibia: A novel approach for assessment of bone status
    • Foldes AJ, Rimon A, Keinan DD, Popovtzer MM (1995) Quantitative ultrasound of the tibia: a novel approach for assessment of bone status. Bone 17:363-367
    • (1995) Bone , vol.17 , pp. 363-367
    • Foldes, A.J.1    Rimon, A.2    Keinan, D.D.3    Popovtzer, M.M.4
  • 15
    • 0030804819 scopus 로고    scopus 로고
    • Tibial ultrasound velocity measured in situ predicts the material properties of tibial cortical bone
    • Lee SC, Coan BS, Bouxsein ML (1997) Tibial ultrasound velocity measured in situ predicts the material properties of tibial cortical bone. Bone 21:119-125
    • (1997) Bone , vol.21 , pp. 119-125
    • Lee, S.C.1    Coan, B.S.2    Bouxsein, M.L.3
  • 17
  • 18
    • 0031243710 scopus 로고    scopus 로고
    • Measuring tibial cortical bone status by ultrasonic velocity
    • Taipei
    • Wang SF, Chang CY, Shih C, Teng MM (1997) Measuring tibial cortical bone status by ultrasonic velocity. Zhonghua Yi Xue Za Zhi (Taipei) 60:199-204
    • (1997) Zhonghua Yi Xue Za Zhi , vol.60 , pp. 199-204
    • Wang, S.F.1    Chang, C.Y.2    Shih, C.3    Teng, M.M.4
  • 19
    • 0028931929 scopus 로고
    • Comparison of speed of sound ultrasound with single photon absorptiometry for determining fracture odds ratios
    • Stegman MR, Heaney RP, Recker RR (1995) Comparison of speed of sound ultrasound with single photon absorptiometry for determining fracture odds ratios. J Bone Miner Res 10:346-352
    • (1995) J Bone Miner Res , vol.10 , pp. 346-352
    • Stegman, M.R.1    Heaney, R.P.2    Recker, R.R.3
  • 20
    • 0036301829 scopus 로고    scopus 로고
    • Effect of bone cortical thickness on velocity measurements using ultrasonic axial transmission: A 2D simulation study
    • Bossy E, Talmant M, Laugier P (2002) Effect of bone cortical thickness on velocity measurements using ultrasonic axial transmission: a 2D simulation study. J Acoust Soc Am 112:297-307
    • (2002) J Acoust Soc Am , vol.112 , pp. 297-307
    • Bossy, E.1    Talmant, M.2    Laugier, P.3
  • 21
    • 0033382521 scopus 로고    scopus 로고
    • An in vitro investigation of the dependence on sample thickness of the speed of sound along the specimen
    • Njeh CF, Hans D, Wu C, Kantorovich E, Sister M, Fuerst T, Genant HK (1999) An in vitro investigation of the dependence on sample thickness of the speed of sound along the specimen. Med Eng Phys 21:651-659
    • (1999) Med Eng Phys , vol.21 , pp. 651-659
    • Njeh, C.F.1    Hans, D.2    Wu, C.3    Kantorovich, E.4    Sister, M.5    Fuerst, T.6    Genant, H.K.7
  • 24
    • 0032413597 scopus 로고    scopus 로고
    • Observation of flexural Lamb waves (A0 mode) on water-filled cylindrical shells
    • Cheeke JDN, Li X, Wang Z (1998) Observation of flexural Lamb waves (A0 mode) on water-filled cylindrical shells. J Acoust Soc Am 104:3678-3680
    • (1998) J Acoust Soc Am , vol.104 , pp. 3678-3680
    • Cheeke, J.D.N.1    Li, X.2    Wang, Z.3
  • 25
    • 0031145111 scopus 로고    scopus 로고
    • Guided waves in plates and their use in materials characterization
    • Chimenti DE (1997) Guided waves in plates and their use in materials characterization. Appl Mech Rev 50:247-284
    • (1997) Appl Mech Rev , vol.50 , pp. 247-284
    • Chimenti, D.E.1
  • 26
    • 0026027321 scopus 로고
    • Nondestructive evaluation of composite laminates by leaky Lamb waves
    • Chimenti DE, Martin RW (1991) Nondestructive evaluation of composite laminates by leaky Lamb waves. Ultrasonics 29:13
    • (1991) Ultrasonics , vol.29 , pp. 13
    • Chimenti, D.E.1    Martin, R.W.2
  • 27
    • 0025299043 scopus 로고
    • Inversion of leaky Lamb wave data by simplex algorithm
    • Karim MR, Mal AK, Bar-Cohen Y (1990) Inversion of leaky Lamb wave data by simplex algorithm. J Acoust Soc Am 88:482-491
    • (1990) J Acoust Soc Am , vol.88 , pp. 482-491
    • Karim, M.R.1    Mal, A.K.2    Bar-Cohen, Y.3
  • 28
    • 20444477276 scopus 로고    scopus 로고
    • Investigation of guided ultrasonic waves in bone phantoms using an axial transmission method
    • Pierce AD (ed)
    • Moilanen P, Timonen J, Karkkainen T, Nicholson PHF, Cheng S (2001) Investigation of guided ultrasonic waves in bone phantoms using an axial transmission method. In: Pierce AD (ed) Acoust Soc Am 110:2622
    • (2001) Acoust Soc Am , vol.110 , pp. 2622
    • Moilanen, P.1    Timonen, J.2    Karkkainen, T.3    Nicholson, P.H.F.4    Cheng, S.5
  • 30
    • 1842858991 scopus 로고    scopus 로고
    • Guided ultrasonic waves in long bones: Modelling, experiment and in vivo application
    • Nicholson PHF, Moilanen P, Karkkainen T, Timonen J, Cheng S (2002) Guided ultrasonic waves in long bones: modelling, experiment and in vivo application. Physiol Meas 23:755-768
    • (2002) Physiol Meas , vol.23 , pp. 755-768
    • Nicholson, P.H.F.1    Moilanen, P.2    Karkkainen, T.3    Timonen, J.4    Cheng, S.5
  • 32
    • 0030271192 scopus 로고    scopus 로고
    • Ultrasound velocity measurement in long bones: Measurement method and simulation of ultrasound wave propagation
    • Lowet G, Van der Perre G (1996) Ultrasound velocity measurement in long bones: measurement method and simulation of ultrasound wave propagation. J Biomech 29:1255-1262
    • (1996) J Biomech , vol.29 , pp. 1255-1262
    • Lowet, G.1    Van Der Perre, G.2
  • 33
    • 0029112340 scopus 로고
    • Accurate assessment of precision errors: How to measure the reproducibility of bone densitometry techniques
    • Gluer CC, Blake G, Lu Y, Blunt BA, Jergas M, Genant HK (1995) Accurate assessment of precision errors: how to measure the reproducibility of bone densitometry techniques. Osteoporos Int 5:262-270
    • (1995) Osteoporos Int , vol.5 , pp. 262-270
    • Gluer, C.C.1    Blake, G.2    Lu, Y.3    Blunt, B.A.4    Jergas, M.5    Genant, H.K.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.